  1. Table 5.1(a) Fire integrity of bulkheads separating adjacent spaces Fire integrity of bulkheads separating adjacent spaces
  2. Table 5.2(a) Fire integrity of decks separating adjacent spaces Fire integrity of decks separating adjacent spaces

Table 5.1(a) Fire integrity of bulkheads separating adjacent spaces Fire integrity of bulkheads separating adjacent spaces

On page 55, in Table 5.1(a) in paragraph (2), subparagraph (h) of the Annex, concerning the Annex to Directive 2009/45/EC: for: Spaces (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) Control stations (1) A-0e A-0 60 A-0 A-15 A-60 A-15 A-60 A-60 * A-60 Corridors (2) Ce B-0e A-0e B-0e B-0e A-60 A-15 A-60 A-15 A-0d * A-30 Accommodation spaces (3) Ce A-0e B-0e B-0e A-60 A-0 A-0 A-15 A-0d * A-30 A-0d Stairways (4) A-0e B-0e A-0e B-0e A-60 A-0 A-0 A-15 A-0d * A-30 Service spaces (low risk) (5) Ce A-60 A-0 A-0 A-0 * A-0 Machinery spaces of category A (6) * A-0 A-0 A-60 * A-60 Other machinery spaces (7) A-0b A-0 A-0 * A-0 Cargo spaces (8) * A-0 * A-0 Service spaces (high risk) (9) A-0b * A-30 Open decks (10) A-0 Special category and Ro-Ro spaces (11) A-30 read: Spaces (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) Control stations (1) A-0c A-0 A-60 A-0 A-15 A-60 A-15 A-60 A-60 * A-60 Corridors (2) Ce B-0e A-0a B-0e B-0e A-60 A-0 A-0 A-15 A-0d * A-30 Accommodation spaces (3) Ce A-0a B-0e B-0e A-60 A-0 A-0 A-15 A-0d * A-30 A-0d Stairways (4) A-0a B-0e A-0a B-0e A-60 A-0 A-0 A-15 A-0d * A-30 Service spaces (low risk) (5) Ce A-60 A-0 A-0 A-0 * A-0 Machinery spaces of category A (6) * A-0 A-0 A-60 * A-60 Other machinery spaces (7) A-0b A-0 A-0 * A-0 Cargo spaces (8) * A-0 * A-0 Service spaces (high risk) (9) A-0b * A-30 Open decks (10) A-0 Special category spaces (11) A-30

Table 5.2(a) Fire integrity of decks separating adjacent spaces Fire integrity of decks separating adjacent spaces

on page 56, in Table 5.2(a) in paragraph (2), subparagraph (i) of the Annex, concerning the Annex to Directive 2009/45/EC: for: Spaces Below↓ Spaces → Above (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) Control stations (1) A-0 A-0 A-0 A-0 A-0 A-60 A-0 A-0 A-0 * A-60 Corridors (2) A-0 * * A-0 * A-60 A-0 A-0 A-0 * A-30 Accommodation spaces (3) A-60 A-0 * A-0 * A-60 A-0 A-0 A-0 * A-30 A-0d Stairways (4) A-0 A-0 A-0 * A-0 A-60 A-0 A-0 A-0 * A-30 Service spaces (low risk) (5) A-15 A-0 A-0 A-0 * A-60 A-0 A-0 A-0 * A-0 Machinery spaces of category A (6) A-60 A-60 A-60 A-60 A-60 * A-60f A-30 A-60 * A-60 Other machinery spaces (7) A-15 A-0 A-0 A-0 A-0 A-0 * A-0 A-0 * A-0 Cargo spaces (8) A-60 A-0 A-0 A-0 A-0 A-0 A-0 * A-0 * A-0 Service spaces (high risk) (9) A-60 A-30 A-0d A-30 A-0d A-30 A-0d A-0 A-60 A-0 A-0 A-0 * A-30 Open decks (10) * * * * * * * * * — A-0 Special category and Ro-Ro spaces (11) A-60 A-30 A-30 A-0d A-30 A-0 A-60 A-0 A-0 A-30 A-0 A-30 read: Space Below↓ Space Above → (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) Control stations (1) A-0 A-0 A-0 A-0 A-0 A-60 A-0 A-0 A-0 * A-60 Corridors (2) A-0 * * A-0 * A-60 A-0 A-0 A-0 * A-30 Accommodation spaces (3) A-60 A-0 * A-0 * A-60 A-0 A-0 A-0 * A-30 A-0d Stairways (4) A-0 A-0 A-0 * A-0 A-60 A-0 A-0 A-0 * A-30 Service spaces (low risk) (5) A-15 A-0 A-0 A-0 * A-60 A-0 A-0 A-0 * A-0 Machinery spaces of category A (6) A-60 A-60 A-60 A-60 A-60 * A-60f A-30 A-60 * A-60 Other machinery spaces (7) A-15 A-0 A-0 A-0 A-0 A-0 * A-0 A-0 * A-0 Cargo spaces (8) A-60 A-0 A-0 A-0 A-0 A-0 A-0 * A-0 * A-0 Service spaces (high risk) (9) A-60 A-30 A-0d A-30 A-0d A-30 A-0d A-0 A-60 A-0 A-0 A-0 * A-30 Open decks (10) * * * * * * * * * — A-0 Special category spaces (11) A-60 A-30 A-30 A-0d A-30 A-0 A-60 A-0 A-0 A-30 A-0 A-30

.7 on page 61, in paragraph (2)(l) of the Annex, concerning point 7 of the rule 9a in Annex I to Directive 2009/45/EC: for: Ventilation systems for laundries in passenger ships carrying more than 36 passengers Exhaust ducts from laundries and drying rooms of category (13) spaces as defined in Regulation II-2/B//.2.2 shall be fitted with:, read: Ventilation systems for laundries in passenger ships carrying more than 36 passengers Exhaust ducts from laundries and drying rooms of category (13) spaces as defined in Regulation II-2/B/4.2.2 shall be fitted with:.