Commission Implementing Decision of 19 December 2011 establishing harmonised efficiency reference values for separate production of electricity and heat in application of Directive 2004/8/EC of the European Parliament and of the Council and repealing Commission Decision 2007/74/EC (notified under document C(2011) 9523) (2011/877/EU)
Grade B
mapped from publisher markup. A grade says how a document's structure was obtained, not how reliable the law is.
Address https://gelex.eu/eli/EU/decision/2011/877@2011-12-19/en
Contents
- Preamble
- Article 1 Establishment of the harmonised efficiency reference values
- Article 2 Application of the harmonised efficiency reference values
- Article 3 Correction factors for the harmonised efficiency reference values for separate production of electricity
- Article 4 Retrofitting of a cogeneration unit
- Article 5 Fuel mix
- Article 6 Repeal
- Article 7
- ANNEX
- ANNEX I Harmonised efficiency reference values for separate production of electricity (referred to in Article 1)
- ANNEX II Harmonised efficiency reference values for separate production of heat (referred to in Article 1)
- ANNEX III Correction factors relating to the average climatic situation and method for establishing climate zones for the application of the harmonised efficiency reference values for separate production of electricity (referred to in Article 3(1))
- (a)
- ANNEX IV Correction factors for avoided grid losses for the application of the harmonised efficiency reference values for separate production of electricity (referred to in Article 3(2))
THE EUROPEAN COMMISSION,
Having regard to the Treaty on the Functioning of the European Union,
Having regard to Directive 2004/8/EC of the European Parliament and of the Council of 11 February 2004 on the promotion of cogeneration based on a useful heat demand in the internal energy market and amending Directive 92/42/EEC, and in particular Article 4(2) thereof,
Whereas:
(1) Pursuant to Directive 2004/8/EC the Commission established in Decision 2007/74/EC harmonised efficiency reference values for separate production of electricity and heat, consisting of a matrix of values differentiated by relevant factors, including year of construction and types of fuel.
(2) The Commission is to review the harmonised efficiency reference values for separate production of electricity and heat for the first time on 21 February 2011 and every four years thereafter, to take account of technological developments and changes in the distribution of energy sources.
(3) The Commission has reviewed the harmonised efficiency reference values for separate production of electricity and heat, taking into account data from operational use under realistic conditions, provided by the Member States. Developments in the best available and economically justifiable technology which took place during the period 2006-2011 which was covered by the review, indicate that for the harmonised efficiency reference values for separate production of electricity, the distinction drawn in Decision 2007/74/EC relating to the year of construction of a cogeneration unit should not be maintained for plants that were constructed from 1 January 2006 onwards. However for cogeneration units built in 2005 or before the reference values should continue to be applied reflecting the year of construction, in order to take into account the observed developments in the best available and economically justifiable technology. Furthermore, on the basis of recent experience and analysis, the review confirmed that correction factors relating to the climatic situation should continue to be applied. In addition, the correction factors for avoided grid losses should also continue to be applied as grid losses have not changed in recent years. Additionally, the correction factors for avoided grid losses should also apply to plants that use wood fuels and biogas.
(4) The review has not produced evidence to indicate that the energy efficiency of boilers has changed in the period considered, and therefore the harmonised efficiency reference values for the separate production of heat should not relate to the year of construction. No correction factors relating to the climatic situation were required because the thermodynamics of generating heat from fuel do not depend significantly on the ambient temperature. In addition correction factors for heat grid losses are not required as heat is always used near the site of production.
(5) Stable conditions for investment in cogeneration and continued investor confidence are needed. From this perspective, it is also appropriate to extend the current harmonised reference values for electricity and heat to the period 2012-2015.
(6) Data from operational use under realistic conditions do not demonstrate a statistically significant improvement of the actual performance of state-of-the-art plants in the period under review. Therefore the reference values established for the period 2006-2011 in Decision 2007/74/EC should be maintained for the period 2012-2015.
(7) The review confirmed the validity of the existing correction factors relating to the climatic situation and to avoided grid losses.
(8) The use of a single set of reference values for the entire period and the waiving of correction factors for climatic differences and grid losses were also confirmed for heat generation.
(9) Taking into consideration that the main aim of Directive 2004/8/EC is to promote cogeneration in order to save energy, an incentive for retrofitting older cogeneration units should be given in order to improve their energy efficiency. For these reasons the efficiency reference values for electricity applicable to a cogeneration unit should become higher from the 11th year after the year of its construction.
(10) This approach is consistent with the requirement for the harmonised efficiency reference values to be based on the principles mentioned in Annex III, point (f) of Directive 2004/8/EC.
(11) Revised harmonised efficiency reference values for separate production of electricity and heat should be established. Decision 2007/74/EC should, therefore, be repealed.
(12) The measures provided for in this Decision are in accordance with the opinion of the Cogeneration Committee,
HAS ADOPTED THIS DECISION:
Article 1 Establishment of the harmonised efficiency reference values
The harmonised efficiency reference values for separate production of electricity and heat shall be as set out in Annex I and Annex II respectively.
Article 2 Application of the harmonised efficiency reference values
1. Member States shall apply the harmonised efficiency reference values set out in Annex I relating to the year of construction of a cogeneration unit. These harmonised efficiency reference values shall apply for 10 years from the year of construction of a cogeneration unit.
2. From the 11th year following the year of construction of a cogeneration unit, Member States shall apply the harmonised efficiency reference values which by virtue of paragraph 1 apply to a cogeneration unit of 10 years of age. These harmonised efficiency reference values shall apply for one year.
3. For the purpose of this Article the year of construction of a cogeneration unit shall mean the calendar year of the first electricity production.
Article 3 Correction factors for the harmonised efficiency reference values for separate production of electricity
1. Member States shall apply the correction factors set out in Annex III, point (a) in order to adapt the harmonised efficiency reference values set out in Annex I to the average climatic situation in each Member State. If on the territory of a Member State official meteorological data show differences in the annual ambient temperature of 5 °C or more, that Member State may, subject to notification to the Commission, use several climate zones for the purpose of the first subparagraph using the method set out in Annex III, point (b).
2. Member States shall apply the correction factors set out in Annex IV in order to adapt the harmonised efficiency reference values set out in Annex I to avoided grid losses.
3. Where Member States apply both the correction factors set out in Annex III, point (a) and those set out in Annex IV, they shall apply Annex III, point (a) before applying Annex IV.
Article 4 Retrofitting of a cogeneration unit
If an existing cogeneration unit is retrofitted and the investment cost for the retrofitting exceeds 50 % of the investment cost for a new comparable cogeneration unit, the calendar year of first electricity production of the retrofitted cogeneration unit shall be considered as its year of construction for the purpose of Article 2.
Article 5 Fuel mix
If the cogeneration unit is operated with more than one fuel the harmonised efficiency reference values for separate production shall be applied proportionally to the weighted mean of the energy input of the various fuels.
Article 6 Repeal
Decision 2007/74/EC shall be repealed.
Article 7
This Decision is addressed to the Member States.
Done at Brussels, 19 December 2011. For the Commission Günther Oettinger Member of the Commission
ANNEX
ANNEX I Harmonised efficiency reference values for separate production of electricity (referred to in Article 1)
In the table below the harmonised efficiency reference values for separate production of electricity are based on net calorific value and standard ISO conditions (15 °C ambient temperature, 1,013 bar, 60 % relative humidity). Year of construction: Type of fuel 2001 and before 2002 2003 2004 2005 2006-2011 2012-2015 Solids Hard coal/coke 42,7 43,1 43,5 43,8 44,0 44,2 44,2 Lignite/lignite briquettes 40,3 40,7 41,1 41,4 41,6 41,8 41,8 Peat/peat briquettes 38,1 38,4 38,6 38,8 38,9 39,0 39,0 Wood fuels 30,4 31,1 31,7 32,2 32,6 33,0 33,0 Agricultural biomass 23,1 23,5 24,0 24,4 24,7 25,0 25,0 Biodegradable (municipal) waste 23,1 23,5 24,0 24,4 24,7 25,0 25,0 Non-renewable (municipal and industrial) waste 23,1 23,5 24,0 24,4 24,7 25,0 25,0 Oil shale 38,9 38,9 38,9 38,9 38,9 39,0 39,0 Liquids Oil (gas oil + residual fuel oil), LPG 42,7 43,1 43,5 43,8 44,0 44,2 44,2 Biofuels 42,7 43,1 43,5 43,8 44,0 44,2 44,2 Biodegradable waste 23,1 23,5 24,0 24,4 24,7 25,0 25,0 Non-renewable waste 23,1 23,5 24,0 24,4 24,7 25,0 25,0 Gaseous Natural gas 51,7 51,9 52,1 52,3 52,4 52,5 52,5 Refinery gas/hydrogen 42,7 43,1 43,5 43,8 44,0 44,2 44,2 Biogas 40,1 40,6 41,0 41,4 41,7 42,0 42,0 Coke oven gas, blast furnace gas, other waste gases, recovered waste heat 35 35 35 35 35 35 35
ANNEX II Harmonised efficiency reference values for separate production of heat (referred to in Article 1)
In the table below the harmonised efficiency reference values for separate production of heat are based on net calorific value and standard ISO conditions (15 °C ambient temperature, 1,013 bar, 60 % relative humidity). Type of fuel Steam/hot water Direct use of exhaust gases Solids Hard coal/coke 88 80 Lignite/lignite briquettes 86 78 Peat/peat briquettes 86 78 Wood fuels 86 78 Agricultural biomass 80 72 Biodegradable (municipal) waste 80 72 Non-renewable (municipal and industrial) waste 80 72 Oil shale 86 78 Liquids Oil (gas oil + residual fuel oil), LPG 89 81 Bio-fuels 89 81 Biodegradable waste 80 72 Non-renewable waste 80 72 Gaseous Natural gas 90 82 Refinery gas/hydrogen 89 81 Biogas 70 62 Coke oven gas, blast furnace gas, other waste gases, recovered waste heat 80 72
ANNEX III Correction factors relating to the average climatic situation and method for establishing climate zones for the application of the harmonised efficiency reference values for separate production of electricity (referred to in Article 3(1))
(a) Correction factors relating to the average climatic situation Ambient temperature correction is based on the difference between the annual average temperature in a Member State and standard ISO conditions (15 °C). The correction will be as follows: Example: When the average annual temperature in a Member State is 10 °C, the reference value of a cogeneration unit in that Member State has to be increased with 0,5 %-points.
(a)
(i) 0,1 %-point efficiency loss for every degree above 15 °C
(ii) 0,1 %-point efficiency gain for every degree under 15 °C
(b) Method for establishing climate zones The borders of each climate zone will be constituted by isotherms (in full degrees Celsius) of the annual average ambient temperature which differ at least 4 °C. The temperature difference between the average annual ambient temperatures applied in adjacent climate zones will be at least 4 °C. Example: In a Member State the average annual ambient temperature in place A is 12 °C and in place B it is 6 °C. The difference is more than 5 °C. The Member State has now the option to introduce two climate zones separated by the isotherm of 9 °C, thus constituting one climate zone between the isotherms of 9 °C and 13 °C with an average annual ambient temperature of 11 °C and another climate zone between the isotherms of 5 °C and 9 °C with an average annual ambient temperature of 7 °C.
ANNEX IV Correction factors for avoided grid losses for the application of the harmonised efficiency reference values for separate production of electricity (referred to in Article 3(2))
Voltage For electricity exported to the grid For electricity consumed on-site > 200 kV 1 0,985 100-200 kV 0,985 0,965 50-100 kV 0,965 0,945 0,4-50 kV 0,945 0,925 < 0,4 kV 0,925 0,860 Example: A 100 kWel cogeneration unit with a reciprocating engine driven with natural gas generates electricity of 380 V. Of this electricity 85 % is used for own consumption and 15 % is fed into the grid. The plant was constructed in 1999. The annual ambient temperature is 15 °C (so no climatic correction is necessary). In accordance with Article 2 of this Decision for cogeneration units older than 10 years of age the reference values of units of 10 years of age should be applied. According to Annex I to this Decision for a natural gas cogeneration unit built in 1999, which has not been retrofitted, the harmonised efficiency reference value applicable in 2011 is the reference value for 2001, 51,7 %. After the grid loss correction the resulting efficiency reference value for the separate production of electricity in this cogeneration unit would be (based on the weighted mean of the factors in this Annex): Ref Εη = 51,7 % * (0,860 * 85 % + 0,925 * 15 %) = 45,0 %
Versions
Cited by
- Commission Decision (EU) 2015/2099 of 18 November 2015 establishing the ecological criteria for the award of the EU Ecolabel for growing media, soil improvers and mulch (notified under document C(2015) 7891) (Text with EEA relevance) Decision · Grade B
Ref Hη and Ref Eη are the reference efficiencies for the separate production of heat and electricity as defined in the Directive 2012/27/EU of the European Parliament and of the Council and calculated according to the Commission Implementing Decision 2011/877/EU
- Commission Delegated Regulation (EU) 2015/2402 of 12 October 2015 reviewing harmonised efficiency reference values for separate production of electricity and heat in application of Directive 2012/27/EU of the European Parliament and of the Council and repealing Commission Implementing Decision 2011/877/EU Regulation · Grade B
Pursuant to Article 4(1) of Directive 2004/8/EC of the European Parliament and of the Council, the Commission set out in its Implementing Decision 2011/877/EU harmonised efficiency reference values for the separate production of electricity and heat, as a matrix of values differentiated by relevant factors, including year of construction and types of fuel. These values are applicable until 31 December 2015.
- Commission Delegated Regulation (EU) 2015/2402 of 12 October 2015 reviewing harmonised efficiency reference values for separate production of electricity and heat in application of Directive 2012/27/EU of the European Parliament and of the Council and repealing Commission Implementing Decision 2011/877/EU Regulation · Grade B
The Commission has reviewed the harmonised efficiency reference values for the separate production of electricity and heat taking into account data from operational use under realistic conditions, provided by Member States and by stakeholders. As a result of developments in the best available and economically justifiable technology, observed during the review period 2011 to 2015 the distinction drawn in Decision 2011/877/EU relating to the year of construction of a cogeneration unit should be maintained in relation to the harmonised efficiency reference values for separate production of electr
- Commission Delegated Regulation (EU) 2015/2402 of 12 October 2015 reviewing harmonised efficiency reference values for separate production of electricity and heat in application of Directive 2012/27/EU of the European Parliament and of the Council and repealing Commission Implementing Decision 2011/877/EU Regulation · Grade B
The review of the harmonised efficiency reference values confirmed that on the basis of recent experience and analysis, correction factors relating to the climatic situation, as set out in Decision 2011/877/EU, should apply only to plants using gaseous fuels.
- Commission Delegated Regulation (EU) 2015/2402 of 12 October 2015 reviewing harmonised efficiency reference values for separate production of electricity and heat in application of Directive 2012/27/EU of the European Parliament and of the Council and repealing Commission Implementing Decision 2011/877/EU Regulation · Grade B
That review confirmed, based on recent experience and analysis, that the application of correction factors for avoided grid losses set out in Decision 2011/877/EU should continue. In order to better reflect the avoided losses the voltage limits used and the value of the correction factors need to be updated.
- Commission Delegated Regulation (EU) 2015/2402 of 12 October 2015 reviewing harmonised efficiency reference values for separate production of electricity and heat in application of Directive 2012/27/EU of the European Parliament and of the Council and repealing Commission Implementing Decision 2011/877/EU Regulation · Grade B
The reference values for the separate production of heat and electricity established in Decision 2011/877/EU are applicable until 31 December 2015, new reference values need to be applied from 1 January 2016. In order to ensure the applicability of the new set of reference values by that date the current Regulation shall enter into force on the first day following its publication.
- Commission Delegated Regulation (EU) 2015/2402 of 12 October 2015 reviewing harmonised efficiency reference values for separate production of electricity and heat in application of Directive 2012/27/EU of the European Parliament and of the Council and repealing Commission Implementing Decision 2011/877/EU Regulation · Grade B
Decision 2011/877/EU is repealed.
- Directive 2012/27/EU of the European Parliament and of the Council of 25 October 2012 on energy efficiency, amending Directives 2009/125/EC and 2010/30/EU and repealing Directives 2004/8/EC and 2006/32/EC (Text with EEA relevance) Act · Grade B
On the basis of the harmonised efficiency reference values referred to in point (f) of Annex II, Member States shall ensure that the origin of electricity produced from high-efficiency cogeneration can be guaranteed according to objective, transparent and non-discriminatory criteria laid down by each Member State. They shall ensure that this guarantee of origin complies with the requirements and contains at least the information specified in Annex X. Member States shall mutually recognise their guarantees of origin, exclusively as proof of the information referred to in this paragraph. Any ref
- Communication from the Commission Guidelines on certain State aid measures in the context of the greenhouse gas emission allowance trading scheme post-2012 (SWD(2012) 130 final) (SWD(2012) 131 final) (Text with EEA relevance) 2012/C 158/04 Notice · Grade B
the new highly efficient power plant exceeds the harmonised efficiency reference value of the power plants set out in Annex I to Commission Implementing Decision 2011/877/EU of 19 December 2011 establishing harmonised efficiency reference values for separate production of electricity and heat in application of Directive 2004/8/EC of the European Parliament and of the Council or the relevant efficiency reference value in force when the aid is granted. New highly efficient power plants which merely comply with those efficiency reference values shall not be eligible for aid; and