Commission Implementing Decision of 9 October 2014 establishing best available techniques (BAT) conclusions, under Directive 2010/75/EU of the European Parliament and of the Council on industrial emissions, for the refining of mineral oil and gas (notified under document C(2014) 7155) (Text with EEA relevance) (2014/738/EU)
Grade B
mapped from publisher markup. A grade says how a document's structure was obtained, not how reliable the law is.
Address https://gelex.eu/eli/EU/decision/2014/738@2014-10-09/en
Contents
- Preamble
- ANNEX
- ANNEX BAT CONCLUSIONS FOR THE REFINING OF MINERAL OIL AND GAS SCOPE
- Averaging periods and reference conditions for emissions to air Table 1 Reference conditions for BAT-AELs concerning emissions to air
- Conversion of emissions concentration to reference oxygen level
- Averaging periods and reference conditions for emissions to water
- 1.1.
- 1.1.1.
- BAT 1.
- 1.1.2.BAT 2.(i)a.b.c.(ii)a.b.c.(iii)a.b.
- 1.1.3.BAT 3.
- 1.1.4.BAT 4.(i)(ii)(iii)(iv)(v)
- BAT 6.
- 1.1.5.BAT 8. Table 2 BAT 9. BAT-associated emission levels for ammonia (NH3) emissions to air for a combustion or process unit where SCR or SNCR techniques are used
- 1.1.5.
- BAT 7. Description
- 1.1.6.BAT 10.
- 1.1.7.BAT 11.(i)(ii)(iii)(iv)BAT 12.(i)(ii)(iii)BAT 13. Table 3 BAT-associated emission levels for direct waste water discharges from the refining of mineral oil and gas and monitoring frequencies associated with BAT
- 1.1.8.BAT 14.BAT 15.(i)(ii)BAT 16.(i)(ii)
- 1.1.9.BAT 17.
- 1.1.10.BAT 18.I.II.III.
- 1.1.10.BAT 18.I.
- 1.1.10.BAT 18.I.II.
- 1.2.
- 1.2.1.BAT 20.(i)(ii)
- 1.2.1.
- BAT 19. Description
- 1.2.2.BAT 21.
- 1.3.BAT 22.(i)(ii)(iii)(iv)
- 1.4.BAT 23.(i)(ii)
- 1.5.
- BAT 24.I.(i)(ii)(iii)II.(i)(ii)(iii) Table 4 BAT-associated emission levels for NOX emissions to air from the regenerator in the catalytic cracking process
- BAT 25.I.(i)(ii)II.(i)(ii)(iii)(iv) Table 5 BAT-associated emission levels for dust emissions to air from the regenerator in the catalytic cracking process
- BAT 26.I.(i)(ii)II.(i)(ii) Table 6 BAT-associated emission levels for SO2 emissions to air from the regenerator in the catalytic cracking process
- BAT 27.(i)(ii)(iii) Table 7 BAT-associated emission levels for carbon monoxide emissions to air from the regenerator in the catalytic cracking process for partial combustion mode
- 1.6.BAT 28.(i)(ii)a.b.c.
- 1.7.BAT 29.(i)(ii)(iii)(iv)BAT 31.(i)(ii)
- 1.7.BAT 29.(i)(ii)(iii)(iv)
- BAT 30. Description
- BAT 32.(i)(ii) Table 8 BAT-associated emission levels for dust emissions to air from a unit for the calcining of green coke
- 1.8.BAT 33.(i)(ii)(iii)
- 1.9.
- BAT 34.I.(i)(a)(b)(ii)(a)(b)(c)(d)(e)II.(i)(ii)(iii)(iv) Table 9 Table 10 Table 11 BAT-associated emission levels for NOX emissions to air from a gas turbine BAT-associated emission levels for NOX emissions to air from a gas-fired combustion unit, with the exception of gas turbines BAT-associated emission levels for NOX emissions to air from a multi-fuel fired combustion unit with the exception of gas turbines
- BAT 35.I.(i)(a)(b)(ii)(a)(b)II.(i)(ii)(iii)(iv) Table 12 BAT-associated emission levels for dust emissions to air from a multi-fuel fired combustion unit with the exception of gas turbines
- BAT 36.I.(i)(ii)(iii)II.(i)(ii)(iii) Table 13 Table 14 BAT-associated emission levels for SO2 emissions to air from a combustion unit firing refinery fuel gas (RFG), with the exception of gas turbines BAT-associated emission levels for SO2 emissions to air from multi-fuel fired combustion units, with the exception of gas turbines and stationary gas engines This BAT-AEL refers to the weighted average emissions from existing multi-fuel fired combustion units within the refinery, with the exception of gas turbines and stationary gas engines.
- BAT 37. Table 15 BAT-associated emission levels for carbon monoxide emissions to air from a combustion unit
- 1.10.BAT 38.BAT 39.
- 1.12.BAT 41.BAT 42.BAT 43.
- 1.13.
- BAT 44. Applicability
- 1.13.BAT 45.
- BAT 46. Applicability
- 1.14.
- BAT 47. Applicability
- 1.15.BAT 50.(i)(ii)BAT 51.(i)(ii)(iii)(iv)
- 1.15.
- BAT 49. Description
- BAT 52. Table 16 BAT-associated emission levels for non-methane VOC and benzene emissions to air from loading and unloading operations of volatile liquid hydrocarbon compounds
- 1.17.
- BAT 54.(i)(ii)(iii) Table 17 BAT-associated environmental performance levels for a waste gas sulphur (H2S) recovery system
- 1.18.BAT 55.BAT 56.(i)(ii)(iii)(iv)
- 1.19.
- BAT 57. Description Notes: 1.2.3.
- Table 18 BAT-associated emission levels for NOx emissions to air when applying BAT 57
- BAT 58. Description Notes: 1.2.3.
- Table 19 BAT-associated emission levels for SO2 emissions to air when applying BAT 58
- 1.20.
- 1.21.
THE EUROPEAN COMMISSION,
Having regard to the Treaty on the Functioning of the European Union,
Having regard to Directive 2010/75/EU of the European Parliament and of the Council of 24 November 2010 on industrial emissions (integrated pollution prevention and control), and in particular Article 13(5) thereof,
Whereas:
(1) Article 13(1) of Directive 2010/75/EU requires the Commission to organise an exchange of information on industrial emissions between it and Member States, the industries concerned and non-governmental organisations promoting environmental protection in order to facilitate the drawing up of best available techniques (BAT) reference documents as defined in Article 3(11) of that Directive.
(2) In accordance with Article 13(2) of Directive 2010/75/EU, the exchange of information is to address the performance of installations and techniques in terms of emissions, expressed as short- and long-term averages, where appropriate, and the associated reference conditions, consumption and nature of raw materials, water consumption, use of energy and generation of waste and the techniques used, associated monitoring, cross-media effects, economic and technical viability and developments therein and best available techniques and emerging techniques identified after considering the issues mentioned in points (a) and (b) of Article 13(2) of that Directive.
(3) BAT conclusions as defined in Article 3(12) of Directive 2010/75/EU are the key element of BAT reference documents and lay down the conclusions on best available techniques, their description, information to assess their applicability, the emission levels associated with the best available techniques, associated monitoring, associated consumption levels and, where appropriate, relevant site remediation measures.
(4) In accordance with Article 14(3) of Directive 2010/75/EU, BAT conclusions are to be the reference for setting permit conditions for installations covered by Chapter II of that Directive.
(5) Article 15(3) of Directive 2010/75/EU requires the competent authority to set emission limit values that ensure that, under normal operating conditions, emissions do not exceed the emission levels associated with the best available techniques as laid down in the decisions on BAT conclusions referred to in Article 13(5) of Directive 2010/75/EU.
(6) Article 15(4) of Directive 2010/75/EU provides for derogations from the requirement laid down in Article 15(3) only where the costs associated with the achievement of the emission levels associated with the BAT disproportionately outweigh the environmental benefits due to the geographical location, the local environmental conditions or the technical characteristics of the installation concerned.
(7) Article 16(1) of Directive 2010/75/EU provides that the monitoring requirements in the permit referred to in point (c) of Article 14(1) of the Directive are to be based on the conclusions on monitoring as described in the BAT conclusions.
(8) In accordance with Article 21(3) of Directive 2010/75/EU, within 4 years of publication of decisions on BAT conclusions, the competent authority is to reconsider and, if necessary, update all the permit conditions and ensure that the installation complies with those permit conditions.
(9) The Commission established a forum composed of representatives of Member States, the industries concerned and non-governmental organisations promoting environmental protection by Decision of 16 May 2011 establishing a forum for the exchange of information pursuant to Article 13 of Directive 2010/75/EU on industrial emissions.
(10) In accordance with Article 13(4) of Directive 2010/75/EU, the Commission obtained the opinion of the forum, established by Decision of 16 May 2011, on the proposed content of the BAT reference document for the refining of mineral oil and gas on 20 September 2013 and made it publicly available.
(11) The measures provided for in this Decision are in accordance with the opinion of the Committee established by Article 75(1) of Directive 2010/75/EU,
HAS ADOPTED THIS DECISION:
Article 1
The BAT conclusions for the refining of mineral oil and gas, as set out in the Annex, are adopted.
Article 2
This Decision is addressed to the Member States.
Done at Brussels, 9 October 2014. For the Commission Janez Potočnik Member of the Commission
ANNEX
ANNEX BAT CONCLUSIONS FOR THE REFINING OF MINERAL OIL AND GAS SCOPE
These BAT conclusions cover certain industrial activities specified in Section 1.2 of Annex I to Directive 2010/75/EU, namely 1.2. Refining of mineral oil and gas. In particular, these BAT conclusions cover the following processes and activities: Activity Subactivities or processes included in activity Alkylation All alkylation processes: hydrofluoric acid (HF), sulphuric acid (H2SO4) and solid-acid Base oil production Deasphalting, aromatic extraction, wax processing and lubricant oil hydrofinishing Bitumen production All techniques from storage to final product additives Catalytic cracking All types of catalytic cracking units such as fluid catalytic cracking Catalytic reforming Continuous, cyclic and semi-regenerative catalytic reforming Coking Delayed and fluid coking processes. Coke calcination Cooling Cooling techniques applied in refineries Desalting Desalting of crude oil Combustion units for energy production Combustion units burning refinery fuels, excluding units using only conventional or commercial fuels Etherification Production of chemicals (e.g. alcohols and ethers such as MTBE, ETBE and TAME) used as motor fuels additives Gas separation Separation of light fractions of the crude oil e.g. refinery fuel gas (RFG), liquefied petroleum gas (LPG) Hydrogen consuming processes Hydrocracking, hydrorefining, hydrotreatments, hydroconversion, hydroprocessing and hydrogenation processes Hydrogen production Partial oxidation, steam reforming, gas heated reforming and hydrogen purification Isomerisation Isomerisation of hydrocarbon compounds C4, C5 and C6 Natural gas plants Natural gas (NG) processing including liquefaction of NG Polymerisation Polymerisation, dimerisation and condensation Primary distillation Atmospheric and vacuum distillation Product treatments Sweetening and final product treatments Storage and handling of refinery materials Storage, blending, loading and unloading of refinery materials Visbreaking and other thermal conversions Thermal treatments such as visbreaking or thermal gas oil process Waste gas treatment Techniques to reduce or abate emissions to air Waste water treatment Techniques to treat waste water prior to release Waste management Techniques to prevent or reduce the generation of waste These BAT conclusions do not address the following activities or processes: Other reference documents which may be relevant for the activities covered by these BAT conclusions are the following: Reference document Subject Common Waste Water and Waste Gas Treatment/Management Systems in the Chemical Sector (CWW) Waste water management and treatment techniques Industrial Cooling Systems (ICS) Cooling processes Economics and Cross-media Effects (ECM) Economics and cross-media effects of techniques Emissions from Storage (EFS) Storage, blending, loading and unloading of refinery materials Energy Efficiency (ENE) Energy efficiency and integrated refinery management Large Combustion Plants (LCP) Combustion of conventional and commercial fuels Large Volume Inorganic Chemicals — Ammonia, Acids and Fertilisers Industries (LVIC-AAF) Steam reforming and hydrogen purification Large Volume Organic Chemical Industry (LVOC) Etherification process (MTBE, ETBE and TAME production) Waste Incineration (WI) Waste incineration Waste Treatment (WT) Waste treatment General Principles of Monitoring (MON) Monitoring of emissions to air and water
the exploration and production of crude oil and natural gas;
the transportation of crude oil and natural gas;
the marketing and distribution of products.
GENERAL CONSIDERATIONS
The techniques listed and described in these BAT conclusions are neither prescriptive nor exhaustive. Other techniques may be used that ensure at least an equivalent level of environmental protection. Unless otherwise stated, these BAT conclusions are generally applicable.
Averaging periods and reference conditions for emissions to air Table 1 Reference conditions for BAT-AELs concerning emissions to air
Unless stated otherwise, emission levels associated with the best available techniques (BAT-AELs) for emissions to air given in these BAT conclusions refer to concentrations, expressed as mass of emitted substance per volume of waste gas under the following standard conditions: dry gas, temperature of 273,15 K, pressure of 101,3 kPa. For continuous measurements BAT-AELs refer to monthly average values, which are the averages of all valid hourly average values measured over a period of one month For periodic measurements BAT-AELs refer to the average value of three spot samples of at least 30 minutes each For combustion units, catalytic cracking processes, and waste gas sulphur recovery units, reference conditions for oxygen are shown in Table 1. Activities Unit Oxygen reference conditions Combustion unit using liquid or gaseous fuels with the exception of gas turbines and engines mg/Nm3 3 % oxygen by volume Combustion unit using solid fuels mg/Nm3 6 % oxygen by volume Gas turbines (including combined cycle gas turbines — CCGT) and engines mg/Nm3 15 % oxygen by volume Catalytic cracking process (regenerator) mg/Nm3 3 % oxygen by volume Waste gas sulphur recovery unit mg/Nm3 3 % oxygen by volume
Conversion of emissions concentration to reference oxygen level
The formula for calculating the emissions concentration at a reference oxygen level (see Table 1) is shown below. ER21OR21OMEM Where: ER (mg/Nm3) emissions concentration referred to the reference oxygen level OR OR (vol %) reference oxygen level EM (mg/Nm3) emissions concentration referred to the measured oxygen level OM OM (vol %) measured oxygen level.
Averaging periods and reference conditions for emissions to water
Unless stated otherwise, emission levels associated with the best available techniques (BAT-AELs) for emissions to water given in these BAT conclusions refer to values of concentration (mass of emitted substances per volume of water) expressed in mg/l. Unless stated otherwise, the averaging periods associated with the BAT-AELs are defined as follows: Daily average Average over a sampling period of 24 hours taken as a flow-proportional composite sample or, provided that sufficient flow stability is demonstrated, from a time-proportional sample Yearly/Monthly average Average of all daily averages obtained within a year/month, weighted according to the daily flows
DEFINITIONS
For the purpose of these BAT conclusions, the following definitions apply: Term used Definition Unit A segment/subpart of the installation in which a specific processing operation is conducted New unit A unit first permitted on the site of the installation following the publication of these BAT conclusions or a complete replacement of a unit on the existing foundations of the installation following the publication of these BAT conclusions Existing unit A unit which is not a new unit Process off-gas The collected gas generated by a process which must be treated e.g. in an acid gas removal unit and a sulphur recovery unit (SRU) Flue-gas The exhaust gas exiting a unit after an oxidation step, generally combustion (e.g. regenerator, Claus unit) Tail gas Common name of the exhaust gas from an SRU (generally Claus process) VOC Volatile organic compounds as defined in Article 3(45) of Directive 2010/75/EU NMVOC VOC excluding methane Diffuse VOC emissions Non-channelled VOC emissions that are not released via specific emission points such as stacks. They can result from area sources (e.g. tanks) or point sources (e.g. pipe flanges) NOX expressed as NO2 The sum of nitrogen oxide (NO) and nitrogen dioxide (NO2) expressed as NO2 SOX expressed as SO2 The sum of sulphur dioxide (SO2) and sulphur trioxide (SO3) expressed as SO2 H2S Hydrogen sulphide. Carbonyl sulphide and mercaptan are not included Hydrogen chloride expressed as HCl All gaseous chlorides expressed as HCl Hydrogen fluoride expressed as HF All gaseous fluorides expressed as HF FCC unit Fluid catalytic cracking: a conversion process for upgrading heavy hydrocarbons, using heat and a catalyst to break larger hydrocarbon molecules into lighter molecules SRU Sulphur recovery unit. See definition in Section 1.20.3 Refinery fuel Solid, liquid or gaseous combustible material from the distillation and conversion steps of the refining of crude oil. Examples are refinery fuel gas (RFG), syngas and refinery oils, pet coke RFG Refinery fuel gas: off-gases from distillation or conversion units used as a fuel Combustion unit Unit burning refinery fuels alone or with other fuels for the production of energy at the refinery site, such as boilers (except CO boilers), furnaces, and gas turbines. Continuous measurement Measurement using an automated measuring system (AMS) or a continuous emission monitoring system (CEMS) permanently installed on site Periodic measurement Determination of a measurand at specified time intervals using manual or automated reference methods Indirect monitoring of emissions to air Estimation of the emissions concentration in the flue-gas of a pollutant obtained through an appropriate combination of measurements of surrogate parameters (such as O2 content, sulphur or nitrogen content in the feed/fuel), calculations and periodic stack measurements. The use of emission ratios based on S content in the fuel is one example of indirect monitoring. Another example of indirect monitoring is the use of PEMS Predictive Emissions monitoring system (PEMS) System to determine the emissions concentration of a pollutant based on its relationship with a number of characteristic continuously monitored process parameters (e.g. fuel-gas consumption, air/fuel ratio) and fuel or feed quality data (e.g. the sulphur content) of an emission source Volatile liquid hydrocarbon compounds Petroleum derivatives with a Reid vapour pressure (RVP) of more than 4 kPa, such as naphtha and aromatics Recovery rate Percentage of NMVOC recovered from the streams conveyed into a vapour recovery unit (VRU)
1.1. General BAT conclusions for the refining of mineral oil and gas The process-specific BAT conclusions included in Sections 1.2 to 1.19 apply in addition to the general BAT conclusions mentioned in this section.
1.1.
1.1.1. Environmental management systems
1.1.1.
BAT 1. In order to improve the overall environmental performance of plants for the refining of mineral oil and gas, BAT is to implement and adhere to an environmental management system (EMS) that incorporates all of the following features:
BAT 1.
(i) commitment of the management, including senior management;
(ii) definition of an environmental policy that includes the continuous improvement for the installation by the management;
(iii) planning and establishing the necessary procedures, objectives and targets, in conjunction with financial planning and investment;
(iv) implementation of the procedures paying particular attention to:
(iv)
(a) structure and responsibility
(b) training, awareness and competence
(c) communication
(d) employee involvement
(e) documentation
(f) efficient process control
(g) maintenance programmes
(h) emergency preparedness and response
(i) safeguarding compliance with environmental legislation.
(v) checking performance and taking corrective action, paying particular attention to:
(v)
(a) monitoring and measurement (see also the reference document on the General Principles of Monitoring)
(b) corrective and preventive action
(c) maintenance of records
(d) independent (where practicable) internal and external auditing in order to determine whether or not the EMS conforms to planned arrangements and has been properly implemented and maintained;
(vi) review of the EMS and its continuing suitability, adequacy and effectiveness by senior management;
(vii) following the development of cleaner technologies;
(viii) consideration for the environmental impacts from the eventual decommissioning of the installation at the stage of designing a new plant, and throughout its operating life;
(ix) application of sectoral benchmarking on a regular basis.
Applicability
The scope (e.g. level of detail) and nature of the EMS (e.g. standardised or non-standardised) will generally be related to the nature, scale and complexity of the installation, and the range of environmental impacts it may have.
1.1.2.BAT 2.(i)a.b.c.(ii)a.b.c.(iii)a.b.
Energy efficiency In order to use energy efficiently, BAT is to use an appropriate combination of the techniques given below. Technique Description Design techniques Pinch analysis Methodology based on a systematic calculation of thermodynamic targets for minimising energy consumption of processes. Used as a tool for the evaluation of total systems designs Heat integration Heat integration of process systems ensures that a substantial proportion of the heat required in various processes is provided by exchanging heat between streams to be heated and streams to be cooled Heat and power recovery Use of energy recovery devices e.g.: Process control and maintenance techniques Process optimisation Automated controlled combustion in order to lower the fuel consumption per tonne of feed processed, often combined with heat integration for improving furnace efficiency Management and reduction of steam consumption Systematic mapping of drain valve systems in order to reduce steam consumption and optimise its use Use of energy benchmark Participation in ranking and benchmarking activities in order to achieve continuous improvement by learning from best practice Energy-efficient production techniques Use of combined heat and power System designed for the co-production (or the cogeneration) of heat (e.g. steam) and electric power from the same fuel Integrated gasification combined cycle (IGCC) Technique whose purpose is to produce steam, hydrogen (optional) and electric power from a variety of fuel types (e.g. heavy fuel oil or coke) with a high conversion efficiency
waste heat boilers
expanders/power recovery in the FCC unit
use of waste heat in district heating
1.1.3.BAT 3. Solid materials storage and handling In order to prevent or, where that is not practicable, to reduce dust emissions from the storage and handling of dusty materials, BAT is to use one or a combination of the techniques given below:
1.1.3.BAT 3.
(i) store bulk powder materials in enclosed silos equipped with a dust abatement system (e.g. fabric filter);
(ii) store fine materials in enclosed containers or sealed bags;
(iii) keep stockpiles of coarse dusty material wetted, stabilise the surface with crusting agents, or store under cover in stockpiles;
(iv) use road cleaning vehicles.
1.1.4.BAT 4.(i)(ii)(iii)(iv)(v)
Monitoring of emissions to air and key process parameters BAT is to monitor emissions to air by using the monitoring techniques with at least the minimum frequency given below and in accordance with EN standards. If EN standards are not available, BAT is to use ISO, national or other international standards that ensure the provision of data of an equivalent scientific quality. Description Unit Minimum frequency Monitoring technique SOX, NOX, and dust emissions Catalytic cracking Continuous Direct measurement Combustion units ≥ 100 MW and calcining units Continuous Direct measurement Combustion units of 50 to 100 MW Continuous Direct measurement or indirect monitoring Combustion units < 50 MW Once a year and after significant fuel changes Direct measurement or indirect monitoring Sulphur recovery units (SRU) Continuous for SO2 only Direct measurement or indirect monitoring NH3 emissions All units equipped with SCR or SNCR Continuous Direct measurement CO emissions Catalytic cracking and combustion units ≥ 100 MW Continuous Direct measurement Other combustion units Once every 6 months Direct measurement Metals emissions: Nickel (Ni), Antimony (Sb), Vanadium (V) Catalytic cracking Once every 6 months and after significant changes to the unit Direct measurement or analysis based on metals content in the catalyst fines and in the fuel Combustion units Polychlorinated dibenzodioxins/furans (PCDD/F) emissions Catalytic reformer Once a year or once a regeneration, whichever is longer Direct measurement
BAT 5. BAT is to monitor the relevant process parameters linked to pollutant emissions, at catalytic cracking and combustion units by using appropriate techniques and with at least the frequency given below. Description Minimum frequency Monitoring of parameters linked to pollutant emissions, e.g. O2 content in flue-gas, N and S content in fuel or feed Continuous for O2 content. For N and S content, periodic at a frequency based on significant fuel/feed changes
BAT 6. BAT is to monitor diffuse VOC emissions to air from the entire site by using all of the following techniques: The screening and quantification of site emissions by periodic campaigns with optical absorption-based techniques, such as differential absorption light detection and ranging (DIAL) or solar occultation flux (SOF) is a useful complementary technique.
BAT 6.
(i) sniffing methods associated with correlation curves for key equipment;
(ii) optical gas imaging techniques;
(iii) calculations of chronic emissions based on emissions factors periodically (e.g. once every two years) validated by measurements.
Description
See Section 1.20.6.
1.1.5.BAT 8. Table 2 BAT 9. BAT-associated emission levels for ammonia (NH3) emissions to air for a combustion or process unit where SCR or SNCR techniques are used
Operation of waste gas treatment systems In order to prevent and reduce ammonia (NH3) emissions to air when applying selective catalytic reduction (SCR) or selective non-catalytic reduction (SNCR) techniques, BAT is to maintain suitable operating conditions of the SCR or SNCR waste gas treatment systems, with the aim of limiting emissions of unreacted NH3. BAT-associated emission levels: See Table 2. Parameter BAT-AEL z(monthly average) mg/Nm3 Ammonia expressed as NH3 < 5 – 15 In order to prevent and reduce emissions to air when using a sour water steam stripping unit, BAT is to route the acid off-gases from this unit to an SRU or any equivalent gas treatment system. It is not BAT to directly incinerate the untreated sour water stripping gases.
1.1.5.
BAT 7. In order to prevent or reduce emissions to air, BAT is to operate the acid gas removal units, sulphur recovery units and all other waste gas treatment systems with a high availability and at optimal capacity.
BAT 7. Description
Special procedures can be defined for other than normal operating conditions, in particular:
(i) during start-up and shutdown operations;
(ii) during other circumstances that could affect the proper functioning of the systems (e.g. regular and extraordinary maintenance work and cleaning operations of the units and/or of the waste gas treatment system);
(iii) in case of insufficient waste gas flow or temperature which prevents the use of the waste gas treatment system at full capacity.
1.1.6.BAT 10.
Monitoring of emissions to water BAT is to monitor emissions to water by using the monitoring techniques with at least the frequency given in Table 3) and in accordance with EN standards. If EN standards are not available, BAT is to use ISO, national or other international standards that ensure the provision of data of an equivalent scientific quality.
1.1.7.BAT 11.(i)(ii)(iii)(iv)BAT 12.(i)(ii)(iii)BAT 13. Table 3 BAT-associated emission levels for direct waste water discharges from the refining of mineral oil and gas and monitoring frequencies associated with BAT
Emissions to water In order to reduce water consumption and the volume of contaminated water, BAT is to use all of the techniques given below. Technique Description Applicability Water stream integration Reduction of process water produced at the unit level prior to discharge by the internal reuse of water streams from e.g. cooling, condensates, especially for use in crude desalting Generally applicable for new units. For existing units, applicability may require a complete rebuilding of the unit or the installation Water and drainage system for segregation of contaminated water streams Design of an industrial site to optimise water management, where each stream is treated as appropriate, by e.g. routing generated sour water (from distillation, cracking, coking units, etc.) to appropriate pretreatment, such as a stripping unit Generally applicable for new units. For existing units, applicability may require a complete rebuilding of the unit or the installation Segregation of non-contaminated water streams (e.g. once-through cooling, rain water) Design of a site in order to avoid sending non-contaminated water to general waste water treatment and to have a separate release after possible reuse for this type of stream Generally applicable for new units. For existing units, applicability may require a complete rebuilding of the unit or the installation Prevention of spillages and leaks Practices that include the utilisation of special procedures and/or temporary equipment to maintain performances when necessary to manage special circumstances such as spills, loss of containment, etc. Generally applicable In order to reduce the emission load of pollutants in the waste water discharge to the receiving water body, BAT is to remove insoluble and soluble polluting substances by using all of the techniques given below. Technique Description Applicability Removal of insoluble substances by recovering oil See Section 1.21.2 Generally applicable Removal of insoluble substances by recovering suspended solids and dispersed oil See Section 1.21.2 Generally applicable Removal of soluble substances including biological treatment and clarification See Section 1.21.2 Generally applicable BAT-associated emission levels: See Table 3. When further removal of organic substances or nitrogen is needed, BAT is to use an additional treatment step as described in Section 1.21.2. Parameter Unit BAT-AEL (yearly average) Monitoring frequency and analytical method (standard) Hydrocarbon oil index (HOI) mg/l 0,1-2,5 Daily EN 9377- 2 Total suspended solids (TSS) mg/l 5-25 Daily Chemical oxygen demand (COD) mg/l 30-125 Daily BOD5 mg/l No BAT-AEL Weekly Total nitrogen, expressed as N mg/l 1-25 Daily Lead, expressed as Pb mg/l 0,005-0,030 Quarterly Cadmium, expressed as Cd mg/l 0,002-0,008 Quarterly Nickel, expressed as Ni mg/l 0,005-0,100 Quarterly Mercury, expressed as Hg mg/l 0,0001-0,001 Quarterly Vanadium mg/l No BAT-AEL Quarterly Phenol Index mg/l No BAT-AEL Monthly EN 14402 Benzene, toluene, ethyl benzene, xylene (BTEX) mg/l Benzene: 0,001-0,050 No BAT-AEL for T, E, X Monthly
1.1.8.BAT 14.BAT 15.(i)(ii)BAT 16.(i)(ii)
Waste generation and management In order to prevent or, where that is not practicable, to reduce waste generation, BAT is to adopt and implement a waste management plan that, in order of priority, ensures that waste is prepared for reuse, recycling, recovery or disposal. In order to reduce the amount of sludge to be treated or disposed of, BAT is to use one or a combination of the techniques given below. Technique Description Applicability Sludge pretreatment Prior to final treatment (e.g. in a fluidised bed incinerator), the sludges are dewatered and/or de-oiled (by e.g. centrifugal decanters or steam dryers) to reduce their volume and to recover oil from slop equipment Generally applicable Reuse of sludge in process units Certain types of sludge (e.g. oily sludge) can be processed in units (e.g. coking) as part of the feed due to their oil content Applicability is restricted to sludges that can fulfil the requirements to be processed in units with appropriate treatment In order to reduce the generation of spent solid catalyst waste, BAT is to use one or a combination of the techniques given below. Technique Description Spent solid catalyst management Scheduled and safe handling of the materials used as catalyst (e.g. by contractors) in order to recover or reuse them in off-site facilities. These operations depend on the type of catalyst and process Removal of catalyst from slurry decant oil Decanted oil sludge from process units (e.g. FCC unit) can contain significant concentrations of catalyst fines. These fines need to be separated prior to the reuse of decant oil as a feedstock
1.1.9.BAT 17.
Noise In order to prevent or reduce noise, BAT is to use one or a combination of the techniques given below:
(i) make an environmental noise assessment and formulate a noise management plan as appropriate to the local environment;
(ii) enclose noisy equipment/operation in a separate structure/unit;
(iii) use embankments to screen the source of noise;
(iv) use noise protection walls.
1.1.10.BAT 18.I.II.III.
BAT conclusions for integrated refinery management In order to prevent or reduce diffuse VOC emissions, BAT is to apply the techniques given below. Technique Description Applicability Techniques related to plant design Applicability may be limited for existing units Techniques related to plant installation and commissioning Applicability may be limited for existing units Techniques related to plant operation Use of a risk-based leak detection and repair (LDAR) programme in order to identify leaking components, and to repair these leaks. See Section 1.20.6 Generally applicable
1.1.10.BAT 18.I.
(i) limiting the number of potential emission sources
(ii) maximising inherent process containment features
(iii) selecting high integrity equipment
(iv) facilitating monitoring and maintenance activities by ensuring access to potentially leaking components
1.1.10.BAT 18.I.II.
(i) well-defined procedures for construction and assembly
(ii) robust commissioning and hand-over procedures to ensure that the plant is installed in line with the design requirements
1.2. BAT conclusions for the alkylation process
1.2.
1.2.1.BAT 20.(i)(ii)
Hydrofluoric acid alkylation process In order to reduce emissions to water from the hydrofluoric acid alkylation process, BAT is to use a combination of the techniques given below. Technique Description Applicability Precipitation/Neutralisation step Precipitation (with, e.g. calcium or aluminium-based additives) or neutralisation (where the effluent is indirectly neutralised with potassium hydroxide (KOH)) Generally applicable. Safety requirements due to the hazardous nature of hydrofluoric acid (HF) are to be considered Separation step The insoluble compounds produced at the first step (e.g. CaF2 or AlF3) are separated in e.g. a settlement basin Generally applicable
1.2.1.
BAT 19. In order to prevent hydrofluoric acid (HF) emissions to air from the hydrofluoric acid alkylation process, BAT is to use wet scrubbing with alkaline solution to treat incondensable gas streams prior to venting to flare.
BAT 19. Description
See Section 1.20.3.
Applicability:
The technique is generally applicable. Safety requirements, due to the hazardous nature of hydrofluoric acid, are to be considered
1.2.2.BAT 21.
Sulphuric acid alkylation process In order to reduce the emissions to water from the sulphuric acid alkylation process, BAT is to reduce the use of sulphuric acid by regenerating the spent acid and to neutralise the waste water generated by this process before routing to waste water treatment.
1.3.BAT 22.(i)(ii)(iii)(iv)
BAT conclusions for base oil production processes In order to prevent and reduce the emissions of hazardous substances to air and water from base oil production processes, BAT is to use one or a combination of the techniques given below. Technique Description Applicability Closed process with a solvent recovery Process where the solvent, after being used during base oil manufacturing (e.g. in extraction, dewaxing units), is recovered through distillation and stripping steps. See Section 1.20.7 Generally applicable Multi-effect extraction solvent-based process Solvent extraction process including several stages of evaporation (e.g. double or triple effect) for a lower loss of containment Generally applicable to new units. The use of a triple effect process may be restricted to non-fouling feed stocks Extraction unit processes using less hazardous substances Design (new plants) or implement changes (into existing) so that the plant operates a solvent extraction process with the use of a less hazardous solvent: e.g. converting furfural or phenol extraction into the n-methylpyrrolidone (NMP) process Generally applicable to new units. Converting existing units to another solvent-based process with different physico-chemical properties may require substantial modifications Catalytic processes based on hydrogenation Processes based on conversion of undesired compounds via catalytic hydrogenation similar to hydrotreatment. See Section 1.20.3 (Hydrotreatment) Generally applicable to new units
1.4.BAT 23.(i)(ii)
BAT conclusions for the bitumen production process In order to prevent and reduce emissions to air from the bitumen production process, BAT is to treat the gaseous overhead by using one of the techniques given below. Technique Description Applicability Thermal oxidation of gaseous overhead over 800 °C See Section 1.20.6 Generally applicable for the bitumen blowing unit Wet scrubbing of gaseous overhead See Section 1.20.3 Generally applicable for the bitumen blowing unit
1.5. BAT conclusions for the fluid catalytic cracking process
1.5.
BAT 24.I.(i)(ii)(iii)II.(i)(ii)(iii) Table 4 BAT-associated emission levels for NOX emissions to air from the regenerator in the catalytic cracking process
In order to prevent or reduce NOX emissions to air from the catalytic cracking process (regenerator), BAT is to use one or a combination of the techniques given below. Primary or process-related techniques, such as: Technique Description Applicability Process optimisation and use of promoters or additives Process optimisation Combination of operating conditions or practices aimed at reducing NOX formation, e.g. lowering the excess oxygen in the flue-gas in full combustion mode, air staging of the CO boiler in partial combustion mode, provided that the CO boiler is appropriately designed Generally applicable Low-NOX CO oxidation promoters Use of a substance that selectively promotes the combustion of CO only and prevents the oxidation of the nitrogen that contains intermediates to NOX: e.g. non-platinum promoters Applicable only in full combustion mode for the substitution of platinum-based CO promoters. Appropriate distribution of air in the regenerator may be required to obtain the maximum benefit Specific additives for NOX reduction Use of specific catalytic additives for enhancing the reduction of NO by CO Applicable only in full combustion mode in an appropriate design and with achievable oxygen excess. The applicability of copper-based NOX reduction additives may be limited by the gas compressor capacity Secondary or end-of-pipe techniques, such as: Technique Description Applicability Selective catalytic reduction (SCR) See Section 1.20.2 To avoid potential fouling downstream, additional filtering might be required upstream of the SCR. For existing units, the applicability may be limited by space availability Selective non-catalytic reduction (SNCR) See Section 1.20.2 For partial combustion FCCs with CO boilers, a sufficient residence time at the appropriate temperature is required. For full combustion FCCs without auxiliary boilers, additional fuel injection (e.g. hydrogen) may be required to match a lower temperature window Low temperature oxidation See Section 1.20.2 Need for additional scrubbing capacity. Ozone generation and the associated risk management need to be properly addressed. The applicability may be limited by the need for additional waste water treatment and related cross-media effects (e.g. nitrate emissions) and by an insufficient supply of liquid oxygen (for ozone generation). The applicability of the technique may be limited by space availability BAT-associated emission levels: See Table 4. Parameter Type of unit/combustion mode BAT-AEL (monthly average) mg/Nm3 NOX, expressed as NO2 New unit/all combustion mode < 30-100 Existing unit/full combustion mode < 100-300 Existing unit/partial combustion mode 100-400 The associated monitoring is in BAT 4.
BAT 25.I.(i)(ii)II.(i)(ii)(iii)(iv) Table 5 BAT-associated emission levels for dust emissions to air from the regenerator in the catalytic cracking process
In order to reduce dust and metals emissions to air from the catalytic cracking process (regenerator), BAT is to use one or a combination of the techniques given below. Primary or process-related techniques, such as: Technique Description Applicability Use of an attrition-resistant catalyst Selection of catalyst substance that is able to resist abrasion and fragmentation in order to reduce dust emissions Generally applicable provided the activity and selectivity of the catalyst are sufficient Use of low sulphur feedstock (e.g. by feedstock selection or by hydrotreatment of feed) Feedstock selection favours low sulphur feedstocks among the possible sources to be processed at the unit. Hydrotreatment aims at reducing the sulphur, nitrogen and metal contents of the feed. See Section 1.20.3 Requires sufficient availability of low sulphur feedstocks, hydrogen production and hydrogen sulphide (H2S) treatment capacity (e.g. amine and Claus units) Secondary or end-of-pipe techniques, such as: Technique Description Applicability Electrostatic precipitator (ESP) See Section 1.20.1 For existing units, the applicability may be limited by space availability Multistage cyclone separators See Section 1.20.1 Generally applicable Third stage blowback filter See Section 1.20.1 Applicability may be restricted Wet scrubbing See Section 1.20.3 The applicability may be limited in arid areas and in the case where the by-products from treatment (including e.g. waste water with high level of salts) cannot be reused or appropriately disposed of. For existing units, the applicability may be limited by space availability BAT-associated emission levels: See Table 5. Parameter Type of unit BAT-AEL (monthly average) mg/Nm3 Dust New unit 10-25 Existing unit 10-50 The associated monitoring is in BAT 4.
BAT 26.I.(i)(ii)II.(i)(ii) Table 6 BAT-associated emission levels for SO2 emissions to air from the regenerator in the catalytic cracking process
In order to prevent or reduce SOX emissions to air from the catalytic cracking process (regenerator), BAT is to use one or a combination of the techniques given below. Primary or process-related techniques, such as: Technique Description Applicability Use of SOX reducing catalyst additives Use of a substance that transfers the sulphur associated with coke from the regenerator back to the reactor. See description in 1.20.3 Applicability may be restricted by regenerator conditions design. Requires appropriate hydrogen sulphide abatement capacity (e.g. SRU) Use of low sulphur feedstock (e.g. by feedstock selection or by hydrotreatment of the feed) Feedstock selection favours low sulphur feedstocks among the possible sources to be processed at the unit. Hydrotreatment aims at reducing the sulphur, nitrogen and metal contents of the feed. See description in 1.20.3 Requires sufficient availability of low sulphur feedstocks, hydrogen production and hydrogen sulphide (H2S) treatment capacity (e.g. amine and Claus units) Secondary or end-of-pipe techniques, such as: Techniques Description Applicability Non-regenerative scrubbing Wet scrubbing or seawater scrubbing. See Section 1.20.3 The applicability may be limited in arid areas and in the case where the by-products from treatment (including e.g. waste water with high level of salts) cannot be reused or appropriately disposed of. For existing units, the applicability may be limited by space availability Regenerative scrubbing Use of a specific SOX absorbing reagent (e.g. absorbing solution) which generally enables the recovery of sulphur as a by-product during a regenerating cycle where the reagent is reused. See Section 1.20.3 The applicability is limited to the case where regenerated by-products can be sold. For existing units, the applicability may be limited by the existing sulphur recovery capacity as well as by space availability BAT-associated emission levels: See Table 6. Parameter Type of units/mode BAT-AEL (monthly average) mg/Nm3 SO2 New units ≤ 300 Existing units/full combustion < 100-800 Existing units/partial combustion 100-1200 The associated monitoring is in BAT 4.
BAT 27.(i)(ii)(iii) Table 7 BAT-associated emission levels for carbon monoxide emissions to air from the regenerator in the catalytic cracking process for partial combustion mode
In order to reduce carbon monoxide (CO) emissions to air from the catalytic cracking process (regenerator), BAT is to use one or a combination of the techniques given below. Technique Description Applicability Combustion operation control See Section 1.20.5 Generally applicable Catalysts with carbon monoxide (CO) oxidation promoters See Section 1.20.5 Generally applicable only for full combustion mode Carbon monoxide (CO) boiler See Section 1.20.5 Generally applicable only for partial combustion mode BAT-associated emission levels: See Table 7. Parameter Combustion mode BAT-AEL (monthly average) mg/Nm3 Carbon monoxide, expressed as CO Partial combustion mode ≤ 100 The associated monitoring is in BAT 4.
1.6.BAT 28.(i)(ii)a.b.c.
BAT conclusions for the catalytic reforming process In order to reduce emissions of polychlorinated dibenzodioxins/furans (PCDD/F) to air from the catalytic reforming unit, BAT is to use one or a combination of the techniques given below. Technique Description Applicability Choice of the catalyst promoter Use of catalyst promoter in order to minimise polychlorinated dibenzodioxins/furans (PCDD/F) formation during regeneration. See Section 1.20.7 Generally applicable Treatment of the regeneration flue-gas Regeneration gas recycling loop with adsorption bed Waste gas from the regeneration step is treated to remove chlorinated compounds (e.g. dioxins) Generally applicable to new units. For existing units the applicability may depend on the current regeneration unit design Wet scrubbing See Section 1.20.3 Not applicable to semi-regenerative reformers Electrostatic precipitator (ESP) See Section 1.20.1 Not applicable to semi-regenerative reformers
1.7.BAT 29.(i)(ii)(iii)(iv)BAT 31.(i)(ii)
BAT conclusions for the coking processes In order to reduce emissions to air from the coking production processes, BAT is to use one or a combination of the techniques given below: Primary or process-related techniques, such as: Technique Description Applicability Collection and recycling of coke fines Systematic collection and recycling of coke fines generated during the whole coking process (drilling, handling, crushing, cooling, etc.) Generally applicable Handling and storage of coke according to BAT 3 See BAT 3 Generally applicable Use of a closed blowdown system Arrestment system for pressure relief from the coke drums Generally applicable Recovery of gas (including the venting prior to the drum being opened to atmosphere) as a component of refinery fuel gas (RFG) Carrying venting from the coke drum to the gas compressor to recover as RFG, rather than flaring. For the flexicoking process, a conversion step (to convert the carbonyl sulphide (COS) into H2S) is needed prior to treating the gas from the coking unit For existing units, the applicability of the techniques may be limited by space availability In order to reduce SOX emissions to air from the calcining of green coke process, BAT is to use one or a combination of the techniques given below. Technique Description Applicability Non-regenerative scrubbing Wet scrubbing or seawater scrubbing. See Section 1.20.3 The applicability may be limited in arid areas and in the case where the by-products from treatment (including e.g. waste water with high level of salts) cannot be reused or appropriately disposed of. For existing units, the applicability may be limited by space availability Regenerative scrubbing Use of a specific SOX absorbing reagent (e.g. absorbing solution) which generally enables the recovery of sulphur as a by-product during a regenerating cycle where the reagent is reused. See Section 1.20.3 The applicability is limited to the case where regenerated by-products can be sold. For existing units, the applicability may be limited by the existing sulphur recovery capacity as well as by space availability
1.7.BAT 29.(i)(ii)(iii)(iv)
BAT 30. In order to reduce NOX emissions to air from the calcining of green coke process, BAT is to use selective non-catalytic reduction (SNCR).
BAT 30. Description
See Section 1.20.2.
Applicability
The applicability of the SNCR technique (especially with respect to residence time and temperature window) may be restricted due to the specificity of the calcining process.
1.7.BAT 29.(i)(ii)(iii)(iv)BAT 31.(i)(ii)
BAT 32.(i)(ii) Table 8 BAT-associated emission levels for dust emissions to air from a unit for the calcining of green coke
In order to reduce dust emissions to air from the calcining of green coke process, BAT is to use a combination of the techniques given below. Technique Description Applicability Electrostatic precipitator (ESP) See Section 1.20.1 For existing units, the applicability may be limited by space availability. For graphite and anode coke calcining production, the applicability may be restricted due to the high resistivity of the coke particles Multistage cyclone separators See Section 1.20.1 Generally applicable BAT-associated emission levels: See Table 8 Parameter BAT-AEL (monthly average) mg/Nm3 Dust 10-50 The associated monitoring is in BAT 4.
1.8.BAT 33.(i)(ii)(iii)
BAT conclusions for the desalting process In order to reduce water consumption and emissions to water from the desalting process, BAT is to use one or a combination of the techniques given below. Technique Description Applicability Recycling water and optimisation of the desalting process An ensemble of good desalting practices aiming at increasing the efficiency of the desalter and reducing wash water usage e.g. using low shear mixing devices, low water pressure. It includes the management of key parameters for washing (e.g. good mixing) and separation (e.g. pH, density, viscosity, electric field potential for coalescence) steps Generally applicable Multistage desalter Multistage desalters operate with water addition and dehydration, repeated through two stages or more for achieving a better efficiency in the separation and therefore less corrosion in further processes Applicable for new units Additional separation step An additional enhanced oil/water and solid/water separation designed for reducing the charge of oil to the waste water treatment plant and recycling it to the process. This includes, e.g. settling drum, the use of optimum interface level controllers Generally applicable
1.9. BAT conclusions for the combustion units
1.9.
BAT 34.I.(i)(a)(b)(ii)(a)(b)(c)(d)(e)II.(i)(ii)(iii)(iv) Table 9 Table 10 Table 11 BAT-associated emission levels for NOX emissions to air from a gas turbine BAT-associated emission levels for NOX emissions to air from a gas-fired combustion unit, with the exception of gas turbines BAT-associated emission levels for NOX emissions to air from a multi-fuel fired combustion unit with the exception of gas turbines
In order to prevent or reduce NOX emissions to air from the combustion units, BAT is to use one or a combination of the techniques given below. Primary or process-related techniques, such as: Technique Description Applicability Selection or treatment of fuel Use of gas to replace liquid fuel Gas generally contains less nitrogen than liquid and its combustion leads to a lower level of NOX emissions. See Section 1.20.3 The applicability may be limited by the constraints associated with the availability of low sulphur gas fuels, which may be impacted by the energy policy of the Member State Use of low nitrogen refinery fuel oil (RFO) e.g. by RFO selection or by hydrotreatment of RFO Refinery fuel oil selection favours low nitrogen liquid fuels among the possible sources to be used at the unit. Hydrotreatment aims at reducing the sulphur, nitrogen and metal contents of the fuel. See Section 1.20.3 Applicability is limited by the availability of low nitrogen liquid fuels, hydrogen production and hydrogen sulphide (H2S) treatment capacity (e.g. amine and Claus units) Combustion modifications Staged combustion: See Section 1.20.2 Fuel staging for mixed or liquid firing may require a specific burner design Optimisation of combustion See Section 1.20.2 Generally applicable Flue-gas recirculation See Section 1.20.2 Applicable through the use of specific burners with internal recirculation of the flue-gas. The applicability may be restricted to retrofitting external flue-gas recirculation to units with a forced/induced draught mode of operation Diluent injection See Section 1.20.2 Generally applicable for gas turbines where appropriate inert diluents are available Use of low-NOX burners (LNB) See Section 1.20.2 Generally applicable for new units taking into account, the fuel-specific limitation (e.g. for heavy oil). For existing units, applicability may be restricted by the complexity caused by site-specific conditions e.g. furnaces design, surrounding devices. In very specific cases, substantial modifications may be required. The applicability may be restricted for furnaces in the delayed coking process, due to possible coke generation in the furnaces. In gas turbines, the applicability is restricted to low hydrogen content fuels (generally < 10 %) Secondary or end-of-pipe techniques, such as: Technique Description Applicability Selective catalytic reduction (SCR) See Section 1.20.2 Generally applicable for new units. For existing units, the applicability may be constrained due to the requirements for significant space and optimal reactant injection Selective non-catalytic reduction (SNCR) See Section 1.20.2 Generally applicable for new units. For existing units, the applicability may be constrained by the requirement for the temperature window and the residence time to be reached by reactant injection Low temperature oxidation See Section 1.20.2 The applicability may be limited by the need for additional scrubbing capacity and by the fact that ozone generation and the associated risk management need to be properly addressed. The applicability may be limited by the need for additional waste water treatment and related cross-media effects (e.g. nitrate emissions) and by an insufficient supply of liquid oxygen (for ozone generation). For existing units, the applicability of the technique may be limited by space availability SNOX combined technique See Section 1.20.4 Applicable only for high flue-gas (e.g. > 800000 Nm3/h) flow and when combined NOX and SOX abatement is needed BAT-associated emission levels: See Table 9, Table 10 and Table 11. Parameter Type of equipment BAT-AEL (monthly average) mg/Nm3 at 15 % O2 NOX expressed as NO2 Gas turbine (including combined cycle gas turbine — CCGT) and integrated gasification combined cycle turbine (IGCC)) 40-120 (existing turbine) 20-50 (new turbine) The associated monitoring is in BAT 4. Parameter Type of combustion BAT-AEL (monthly average) mg/Nm3 NOX expressed as NO2 Gas firing 30-150 for existing unit 30-100 for new unit The associated monitoring is in BAT 4. Parameter Type of combustion BAT-AEL (monthly average) mg/Nm3 NOX expressed as NO2 Multi-fuel fired combustion unit 30-300 for existing unit The associated monitoring is in BAT 4.
air staging
fuel staging
BAT 35.I.(i)(a)(b)(ii)(a)(b)II.(i)(ii)(iii)(iv) Table 12 BAT-associated emission levels for dust emissions to air from a multi-fuel fired combustion unit with the exception of gas turbines
In order to prevent or reduce dust and metal emissions to air from the combustion units, BAT is to use one or a combination of the techniques given below. Primary or process-related techniques, such as: Technique Description Applicability Selection or treatment of fuel Use of gas to replace liquid fuel Gas instead of liquid combustion leads to lower level of dust emissions See Section 1.20.3 The applicability may be limited by the constraints associated with the availability of low sulphur fuels such as natural gas, which may be impacted by the energy policy of the Member State Use of low sulphur refinery fuel oil (RFO) e.g. by RFO selection or by hydrotreatment of RFO Refinery fuel oil selection favours low sulphur liquid fuels among the possible sources to be used at the unit. Hydrotreatment aims at reducing the sulphur, nitrogen and metal contents of the fuel. See Section 1.20.3 The applicability may be limited by the availability of low sulphur liquid fuels, hydrogen production and the hydrogen sulphide (H2S) treatment capacity (e.g. amine and Claus units) Combustion modifications Optimisation of combustion See Section 1.20.2 Generally applicable to all types of combustion Atomisation of liquid fuel Use of high pressure to reduce the droplet size of liquid fuel. Recent optimal burner designs generally include steam atomisation Generally applicable to liquid fuel firing Secondary or end-of-pipe techniques, such as: Technique Description Applicability Electrostatic precipitator (ESP) See Section 1.20.1 For existing units, the applicability may be limited by space availability Third stage blowback filter See Section 1.20.1 Generally applicable Wet scrubbing See Section 1.20.3 The applicability may be limited in arid areas and in the case where the by-products from treatment (including e.g. waste water with a high level of salt) cannot be reused or appropriately disposed of. For existing units, the applicability of the technique may be limited by space availability Centrifugal washers See Section 1.20.1 Generally applicable BAT-associated emission levels: See Table 12. Parameter Type of combustion BAT-AEL (monthly average) mg/Nm3 Dust Multi-fuel firing 5-50 for existing unit 5-25 for new unit < 50 MW The associated monitoring is in BAT 4.
BAT 36.I.(i)(ii)(iii)II.(i)(ii)(iii) Table 13 Table 14 BAT-associated emission levels for SO2 emissions to air from a combustion unit firing refinery fuel gas (RFG), with the exception of gas turbines BAT-associated emission levels for SO2 emissions to air from multi-fuel fired combustion units, with the exception of gas turbines and stationary gas engines This BAT-AEL refers to the weighted average emissions from existing multi-fuel fired combustion units within the refinery, with the exception of gas turbines and stationary gas engines.
In order to prevent or reduce SOX emissions to air from the combustion units, BAT is to use one or a combination of the techniques given below. Primary or process-related techniques based on a selection or a treatment of the fuel, such as: Technique Description Applicability Use of gas to replace liquid fuel See Section 1.20.3 The applicability may be limited by the constraints associated with the availability of low sulphur fuels such as natural gas, which may be impacted by the energy policy of the Member State Treatment of refinery fuel gas (RFG) Residual H2S concentration in RFG depends on the treatment process parameter, e.g. the amine-scrubbing pressure. See Section 1.20.3 For low calorific gas containing carbonyl sulphide (COS) e.g. from coking units, a converter may be required prior to H2S removal Use of low sulphur refinery fuel oil (RFO) e.g. by RFO selection or by hydrotreatment of RFO Refinery fuel oil selection favours low sulphur liquid fuels among the possible sources to be used at the unit. Hydrotreatment aims at reducing the sulphur, nitrogen and metal contents of the fuel. See Section 1.20.3 The applicability is limited by the availability of low sulphur liquid fuels, hydrogen production and the hydrogen sulphide (H2S) treatment capacity (e.g. amine and Claus units) Secondary or end-of-pipe techniques: Technique Description Applicability Non-regenerative scrubbing Wet scrubbing or seawater scrubbing. See Section 1.20.3 The applicability may be limited in arid areas and in the case where the by-products from treatment (including e.g. waste water with high level of salts) cannot be reused or appropriately disposed of. For existing units, the applicability of the technique may be limited by space availability Regenerative scrubbing Use of a specific SOX absorbing reagent (e.g. absorbing solution) which generally enables the recovery of sulphur as a by-product during a regenerating cycle where the reagent is reused. See Section 1.20.3 The applicability is limited to the case where regenerated by-products can be sold. Retrofitting to existing units may be limited by the existing sulphur recovery capacity. For existing units, the applicability of the technique may be limited by space availability SNOX combined technique See Section 1.20.4 Applicable only for high flue-gas (e.g. > 800000 Nm3/h) flow and when combined NOX and SOX abatement is required BAT-associated emission levels: See Table 13 and Table 14. Parameter BAT-AEL (monthly average) mg/Nm3 SO2 5-35 The associated monitoring is in BAT 4. Parameter BAT-AEL (monthly average) mg/Nm3 SO2 35-600 The associated monitoring is in BAT 4.
BAT 37. Table 15 BAT-associated emission levels for carbon monoxide emissions to air from a combustion unit
In order to reduce carbon monoxide (CO) emissions to air from the combustion units, BAT is to use a combustion operation control. BAT-associated emission levels: See Table 15. Parameter BAT-AEL (monthly average) mg/Nm3 Carbon monoxide, expressed as CO ≤ 100 The associated monitoring is in BAT 4.
Description
See Section 1.20.5.
1.10.BAT 38.BAT 39.
BAT conclusions for the etherification process In order to reduce emissions to air from the etherification process, BAT is to ensure the appropriate treatment of process off-gases by routing them to the refinery fuel gas system. In order to prevent upset of the biotreatment, BAT is to use a storage tank and an appropriate unit production plan management to control the toxic components dissolved content (e.g. methanol, formic acid, ethers) of the waste water stream prior to final treatment.
1.11.BAT 40. BAT conclusions for the isomerisation process In order to reduce emissions to air of chlorinated compounds, BAT is to optimise the use of chlorinated organic compounds used to maintain catalyst activity when such a process is in place or to use non-chlorinated catalytic systems.
1.12.BAT 41.BAT 42.BAT 43.
BAT conclusions for the natural gas refinery In order to reduce sulphur dioxide emissions to air from the natural gas plant, BAT is to apply BAT 54. In order to reduce nitrogen oxides (NOX) emissions to air from the natural gas plant, BAT is to apply BAT 34 In order to prevent emissions of mercury when present in raw natural gas, BAT is to remove the mercury and recover the mercury-containing sludge for waste disposal.
1.13.BAT 45. BAT conclusions for the distillation process In order to prevent or reduce water pollution from the distillation process, BAT is to route sour water to the stripping unit.
1.13.
BAT 44. In order to prevent or reduce waste water flow generation from the distillation process, BAT is to use liquid ring vacuum pumps or surface condensers.
BAT 44. Applicability
May not be applicable in some retrofit cases. For new units, vacuum pumps, either in or not in combination with steam ejectors, may be needed to achieve a high vacuum (10 mm Hg). Also, a spare should be available in case the vacuum pump fails.
1.13.BAT 45.
BAT 46. In order to prevent or reduce emissions to air from distillation units, BAT is to ensure the appropriate treatment of process off-gases, especially incondensable off-gases, by acid gas removal prior to further use.
BAT 46. Applicability
Generally applicable for crude and vacuum distillation units. May not be applicable for stand-alone lubricant and bitumen refineries with emissions of less than 1 t/d of sulphur compounds. In specific refinery configurations, applicability may be restricted, due to the need for e.g. large piping, compressors or additional amine treating capacity.
1.14.BAT 48. BAT conclusions for the products treatment process In order to reduce waste and waste water generation when a products treatment process using caustic is in place, BAT is to use cascading caustic solution and a global management of spent caustic, including recycling after appropriate treatment, e.g. by stripping.
1.14.
BAT 47. In order to reduce emissions to air from the products treatment process, BAT is to ensure the appropriate disposal of off-gases, especially odorous spent air from sweetening units, by routing them to destruction, e.g. by incineration.
BAT 47. Applicability
Generally applicable to products treatment processes where the gas streams can be safely processed to the destruction units. May not be applicable to sweetening units, due to safety reasons.
1.15.BAT 50.(i)(ii)BAT 51.(i)(ii)(iii)(iv)
BAT conclusions for storage and handling processes In order to reduce VOC emissions to air from the storage of volatile liquid hydrocarbon compounds, BAT is to use one or a combination of the techniques given below. Technique Description Applicability Manual crude oil tank cleaning Oil tank cleaning is performed by workers entering the tank and removing sludge manually Generally applicable Use of a closed-loop system For internal inspections, tanks are periodically emptied, cleaned and rendered gas-free. This cleaning includes dissolving the tank bottom. Closed-loop systems that can be combined with end-of-pipe mobile abatement techniques prevent or reduce VOC emissions The applicability may be limited by e.g. the type of residues, tank roof construction or tank materials In order to prevent or reduce emissions to soil and groundwater from the storage of liquid hydrocarbon compounds, BAT is to use one or a combination of the techniques given below. Technique Description Applicability Maintenance programme including corrosion monitoring, prevention and control A management system including leak detection and operational controls to prevent overfilling, inventory control and risk-based inspection procedures on tanks at intervals to prove their integrity, and maintenance to improve tank containment. It also includes a system response to spill consequences to act before spills can reach the groundwater. To be especially reinforced during maintenance periods Generally applicable Double bottomed tanks A second impervious bottom that provides a measure of protection against releases from the first material Generally applicable for new tanks and after overhaul of existing tanks Impervious membrane liners A continuous leak barrier under the entire bottom surface of the tank Generally applicable for new tanks and after an overhaul of existing tanks Sufficient tank farm bund containment A tank farm bund is designed to contain large spills potentially caused by a shell rupture or overfilling (for both environmental and safety reasons). Size and associated building rules are generally defined by local regulations Generally applicable
1.15.
BAT 49. In order to reduce VOC emissions to air from the storage of volatile liquid hydrocarbon compounds, BAT is to use floating roof storage tanks equipped with high efficiency seals or a fixed roof tank connected to a vapour recovery system.
BAT 49. Description
High efficiency seals are specific devices for limiting losses of vapour, e.g. improved primary seals, additional multiple (secondary or tertiary) seals (according to quantity emitted).
Applicability
The applicability of high efficiency seals may be restricted for retrofitting tertiary seals in existing tanks.
1.15.BAT 50.(i)(ii)BAT 51.(i)(ii)(iii)(iv)
BAT 52. Table 16 BAT-associated emission levels for non-methane VOC and benzene emissions to air from loading and unloading operations of volatile liquid hydrocarbon compounds
In order to prevent or reduce VOC emissions to air from loading and unloading operations of volatile liquid hydrocarbon compounds, BAT is to use one or a combination of the techniques given below to achieve a recovery rate of at least 95 %. Technique Description Applicability Vapour recovery by: See Section 1.20.6 Generally applicable to loading/unloading operations where annual throughput is > 5000 m3/yr. Not applicable to loading/unloading operations for sea-going vessels with an annual throughput < 1 million m3/yr BAT-associated emission levels: See Table 16. Parameter BAT-AEL (hourly average) NMVOC 0,15-10 g/Nm3 Benzene < 1 mg/Nm3
(i) Condensation
(ii) Absorption
(iii) Adsorption
(iv) Membrane separation
(v) Hybrid systems
1.16.BAT 53. BAT conclusions for visbreaking and other thermal processes In order to reduce emissions to water from visbreaking and other thermal processes, BAT is to ensure the appropriate treatment of waste water streams by applying the techniques of BAT 11.
1.17. BAT conclusions for waste gas sulphur treatment
1.17.
BAT 54.(i)(ii)(iii) Table 17 BAT-associated environmental performance levels for a waste gas sulphur (H2S) recovery system
In order to reduce sulphur emissions to air from off-gases containing hydrogen sulphides (H2S), BAT is to use all of the techniques given below. Technique Description Applicability Acid gas removal e.g. by amine treating See Section 1.20.3 Generally applicable Sulphur recovery unit (SRU), e.g. by Claus process See Section 1.20.3 Generally applicable Tail gas treatment unit (TGTU) See Section 1.20.3 For retrofitting existing SRU, the applicability may be limited by the SRU size and configuration of the units and the type of sulphur recovery process already in place BAT-associated environmental performance levels (BAT-AEPL): See Table 17. BAT-associated environmental performance level (monthly average) Acid gas removal Achieve hydrogen sulphides (H2S) removal in the treated RFG in order to meet gas firing BAT-AEL for BAT 36 Sulphur recovery efficiency New unit: 99,5 – > 99,9 % Existing unit: ≥ 98,5 % The associated monitoring is described in BAT 4.
1.18.BAT 55.BAT 56.(i)(ii)(iii)(iv)
BAT conclusions for flares In order to prevent emissions to air from flares, BAT is to use flaring only for safety reasons or for non-routine operational conditions (e.g. start-ups, shutdown). In order to reduce emissions to air from flares when flaring is unavoidable, BAT is to use the techniques given below. Technique Description Applicability Correct plant design See Section 1.20.7 Applicable to new units. Flare gas recovery system may be retrofitted in existing units Plant management See Section 1.20.7 Generally applicable Correct flaring devices design See Section 1.20.7 Applicable to new units Monitoring and reporting See Section 1.20.7 Generally applicable
1.19. BAT conclusions for integrated emission management
1.19.
BAT 57. In order to achieve an overall reduction of NOX emissions to air from combustion units and fluid catalytic cracking (FCC) units, BAT is to use an integrated emission management technique as an alternative to applying BAT 24 and BAT 34.
BAT 57. Description Notes: 1.2.3.
The technique consists of managing NOX emissions from several or all combustion units and FCC units on a refinery site in an integrated manner, by implementing and operating the most appropriate combination of BAT across the different units concerned and monitoring the effectiveness thereof, in such a way that the resulting total emissions are equal to or lower than the emissions that would be achieved through a unit-by-unit application of the BAT-AELs referred to in BAT 24 and BAT 34. This technique is especially suitable to oil refining sites: BAT-associated emission levels: See Table 18. In addition, for each new combustion unit or new FCC unit included in the integrated emission management system, the BAT-AELs set out under BAT 24 and BAT 34 remain applicable. The applicable reference conditions for oxygen are those specified in Table 1. The weighing of the emission levels of the individual units is done on the basis of the flue-gas flow rate of the unit concerned, expressed as a monthly average value (Nm3/hour), which is representative for the normal operation of that unit within the refinery installation (applying the reference conditions under Note 1). In case of substantial and structural fuel changes which are affecting the applicable BAT-AEL for a unit or other substantial and structural changes in the nature or functioning of the units concerned, or in case of their replacement or extension or the addition of combustion units or FCC units, the BAT-AEL defined in Table 18 needs to be adjusted accordingly. Monitoring associated with BAT 57 BAT for monitoring emissions of NOx under an integrated emission management technique is as in BAT 4, complemented with the following:
with a recognised site complexity, multiplicity of combustion and process units interlinked in terms of their feedstock and energy supply;
with frequent process adjustments required in function of the quality of the crude received;
with a technical necessity to use a part of process residues as internal fuels, causing frequent adjustments of the fuel mix according to process requirements.
Description
Table 18 BAT-associated emission levels for NOx emissions to air when applying BAT 57
The BAT-AEL for NOx emissions from the units concerned by BAT 57, expressed in mg/Nm3 as a monthly average value, is equal to or less than the weighted average of the NOx concentrations (expressed in mg/Nm3 as a monthly average) that would be achieved by applying in practice at each of those units techniques that would enable the units concerned to meet the following: This BAT-AEL is expressed by the following formula: Σ flue gas flow rate of the unit concernedNOXconcentration that would be achieved for that unitΣflue gas flow rate of all units concerned
(a) for catalytic cracking process (regenerator) units: the BAT-AEL range set out in Table 4 (BAT 24);
(b) for combustion units burning refinery fuels alone or simultaneously with other fuels: the BAT-AEL ranges set out in Tables 9, 10 and 11 (BAT 34).
a monitoring plan including a description of the processes monitored, a list of the emission sources and source streams (products, waste gases) monitored for each process and a description of the methodology (calculations, measurements) used and the underlying assumptions and associated level of confidence;
continuous monitoring of the flue-gas flow rates of the units concerned, either through direct measurement or by an equivalent method;
a data management system for collecting, processing and reporting all monitoring data needed to determine the emissions from the sources covered by the integrated emission management technique.
BAT 58. In order to achieve an overall reduction of SO2 emissions to air from combustion units, fluid catalytic cracking (FCC) units and waste gas sulphur recovery units, BAT is to use an integrated emission management technique as an alternative to applying BAT 26, BAT 36 and BAT 54.
BAT 58. Description Notes: 1.2.3.
The technique consists of managing SO2 emissions from several or all combustion units, FCC units and waste gas sulphur recovery units on a refinery site in an integrated manner, by implementing and operating the most appropriate combination of BAT across the different units concerned and monitoring the effectiveness thereof, in such a way that the resulting total emissions are equal to or lower than the emissions that would be achieved through a unit-by-unit application of the BAT-AELs referred to in BAT 26 and BAT 36 as well as the BAT-AEPL set out under BAT 54. This technique is especially suitable to oil refining sites: BAT associated emission level: See Table 19. In addition, for each new combustion unit, new FCC unit or new waste gas sulphur recovery unit included in the integrated emission management system, the BAT-AELs set out under BAT 26 and BAT 36 and the BAT-AEPL set out under BAT 54 remain applicable. The applicable reference conditions for oxygen are those specified in Table 1. The weighing of the emission levels of the individual units is done on the basis of the flue-gas flow rate of the unit concerned, expressed as the monthly average value (Nm3/hour), which is representative for the normal operation of that unit within the refinery installation (applying the reference conditions under Note 1). In case of substantial and structural fuel changes which are affecting the applicable BAT-AEL for a unit or other substantial and structural changes in the nature or functioning of the units concerned, or in case of their replacement, extension or the addition of combustion, FCC, or waste gas sulphur recovery units, the BAT-AEL defined in Table 19 needs to be adjusted accordingly. Monitoring associated with BAT 58 BAT for monitoring emissions of SO2 under an integrated emission management approach is as in BAT 4, complemented with the following:
with a recognised site complexity, multiplicity of combustion and process units interlinked in terms of their feedstock and energy supply;
with frequent process adjustments required in function of the quality of the crude received;
with a technical necessity to use a part of process residues as internal fuels, causing frequent adjustments of the fuel mix according to process requirements.
Description
Table 19 BAT-associated emission levels for SO2 emissions to air when applying BAT 58
The BAT-AEL for SO2 emissions from the units concerned by BAT 58, expressed in mg/Nm3 as a monthly average value, is equal to or less than the weighted average of the SO2 concentrations (expressed in mg/Nm3 as a monthly average) that would be achieved by applying in practice at each of those units techniques that would enable the units concerned to meet the following: This BAT-AEL is expressed by the following formula: Σ flue gas flow rate of the unit concernedSO2concentration that would be achieved for that unitΣflue gas flow rate of all units concerned
(a) for catalytic cracking process (regenerator) units: the BAT-AEL ranges set out in Table 6 (BAT 26);
(b) for combustion units burning refinery fuels alone or simultaneously with other fuels: the BAT-AEL ranges set out in Table 13 and in Table 14 (BAT 36); and
(c) for waste gas sulphur recovery units: the BAT-AEPL ranges set out in Table 17 (BAT 54).
a monitoring plan including a description of the processes monitored, a list of the emission sources and source streams (products, waste gases) monitored for each process and a description of the methodology (calculations, measurements) used and the underlying assumptions and associated level of confidence;
continuous monitoring of the flue-gas flow rates of the units concerned, either through direct measurement or by an equivalent method;
a data management system for collecting, processing and reporting all monitoring data needed to determine the emissions from the sources covered by the integrated emission management technique.
GLOSSARY
1.20. Description of techniques for the prevention and control of emissions to air
1.20.
1.20.1. Dust Technique Description Electrostatic precipitator (ESP) Electrostatic precipitators operate such that particles are charged and separated under the influence of an electrical field. Electrostatic precipitators are capable of operating under a wide range of conditions. Abatement efficiency may depend on the number of fields, residence time (size), catalyst properties and upstream particles removal devices. At FCC units, 3-field ESPs and 4-field ESPs are commonly used. ESPs may be used on a dry mode or with ammonia injection to improve the particle collection. For the calcining of green coke, the ESP capture efficiency may be reduced due to the difficulty for coke particles to be electrically charged Multistage cyclone separators Cyclonic collection device or system installed following the two stages of cyclones. Generally known as a third stage separator, common configuration consists of a single vessel containing many conventional cyclones or improved swirl-tube technology. For FCC, performance mainly depends on the particle concentration and size distribution of the catalyst fines downstream of the regenerator internal cyclones Centrifugal washers Centrifugal washers combine the cyclone principle and an intensive contact with water e.g. venturi washer Third stage blowback filter Reverse flow (blowback) ceramic or sintered metal filters where, after retention at the surface as a cake, the solids are dislodged by initiating a reverse flow. The dislodged solids are then purged from the filter system
1.20.2. Nitrogen oxides (NOX) Technique Description Combustion modifications Staged combustion Flue-gas recirculation Reinjection of waste gas from the furnace into the flame to reduce the oxygen content and therefore the temperature of the flame. Special burners using the internal recirculation of combustion gases to cool the root of the flames and reduce the oxygen content in the hottest part of the flames Use of low-NOX burners (LNB) The technique (including ultra-low-NOX burners) is based on the principles of reducing peak flame temperatures, delaying but completing the combustion and increasing the heat transfer (increased emissivity of the flame). It may be associated with a modified design of the furnace combustion chamber. The design of ultra-low-NOX burners (ULNB) includes combustion staging (air/fuel) and flue-gas recirculation. Dry low-NOX burners (DLNB) are used for gas turbines Optimisation of combustion Based on permanent monitoring of appropriate combustion parameters (e.g. O2, CO content, fuel to air (or oxygen) ratio, unburnt components), the technique uses control technology for achieving the best combustion conditions Diluent injection Inert diluents, e.g. flue-gas, steam, water, nitrogen added to combustion equipment reduce the flame temperature and consequently the concentration of NOX in the flue-gases Selective catalytic reduction (SCR) The technique is based on the reduction of NOX to nitrogen in a catalytic bed by reaction with ammonia (in general aqueous solution) at an optimum operating temperature of around 300-450 °C. One or two layers of catalyst may be applied. A higher NOX reduction is achieved with the use of higher amounts of catalyst (two layers) Selective non-catalytic reduction (SNCR) The technique is based on the reduction of NOX to nitrogen by reaction with ammonia or urea at a high temperature. The operating temperature window must be maintained between 900 °C and 1050 °C for optimal reaction Low temperature NOX oxidation The low temperature oxidation process injects ozone into a flue-gas stream at optimal temperatures below 150 °C, to oxidise insoluble NO and NO2 to highly soluble N2O5. The N2O5 is removed in a wet scrubber by forming dilute nitric acid waste water that can be used in plant processes or neutralised for release and may need additional nitrogen removal
Air staging — involves substoichiometric firing in a first step and the subsequent addition of the remaining air or oxygen into the furnace to complete combustion
Fuel staging — a low impulse primary flame is developed in the port neck; a secondary flame covers the root of the primary flame reducing its core temperature
1.20.3. Sulphur oxides (SOX) Technique Description Treatment of refinery fuel gas (RFG) Some refinery fuel gases may be sulphur-free at source (e.g. from catalytic reforming and isomerisation processes) but most other processes produce sulphur-containing gases (e.g. off-gases from the visbreaker, hydrotreater or catalytic cracking units). These gas streams require an appropriate treatment for gas desulphurisation (e.g. by acid gas removal — see below — to remove H2S) before being released to the refinery fuel gas system Refinery fuel oil (RFO) desulphurisation by hydrotreatment In addition to selection of low-sulphur crude, fuel desulphurisation is achieved by the hydrotreatment process (see below) where hydrogenation reactions take place and lead to a reduction in sulphur content Use of gas to replace liquid fuel Decrease the use of liquid refinery fuel (generally heavy fuel oil containing sulphur, nitrogen, metals, etc.) by replacing it with on-site Liquefied Petroleum Gas (LPG) or refinery fuel gas (RFG) or by externally supplied gaseous fuel (e.g. natural gas) with a low level of sulphur and other undesirable substances. At the individual combustion unit level, under multi-fuel firing, a minimum level of liquid firing is necessary to ensure flame stability Use of SOX reducing catalysts additives Use of a substance (e.g. metallic oxides catalyst) that transfers the sulphur associated with coke from the regenerator back to the reactor. It operates most efficiently in full combustion mode rather than in deep partial-combustion mode. NB: SOX reducing catalysts additives might have a detrimental effect on dust emissions by increasing catalyst losses due to attrition, and on NOX emissions by participating in CO promotion, together with the oxidation of SO2 to SO3 Hydrotreatment Based on hydrogenation reactions, hydrotreatment aims mainly at producing low-sulphur fuels (e.g. 10 ppm gasoline and diesel) and optimising the process configuration (heavy residue conversion and middle distillate production). It reduces the sulphur, nitrogen and metal content of the feed. As hydrogen is required, sufficient production capacity is needed. As the technique transfer sulphur from the feed to hydrogen sulphide (H2S) in the process gas, treatment capacity (e.g. amine and Claus units) is also a possible bottleneck Acid gas removal e.g. by amine treating Separation of acid gas (mainly hydrogen sulphide) from the fuel gases by dissolving it in a chemical solvent (absorption). The commonly used solvents are amines. This is generally the first step treatment needed before elemental sulphur can be recovered in the SRU Sulphur recovery unit (SRU) Specific unit that generally consists of a Claus process for sulphur removal of hydrogen sulphide (H2S)-rich gas streams from amine treating units and sour water strippers. SRU is generally followed by a tail gas treatment unit (TGTU) for remaining H2S removal Tail gas treatment unit (TGTU) A family of techniques, additional to the SRU in order to enhance the removal of sulphur compounds. They can be divided into four categories according to the principles applied: Wet scrubbing In the wet scrubbing process, gaseous compounds are dissolved in a suitable liquid (water or alkaline solution). Simultaneous removal of solid and gaseous compounds may be achieved. Downstream of the wet scrubber, the flue-gases are saturated with water and a separation of the droplets is required before discharging the flue-gases. The resulting liquid has to be treated by a waste water process and the insoluble matter is collected by sedimentation or filtration According to the type of scrubbing solution, it can be: According to the contact method, the various techniques may require e.g.: Where scrubbers are mainly intended for SOX removal, a suitable design is needed to also efficiently remove dust. The typical indicative SOx removal efficiency is in the range 85-98 %. Non-regenerative scrubbing Sodium or magnesium-based solution is used as alkaline reagent to absorb SOX generally as sulphates. Techniques are based on e.g.: Seawater scrubbing A specific type of non-regenerative scrubbing using the alkalinity of the seawater as solvent. Generally requires an upstream abatement of dust Regenerative scrubbing Use of specific SOX absorbing reagent (e.g. absorbing solution) that generally enables the recovery of sulphur as a by-product during a regenerating cycle where the reagent is reused
direct oxidation to sulphur
continuation of the Claus reaction (sub-dewpoint conditions)
oxidation to SO2 and recovering sulphur from SO2
reduction to H2S and recovery of sulphur from this H2S (e.g. amine process)
a non-regenerative technique (e.g. sodium or magnesium-based)
a regenerative technique (e.g. amine or soda solution)
Venturi using the energy from inlet gas by spraying it with the liquid
packed towers, plate towers, spray chambers.
wet limestone
aqueous ammonia
seawater (see infra)
1.20.4. Combined techniques (SOx, NOx and dust) Technique Description Wet scrubbing See Section 1.20.3 SNOX combined technique Combined technique to remove SOX, NOX and dust where a first dust removal stage (ESP) takes place followed by some specific catalytic processes. The sulphur compounds are recovered as commercial-grade concentrated sulphuric acid, while NOX is reduced to N2. Overall SOX removal is in the range: 94-96,6 %. Overall NOX removal is in the range: 87-90 %
1.20.5. Carbon monoxide (CO) Technique Description Combustion operation control The increase in CO emissions due to the application of combustion modifications (primary techniques) for the reduction of NOX emissions can be limited by a careful control of the operational parameters Catalysts with carbon monoxide (CO) oxidation promoters Use of a substance which selectively promotes the oxidation of CO into CO2 (combustion) Carbon monoxide (CO) boiler Specific post-combustion device where CO present in the flue-gas is consumed downstream of the catalyst regenerator to recover the energy It is usually used only with partial-combustion FCC units
1.20.6.NB Volatile organic compounds (VOC) Vapour recovery Volatile organic compounds emissions from loading and unloading operations of most volatile products, especially crude oil and lighter products, can be abated by various techniques e.g.: — Absorption the vapour molecules dissolve in a suitable absorption liquid (e.g. glycols or mineral oil fractions such as kerosene or reformate). The loaded scrubbing solution is desorbed by reheating in a further step. The desorbed gases must either be condensed, further processed, and incinerated or re-absorbed in an appropriate stream (e.g. of the product being recovered) — Adsorption the vapour molecules are retained by activate sites on the surface of adsorbent solid materials, e.g. activated carbon (AC) or zeolite. The adsorbent is periodically regenerated. The resulting desorbate is then absorbed in a circulating stream of the product being recovered in a downstream wash column. Residual gas from wash column is sent to further treatment — Membrane gas separation the vapour molecules are processed through selective membranes to separate the vapour/air mixture into a hydrocarbon-enriched phase (permeate), which is subsequently condensed or absorbed, and a hydrocarbon-depleted phase (retentate). — Two-stage refrigeration/condensation by cooling of the vapour/gas mixture the vapour molecules condense and are separated as a liquid. As the humidity leads to the icing-up of the heat exchanger, a two-stage condensation process providing for alternate operation is required. — Hybrid systems combinations of available techniques Absorption and adsorption processes cannot notably reduce methane emissions. Vapour destruction Destruction of VOCs can be achieved through e.g. thermal oxidation (incineration) or catalytic oxidation when recovery is not easily feasible. Safety requirements (e.g. flame arrestors) are needed to prevent explosion. Thermal oxidation occurs typically in single chamber, refractory-lined oxidisers equipped with gas burner and a stack. If gasoline is present, heat exchanger efficiency is limited and preheat temperatures are maintained below 180 °C to reduce ignition risk. Operating temperatures range from 760 °C to 870 °C and residence times are typically 1 second. When a specific incinerator is not available for this purpose, an existing furnace may be used to provide the required temperature and residence times. Catalytic oxidation requires a catalyst to accelerate the rate of oxidation by adsorbing the oxygen and the VOCs on its surface The catalyst enables the oxidation reaction to occur at lower temperature than required by thermal oxidation: typically ranging from 320 °C to 540 °C. A first preheating step (electrically or with gas) takes place to reach a temperature necessary to initiate the VOCs catalytic oxidation. An oxidation step occurs when the air is passed through a bed of solid catalysts LDAR (leak detection and repair) programme An LDAR (leak detection and repair) programme is a structured approach to reduce fugitive VOC emissions by detection and subsequent repair or replacement of leaking components. Currently, sniffing (described by EN 15446) and optical gas imaging methods are available for the identification of the leaks. Sniffing method The first step is the detection using hand-held VOC analysers measuring the concentration adjacent to the equipment (e.g. by using flame ionisation or photo-ionisation). The second step consists of bagging the component to carry out a direct measurement at the source of emission. This second step is sometimes replaced by mathematical correlation curves derived from statistical results obtained from a large number of previous measurements made on similar components. Optical gas imaging methods Optical imaging uses small lightweight hand-held cameras which enable the visualisation of gas leaks in real time, so that they appear as 'smoke' on a video recorder together with the normal image of the component concerned to easily and rapidly locate significant VOC leaks. Active systems produce an image with a back-scattered infrared laser light reflected on the component and its surroundings. Passive systems are based on the natural infrared radiation of the equipment and its surroundings VOC diffuse emissions monitoring Full screening and quantification of site emissions can be undertaken with an appropriate combination of complementary methods, e.g. Solar occultation flux (SOF) or differential absorption lidar (DIAL) campaigns. These results can be used for trend evaluation in time, cross checking and updating/validation of the ongoing LDAR programme. Solar occultation flux (SOF) The technique is based on the recording and spectrometric Fourier Transform analysis of a broadband infrared or ultraviolet/visible sunlight spectrum along a given geographical itinerary, crossing the wind direction and cutting through VOC plumes. Differential absorption LIDAR (DIAL) DIAL is a laser-based technique using differential adsorption LIDAR (light detection and ranging) which is the optical analogue of sonic radio wave-based RADAR. The technique relies on the back-scattering of laser beam pulses by atmospheric aerosols, and the analysis of spectral properties of the returned light collected with a telescope High-integrity equipment High-integrity equipment includes e.g.:
valves with double packing seals
magnetically driven pumps/compressors/agitators
pumps/compressors/agitators fitted with mechanical seals instead of packing
high-integrity gaskets (such as spiral wound, ring joints) for critical applications
1.20.7. Other techniques Techniques to prevent or reduce emissions from flaring Correct plant design includes sufficient flare gas recovery system capacity, the use of high-integrity relief valves and other measures to use flaring only as a safety system for other than normal operations (start-up, shutdown, emergency). Plant management includes organisational and control measures to reduce flaring events by balancing RFG system, using advanced process control, etc. Flaring devices design includes height, pressure, assistance by steam, air or gas, type of flare tips, etc. It aims at enabling smokeless and reliable operations and ensuring an efficient combustion of excess gases when flaring from non-routine operations. Monitoring and reporting Continuous monitoring (measurements of gas flow and estimations of other parameters) of gas sent to flaring and associated parameters of combustion (e.g. flow gas mixture and heat content, ratio of assistance, velocity, purge gas flow rate, pollutant emissions). Reporting of flaring events makes it possible to use flaring ratio as a requirement included in the EMS and to prevent future events. Visual remote monitoring of the flare can also be carried out by using colour TV monitors during flare events Choice of the catalyst promoter to avoid dioxins formation During the regeneration of the reformer catalyst, organic chloride is generally needed for effective reforming catalyst performance (to re-establish the proper chloride balance in the catalyst and to assure the correct dispersion of the metals). The choice of the appropriate chlorinated compound will have an influence on the possibility of emissions of dioxins and furans Solvent recovery for base oil production processes The solvent recovery unit consists of a distillation step where the solvents are recovered from the oil stream and a stripping step (with steam or an inert gas) in a fractionator. The solvents used may be a mixture (DiMe) of 1,2-dichloroethane (DCE) and dichloromethane (DCM). In wax-processing units, solvent recovery (e.g. for DCE) is carried out using two systems: one for the deoiled wax and another one for the soft wax. Both consist of heat-integrated flashdrums and a vacuum stripper. Streams from the dewaxed oil and waxes product are stripped for removal of traces of solvents
1.21. Description of techniques for the prevention and control of emissions to water
1.21.
1.21.1. Waste water pretreatment Pretreatment of sour water streams before reuse or treatment Send generated sour water (e.g. from distillation, cracking, coking units) to appropriate pretreatment (e.g. stripper unit) Pretreatment of other waste water streams prior to treatment To maintain treatment performance, appropriate pretreatment may be required
1.21.2. Waste water treatment Removal of insoluble substances by recovering oil. These techniques generally include: Removal of insoluble substances by recovering suspended solid and dispersed oil These techniques generally include: Removal of soluble substances including biological treatment and clarification Biological treatment techniques may include: One of the most commonly used suspended bed system in refineries WWTP is the activated sludge process. Fixed bed systems may include a biofilter or trickling filter Additional treatment step A specific waste water treatment intended to complement the previous treatment steps e.g. for further reducing nitrogen or carbon compounds. Generally used where specific local requirements for water preservation exist.
API Separators (APIs)
Corrugated Plate Interceptors (CPIs)
Parallel Plate Interceptors (PPIs)
Tilted Plate Interceptors (TPIs)
Buffer and/or equalisation tanks
Dissolved Gas Flotation (DGF)
Induced Gas Flotation (IGF)
Sand Filtration
Fixed bed systems
Suspended bed systems.
Versions
Cited by
- Commission Implementing Decision of 30 October 2014 establishing the type, format and frequency of information to be made available by the Member States on integrated emission management techniques applied in mineral oil and gas refineries, pursuant to Directive 2010/75/EU of the European Parliament and of the Council (notified under document C(2014) 7517) (Text with EEA relevance) (2014/768/EU) Decision · Grade B
Commission Implementing Decision 2014/738/EU establishes conclusions on best available techniques (BAT conclusions) for the refining of mineral oil and gas. BAT conclusions 57 and 58 established by that Decision enable Member States to make use of an integrated emission management technique for emissions of nitrogen oxides (NOx) and sulphur dioxide (SO2) from certain technical units.
- Commission Implementing Decision of 30 October 2014 establishing the type, format and frequency of information to be made available by the Member States on integrated emission management techniques applied in mineral oil and gas refineries, pursuant to Directive 2010/75/EU of the European Parliament and of the Council (notified under document C(2014) 7517) (Text with EEA relevance) (2014/768/EU) Decision · Grade B
Member States shall make available to the Commission the information on the implementation of the integrated emission management techniques set out in BAT 57 and BAT 58 adopted by Implementing Decision 2014/738/EU. The information referred to in the first subparagraph shall be made available in accordance with the Annex and shall cover the years 2017, 2018 and 2019. That information shall be made available for each of the mineral oil and gas refineries where an integrated emission management technique set out in BAT 57 or BAT 58 is implemented for emissions to air of nitrogen oxides (NOx) or s
- Commission Implementing Decision of 30 October 2014 establishing the type, format and frequency of information to be made available by the Member States on integrated emission management techniques applied in mineral oil and gas refineries, pursuant to Directive 2010/75/EU of the European Parliament and of the Council (notified under document C(2014) 7517) (Text with EEA relevance) (2014/768/EU) Decision · Grade B
how these limit values were determined in relation to BAT 57 and BAT 58 set out in the BAT conclusions under Implementing Decision 2014/738/EU;