Commission Implementing Decision (EU) 2022/2427 of 6 December 2022 establishing the best available techniques (BAT) conclusions, under Directive 2010/75/EU of the European Parliament and of the Council on industrial emissions, for common waste gas management and treatment systems in the chemical sector (notified under document C(2022) 8788) (Text with EEA relevance)
Grade B
mapped from publisher markup. A grade says how a document's structure was obtained, not how reliable the law is.
Address https://gelex.eu/eli/EU/decision/2022/2427@2022-12-06/en
Contents
- Preamble
- ANNEX
- ANNEX
- 1. SCOPE
- Best Available Techniques
- Emission levels associated with the best available techniques (BAT-AELs) and indicative emission levels for channelled emissions to air
- BAT-AELs for diffuse VOC emissions to air
- BAT-AELs for total emissions to air for the production of polymers or synthetic rubbers Production of polyolefins or synthetic rubbers
- 1.1.
- 1.1.1.
- BAT 1. i.
- BAT 2. i.
- a.
- b.
- c.
- d.
- e.
- f.
- g.
- h.
- 1.1.2.
- BAT 3. i.
- 1.1.3.
- 1.1.3.1.
- BAT 4. Description
- BAT 5. Description
- 1.1.3.2.
- 1.1.3.3.
- BAT 9. Applicability
- BAT 10. Description
- BAT 11. Table 1.1 BAT-associated emission levels (BAT-AELs) for channelled emissions to air of organic compounds
- BAT 12. Table 1.2 BAT-associated emission level (BAT-AEL) for channelled emissions to air of PCDD/F from thermal treatment of waste gases containing chlorine and/or chlorinated compounds
- 1.1.3.4.
- BAT 13. Applicability
- BAT 14. Table 1.3 BAT-associated emission levels (BAT-AELs) for channelled emissions to air of dust, lead and nickel
- 1.1.3.5.
- BAT 15. Description
- BAT 16. Table 1.4 BAT-associated emission levels (BAT-AELs) for channelled emissions to air of NOX and indicative emission level for channelled emissions to air of CO from thermal treatment
- BAT 17. Table 1.5 BAT-associated emission level (BAT-AEL) for channelled emissions to air of ammonia from the use of SCR or SNCR (ammonia slip)
- BAT 18. Table 1.6 BAT-associated emission levels (BAT-AELs) for channelled emissions to air of inorganic compounds
- 1.1.4.
- 1.1.4.1.
- BAT 19. i.
- a.
- b.
- c.
- d.
- e.
- 1.1.4.2.
- BAT 20. Note
- BAT 21. Applicability
- BAT 22. Note
- 1.1.4.3.
- BAT 23.
- 1.1.4.4. Table 1.7 BAT-associated emission level (BAT-AEL) for diffuse VOC emissions to air from the use of solvents or the reuse of recovered solvents
- 1.2.
- 1.2.1.
- BAT 24. Note
- BAT 25. Table 1.8 BAT-associated emission levels (BAT-AELs) for total emissions to air of VOCs from the production of polyolefins expressed as specific emission loads
- 1.2.2.
- BAT 27. Note
- BAT 28. Applicability
- BAT 29. Table 1.9 BAT-associated emission level (BAT-AEL) for channelled emissions to air of VCM from the recovery of VCM
- BAT 30. Table 1.10 Table 1.11 BAT-associated emission levels (BAT-AELs) for total emissions to air of VCM from the production of PVC expressed as specific emission loads BAT-associated emission levels (BAT-AELs) for the VCM concentration in the PVC slurry/latex
- 1.2.3.
- BAT 31. Note
- BAT 32. Table 1.12 BAT-associated emission level (BAT-AEL) for total emissions to air of VOC from the production of synthetic rubbers expressed as specific emission load
- 1.2.4.
- BAT 35. Table 1.13 Table 1.14 BAT-associated emission levels (BAT-AELs) for channelled emissions to air of CS2 and H2S from the production of viscose using CS2 BAT-associated emission levels (BAT-AELs) for emissions to air of H2S and CS2 from the production of staple fibres and casing expressed as specific emission loads
- 1.3.
- BAT 36. Table 1.15 BAT-associated emission level (BAT-AEL) for channelled NOX emissions to air and indicative emission level for channelled CO emissions to air from process furnaces/heaters
- 1.4.
THE EUROPEAN COMMISSION,
Having regard to the Treaty on the Functioning of the European Union,
Having regard to Directive 2010/75/EU of the European Parliament and of the Council of 24 November 2010 on industrial emissions (integrated pollution prevention and control), and in particular Article 13(5) thereof,
Whereas:
(1) Best available techniques (BAT) conclusions are the reference for setting permit conditions for installations covered by Chapter II of Directive 2010/75/EU and competent authorities should set emission limit values which ensure that, under normal operating conditions, emissions do not exceed the emission levels associated with the best available techniques as laid down in the BAT conclusions.
(2) In accordance with Article 13(4) of Directive 2010/75/EU, the forum composed of representatives of Member States, the industries concerned and non-governmental organisations promoting environmental protection, established by Commission Decision of 16 May 2011, provided the Commission on 11 May 2022 with its opinion on the proposed content of the BAT reference document for common waste gas management and treatment systems in the chemical sector. That opinion is publicly available.
(3) The BAT conclusions set out in the Annex to this Decision take into account the opinion of the forum on the proposed content of the BAT reference document. They contain the key elements of the BAT reference document.
(4) The measures provided for in this Decision are in accordance with the opinion of the Committee established by Article 75(1) of Directive 2010/75/EU,
HAS ADOPTED THIS DECISION:
Article 1
The best available techniques (BAT) conclusions for the common waste gas management and treatment systems in the chemical sector, as set out in the Annex, are adopted.
Article 2
This Decision is addressed to the Member States.
Done at Brussels, 6 December 2022. For the Commission Virginijus Sinkevičius Member of the Commission
ANNEX
(1) Emissions to air from the production of chlorine, hydrogen, and sodium/potassium hydroxide by the electrolysis of brine. This is covered by the BAT conclusions for the Production of Chlor-alkali (CAK). (1) lower olefins using the steam cracking process; (2) formaldehyde; (3) ethylene oxide and ethylene glycols; (4) phenol from cumene; (5) dinitrotoluene from toluene, toluene diamine from dinitrotoluene, toluene diisocyanate from toluene diamine, methylene diphenyl diamine from aniline, methylene diphenyl diisocyanate from methylene diphenyl diamine; (6) ethylene dichloride (EDC) and vinyl chloride monomer (VCM); (7) hydrogen peroxide. (2) Channelled emissions to air from the production of the following chemicals in continuous processes where the total production capacity of those chemicals exceeds 20 kt/yr: This is covered by the BAT conclusions for the Production of Large Volume Organic Chemicals (LVOC). However, channelled emissions to air of nitrogen oxides (NOX) and carbon monoxide (CO) from thermal treatment of waste gases originating from the aforementioned production processes are included in the scope of these BAT conclusions. (1) ammonia; (2) ammonium nitrate; (3) calcium ammonium nitrate; (4) calcium carbide; (5) calcium chloride; (6) calcium nitrate; (7) carbon black; (8) ferrous chloride; (9) ferrous sulphate (i.e. copperas and related products, such as chloro-sulphates); (10) hydrofluoric acid; (11) inorganic phosphates; (12) nitric acid; (13) nitrogen-, phosphorus- or potassium-based fertilisers (simple or compound fertilisers); (14) phosphoric acid; (15) precipitated calcium carbonate; (16) sodium carbonate (i.e. soda ash); (17) sodium chlorate; (18) sodium silicate; (19) sulphuric acid; (20) synthetic amorphous silica; (21) titanium dioxide and related products; (22) urea; (23) urea-ammonium nitrate. (3) Emissions to air from the production of the following inorganic chemicals: This may be covered by the BAT conclusions for the Production of Large Volume Inorganic Chemicals (LVIC). (4) Emissions to air from steam reforming as well as from the physical purification and reconcentration of spent sulphuric acid, provided that these processes are directly associated with a production process listed under the aforementioned points 2 or 3. (5) Emissions to air from the production of magnesium oxide using the dry process route. This may be covered by the BAT conclusions for the Production of Cement, Lime and Magnesium Oxide (CLM). (1) Combustion units other than process furnaces/heaters. This may be covered by the BAT conclusions for Large Combustion Plants (LCP), the BAT conclusions for the Refining of Mineral Oil and Gas (REF) and/or by Directive (EU) 2015/2193 of the European Parliament and of the Council. (2) Process furnaces/heaters with a total rated thermal input below 1 MW. (3) Process furnaces/heaters used in lower olefins, ethylene dichloride and/or vinyl chloride monomer production referred to in point 2 above. This is covered by the BAT conclusions for the production of Large Volume Organic Chemicals (LVOC). (6) Emissions to air from the following: (7) Emissions to air from waste incineration plants. This may be covered by the BAT conclusions for Waste Incineration (WI). (8) Emissions to air from the storage, transfer and handling of liquids, liquefied gases and solids, where these are not directly associated with the activity specified in Annex I to Directive 2010/75/EU: 4. Chemical industry. This may be covered by the BAT conclusions for Emissions from Storage (EFS). However, emissions to air from the storage, transfer and handling of liquids, liquefied gases and solids are included in the scope of these BAT conclusions provided that these processes are directly associated with the chemical production process specified in the scope of these BAT conclusions. (9) Emissions to air from indirect cooling systems. This may be covered by the BAT conclusions for Industrial Cooling Systems (ICS). (10) Production of Chlor-alkali (CAK); (11) Manufacture of Large Volume Inorganic Chemicals – Ammonia, Acids and Fertilisers (LVIC-AAF); (12) Manufacture of Large Volume Inorganic Chemicals – Solids and Others Industry (LVIC-S); (13) Production of Large Volume Organic Chemicals (LVOC); (14) Manufacture of Organic Fine Chemicals (OFC); (15) Production of Polymers (POL); (16) Production of Speciality Inorganic Chemicals (SIC); (17) Refining of Mineral Oil and Gas (REF); (18) Economics and Cross-media Effects (ECM); (19) Emissions from Storage (EFS); (20) Energy Efficiency (ENE); (21) Industrial Cooling Systems (ICS); (22) Large Combustion Plants (LCP); (23) Monitoring of Emissions to Air and Water from IED installations (ROM); (24) Waste Incineration (WI); (25) Waste Treatment (WT). Grp. scope. These BAT conclusions concern the following activity specified in Annex I to Directive 2010/75/EU: 4. Chemical industry (i.e. all production processes included in the categories of activities listed in points 4.1 to 4.6 of Annex I, unless specified otherwise). More specifically, these BAT conclusions focus on emissions to air from the aforementioned activity. These BAT conclusions do not address the following: Other BAT conclusions which are complementary for the activities covered by these BAT conclusions include Common Waste Water and Waste Gas Treatment/Management Systems in the Chemical Sector (CWW). Other BAT conclusions and reference documents which could be relevant for the activities covered by these BAT conclusions are the following: These BAT conclusions apply without prejudice to other relevant legislation, e.g. on the registration, evaluation, authorisation and restriction of chemicals (REACH) or on classification, labelling and packaging of substances and mixtures (CLP). (1) moving equipment, such as agitators, compressors, pumps, valves (manual and automatic); (2) static equipment, such as flanges and other connections, open-ended lines, sampling points. (3) substances used (e.g. substances that cannot be substituted, very corrosive substances); (4) operating conditions (e.g. very high temperature or pressure); (5) the functioning of the plant; (6) resource availability (e.g. availability of spare parts when replacing a piece of equipment, availability of qualified manpower); (7) expected environmental benefits (e.g. giving priority to maintenance, repair or replacement actions with the highest environmental benefit). (8) combustion units used for the treatment of objects or feed material through direct contact, e.g. in drying processes or chemical reactors; or (9) combustion units whose radiant and/or conductive heat is transferred to objects or feed material through a solid wall without using an intermediary heat transfer fluid, e.g. furnaces or reactors heating a process stream used in the (petro-)chemical industry. Grp. definitions. For the purposes of these BAT conclusions, the following definitions apply: General terms Term used Definition Channelled emissions to air Emissions of pollutants to air through an emission point such as a stack. Combustion unit Any technical apparatus in which fuels are oxidised in order to use the heat thus generated. Combustion units include boilers, engines, turbines and process furnaces/heaters, but do not include thermal or catalytic oxidisers. Complex inorganic pigments A stable crystal lattice of different metal cations. The most important host-lattices are rutile, spinel, zircon, and haematite/corundum, but other stable structures exist. Continuous measurement Measurement using an automated measuring system permanently installed on site. Continuous process A process in which the raw materials are fed continuously into the reactor with the reaction products then fed into connected downstream separation and/or recovery units. Diffuse emissions Non-channelled emissions to air. Diffuse emissions include fugitive and non-fugitive emissions. Emissions to air Generic term for emissions of pollutants to air including both channelled and diffuse emissions. Ethanolamines Collective term for monoethanolamine, diethanolamine and triethanolamine, or mixtures thereof. Ethylene glycols Collective term for monoethylene glycol, diethylene glycol and triethylene glycol, or mixtures thereof. Existing plant A plant that is not a new plant. Existing process furnace/heater A process furnace/heater that is not a new process furnace/heater. Flue-gas The exhaust gas exiting a combustion unit. Fugitive emissions Non-channelled emissions to air caused by loss of tightness of equipment which is designed or assembled to be tight. Fugitive emissions can arise from: Lower olefins Collective term for ethylene, propylene, butylene and butadiene, or mixtures thereof. Major plant upgrade A major change in the design or technology of a plant with major adjustments or replacements of the process and/or abatement units and associated equipment. Mass flow The mass of a given substance or parameter which is emitted over a defined period of time. New plant A plant first permitted on the site of the installation following the publication of these BAT conclusions or a complete replacement of a plant following the publication of these BAT conclusions. New process furnace/heater A process furnace/heater in a plant first permitted following the publication of these BAT conclusions or a complete replacement of a process furnace/heater following the publication of these BAT conclusions. Non-fugitive emissions Diffuse emissions other than fugitive emissions. Non-fugitive emissions may arise from, for example, atmospheric vents, bulk storage, loading/unloading systems, vessels and tanks (on opening), open gutters, sampling systems, tank venting, waste, sewers and water treatment plants. NOX precursors Nitrogen-containing compounds (e.g. acrylonitrile, ammonia, nitrous gases, nitrogen-containing organic compounds) in the input to thermal or catalytic oxidation that lead to NOX emissions. Elemental nitrogen is not included. Operational constraint Limitation or restriction connected, for example, to: Periodic measurement Measurement at specified time intervals using manual or automated methods. Polymer grade For each type of polymer, there are different product qualities (i.e. grades) which vary in structure and molecular mass, and are optimised for specific applications. In the case of polyolefins, these may vary regarding the use of co-polymers such as EVA. In the case of PVC, they may vary in the average length of the polymer chain and in the porosity of the particles. Process furnace/heater Process furnaces or heaters are: As a consequence of the application of good energy recovery practices, some of the process furnaces/heaters may have an associated steam/electricity generation system. This is an integral design feature of the process furnace/heater that cannot be considered in isolation. Process off-gas The gas leaving a process which is further treated for recovery and/or abatement. Solvent Organic solvent as defined in Article 3(46) of Directive 2010/75/EU. Solvent consumption Consumption of solvent as defined in Article 57(9) of Directive 2010/75/EU. Solvent input The total quantity of organic solvents used as defined in Part 7 of Annex VII to Directive 2010/75/EU. Solvent mass balance A mass balance exercise conducted at least on an annual basis according to Part 7 of Annex VII to Directive 2010/75/EU. Thermal treatment Treatment of waste gases using thermal or catalytic oxidation. Total emissions The sum of channelled and diffuse emissions. Valid hourly (or half-hourly) average An hourly (or half-hourly) average is considered valid when there is no maintenance or malfunction of the automated measuring system. Substances/Parameters Term used Definition Cl2 Elemental chlorine. CO Carbon monoxide. CS2 Carbon disulphide. Dust Total particulate matter (in air). Unless specified otherwise, dust includes PM2,5 and PM10. EDC Ethylene dichloride (1,2-Dichloroethane). HCl Hydrogen chloride. HCN Hydrogen cyanide. HF Hydrogen fluoride. H2S Hydrogen sulphide. NH3 Ammonia. Ni Nickel. N2O Dinitrogen oxide (also referred to as nitrous oxide). NOX The sum of nitrogen monoxide (NO) and nitrogen dioxide (NO2), expressed as NO2. Pb Lead. PCDD/F Polychlorinated dibenzo-p-dioxins and -furans. PM2,5 Particulate matter which passes through a size-selective inlet with a 50 % efficiency cut-off at 2,5 μm aerodynamic diameter as defined in Directive 2008/50/EC of the European Parliament and of the Council. PM10 Particulate matter which passes through a size-selective inlet with a 50 % efficiency cut-off at 10 μm aerodynamic diameter as defined in Directive 2008/50/EC. SO2 Sulphur dioxide. SOX The sum of sulphur dioxide (SO2), sulphur trioxide (SO3), and sulphuric acid aerosols, expressed as SO2. TVOC Total volatile organic carbon, expressed as C. VCM Vinyl chloride monomer. VOC Volatile organic compound as defined in Article 3(45) of Directive 2010/75/EU. Grp. acronyms. For the purposes of these BAT conclusions, the following acronyms apply: Acronym Definition CLP Regulation (EC) No 1272/2008 of the European Parliament and of the Council on classification, labelling and packaging of substances and mixtures. CMR Carcinogenic, mutagenic or toxic for reproduction. CMR 1A CMR substance of category 1A as defined in Regulation (EC) No 1272/2008 as amended, i.e. carrying the hazard statements H340, H350, H360. CMR 1B CMR substance of category 1B as defined in Regulation (EC) No 1272/2008 as amended, i.e. carrying the hazard statements H340, H350, H360. CMR 2 CMR substance of category 2 as defined in Regulation (EC) No 1272/2008 as amended, i.e. carrying the hazard statements H341, H351, H361. DIAL Differential absorption LIDAR. EMS Environmental Management System. EPS Expandable polystyrene. E-PVC PVC produced by emulsion polymerisation. EVA Ethylene-vinyl acetate. GPPS General-purpose polystyrene. HDPE High-density polyethylene. HEAF High-efficiency air filter. HEPA High-efficiency particle air. HIPS High-impact polystyrene. IED Directive 2010/75/EU on industrial emissions. I-TEQ International toxic equivalent – derived by using the equivalence factors in Part 2 of Annex VI to Directive 2010/75/EU. LDAR Leak detection and repair. LDPE Low-density polyethylene. LIDAR Light detection and ranging. LLDPE Linear low-density polyethylene. OGI Optical gas imaging. OTNOC Other than normal operating conditions. PP Polypropylene. PVC Polyvinyl chloride. REACH Regulation (EC) No 1907/2006 of the European Parliament and of the Council concerning the registration, evaluation, authorisation and restriction of chemicals. SCR Selective catalytic reduction. SNCR Selective non-catalytic reduction. SOF Solar occultation flux. S-PVC PVC produced by suspension polymerisation. ULPA Ultra-low penetration air. Grp_available. techniques. The techniques listed and described in these BAT conclusions are neither prescriptive nor exhaustive. Other techniques may be used that ensure at least an equivalent level of environmental protection. Unless otherwise stated, the BAT conclusions are generally applicable. Grp_levels_associated_with_the_best_available_techniques_bataels_and_indicative_emission_levels_for_channelled_emissions_to. air. The BAT-AELs and the indicative emission levels for channelled emissions to air given in these BAT conclusions refer to values of concentration, expressed as mass of emitted substance per volume of waste gas under standard conditions (dry gas at a temperature of 273,15 K, and a pressure of 101,3 kPa) and expressed in the unit mg/Nm3, μg/Nm3 or ng I-TEQ/Nm3. The reference oxygen levels used to express BAT-AELs and indicative emission levels in these BAT conclusions are shown in the table below. Source of emissions Reference oxygen level (OR) Process furnace/heater using indirect heating 3 dry vol-% All other sources No correction for the oxygen level For the cases where a reference oxygen level is given, the equation for calculating the emission concentration at the reference oxygen level is: ER21OR21OMEM where: ER emission concentration at the reference oxygen level OR; OR reference oxygen level in vol-%; EM measured emission concentration; OM measured oxygen level in vol-%. The equation above does not apply if the process furnace(s)/heater(s) use(s) oxygen-enriched air or pure oxygen or when additional air intake for safety reasons brings the oxygen level in the waste gas very close to 21 vol-%. In this case, the emission concentration at the reference oxygen level of 3 dry vol-% is calculated differently. For averaging periods of BAT-AELs and indicative emission levels for channelled emissions to air, the following definitions apply. Type of measurement Averaging period Definition Continuous Daily average Average over a period of 1 day based on valid hourly or half-hourly averages. Periodic Average over the sampling period Average value of three consecutive samplings/measurements of at least 30 minutes each. For the purpose of calculating the mass flows in relation to BAT 11 (Table 1.1), BAT 14 (Table 1.3), BAT 18 (Table 1.6), BAT 29 (Table 1.9) and BAT 36 (Table 1.15), where waste gases with similar characteristics, e.g. containing the same (type of) substances/parameters, and discharged through two or more separate stacks could, in the judgement of the competent authority, be discharged through a common stack, these stacks shall be considered as a single stack. Grp_for_diffuse_voc_emissions_to. air. For diffuse VOC emissions from the use of solvents or the reuse of recovered solvents, the BAT-AELs in these BAT conclusions are given as a percentage of the solvent input, calculated on an annual basis according to Part 7 of Annex VII to Directive 2010/75/EU. Grp_of_polyolefins_or_synthetic. rubbers. For total emissions to air of VOCs from the production of polyolefins or synthetic rubbers, the BAT-AELs in these BAT conclusions are given as specific emission loads calculated on an annual basis by dividing the total VOC emissions by a sector-dependent production rate, expressed in the unit g C/kg of product. Grp_of. pvc. For total emissions to air of VCM from the production of PVC, the BAT-AELs in these BAT conclusions are given as specific emission loads calculated on an annual basis by dividing the total VCM emissions by a sector-dependent production rate, expressed in the unit g/kg of product. For the purpose of calculating specific emission loads, total emissions include the VCM concentration in the PVC. Grp_of. viscose. For the production of viscose, the BAT-AEL in these BAT conclusions is given as a specific emission load calculated on an annual basis by dividing the total S emissions by the production rate of staple fibres or casing, expressed in the unit g S/kg of product. (i) commitment, leadership, and accountability of the management, including senior management, for the implementation of an effective EMS; (ii) an analysis that includes the determination of the organisation’s context, the identification of the needs and expectations of interested parties, the identification of characteristics of the installation that are associated with possible risks for the environment (or human health) as well as of the applicable legal requirements relating to the environment; (iii) development of an environmental policy that includes the continuous improvement of the environmental performance of the installation; (iv) establishing objectives and performance indicators in relation to significant environmental aspects, including safeguarding compliance with applicable legal requirements; (v) planning and implementing the necessary procedures and actions (including corrective and preventive actions where needed), to achieve the environmental objectives and avoid environmental risks; (vi) determination of structures, roles and responsibilities in relation to environmental aspects and objectives and provision of the financial and human resources needed; (vii) ensuring the necessary competence and awareness of staff whose work may affect the environmental performance of the installation (e.g. by providing information and training); (viii) internal and external communication; (ix) fostering employee involvement in good environmental management practices; (x) establishing and maintaining a management manual and written procedures to control activities with significant environmental impact as well as relevant records; (xi) effective operational planning and process control; (xii) implementation of appropriate maintenance programmes; (xiii) emergency preparedness and response protocols, including the prevention and/or mitigation of the adverse (environmental) impacts of emergency situations; (xiv) when (re)designing a (new) installation or a part thereof, consideration of its environmental impacts throughout its life, which includes construction, maintenance, operation and decommissioning; (xv) implementation of a monitoring and measurement programme; if necessary, information can be found in the Reference Report on Monitoring of Emissions to Air and Water from IED Installations; (xvi) application of sectoral benchmarking on a regular basis; (xvii) periodic independent (as far as practicable) internal auditing and periodic independent external auditing in order to assess the environmental performance and to determine whether or not the EMS conforms to planned arrangements and has been properly implemented and maintained; (xviii) evaluation of causes of nonconformities, implementation of corrective actions in response to nonconformities, review of the effectiveness of corrective actions, and determination of whether similar nonconformities exist or could potentially occur; (xix) periodic review, by senior management, of the EMS and its continuing suitability, adequacy and effectiveness; (xx) following and taking into account the development of cleaner techniques. (xxi) an inventory of channelled and diffuse emissions to air (see BAT 2); (xxii) an OTNOC management plan for emissions to air (see BAT 3); (xxiii) an integrated waste gas management and treatment strategy for channelled emissions to air (see BAT 4); (xxiv) a management system for diffuse VOC emissions to air (see BAT 19); (xxv) a chemicals management system that includes an inventory of the hazardous substances and substances of very high concern used in the process(es); the potential for substitution of the substances that are listed in this inventory, focusing on those substances other than raw materials, is analysed periodically (e.g. annually) in order to identify possible new available and safer alternatives, with no or lower environmental impacts. Grp. note. Regulation (EC) No 1221/2009 of the European Parliament and of the Council establishes the European Union eco-management and audit scheme (EMAS), which is an example of an EMS consistent with this BAT. Grp. applicability. The level of detail and the degree of formalisation of the EMS will generally be related to the nature, scale and complexity of the installation, and the range of environmental impacts it may have. Grp. 1. In order to improve the overall environmental performance, BAT is to elaborate and implement an environmental management system (EMS) that incorporates all of the following features: Specifically for the chemical sector, BAT is also to incorporate the following features in the EMS: (a) chemical reaction equations, also showing side products; (b) simplified process flow sheets that show the origin of the emissions; (i) information, as comprehensive as is reasonably possible, about the chemical production process(es), including: (a) emission point(s); (b) average values and variability of flow and temperature; (c) average concentration and mass flow values of relevant substances/parameters and their variability (e.g. TVOC, CO, NOX, SOX, Cl2, HCl); (d) presence of other substances that may affect the waste gas treatment system(s) or plant safety (e.g. oxygen, nitrogen, water vapour, dust); (e) techniques used to prevent and/or reduce channelled emissions to air; (f) flammability, lower and higher explosive limits, reactivity; (g) monitoring methods (see BAT 8); (h) presence of substances classified as CMR 1A, CMR 1B or CMR 2; the presence of such substances may for example be assessed according to the criteria of Regulation (EC) No 1272/2008 on classification, labelling and packaging (CLP). (ii) information, as comprehensive as is reasonably possible, about channelled emissions to air, such as: (a) identification of the emission source(s); (b) characteristics of each emission source (e.g. fugitive or non-fugitive; static or moving; accessibility of the emission source; included in an LDAR programme or not); (1) physical state; (2) vapour pressure of the substance(s) in the liquid, pressure of the gas; (3) temperature; (4) composition (by weight for liquids or by volume for gases); (5) hazardous properties of the substance(s) or mixtures, including substances or mixtures classified as CMR 1A, CMR 1B or CMR 2; (c) the characteristics of the gas or liquid in contact with the emission source(s), including: (d) techniques used to prevent and/or reduce diffuse emissions to air; (e) monitoring (see BAT 20, BAT 21 and BAT 22). (iii) information, as comprehensive as is reasonably possible, about diffuse emissions to air, such as: Grp_for_diffuse. emissions. The information about diffuse emissions to air is particularly relevant for activities using large amounts of organic substances or mixtures (e.g. production of pharmaceuticals, production of large volumes of organic chemicals or of polymers). The information about fugitive emissions covers all emission sources in contact with organic substances with a vapour pressure greater than 0,3 kPa at 293,15 K. Sources of fugitive emissions connected to pipes whose diameter is small (e.g. smaller than 12,7 mm, i.e. 0,5 inch) may be excluded from the inventory. Equipment operated under subatmospheric pressure may be excluded from the inventory. Grp. applicability. The level of detail and the degree of formalisation of the inventory will generally be related to the nature, scale and complexity of the installation, and the range of environmental impacts it may have. Grp. 2. In order to facilitate the reduction of emissions to air, BAT is to establish, maintain and regularly review (including when a substantial change occurs) an inventory of channelled and diffuse emissions to air, as part of the environmental management system (see BAT 1), that incorporates all of the following features: Grp. 111. Environmental management systems (i) identification of potential OTNOC (e.g. failure of equipment critical to the control of channelled emissions to air, or equipment critical to the prevention of accidents or incidents that could lead to emissions to air (critical equipment)), of their root causes and of their potential consequences; (ii) appropriate design of critical equipment (e.g. equipment modularity and compartmentalisation, backup systems, techniques to obviate the need to bypass waste gas treatment during start-up and shutdown, high-integrity equipment, etc.); (iii) set-up and implementation of a preventive maintenance plan for critical equipment (see BAT 1 xii.); (iv) monitoring (i.e. estimating or, where this is possible, measuring) and recording of emissions and associated circumstances during OTNOC; (v) periodic assessment of the emissions occurring during OTNOC (e.g. frequency of events, duration, amount of pollutants emitted as recorded in point iv.) and implementation of corrective actions if necessary; (vi) regular review and update of the list of identified OTNOC under point i. following the periodic assessment of point v.; (vii) regular testing of backup systems. Grp. 3. In order to reduce the frequency of the occurrence of OTNOC and to reduce emissions to air during OTNOC, BAT is to set up and implement a risk-based OTNOC management plan as part of the environmental management system (see BAT 1) that includes all of the following features: Grp. 112. Other than normal operating conditions (OTNOC) Grp. description. The integrated waste gas management and treatment strategy is based on the inventory in BAT 2. It takes into account factors such as greenhouse gas emissions and the consumption or reuse of energy, water and materials associated with the use of the different techniques. Grp. 4. In order to reduce channelled emissions to air, BAT is to use an integrated waste gas management and treatment strategy that includes, in order of priority, process-integrated recovery and abatement techniques. Grp. description. The combined treatment of waste gases with similar characteristics ensures more effective and efficient treatment compared to the separate treatment of individual waste gas streams. The combination of waste gases is carried out considering plant safety (e.g. avoiding concentrations close to the lower/upper explosive limit), technical (e.g. compatibility of the individual waste gas streams, concentration of the substances concerned), environmental (e.g. maximising recovery of materials or pollutant abatement) and economic factors (e.g. distance between different production units). Care is taken that the combination of waste gases does not lead to the dilution of emissions. Grp. 5. In order to facilitate the recovery of materials and the reduction of channelled emissions to air, as well as to increase energy efficiency, BAT is to combine waste gas streams with similar characteristics, thus minimising the number of emission points. Grp. 6. In order to reduce channelled emissions to air, BAT is to ensure that the waste gas treatment systems are appropriately designed (e.g. considering the maximum flow rate and pollutant concentrations), operated within their design ranges, and maintained (through preventive, corrective, regular and unplanned maintenance) so as to ensure optimal availability, effectiveness and efficiency of the equipment. Grp. 1131. General techniques Grp. 7. BAT is to continuously monitor key process parameters (e.g. waste gas flow and temperature) of waste gas streams being sent to pretreatment and/or final treatment. Grp. 8. BAT is to monitor channelled emissions to air with at least the frequency given below and in accordance with EN standards. If EN standards are not available, BAT is to use ISO, national or other international standards that ensure the provision of data of an equivalent scientific quality. Substance/Parameter Process(es)/Source(s) Emission points Standard(s) Minimum monitoring frequency Monitoring associated with Ammonia (NH3) Use of SCR/SNCR Any stack EN 21877 Once every 6 months BAT 17 All other processes/sources BAT 18 Benzene All processes/sources Any stack No EN standard available Once every 6 months BAT 11 1,3-Butadiene All processes/sources Any stack No EN standard available Once every 6 months BAT 11 Carbon monoxide (CO) Thermal treatment Any stack with a CO mass flow of ≥ 2 kg/h Generic EN standards Continuous BAT 16 Any stack with a CO mass flow of < 2 kg/h EN 15058 Once every 6 months Process furnaces/heaters Any stack with a CO mass flow of ≥ 2 kg/h Generic EN standards Continuous BAT 36 Any stack with a CO mass flow of < 2 kg/h EN 15058 Once every 6 months All other processes/sources Any stack with a CO mass flow of ≥ 2 kg/h Generic EN standards Continuous BAT 18 Any stack with a CO mass flow of < 2 kg/h EN 15058 Once every year Chloromethane All processes/sources Any stack No EN standard available Once every 6 months BAT 11 CMR substances other than CMR substances covered elsewhere in this table All other processes/sources Any stack No EN standard available Once every 6 months BAT 11 Dichloromethane All processes/sources Any stack No EN standard available Once every 6 months BAT 11 Dust All processes/sources Any stack with dust mass flow ≥ 3 kg/h Generic EN standards, EN 13284-1 and EN 13284-2 Continuous BAT 14 Any stack with dust mass flow < 3 kg/h EN 13284-1 Once every year Elemental chlorine (Cl2) All processes/sources Any stack No EN standard available Once every year BAT 18 Ethylene dichloride (EDC) All processes/sources Any stack No EN standard available Once every 6 months BAT 11 Ethylene oxide All processes/sources Any stack No EN standard available Once every 6 months BAT 11 Formaldehyde All processes/sources Any stack EN standard under development Once every 6 months BAT 11 Gaseous chlorides All processes/sources Any stack EN 1911 Once every year BAT 18 Gaseous fluorides All processes/sources Any stack No EN standard available Once every year BAT 18 Hydrogen cyanide (HCN) All processes/sources Any stack No EN standard available Once every year BAT 18 Lead and its compounds All processes/sources Any stack EN 14385 Once every 6 months BAT 14 Nickel and its compounds All processes/sources Any stack EN 14385 Once every 6 months BAT 14 Nitrous oxide (N2O) All processes/sources Any stack EN ISO 21258 Once every year – Nitrogen oxides (NOX) Thermal treatment Any stack with a NOX mass flow of ≥ 2,5 kg/h Generic EN standards Continuous BAT 16 Any stack with a NOX mass flow of < 2,5 kg/h EN 14792 Once every 6 months Process furnaces/heaters Any stack with a NOX mass flow of ≥ 2,5 kg/h Generic EN standards Continuous BAT 36 Any stack with a NOX mass flow of < 2,5 kg/h EN 14792 Once every 6 months All other processes/sources Any stack with a NOX mass flow of ≥ 2,5 kg/h Generic EN standards Continuous BAT 18 Any stack with a NOX mass flow of < 2,5 kg/h EN 14792 Once every 6 months PCDD/F Thermal treatment Any stack EN 1948-1, EN 1948-2, EN 1948-3 Once every 6 months BAT 12 PM2,5 and PM10 All processes/sources Any stack EN ISO 23210 Once every year BAT 14 Propylene oxide All processes/sources Any stack No EN standard available Once every 6 months BAT 11 Sulphur dioxide (SO2) Thermal treatment Any stack with a SO2 mass flow of ≥ 2,5 kg/h Generic EN standards Continuous BAT 16 Any stack with a SO2 mass flow of < 2,5 kg/h EN 14791 Once every 6 months Process furnaces/heaters Any stack with a SO2 mass flow of ≥ 2,5 kg/h Generic EN standards Continuous BAT 18, BAT 36 Any stack with a SO2 mass flow of < 2,5 kg/h EN 14791 Once every 6 months All other processes/sources Any stack with a SO2 mass flow of ≥ 2,5 kg/h Generic EN standards Continuous BAT 18 Any stack with a SO2 mass flow of < 2,5 kg/h EN 14791 Once every 6 months Tetrachloromethane All processes/sources Any stack No EN standard available Once every 6 months BAT 11 Toluene All processes/sources Any stack No EN standard available Once every 6 months BAT 11 Trichloromethane All processes/sources Any stack No EN standard available Once every 6 months BAT 11 Total volatile organic carbon (TVOC) Production of polyolefins Any stack with a TVOC mass flow of ≥ 2 kg C/h Generic EN standards Continuous BAT 11, BAT 25 Any stack with a TVOC mass flow of < 2 kg C/h EN 12619 Once every 6 months Production of synthetic rubbers Any stack with a TVOC mass flow of ≥ 2 kg C/h Generic EN standards Continuous BAT 11, BAT 32 Any stack with a TVOC mass flow of < 2 kg C/h EN 12619 Once every 6 months All other processes/sources Any stack with a TVOC mass flow of ≥ 2 kg C/h Generic EN standards Continuous BAT 11 Any stack with a TVOC mass flow of < 2 kg C/h EN 12619 Once every 6 months Grp. 1132. Monitoring Grp. applicability. Recovery may be restricted where the energy demand is excessive due to the low concentration of the compound(s) concerned in the process off-gas(es). Reuse may be restricted due to product quality specifications. Grp. 9. In order to increase resource efficiency and to reduce the mass flow of organic compounds sent to the final waste gas treatment, BAT is to recover organic compounds from process off-gases by using one or a combination of the techniques given below and to reuse them. Technique Description a. Absorption (regenerative) See Section 1.4.1. b. Adsorption (regenerative) See Section 1.4.1. c. Condensation See Section 1.4.1. Grp. description. Process off-gases with a high calorific value are burnt as a fuel in a combustion unit (gas engine, boiler, process heater or furnace) and the heat is recovered as steam or for electricity generation, or to provide heat to the process. For process off-gases with low VOC concentrations (e.g. < 1 g/Nm3), pre-concentration steps may be applied using adsorption (rotor or fixed bed, with activated carbon or zeolites), in order to increase the calorific value of the process off-gases. Molecular sieves (smoothers), typically composed of zeolites, may be used to level down high variations (e.g. concentration peaks) of VOC concentrations in the process off-gases. Grp. applicability. Sending process off-gases to a combustion unit may be restricted due to the presence of contaminants or due to safety considerations. Grp. 10. In order to increase energy efficiency and to reduce the mass flow of organic compounds sent to the final waste gas treatment, BAT is to send process off-gases with a sufficient calorific value to a combustion unit that is, if technically possible, combined with heat recovery. BAT 9 has priority over sending process off-gases to a combustion unit. Grp_11_table. 11. In order to reduce channelled emissions to air of organic compounds, BAT is to use one or a combination of the techniques given below. Technique Description Applicability a. Adsorption See Section 1.4.1. Generally applicable. b. Absorption See Section 1.4.1. Generally applicable. c. Catalytic oxidation See Section 1.4.1. Applicability may be restricted by the presence of catalyst poisons in the waste gases. d. Condensation See Section 1.4.1. Generally applicable. e. Thermal oxidation See Section 1.4.1. Applicability of recuperative and regenerative thermal oxidation to existing plants may be restricted by design and/or operational constraints. Applicability may be restricted where the energy demand is excessive due to the low concentration of the compound(s) concerned in the process off-gases. f. Bioprocesses See Section 1.4.1. Only applicable to the treatment of biodegradable compounds. Substance/Parameter BAT-AEL (mg/Nm3) (Daily average or average over the sampling period) Total volatile organic carbon (TVOC) < 1-20 Sum of VOCs classified as CMR 1A or 1B < 1-5 Sum of VOCs classified as CMR 2 < 1-10 Benzene < 0,5-1 1,3-Butadiene < 0,5-1 Ethylene dichloride < 0,5-1 Ethylene oxide < 0,5-1 Propylene oxide < 0,5-1 Formaldehyde 1-5 Chloromethane < 0,5-1 Dichloromethane < 0,5-1 Tetrachloromethane < 0,5-1 Toluene < 0,5-1 Trichloromethane < 0,5-1 The associated monitoring is given in BAT 8. Grp_12_table. 12. In order to reduce channelled emissions to air of PCDD/F from thermal treatment of waste gases containing chlorine and/or chlorinated compounds, BAT is to use techniques a. and b., and one or a combination of techniques c. to e., given below. Technique Description Applicability Specific techniques to reduce PCDD/F emissions a. Optimised catalytic or thermal oxidation See Section 1.4.1. Generally applicable. b. Rapid waste-gas cooling Rapid cooling of waste gases from temperatures above 400 °C to below 250 °C to prevent the de novo synthesis of PCDD/F. Generally applicable. c. Adsorption using activated carbon See Section 1.4.1. Generally applicable. d. Absorption See Section 1.4.1. Generally applicable. Other techniques not primarily used to reduce PCDD/F emissions e. Selective catalytic reduction (SCR) See Section 1.4.1. When SCR is used for NOX abatement, an adequate catalyst surface of the SCR system also provides for the partial reduction of the emissions of PCDD/F. Applicability to existing plants may be restricted by space availability and/or by the presence of catalyst poisons in the waste gases. Substance/Parameter BAT-AEL (ng I-TEQ/Nm3) (Average over the sampling period) PCDD/F < 0,01-0,05 The associated monitoring is given in BAT 8. Grp. 1133. Organic compounds Grp. applicability. Recovery may be restricted where the energy demand for dust purification or decontamination is excessive. Reuse may be restricted due to product quality specifications. Grp. 13. In order to increase resource efficiency and to reduce the mass flow of dust and particulate-bound metals sent to the final waste gas treatment, BAT is to recover materials from process off-gases by using one or a combination of the techniques given below and to reuse them. Technique Description a. Cyclone See Section 1.4.1. b. Fabric filter See Section 1.4.1. c. Absorption See Section 1.4.1. Grp_14_table. 13. In order to reduce channelled emissions to air of dust and particulate-bound metals, BAT is to use one or a combination of the techniques given below. Technique Description Applicability a. Absolute filter See Section 1.4.1. Applicability may be limited in the case of sticky dust or when the temperature of the waste gases is below the dew point. b. Absorption See Section 1.4.1. Generally applicable. c. Fabric filter See Section 1.4.1. Applicability may be limited in the case of sticky dust or when the temperature of the waste gases is below the dew point. d. High-efficiency air filter See Section 1.4.1. Generally applicable. e. Cyclone See Section 1.4.1. Generally applicable. f. Electrostatic precipitator See Section 1.4.1. Generally applicable. Substance/Parameter BAT-AEL (mg/Nm3) (Daily average or average over the sampling period) Dust < 1-5 Lead and its compounds, expressed as Pb < 0,01-0,1 Nickel and its compounds, expressed as Ni < 0,02-0,1 The associated monitoring is given in BAT 8. Grp. 1134. Dust (including PM10 and PM2,5) and particulate-bound metals Grp. description. See Section 1.4.1. Grp. applicability. Recovery may be restricted where the energy demand is excessive due to the low concentration of the compound(s) concerned in the process off-gas(es). Reuse may be restricted due to product quality specifications. Grp. 15. In order to increase resource efficiency and to reduce the mass flow of inorganic compounds sent to the final waste gas treatment, BAT is to recover inorganic compounds from process off-gases by using absorption and to reuse them. Grp_16_table. 14. In order to reduce channelled emissions to air of CO, NOX and SOX from thermal treatment, BAT is to use technique c. and one or a combination of the other techniques given below. Technique Description Main inorganic compounds targeted Applicability a. Choice of fuel See Section 1.4.1. NOX, SOX Generally applicable. b. Low-NOX burner See Section 1.4.1. NOX Applicability to existing plants may be restricted by design and/or operational constraints. c. Optimisation of catalytic or thermal oxidation See Section 1.4.1. CO, NOX Generally applicable. d. Removal of high levels of NOX precursors Remove (if possible, for reuse) high levels of NOX precursors prior to thermal or catalytic oxidation, e.g. by absorption, adsorption or condensation. NOX Generally applicable. e. Absorption See Section 1.4.1. SOX Generally applicable. f. Selective catalytic reduction (SCR) See Section 1.4.1. NOX Applicability to existing plants may be restricted by space availability. g. Selective non-catalytic reduction (SNCR) See Section 1.4.1. NOX Applicability to existing plants may be restricted by the residence time needed for the reaction. Substance/Parameter BAT-AEL (mg/Nm3) (Daily average or average over the sampling period) Nitrogen oxides (NOX) from catalytic oxidation 5-30 Nitrogen oxides (NOX) from thermal oxidation 5-130 Carbon monoxide (CO) No BAT-AEL The associated monitoring is given in BAT 8. The BAT-AEL for channelled emissions to air of SO2 is given in Table 1.6. Grp_17_table. 15. In order to reduce channelled emissions to air of ammonia from the use of selective catalytic reduction (SCR) or selective non-catalytic reduction (SNCR) for the abatement of NOX emissions (ammonia slip), BAT is to optimise the design and/or operation of SCR or SNCR (e.g. optimised reagent to NOX ratio, homogeneous reagent distribution and optimum size of the reagent drops). Substance/Parameter BAT-AEL (mg/Nm3) (Average over the sampling period) Ammonia (NH3) from SCR/SNCR < 0,5-8 The associated monitoring is given in BAT 8. Grp_18_table. 16. In order to reduce channelled emissions to air of inorganic compounds other than channelled emissions to air of ammonia from the use of selective catalytic reduction (SCR) or selective non-catalytic reduction (SNCR) for the abatement of NOX emissions), channelled emissions to air of CO, NOX and SOX from the use of thermal treatment, and channelled emissions to air of NOX from process furnaces/heaters, BAT is to use one or a combination of the techniques given below. Technique Description Main inorganic compounds targeted Applicability Specific techniques to reduce emissions to air of inorganic compounds a. Absorption See Section 1.4.1. Cl2, HCl, HCN, HF, NH3, NOX, SOX Generally applicable. b. Adsorption See Section 1.4.1. For the removal of inorganic substances, the technique is often used in combination with a dust abatement technique (see BAT 14). HCl, HF, NH3, SOX Generally applicable. c. Selective catalytic reduction (SCR) See Section 1.4.1. NOX Applicability to existing plants may be restricted by space availability. d. Selective non-catalytic reduction (SNCR) See Section 1.4.1. NOX Applicability to existing plants may be restricted by the residence time needed for the reaction. Other techniques not primarily used to reduce emissions to air of inorganic compounds e. Catalytic oxidation See Section 1.4.1. NH3 Applicability may be restricted by the presence of catalyst poisons in the waste gases. f. Thermal oxidation See Section 1.4.1. NH3, HCN Applicability of recuperative and regenerative thermal oxidation to existing plants may be restricted by design and/or operational constraints. The applicability may be restricted where the energy demand is excessive due to the low concentration of the compound(s) concerned in the process off-gases. Substance/Parameter BAT-AEL (mg/Nm3) (Daily average or average over the sampling period) Ammonia (NH3) 2-10 Elemental chlorine (Cl2) < 0,5-2 Gaseous fluorides, expressed as HF ≤ 1 Hydrogen cyanide (HCN) < 0,1-1 Gaseous chlorides, expressed as HCl 1-10 Nitrogen oxides (NOX) 10-150 Sulphur oxides (SO2) < 3-150 The associated monitoring is given in BAT 8. Grp. 1135. Inorganic compounds Grp. 113. Channelled emissions to air (i) Estimating the annual quantity of diffuse VOC emissions (see BAT 20). (ii) Monitoring diffuse VOC emissions from the use of solvents by compiling a solvent mass balance, if applicable (see BAT 21). (a) Listing of equipment identified as relevant fugitive VOC emission sources in the inventory of diffuse VOC emissions (see BAT 2). (1) Leaky equipment. Typical criteria could be a leak threshold, above which equipment is considered leaky, and/or the visualisation of a leak with OGI cameras. This depends on the characteristics of the emission source (e.g. accessibility) and the hazardous properties of the emitted substance(s). (2) Maintenance and/or repair actions to be carried out. A typical criterion could be a VOC concentration threshold triggering the maintenance or repair action (maintenance/repair threshold). The maintenance/repair threshold is generally equal to or higher than the leak threshold. This depends on the characteristics of the emission source (e.g. accessibility) and the hazardous properties of the emitted substance(s). For the first LDAR programme, it is generally not higher than 5000 ppmv for VOCs other than VOCs classified as CMR 1A or 1B, and 1000 ppmv for VOCs classified as CMR 1A or 1B. For subsequent LDAR programmes, the maintenance/repair threshold is lowered (see point vi. a.) and not higher than 1000 ppmv for VOCs other than VOCs classified as CMR 1A or 1B, and 500 ppmv for VOCs classified as CMR 1A or 1B, targeting 100 ppmv. (b) Definition of criteria associated with the following: (c) Measuring fugitive VOC emissions from equipment listed under point iii. a. (see BAT 22). (d) Carrying out maintenance and/or repair actions (see BAT 23, techniques e. and f.), as soon as possible and where necessary according to the criteria defined in point iii. b. Maintenance and repair actions are prioritised according to the hazardous properties of the emitted substance(s), the significance of the emissions and/or operational constraints. The effectiveness of the maintenance and/or repair actions is verified according to point iii. c., leaving enough time after the intervention (e.g. 2 months). (e) Filling in the database mentioned in point v. (iii) Establishing and implementing a leak detection and repair (LDAR) programme for fugitive VOC emissions. The LDAR programme typically lasts from 1 to 5 years depending on the nature, scale and complexity of the plant (5 years may correspond to large plants with a high number of emission sources). The LDAR programme includes all of the following features: (a) Listing of equipment identified as relevant non-fugitive VOC emission sources in the inventory of diffuse VOC emissions (see BAT 2). (b) Monitoring non-fugitive VOC emissions from equipment listed under point iv. a. (see BAT 22). (c) Planning and implementing techniques to reduce non-fugitive VOC emissions (see BAT 23, techniques a., c. and g. to j.). The planning and implementation of the techniques are prioritised according to the hazardous properties of the emitted substance(s), the significance of the emissions and/or operational constraints. (d) Filling in the database mentioned in point v. (iv) Establishing and implementing a detection and reduction programme for non-fugitive VOC emissions that includes all of the following features: (a) equipment design specifications (including the date and description of any design changes); (b) the equipment maintenance, repair, upgrade, or replacement actions, performed or planned, and their date of implementation; (c) the equipment that could not be maintained, repaired, upgraded or replaced due to operational constraints; (d) the results of the measurements or monitoring, including the concentration(s) of the emitted substance(s), the calculated leak rate (as kg/year), the recording from OGI cameras (e.g. from the last LDAR programme) and the date of the measurements or monitoring; (e) the annual quantity of diffuse VOC emissions (as fugitive and non-fugitive emissions), including information on non-accessible sources and accessible sources not monitored during the year. (v) Establishing and maintaining a database, for diffuse VOC emissions sources that are identified in the inventory mentioned in BAT 2, for keeping record of: (a) lowering the leak and/or maintenance/repair thresholds (see point iii. b.); (b) reviewing the prioritisation of equipment to be monitored, giving higher priority to (the type of) equipment identified as leaky during the previous LDAR programme; (c) planning the maintenance, repair, upgrade or replacement of equipment that could not be performed during the previous LDAR programme due to operational constraints. (vi) Reviewing and updating the LDAR programme periodically. This may include the following: (a) monitoring non-fugitive VOC emissions from equipment where maintenance, repair, upgrade or replacement actions were implemented, in order to determine if those actions were successful; (b) planning the maintenance, repair, upgrade or replacement actions that could not be performed due to operational constraints. (vii) Reviewing and updating the detection and reduction programme for non-fugitive VOC emissions. This may include the following: Grp. applicability. The features points iii., iv., vi., and vii. are only applicable to sources of diffuse VOC emissions for which monitoring according to BAT 22 is applicable. The level of detail of the management system for diffuse VOC emissions will be proportionate to the nature, scale and complexity of the plant, and the range of environmental impacts it may have. Grp. 19. In order to prevent or, where that is not practicable, to reduce diffuse VOC emissions to air, BAT is to elaborate and implement a management system for diffuse VOC emissions, as part of the environmental management system (see BAT 1), that includes all of the following features: Grp. 1141. Management system for diffuse VOC emissions (1) chemical properties of the substance (e.g. vapour pressure, molecular mass); (2) process operating data (e.g. operating time, product quantity, ventilation); (3) characteristics of the emission source (e.g. tank diameter, colour, shape). Grp. note. The estimation of the diffuse VOC emissions to air takes into account the results of the monitoring carried out according to BAT 21 and/or to BAT 22. For the purpose of the estimation, channelled emissions may be counted as non-fugitive emissions when the inherent characteristics of the waste gas stream (e.g. low velocities, variability of the flow rate and concentration) do not allow an accurate measurement according to BAT 8. The main sources of uncertainty of the estimation are identified, and corrective actions are implemented to reduce the uncertainty. Technique Description Type of emissions a. Use of emission factors See Section 1.4.2. Fugitive and/or non-fugitive b. Use of a mass balance Estimation based on the difference in the mass of the substance inputs to and outputs from the plant/production unit, taking into account the generation and destruction of the substance in the plant/production unit. A mass balance may also consist of measuring the concentration of VOCs in the product (e.g. raw material or solvent). c. Use of thermodynamic models Estimation using the laws of thermodynamics applied to equipment (e.g. tanks) or particular steps of a production process. The following data are generally used as input for the model: Grp. 20. BAT is to estimate fugitive and non-fugitive VOC emissions to air separately at least once every year by using one or a combination of the techniques given below, as well as to determine the uncertainty of this estimation. The estimation distinguishes between VOCs classified as CMR 1A or 1B and VOCs that are not classified as CMR 1A or 1B. (1) identification and documentation of solvent inputs and outputs (e.g. channelled and diffuse emissions to air, emissions to water, solvent output in waste); (2) substantiated quantification of each relevant solvent input and output and recording of the methodology used (e.g. measurement, estimation by using emission factors, estimation based on operational parameters); (3) identification of the main sources of uncertainty of the aforementioned quantification, and implementation of corrective actions to reduce the uncertainty; (4) regular update of solvent input and output data. (5) malfunctions of the waste gas treatment system: the date and period of time are recorded; (6) changes that may influence air/gas flow rates (e.g. replacement of fans): the date and type of change are recorded. Grp. applicability. This BAT may not apply to the production of polyolefins, PVC or synthetic rubbers. This BAT may not be applicable to plants whose total annual consumption of solvents is lower than 50 tonnes. The level of detail of the solvent mass balance will be proportionate to the nature, scale and complexity of the plant, and the range of environmental impacts it may have, as well as to the type and quantity of solvents used. Grp. 21. BAT is to monitor diffuse VOC emissions from the use of solvents by compiling, at least once every year, a solvent mass balance of the solvent inputs and outputs of the plant, as defined in Part 7 of Annex VII to Directive 2010/75/EU and to minimise the uncertainty of the solvent mass balance data by using all of the techniques given below. Technique Description a. Full identification and quantification of the relevant solvent inputs and outputs, including the associated uncertainty This includes: b. Implementation of a solvent tracking system A solvent tracking system aims to keep control of both the used and unused quantities of solvents (e.g. by weighing unused quantities returned to storage from the application area). c. Monitoring of changes that may influence the uncertainty of the solvent mass balance data Any change that could influence the uncertainty of the solvent mass balance data is recorded, such as: Grp. note. Optical gas imaging (OGI) is a useful complementary technique to the method EN 15446 (sniffing) in order to identify sources of fugitive VOC emissions and is particularly relevant in the case of inaccessible sources (see Section 1.4.2.). This technique is described in EN 17628. In the case of non-fugitive emissions, measurements may be complemented by the use of thermodynamic models. Where large amounts (e.g. above 80 t/yr) of VOCs are used/consumed, the quantification of VOC emissions from the plant with tracer correlation (TC) or with optical absorption-based techniques, such as differential absorption light detection and ranging (DIAL) or solar occultation flux (SOF), is a useful complementary technique (see Section 1.4.2.). These techniques are described in EN 17628. (1) 1 tonne of VOCs per year in the case of VOCs classified as CMR 1A or 1B; or (2) 5 tonnes of VOCs per year in the case of other VOCs. (3) 1 tonne of VOCs per year in the case of VOCs classified as CMR 1A or 1B; or (4) 5 tonnes of VOCs per year in the case of other VOCs. Grp. applicability. BAT 22 only applies when the annual quantity of diffuse VOC emissions from the plant estimated according to BAT 20 is greater than the following: For fugitive emissions: For non-fugitive emissions: Grp. 22. BAT is to monitor diffuse VOC emissions to air with at least the frequency given below and in accordance with EN standards. If EN standards are not available, BAT is to use ISO, national or other international standards that ensure the provision of data of an equivalent scientific quality. Type of sources of diffuse VOC emissions Type of VOCs Standard(s) Minimum monitoring frequency Sources of fugitive emissions VOCs classified as CMR 1A or 1B EN 15446 Once every year VOCs not classified as CMR 1A or 1B Once during the period covered by each LDAR programme (see BAT 19 point iii.) Sources of non-fugitive emissions VOCs classified as CMR 1A or 1B EN 17628 Once every year VOCs not classified as CMR 1A or 1B Once every year Grp. 1142. Monitoring (1) minimising pipe lengths; (2) reducing the number of pipe connectors (e.g. flanges) and valves; (3) using welded fittings and connections; (4) using compressed air or gravity for material transfer. (5) bellow valves or double packing seals or equally effective equipment; (6) magnetically driven or canned pumps/compressors/agitators, or pumps/compressors/agitators using double seals and a liquid barrier; (7) certified high-quality gaskets (e.g. according to EN 13555) that are tightened according to technique e.; (8) closed sampling system. (9) emissions of CMR substances or substances with acute toxicity; and/or (10) emissions from equipment with high-leaking potential; and/or (11) leaks from processes operated at high pressures (e.g. between 300 bar and 2000 bar). (12) for existing plants; and/or (13) by safety concerns (e.g. avoiding concentrations close to the lower explosive limit). (14) tightening of gaskets by personnel that is qualified according to EN 1591-4 and using the designed gasket stress (e.g. calculated according to EN 1591-1); (15) installing tight caps on open ends; (16) using flanges selected and assembled according to EN 13555. (17) gaskets; (18) sealing elements (e.g. tank lid); (19) packing material (e.g. valve stem packing material). (20) reducing the use of solvents and/or using solvents with lower volatility; (21) reducing the formation of side products containing VOCs; (22) lowering the operating temperature; (23) lowering the VOC content in the final product. (24) reducing the frequency and duration of reactor and vessel openings; (25) preventing corrosion by lining or coating of equipment, by painting pipes (for external corrosion) and by using corrosion inhibitors for materials in contact with equipment. (26) vapour balancing (see Section 1.4.3); (27) closed systems for solid/liquid and liquid/liquid phase separations; (28) closed systems for cleaning operations; (29) closed sewers and/or waste water treatment plants; (30) closed sampling systems; (31) closed storage areas. (32) installing oil creaming systems on open surfaces; (33) periodically skimming open surfaces (e.g. removing floating matter); (34) installing anti-evaporation floating elements on open surfaces; (35) treating waste water streams to remove VOCs and send the VOCs to recovery (see BAT 9 and BAT 10) and/or abatement (see BAT 11); (36) installing floating roofs on tanks; (37) using fixed-roof tanks connected to a waste gas treatment. Grp. 1. The use of techniques to prevent or, where that is not practicable, to reduce diffuse VOC emissions to air is prioritised according to the hazardous properties of the emitted substance(s) and/or the significance of the emissions. Technique Description Type of emissions Applicability Prevention techniques a. Limiting the number of emission sources This includes: Fugitive and non-fugitive emissions Applicability may be restricted by operational constraints in the case of existing plants. b. Use of high-integrity equipment High-integrity equipment includes, but is not limited to: The use of high-integrity equipment is especially relevant to prevent or minimise: High-integrity equipment is selected, installed and maintained according to the type of process and the process operating conditions. Fugitive emissions Applicability may be restricted by operational constraints in the case of existing plants. Generally applicable to new plants and major plant upgrades. c. Collecting diffuse emissions and treating off-gases Collecting diffuse VOC emissions (e.g. from compressor seals, vents and purge lines) and sending them to recovery (see BAT 9 and BAT 10) and/or abatement (see BAT 11). Fugitive and non-fugitive emissions Applicability may be restricted: Other techniques d. Facilitating access and/or monitoring activities To ease maintenance and/or monitoring activities, the access to potentially leaky equipment is facilitated, e.g. by installing platforms, and/or drones are used for monitoring. Fugitive emissions Applicability may be restricted by operational constraints in the case of existing plants. e. Tightening This includes: Fugitive emissions Generally applicable. f. Replacement of leaky equipment and/or parts This includes the replacement of: Fugitive emissions Generally applicable. g. Reviewing and updating process design This includes: Non-fugitive emissions Applicability may be restricted in the case of existing plants due to operational constraints. h. Reviewing and updating operating conditions This includes: Non-fugitive emissions Generally applicable. i. Using closed systems This includes: Off-gases from closed systems are sent to recovery (see BAT 9 and BAT 10) and/or abatement (see BAT 11). Non-fugitive emissions Applicability may be restricted by operational constraints in the case of existing plants and/or by safety concerns. j. Using techniques to minimise emissions from surfaces This includes: Non-fugitive emissions Applicability may be restricted by operational constraints in the case of existing plants. Grp. 23. In order to prevent or, where that is not practicable, to reduce diffuse VOC emissions to air, BAT is to use a combination of the techniques given below with the following order of priority. Grp. 1143. Prevention or reduction of diffuse VOC emissions Grp_1144_table. 17. BAT conclusions for the use of solvents or the reuse of recovered solvents The emission levels for the use of solvents or the reuse of recovered solvents given below are associated with the general BAT conclusions given in Section 1.1 and Section 1.1.4.3. Parameter BAT-AEL (percentage of the solvent inputs) (yearly average) Diffuse VOC emissions ≤ 5 % The associated monitoring is given in BAT 20, BAT 21 and BAT 22. Grp. 114. Diffuse VOC emissions to air Grp. 11. General BAT conclusions Grp. note. The measurement samples are taken at the point of transition from the closed to the open system where the polyolefin comes into contact with the atmosphere. The closed system refers to the part of the production process where the materials (e.g. reactants, solvents, suspension agents) are not in contact with the atmosphere. It includes the polymerisation steps, the reuse and recovery of materials. The open system refers to the part of the production process where the polyolefins come into contact with the atmosphere. It includes the finishing steps (e.g. drying, blending) as well as the transfer, handling and storage of polyolefins. When the transition point between the open and the closed system cannot be clearly identified, the measurement samples are taken at an appropriate point. Grp. applicability. Measurements do not apply to production processes only made up of a closed system. Grp. 24. BAT is to monitor the TVOC concentration in polyolefin products, at least once every year for each representative polyolefin grade produced during the same year, in accordance with EN standards. If EN standards are not available, BAT is to use ISO, national or other international standards that ensure the provision of data of an equivalent scientific quality. Polyolefin product Standard(s) Monitoring associated with HDPE, LDPE, LLDPE No EN standard available BAT 20, BAT 25 PP EPS, GPPS, HIPS Grp_25_table. 18. In order to increase resource efficiency and to reduce emissions to air of organic compounds, BAT is to use all of the techniques given below, as far as applicable. Technique Description Applicability a. Chemical agents with low boiling points Solvents and suspension agents with low boiling points are used. Applicability may be restricted by operational constraints. b. Lowering the VOC content in the polymer The VOC content in the polymer is lowered, e.g. by using low-pressure separation, stripping or closed-loop nitrogen purge systems, devolatilisation extrusion (see Section 1.4.3). The techniques for lowering the VOC content depend on the type of polymer product and production process. Devolatilisation extrusion may be restricted by product specifications for the production of HDPE, LDPE and LLDPE. c. Collection and treatment of process off-gases Process off-gases arising from the use of technique b. as well as from the finishing step, e.g. extrusion and degassing silos, are collected and sent to recovery (see BAT 9 and BAT 10) and/or abatement (see BAT 11). Applicability may be restricted by operational constraints and/or due to safety concerns (e.g. avoiding concentrations close to the lower/upper explosive limit). Polyolefin product Unit BAT-AEL (Yearly average) HDPE g C per kg of polyolefins produced 0,3-1,0 LDPE 0,1-1,4 LLDPE 0,1-0,8 PP 0,1-0,9 GPPS and HIPS < 0,1 EPS < 0,6 The associated monitoring is given in BAT 8, BAT 20, BAT 22 and BAT 24. The monitoring of TVOC emissions to air includes all emissions from the following process steps, where the emissions are identified as relevant in the inventory given in BAT 2: storage and handling of raw materials, polymerisation, recovery of materials and pollutant abatement, finishing of the polymer (e.g. extrusion, drying, blending) as well as the transfer, handling and storage of polymers. Grp. 121. BAT conclusions for the production of polyolefins Grp. 26. BAT is to monitor channelled emissions to air with at least the frequency given below and in accordance with EN standards. If EN standards are not available, BAT is to use ISO, national or other international standards that ensure the provision of data of an equivalent scientific quality. Substance Emission points Standard(s) Minimum monitoring frequency Monitoring associated with VCM Any stack with a VCM mass flow of ≥ 25 g/h Generic EN standards Continuous BAT 29 Any stack with a VCM mass flow of < 25 g/h No EN standard available Once every 6 months Grp. note. The samples of the PVC slurry/latex are taken at the point of transition from the closed to the open system where the PVC slurry/latex comes into contact with the atmosphere. The closed system refers to the part of the production process where the PVC slurry/latex is not in contact with the atmosphere. It generally includes the polymerisation steps, the reuse and recovery of VCM. The open system is the part of the system where the PVC slurry/latex comes into contact with the atmosphere. It includes the finishing steps (e.g. drying and blending) as well as the transfer, handling and storage of PVC. Grp. 27. BAT is to monitor the residual vinyl chloride monomer concentration in PVC slurry/latex, at least once every year for each representative PVC grade produced during the same year, in accordance with EN standards. Substance Standard(s) Monitoring associated with VCM EN ISO 6401 BAT 30 Grp. applicability. Recovery may be restricted where the energy demand is excessive due to the low concentration of the compound(s) concerned in the process off-gas(es). Grp. 28. In order to increase resource efficiency and to reduce the mass flow of organic compounds sent to the final waste gas treatment, BAT is to recover the vinyl chloride monomer from process off-gases by using one or a combination of the techniques given below, and to reuse the recovered monomer. Technique Description a. Absorption (regenerative) See Section 1.4.1. b. Adsorption (regenerative) See Section 1.4.1. c. Condensation See Section 1.4.1. Grp_29_table. 19. In order to reduce channelled emissions to air of vinyl chloride monomer from the recovery of vinyl chloride monomer, BAT is to use one or a combination of the techniques given below. Technique Description Applicability a. Absorption See Section 1.4.1. Generally applicable b. Adsorption See Section 1.4.1. c. Condensation See Section 1.4.1. d. Thermal oxidation See Section 1.4.1. Applicability of recuperative and regenerative thermal oxidation to existing plants may be restricted by design and/or operational constraints. Applicability may be restricted where the energy demand is excessive due to the low concentration of the compound(s) concerned in the process off-gases. Substance BAT-AEL (mg/Nm3) (Daily average or average over the sampling period) VCM < 0,5-1 The associated monitoring is given in BAT 26. (1) storing VCM in refrigerated tanks at atmospheric pressure or in pressurised tanks at ambient temperature; (2) using refrigerated reflux condensers or connecting tanks for VCM recovery (see BAT 28) and/or abatement (see BAT 29). (3) reducing the frequency and duration of reactor openings; (4) venting off-gases from latex storage tanks and from connections to VCM recovery (see BAT 28) and/or abatement (see BAT 29) prior to opening the reactor; (5) flushing the reactor with inert gas prior to opening and venting off-gases to VCM recovery (see BAT 28) and/or abatement (see BAT 29); (6) draining the liquid content of the reactor to closed vessels prior to opening the reactor; (7) cleaning the reactor with water prior to opening and draining the water to the stripping system. Grp. 30. In order to reduce emissions to air of vinyl chloride monomer, BAT is to use all of the techniques given below. Technique Description a. Appropriate VCM storage facilities This includes: b. Vapour balancing See Section 1.4.3. c. Minimisation of emissions of residual VCM from equipment This includes: d. Lowering the VCM content in the polymer by stripping See Section 1.4.3. e. Collection and treatment of process off-gases Process off-gases from the use of technique d. are collected and sent to VCM recovery (see BAT 28) and/or abatement (see BAT 29). PVC type Unit BAT-AEL (Yearly average) S-PVC g VCM per kg of PVC produced 0,01-0,045 E-PVC 0,25-0,3 The associated monitoring is given in BAT 20, BAT 22, BAT 26 and BAT 27. The monitoring of VCM emissions to air includes all emissions from the following process steps or equipment, where the emissions are identified as relevant in the inventory given in BAT 2: finishing, e.g. drying and blending; transfer, handling and storage; reactor openings; gasholders; waste water treatment plants; recovery and/or abatement of VCM. PVC type Unit BAT-AEL (Yearly average) S-PVC g VCM per kg of PVC produced 0,01-0,03 E-PVC 0,2-0,4 The associated monitoring is given in BAT 27. Grp. 122. BAT conclusions for the production of polyvinyl chloride (PVC) Grp. note. The samples are taken after lowering the VOC content in the polymer (see BAT 32 a.) where the synthetic rubber comes into contact with the atmosphere. Grp. applicability. Measurements do not apply to production processes only made up of a closed system. Grp. 31. BAT is to monitor the TVOC concentration in synthetic rubbers, at least once every year for each representative synthetic rubber grade produced during the same year, in accordance with EN standards. If EN standards are not available, BAT is to use ISO, national or other international standards that ensure the provision of data of an equivalent scientific quality. Substance/Parameter Standard(s) Monitoring associated with VOCs No EN standard available BAT 32 Grp_32_table. 112. In order to reduce emissions to air of organic compounds, BAT is to use one or a combination of the techniques given below. Technique Description a. Lowering the VOC content in the polymer The VOC content in the polymer is lowered by using stripping or devolatilisation extrusion (see Section 1.4.3). b. Collection and treatment of process off-gases Process off-gases are collected and sent to recovery (see BAT 9 and BAT 10) and/or abatement (see BAT 11). Substance/Parameter Unit BAT-AEL (Yearly average) TVOC g C per kg of synthetic rubber produced 0,2-4,2 The associated monitoring is given in BAT 8, BAT 20, BAT 22 and BAT 31. The monitoring of TVOC emissions to air includes all emissions from the following process steps, where the emissions are identified as relevant in the inventory given in BAT 2: storage of raw materials, polymerisation, recovery of materials and abatement techniques, finishing of the polymer (e.g. extrusion, drying, blending) as well as the transfer, handling and storage of synthetic rubbers. Grp. 123. BAT conclusions for the production of synthetic rubbers Grp. 33. BAT is to monitor channelled emissions to air with at least the frequency given below and in accordance with EN standards. If EN standards are not available, BAT is to use ISO, national or other international standards that ensure the provision of data of an equivalent scientific quality. Substance Emission points Standard(s) Minimum monitoring frequency Monitoring associated with Carbon disulphide (CS2) Any stack with a mass flow of ≥ 1 kg/h Generic EN standards Continuous BAT 35 Any stack with a mass flow of < 1 kg/h No EN standard available Once every year Hydrogen sulphide (H2S) Any stack with a mass flow of ≥ 50 g/h Generic EN standards Continuous Any stack with a mass flow of < 50 g/h No EN standard available Once every year Grp. 34. In order to increase resource efficiency and to reduce the mass flow of CS2 and H2S sent to the final waste gas treatment, BAT is to recover CS2 by using technique a. and/or technique b. or a combination of technique c. with technique(s) a. and/or b., given below and to reuse the CS2, or, alternatively, to use technique d. Technique Main substance targeted Description Applicability a. Absorption (regenerative) H2S See Section 1.4.1. Generally applicable for the production of casing. For other products, applicability may be restricted where the energy demand is excessive due to high waste gas volume flows (above e.g. 120000 Nm3/h) or low H2S concentration in the waste gas (below e.g. 0,5 g/Nm3). b. Adsorption (regenerative) H2S, CS2 See Section 1.4.1. Applicability may be restricted where the energy demand for recovery is excessive if the concentration of CS2 in the waste gas is below e.g. 5 g/Nm3. c. Condensation H2S, CS2 See Section 1.4.1. d. Production of sulphuric acid H2S, CS2 Process off-gases containing CS2 and H2S are used to produce sulphuric acid. Applicability may be restricted if the concentration of CS2 and/or H2S in the waste gas is below 5 g/Nm3. Grp_35_table. 113. In order to reduce channelled emissions to air of CS2 and H2S, BAT is to use one or a combination of the techniques given below. Technique Main substance targeted Description Applicability a. Absorption H2S See Section 1.4.1. Generally applicable. b. Bioprocesses CS2, H2S See Section 1.4.1. Applicability may be restricted where the energy demand is excessive due to high waste gas volume flows (e.g. above 60000 Nm3/h) or high CS2 concentration in the waste gas (e.g. above 1 000 mg/Nm3) or too low H2S concentration. c. Thermal oxidation CS2, H2S See Section 1.4.1. Applicability of recuperative and regenerative thermal oxidation to existing plants may be restricted by design and/or operational constraints. Applicability may be restricted where the energy demand is excessive due to the low concentration of the compound(s) concerned in the process off-gases. Substance BAT-AEL (mg/Nm3) (Daily average or average over the sampling period) CS2 5-400 H2S 1-10 The associated monitoring is given in BAT 33. Parameter Process Unit BAT-AEL (Yearly average) Sum of H2S and CS2 (expressed as Total S) Production of staple fibres g Total S per kg of product 6-9 Casing 120-250 The associated monitoring is given in BAT 33. Grp. 124. BAT conclusions for the production of viscose using CS2 Grp. 12. Polymers and synthetic rubbers The BAT conclusions presented in this section apply to the production of certain polymers. They apply in addition to the general BAT conclusions given in Section 1.1. Grp_36_table. 115. In order to prevent or, where that is not practicable, to reduce channelled emissions to air of CO, dust, NOX and SOX, BAT is to use technique c. and one or a combination of the other techniques given below. Technique Description Main inorganic compounds targeted Applicability Primary techniques a. Choice of fuel See Section 1.4.1. This includes switching from liquid to gaseous fuels, taking into account the overall hydrocarbon balance. NOX, SOX, dust The switch from liquid to gaseous fuels may be restricted by the design of the burners in the case of existing process furnaces/heaters. b. Low-NOX burner See Section 1.4.1. NOX For existing process furnaces/heaters, the applicability may be restricted by their design. c. Optimised combustion See Section 1.4.1. CO, NOX Generally applicable. Secondary techniques d. Absorption See Section 1.4.1. SOX, dust Applicability may be restricted for existing process furnaces/heaters by space availability. e. Fabric filter or absolute filter See Section 1.4.1. Dust Not applicable when only combusting gaseous fuels. f. Selective catalytic reduction (SCR) See Section 1.4.1. NOX Applicability to existing process furnaces/heaters may be restricted by space availability. g. Selective non-catalytic reduction (SNCR) See Section 1.4.1. NOX Applicability to existing process furnaces/heaters may be restricted by the temperature window (800-1100 °C) and the residence time needed for the reaction. Parameter BAT-AEL (mg/Nm3) (Daily average or average over the sampling period) Nitrogen oxides (NOX) 30-150 Carbon monoxide (CO) No BAT-AEL The associated monitoring is given in BAT 8. Grp. 13. Process furnaces/heaters The BAT conclusions presented in this section apply when process furnaces/heaters with a total rated thermal input equal to or greater than 1 MW are used in the production processes included in the scope of these BAT conclusions. They apply in addition to the general BAT conclusions given in Section 1.1. Where the waste gases of two or more separate process furnaces/heaters are, or could, in the judgement of the competent authority, be discharged through a common stack, the capacities of all individual furnaces/heaters shall be added together for the purpose of calculating the total rated thermal input. (1) Biofiltration: the waste gas stream is passed through a bed of organic material (such as peat, heather, compost, root wood, tree bark, peat, compost, softwood and different kinds of combinations) or some inert material (such as clay, activated carbon, and polyurethane), where it is biologically oxidised by naturally occurring microorganisms into carbon dioxide, water, inorganic salts and biomass. (2) Bioscrubbing: the removal of the pollutant compounds from a waste gas stream using a combination of wet scrubbing (absorption) and biodegradation under aerobic conditions. The scrubbing water contains a population of microorganisms suitable to oxidise biodegradable gaseous compounds. The absorbed pollutants are degraded in aerated sludge tanks. (3) Biotrickling: the removal of the pollutant compounds from a waste gas stream in a biological trickle-bed reactor. The pollutants are absorbed by the water phase and transported to the biofilm, where the biological transformation takes place. (4) Straight thermal oxidation: thermal oxidation without energy recovery from the combustion. (5) Recuperative thermal oxidation: thermal oxidation using the heat of the waste gases by indirect heat transfer. (6) Regenerative thermal oxidation: thermal oxidation where the incoming waste gas stream is heated when passing through a ceramic-packed bed before entering the combustion chamber. The purified hot gases exit this chamber by passing through one (or more) ceramic-packed bed(s) (cooled by an incoming waste gas stream in an earlier combustion cycle). This reheated packed bed then begins a new combustion cycle by preheating a new incoming waste gas stream. Grp. 141. Techniques to reduce channelled emissions to air Technique Description Absorption The removal of gaseous or particulate pollutants from a process off-gas or waste gas stream via mass transfer to a suitable liquid, often water or an aqueous solution. It may involve a chemical reaction (e.g. in an acid or alkaline scrubber). In the case of regenerative absorption, the compounds may be recovered from the liquid. Adsorption The removal of pollutants from a process off-gas or waste gas stream by retention on a solid surface (activated carbon is typically used as the adsorbent). Adsorption may be regenerative or non-regenerative. In non-regenerative adsorption, the spent adsorbent is not regenerated but disposed of. In the case of regenerative adsorption, the adsorbate is subsequently desorbed, e.g. with steam (often on site), for reuse or disposal and the adsorbent is reused. For continuous operation, typically more than two adsorbers are operated in parallel, one of them in desorption mode. Bioprocesses Bioprocesses include the following: Choice of fuel The use of fuel (including support/auxiliary fuel) with a low content of potential pollution-generating compounds (e.g. low sulphur, ash, nitrogen, fluorine or chlorine content in the fuel). Condensation The removal of vapours of organic and inorganic compounds from a process off-gas or waste gas stream by reducing its temperature below its dew point so that the vapours liquefy. Depending on the operating temperature range required, different cooling media are used, e.g. water or brine. In cryogenic condensation, liquid nitrogen is used as a cooling medium. Cyclone Equipment for the removal of dust from a process off-gas or waste gas stream based on imparting centrifugal forces, usually within a conical chamber. Electrostatic precipitator An electrostatic precipitator (ESP) is a particulate control device that uses electrical forces to move particles entrained within a waste gas stream onto collector plates. The entrained particles are given an electrical charge when they pass through a corona where gaseous ions flow. Electrodes in the centre of the flow lane are maintained at a high voltage and generate the electrical field that forces the particles to the collector walls. The pulsating DC voltage required is in the range of 20-100 kV. Absolute filter Absolute filters, also referred to as high-efficiency particle air (HEPA) filters or ultra-low penetration air (ULPA) filters, are constructed from glass cloth or fabrics of synthetic fibres through which gases are passed to remove particles. Absolute filters show higher efficiencies than fabric filters. The classification of HEPA and ULPA filters according to their performance is given in EN 1822-1. High-efficiency air filter (HEAF) A flat-bed filter in which aerosols combine into droplets. Highly viscous droplets remain on the filter fabric which contains the residues to be disposed of and separated into droplets, aerosols and dust. HEAFs are particularly suitable for treating highly viscous droplets. Fabric filter Fabric filters, often referred to as bag filters, are constructed from porous woven or felted fabric through which gases are passed to remove particles. The use of a fabric filter requires the selection of a fabric suitable for the characteristics of the waste gas and the maximum operating temperature. Low-NOX burner The technique (including ultra-low-NOX burner) is based on the principles of reducing peak flame temperatures. The air/fuel mixing reduces the availability of oxygen and reduces the peak flame temperature, thus retarding the conversion of fuel-bound nitrogen to NOX and the formation of thermal NOX, while maintaining high combustion efficiency. The design of ultra-low-NOX burners includes (air/)fuel staging and exhaust/flue-gas recirculation. Optimised combustion Good design of the combustion chambers, burners and associated equipment/devices is combined with optimisation of combustion conditions (e.g. the temperature and residence time in the combustion zone, efficient mixing of the fuel and combustion air) and the regular planned maintenance of the combustion system according to suppliers’ recommendations. Combustion conditions control is based on the continuous monitoring and automated control of appropriate combustion parameters (e.g. O2, CO, fuel to air ratio, and unburnt substances). Optimisation of catalytic or thermal oxidation Optimisation of design and operation of catalytic or thermal oxidation to promote the oxidation of organic compounds including PCDD/F present in the waste gases, to prevent PCDD/F and the (re)formation of their precursors, as well as to reduce the generation of pollutants such as NOX and CO. Catalytic oxidation Abatement technique which oxidises combustible compounds in a waste gas stream with air or oxygen in a catalyst bed. The catalyst enables oxidation at lower temperatures and in smaller equipment compared to thermal oxidation. The typical oxidation temperature is between 200 °C and 600 °C. For process off-gases with low VOC concentrations (e.g. < 1 g/Nm3), pre-concentration steps may be applied using adsorption (rotor or fixed bed, with activated carbon or zeolites). VOCs adsorbed in the concentrator are desorbed by using heated ambient air or heated waste gas, and the resulting volume flow with higher VOC concentration is directed to the oxidiser. Molecular sieves (smoothers), typically composed of zeolites, may be used before the concentrators or the oxidiser to level down high variations of VOC concentrations in the process off-gases. Thermal oxidation Abatement technique which oxidises combustible compounds in a waste gas stream by heating it with air or oxygen to above its auto-ignition point in a combustion chamber and maintaining it at a high temperature long enough to complete its combustion to carbon dioxide and water. The typical combustion temperature is between 800 °C and 1000 °C. Several types of thermal oxidation are operated: For process off-gases with low VOC concentrations (e.g. < 1 g/Nm3), pre-concentration steps may be applied using adsorption (rotor or fixed bed, with activated carbon or zeolites). VOCs adsorbed in the concentrator are desorbed by using heated ambient air or heated waste gas, and the resulting volume flow with higher VOC concentration is directed to the oxidiser. Molecular sieves (smoothers), typically composed of zeolites, may be used before the concentrators or the oxidiser to level down high variations of VOC concentrations in the process off-gases. Selective catalytic reduction (SCR) Selective reduction of nitrogen oxides with ammonia or urea in the presence of a catalyst. The technique is based on the reduction of NOX to nitrogen in a catalytic bed by reaction with ammonia at an optimum operating temperature that is typically around 200– 450 °C. In general, ammonia is injected as an aqueous solution; the ammonia source can also be anhydrous ammonia or a urea solution. Several layers of catalyst may be applied. A higher NOX reduction is achieved with the use of a larger catalyst surface, installed as one or more layers. In-duct or slip SCR combines SNCR with downstream SCR which reduces the ammonia slip from SNCR. Selective non-catalytic reduction (SNCR) Selective reduction of nitrogen oxides to nitrogen with ammonia or urea at high temperatures and without catalyst. The operating temperature window is maintained between 800 °C and 1000 °C for optimal reaction. Grp. 142. Techniques to monitor diffuse emissions to air Technique Description Differential absorption LIDAR (DIAL) A laser-based technique using differential absorption LIDAR (light detection and ranging), which is the optical analogue of radio-wave-based RADAR. The technique relies on the back-scattering of laser beam pulses by atmospheric aerosols, and the analysis of the spectral properties of the returned light collected with a telescope. Emission factor Emission factors are numbers that can be multiplied by an activity rate (e.g. the production output), in order to estimate the emissions from the installation. Emission factors are generally derived through the testing of a population of similar process equipment or process steps. This information can be used to relate the quantity of material emitted to some general measure of the scale of activity. In the absence of other information, default emission factors (e.g. literature values) can be used to provide an estimate of the emissions. Emission factors are usually expressed as the mass of a substance emitted divided by the throughput of the process emitting the substance. Leak Detection and Repair (LDAR) programme A structured approach to reduce fugitive VOC emissions by detection and subsequent repair or replacement of leaking components. The LDAR programme consists of one or more campaigns. A campaign is usually conducted over 1 year, where a certain percentage of the pieces of equipment is monitored. Optical gas imaging (OGI) methods Optical gas imaging uses small lightweight hand-held or fixed cameras which enable the visualisation of gas leaks in real time, so that they appear as smoke on a video recorder together with the image of the equipment concerned, to easily and rapidly locate significant VOC leaks. Active systems produce an image with a back-scattered infrared laser light reflected on the equipment and its surroundings. Passive systems are based on the natural infrared radiation of the equipment and its surroundings. Solar occultation flux (SOF) The technique is based on the recording and spectrometric Fourier Transform analysis of a broadband infrared or ultraviolet/visible sunlight spectrum along a given geographical itinerary, crossing the wind direction and cutting through VOC plumes. Grp. 143. Techniques to reduce diffuse emissions Technique Description Devolatilisation extrusion When the concentrated rubber solution is further processed by extrusion, the solvent vapours (commonly cyclohexane, hexane, heptane, toluene, cyclopentane, isopentane or mixtures thereof) coming from the vent hole of the extruder are compressed and sent to recovery. Stripping VOCs contained in the polymer are transferred to the gaseous phase (e.g. by using steam). The removal efficiency may be optimised by a suitable combination of temperature, pressure and residence time and by maximising the ratio of free polymer surface to total polymer volume. Vapour balancing The vapour from a piece of receiving equipment (e.g. a tank) that is displaced during the transfer of a liquid and is returned to the delivery equipment from which the liquid is delivered. Grp. 14. Description of techniques Grp. 1. Best Available Techniques (BAT) conclusions for Common Waste Gas Management and Treatment Systems in the Chemical Sector
ANNEX
1. Best Available Techniques (BAT) conclusions for Common Waste Gas Management and Treatment Systems in the Chemical Sector (1) Emissions to air from the production of chlorine, hydrogen, and sodium/potassium hydroxide by the electrolysis of brine. This is covered by the BAT conclusions for the Production of Chlor-alkali (CAK). (1) lower olefins using the steam cracking process; (2) formaldehyde; (3) ethylene oxide and ethylene glycols; (4) phenol from cumene; (5) dinitrotoluene from toluene, toluene diamine from dinitrotoluene, toluene diisocyanate from toluene diamine, methylene diphenyl diamine from aniline, methylene diphenyl diisocyanate from methylene diphenyl diamine; (6) ethylene dichloride (EDC) and vinyl chloride monomer (VCM); (7) hydrogen peroxide. (2) Channelled emissions to air from the production of the following chemicals in continuous processes where the total production capacity of those chemicals exceeds 20 kt/yr: This is covered by the BAT conclusions for the Production of Large Volume Organic Chemicals (LVOC). However, channelled emissions to air of nitrogen oxides (NOX) and carbon monoxide (CO) from thermal treatment of waste gases originating from the aforementioned production processes are included in the scope of these BAT conclusions. (1) ammonia; (2) ammonium nitrate; (3) calcium ammonium nitrate; (4) calcium carbide; (5) calcium chloride; (6) calcium nitrate; (7) carbon black; (8) ferrous chloride; (9) ferrous sulphate (i.e. copperas and related products, such as chloro-sulphates); (10) hydrofluoric acid; (11) inorganic phosphates; (12) nitric acid; (13) nitrogen-, phosphorus- or potassium-based fertilisers (simple or compound fertilisers); (14) phosphoric acid; (15) precipitated calcium carbonate; (16) sodium carbonate (i.e. soda ash); (17) sodium chlorate; (18) sodium silicate; (19) sulphuric acid; (20) synthetic amorphous silica; (21) titanium dioxide and related products; (22) urea; (23) urea-ammonium nitrate. (3) Emissions to air from the production of the following inorganic chemicals: This may be covered by the BAT conclusions for the Production of Large Volume Inorganic Chemicals (LVIC). (4) Emissions to air from steam reforming as well as from the physical purification and reconcentration of spent sulphuric acid, provided that these processes are directly associated with a production process listed under the aforementioned points 2 or 3. (5) Emissions to air from the production of magnesium oxide using the dry process route. This may be covered by the BAT conclusions for the Production of Cement, Lime and Magnesium Oxide (CLM). (1) Combustion units other than process furnaces/heaters. This may be covered by the BAT conclusions for Large Combustion Plants (LCP), the BAT conclusions for the Refining of Mineral Oil and Gas (REF) and/or by Directive (EU) 2015/2193 of the European Parliament and of the Council. (2) Process furnaces/heaters with a total rated thermal input below 1 MW. (3) Process furnaces/heaters used in lower olefins, ethylene dichloride and/or vinyl chloride monomer production referred to in point 2 above. This is covered by the BAT conclusions for the production of Large Volume Organic Chemicals (LVOC). (6) Emissions to air from the following: (7) Emissions to air from waste incineration plants. This may be covered by the BAT conclusions for Waste Incineration (WI). (8) Emissions to air from the storage, transfer and handling of liquids, liquefied gases and solids, where these are not directly associated with the activity specified in Annex I to Directive 2010/75/EU: 4. Chemical industry. This may be covered by the BAT conclusions for Emissions from Storage (EFS). However, emissions to air from the storage, transfer and handling of liquids, liquefied gases and solids are included in the scope of these BAT conclusions provided that these processes are directly associated with the chemical production process specified in the scope of these BAT conclusions. (9) Emissions to air from indirect cooling systems. This may be covered by the BAT conclusions for Industrial Cooling Systems (ICS). (10) Production of Chlor-alkali (CAK); (11) Manufacture of Large Volume Inorganic Chemicals – Ammonia, Acids and Fertilisers (LVIC-AAF); (12) Manufacture of Large Volume Inorganic Chemicals – Solids and Others Industry (LVIC-S); (13) Production of Large Volume Organic Chemicals (LVOC); (14) Manufacture of Organic Fine Chemicals (OFC); (15) Production of Polymers (POL); (16) Production of Speciality Inorganic Chemicals (SIC); (17) Refining of Mineral Oil and Gas (REF); (18) Economics and Cross-media Effects (ECM); (19) Emissions from Storage (EFS); (20) Energy Efficiency (ENE); (21) Industrial Cooling Systems (ICS); (22) Large Combustion Plants (LCP); (23) Monitoring of Emissions to Air and Water from IED installations (ROM); (24) Waste Incineration (WI); (25) Waste Treatment (WT). Grp. scope. These BAT conclusions concern the following activity specified in Annex I to Directive 2010/75/EU: 4. Chemical industry (i.e. all production processes included in the categories of activities listed in points 4.1 to 4.6 of Annex I, unless specified otherwise). More specifically, these BAT conclusions focus on emissions to air from the aforementioned activity. These BAT conclusions do not address the following: Other BAT conclusions which are complementary for the activities covered by these BAT conclusions include Common Waste Water and Waste Gas Treatment/Management Systems in the Chemical Sector (CWW). Other BAT conclusions and reference documents which could be relevant for the activities covered by these BAT conclusions are the following: These BAT conclusions apply without prejudice to other relevant legislation, e.g. on the registration, evaluation, authorisation and restriction of chemicals (REACH) or on classification, labelling and packaging of substances and mixtures (CLP). (1) moving equipment, such as agitators, compressors, pumps, valves (manual and automatic); (2) static equipment, such as flanges and other connections, open-ended lines, sampling points. (3) substances used (e.g. substances that cannot be substituted, very corrosive substances); (4) operating conditions (e.g. very high temperature or pressure); (5) the functioning of the plant; (6) resource availability (e.g. availability of spare parts when replacing a piece of equipment, availability of qualified manpower); (7) expected environmental benefits (e.g. giving priority to maintenance, repair or replacement actions with the highest environmental benefit). (8) combustion units used for the treatment of objects or feed material through direct contact, e.g. in drying processes or chemical reactors; or (9) combustion units whose radiant and/or conductive heat is transferred to objects or feed material through a solid wall without using an intermediary heat transfer fluid, e.g. furnaces or reactors heating a process stream used in the (petro-)chemical industry. Grp. definitions. For the purposes of these BAT conclusions, the following definitions apply: General terms Term used Definition Channelled emissions to air Emissions of pollutants to air through an emission point such as a stack. Combustion unit Any technical apparatus in which fuels are oxidised in order to use the heat thus generated. Combustion units include boilers, engines, turbines and process furnaces/heaters, but do not include thermal or catalytic oxidisers. Complex inorganic pigments A stable crystal lattice of different metal cations. The most important host-lattices are rutile, spinel, zircon, and haematite/corundum, but other stable structures exist. Continuous measurement Measurement using an automated measuring system permanently installed on site. Continuous process A process in which the raw materials are fed continuously into the reactor with the reaction products then fed into connected downstream separation and/or recovery units. Diffuse emissions Non-channelled emissions to air. Diffuse emissions include fugitive and non-fugitive emissions. Emissions to air Generic term for emissions of pollutants to air including both channelled and diffuse emissions. Ethanolamines Collective term for monoethanolamine, diethanolamine and triethanolamine, or mixtures thereof. Ethylene glycols Collective term for monoethylene glycol, diethylene glycol and triethylene glycol, or mixtures thereof. Existing plant A plant that is not a new plant. Existing process furnace/heater A process furnace/heater that is not a new process furnace/heater. Flue-gas The exhaust gas exiting a combustion unit. Fugitive emissions Non-channelled emissions to air caused by loss of tightness of equipment which is designed or assembled to be tight. Fugitive emissions can arise from: Lower olefins Collective term for ethylene, propylene, butylene and butadiene, or mixtures thereof. Major plant upgrade A major change in the design or technology of a plant with major adjustments or replacements of the process and/or abatement units and associated equipment. Mass flow The mass of a given substance or parameter which is emitted over a defined period of time. New plant A plant first permitted on the site of the installation following the publication of these BAT conclusions or a complete replacement of a plant following the publication of these BAT conclusions. New process furnace/heater A process furnace/heater in a plant first permitted following the publication of these BAT conclusions or a complete replacement of a process furnace/heater following the publication of these BAT conclusions. Non-fugitive emissions Diffuse emissions other than fugitive emissions. Non-fugitive emissions may arise from, for example, atmospheric vents, bulk storage, loading/unloading systems, vessels and tanks (on opening), open gutters, sampling systems, tank venting, waste, sewers and water treatment plants. NOX precursors Nitrogen-containing compounds (e.g. acrylonitrile, ammonia, nitrous gases, nitrogen-containing organic compounds) in the input to thermal or catalytic oxidation that lead to NOX emissions. Elemental nitrogen is not included. Operational constraint Limitation or restriction connected, for example, to: Periodic measurement Measurement at specified time intervals using manual or automated methods. Polymer grade For each type of polymer, there are different product qualities (i.e. grades) which vary in structure and molecular mass, and are optimised for specific applications. In the case of polyolefins, these may vary regarding the use of co-polymers such as EVA. In the case of PVC, they may vary in the average length of the polymer chain and in the porosity of the particles. Process furnace/heater Process furnaces or heaters are: As a consequence of the application of good energy recovery practices, some of the process furnaces/heaters may have an associated steam/electricity generation system. This is an integral design feature of the process furnace/heater that cannot be considered in isolation. Process off-gas The gas leaving a process which is further treated for recovery and/or abatement. Solvent Organic solvent as defined in Article 3(46) of Directive 2010/75/EU. Solvent consumption Consumption of solvent as defined in Article 57(9) of Directive 2010/75/EU. Solvent input The total quantity of organic solvents used as defined in Part 7 of Annex VII to Directive 2010/75/EU. Solvent mass balance A mass balance exercise conducted at least on an annual basis according to Part 7 of Annex VII to Directive 2010/75/EU. Thermal treatment Treatment of waste gases using thermal or catalytic oxidation. Total emissions The sum of channelled and diffuse emissions. Valid hourly (or half-hourly) average An hourly (or half-hourly) average is considered valid when there is no maintenance or malfunction of the automated measuring system. Substances/Parameters Term used Definition Cl2 Elemental chlorine. CO Carbon monoxide. CS2 Carbon disulphide. Dust Total particulate matter (in air). Unless specified otherwise, dust includes PM2,5 and PM10. EDC Ethylene dichloride (1,2-Dichloroethane). HCl Hydrogen chloride. HCN Hydrogen cyanide. HF Hydrogen fluoride. H2S Hydrogen sulphide. NH3 Ammonia. Ni Nickel. N2O Dinitrogen oxide (also referred to as nitrous oxide). NOX The sum of nitrogen monoxide (NO) and nitrogen dioxide (NO2), expressed as NO2. Pb Lead. PCDD/F Polychlorinated dibenzo-p-dioxins and -furans. PM2,5 Particulate matter which passes through a size-selective inlet with a 50 % efficiency cut-off at 2,5 μm aerodynamic diameter as defined in Directive 2008/50/EC of the European Parliament and of the Council. PM10 Particulate matter which passes through a size-selective inlet with a 50 % efficiency cut-off at 10 μm aerodynamic diameter as defined in Directive 2008/50/EC. SO2 Sulphur dioxide. SOX The sum of sulphur dioxide (SO2), sulphur trioxide (SO3), and sulphuric acid aerosols, expressed as SO2. TVOC Total volatile organic carbon, expressed as C. VCM Vinyl chloride monomer. VOC Volatile organic compound as defined in Article 3(45) of Directive 2010/75/EU. Grp. acronyms. For the purposes of these BAT conclusions, the following acronyms apply: Acronym Definition CLP Regulation (EC) No 1272/2008 of the European Parliament and of the Council on classification, labelling and packaging of substances and mixtures. CMR Carcinogenic, mutagenic or toxic for reproduction. CMR 1A CMR substance of category 1A as defined in Regulation (EC) No 1272/2008 as amended, i.e. carrying the hazard statements H340, H350, H360. CMR 1B CMR substance of category 1B as defined in Regulation (EC) No 1272/2008 as amended, i.e. carrying the hazard statements H340, H350, H360. CMR 2 CMR substance of category 2 as defined in Regulation (EC) No 1272/2008 as amended, i.e. carrying the hazard statements H341, H351, H361. DIAL Differential absorption LIDAR. EMS Environmental Management System. EPS Expandable polystyrene. E-PVC PVC produced by emulsion polymerisation. EVA Ethylene-vinyl acetate. GPPS General-purpose polystyrene. HDPE High-density polyethylene. HEAF High-efficiency air filter. HEPA High-efficiency particle air. HIPS High-impact polystyrene. IED Directive 2010/75/EU on industrial emissions. I-TEQ International toxic equivalent – derived by using the equivalence factors in Part 2 of Annex VI to Directive 2010/75/EU. LDAR Leak detection and repair. LDPE Low-density polyethylene. LIDAR Light detection and ranging. LLDPE Linear low-density polyethylene. OGI Optical gas imaging. OTNOC Other than normal operating conditions. PP Polypropylene. PVC Polyvinyl chloride. REACH Regulation (EC) No 1907/2006 of the European Parliament and of the Council concerning the registration, evaluation, authorisation and restriction of chemicals. SCR Selective catalytic reduction. SNCR Selective non-catalytic reduction. SOF Solar occultation flux. S-PVC PVC produced by suspension polymerisation. ULPA Ultra-low penetration air. Grp_available. techniques. The techniques listed and described in these BAT conclusions are neither prescriptive nor exhaustive. Other techniques may be used that ensure at least an equivalent level of environmental protection. Unless otherwise stated, the BAT conclusions are generally applicable. Grp_levels_associated_with_the_best_available_techniques_bataels_and_indicative_emission_levels_for_channelled_emissions_to. air. The BAT-AELs and the indicative emission levels for channelled emissions to air given in these BAT conclusions refer to values of concentration, expressed as mass of emitted substance per volume of waste gas under standard conditions (dry gas at a temperature of 273,15 K, and a pressure of 101,3 kPa) and expressed in the unit mg/Nm3, μg/Nm3 or ng I-TEQ/Nm3. The reference oxygen levels used to express BAT-AELs and indicative emission levels in these BAT conclusions are shown in the table below. Source of emissions Reference oxygen level (OR) Process furnace/heater using indirect heating 3 dry vol-% All other sources No correction for the oxygen level For the cases where a reference oxygen level is given, the equation for calculating the emission concentration at the reference oxygen level is: ER21OR21OMEM where: ER emission concentration at the reference oxygen level OR; OR reference oxygen level in vol-%; EM measured emission concentration; OM measured oxygen level in vol-%. The equation above does not apply if the process furnace(s)/heater(s) use(s) oxygen-enriched air or pure oxygen or when additional air intake for safety reasons brings the oxygen level in the waste gas very close to 21 vol-%. In this case, the emission concentration at the reference oxygen level of 3 dry vol-% is calculated differently. For averaging periods of BAT-AELs and indicative emission levels for channelled emissions to air, the following definitions apply. Type of measurement Averaging period Definition Continuous Daily average Average over a period of 1 day based on valid hourly or half-hourly averages. Periodic Average over the sampling period Average value of three consecutive samplings/measurements of at least 30 minutes each. For the purpose of calculating the mass flows in relation to BAT 11 (Table 1.1), BAT 14 (Table 1.3), BAT 18 (Table 1.6), BAT 29 (Table 1.9) and BAT 36 (Table 1.15), where waste gases with similar characteristics, e.g. containing the same (type of) substances/parameters, and discharged through two or more separate stacks could, in the judgement of the competent authority, be discharged through a common stack, these stacks shall be considered as a single stack. Grp_for_diffuse_voc_emissions_to. air. For diffuse VOC emissions from the use of solvents or the reuse of recovered solvents, the BAT-AELs in these BAT conclusions are given as a percentage of the solvent input, calculated on an annual basis according to Part 7 of Annex VII to Directive 2010/75/EU. Grp_of_polyolefins_or_synthetic. rubbers. For total emissions to air of VOCs from the production of polyolefins or synthetic rubbers, the BAT-AELs in these BAT conclusions are given as specific emission loads calculated on an annual basis by dividing the total VOC emissions by a sector-dependent production rate, expressed in the unit g C/kg of product. Grp_of. pvc. For total emissions to air of VCM from the production of PVC, the BAT-AELs in these BAT conclusions are given as specific emission loads calculated on an annual basis by dividing the total VCM emissions by a sector-dependent production rate, expressed in the unit g/kg of product. For the purpose of calculating specific emission loads, total emissions include the VCM concentration in the PVC. Grp_of. viscose. For the production of viscose, the BAT-AEL in these BAT conclusions is given as a specific emission load calculated on an annual basis by dividing the total S emissions by the production rate of staple fibres or casing, expressed in the unit g S/kg of product. (i) commitment, leadership, and accountability of the management, including senior management, for the implementation of an effective EMS; (ii) an analysis that includes the determination of the organisation’s context, the identification of the needs and expectations of interested parties, the identification of characteristics of the installation that are associated with possible risks for the environment (or human health) as well as of the applicable legal requirements relating to the environment; (iii) development of an environmental policy that includes the continuous improvement of the environmental performance of the installation; (iv) establishing objectives and performance indicators in relation to significant environmental aspects, including safeguarding compliance with applicable legal requirements; (v) planning and implementing the necessary procedures and actions (including corrective and preventive actions where needed), to achieve the environmental objectives and avoid environmental risks; (vi) determination of structures, roles and responsibilities in relation to environmental aspects and objectives and provision of the financial and human resources needed; (vii) ensuring the necessary competence and awareness of staff whose work may affect the environmental performance of the installation (e.g. by providing information and training); (viii) internal and external communication; (ix) fostering employee involvement in good environmental management practices; (x) establishing and maintaining a management manual and written procedures to control activities with significant environmental impact as well as relevant records; (xi) effective operational planning and process control; (xii) implementation of appropriate maintenance programmes; (xiii) emergency preparedness and response protocols, including the prevention and/or mitigation of the adverse (environmental) impacts of emergency situations; (xiv) when (re)designing a (new) installation or a part thereof, consideration of its environmental impacts throughout its life, which includes construction, maintenance, operation and decommissioning; (xv) implementation of a monitoring and measurement programme; if necessary, information can be found in the Reference Report on Monitoring of Emissions to Air and Water from IED Installations; (xvi) application of sectoral benchmarking on a regular basis; (xvii) periodic independent (as far as practicable) internal auditing and periodic independent external auditing in order to assess the environmental performance and to determine whether or not the EMS conforms to planned arrangements and has been properly implemented and maintained; (xviii) evaluation of causes of nonconformities, implementation of corrective actions in response to nonconformities, review of the effectiveness of corrective actions, and determination of whether similar nonconformities exist or could potentially occur; (xix) periodic review, by senior management, of the EMS and its continuing suitability, adequacy and effectiveness; (xx) following and taking into account the development of cleaner techniques. (xxi) an inventory of channelled and diffuse emissions to air (see BAT 2); (xxii) an OTNOC management plan for emissions to air (see BAT 3); (xxiii) an integrated waste gas management and treatment strategy for channelled emissions to air (see BAT 4); (xxiv) a management system for diffuse VOC emissions to air (see BAT 19); (xxv) a chemicals management system that includes an inventory of the hazardous substances and substances of very high concern used in the process(es); the potential for substitution of the substances that are listed in this inventory, focusing on those substances other than raw materials, is analysed periodically (e.g. annually) in order to identify possible new available and safer alternatives, with no or lower environmental impacts. Grp. note. Regulation (EC) No 1221/2009 of the European Parliament and of the Council establishes the European Union eco-management and audit scheme (EMAS), which is an example of an EMS consistent with this BAT. Grp. applicability. The level of detail and the degree of formalisation of the EMS will generally be related to the nature, scale and complexity of the installation, and the range of environmental impacts it may have. Grp. 1. In order to improve the overall environmental performance, BAT is to elaborate and implement an environmental management system (EMS) that incorporates all of the following features: Specifically for the chemical sector, BAT is also to incorporate the following features in the EMS: (a) chemical reaction equations, also showing side products; (b) simplified process flow sheets that show the origin of the emissions; (i) information, as comprehensive as is reasonably possible, about the chemical production process(es), including: (a) emission point(s); (b) average values and variability of flow and temperature; (c) average concentration and mass flow values of relevant substances/parameters and their variability (e.g. TVOC, CO, NOX, SOX, Cl2, HCl); (d) presence of other substances that may affect the waste gas treatment system(s) or plant safety (e.g. oxygen, nitrogen, water vapour, dust); (e) techniques used to prevent and/or reduce channelled emissions to air; (f) flammability, lower and higher explosive limits, reactivity; (g) monitoring methods (see BAT 8); (h) presence of substances classified as CMR 1A, CMR 1B or CMR 2; the presence of such substances may for example be assessed according to the criteria of Regulation (EC) No 1272/2008 on classification, labelling and packaging (CLP). (ii) information, as comprehensive as is reasonably possible, about channelled emissions to air, such as: (a) identification of the emission source(s); (b) characteristics of each emission source (e.g. fugitive or non-fugitive; static or moving; accessibility of the emission source; included in an LDAR programme or not); (1) physical state; (2) vapour pressure of the substance(s) in the liquid, pressure of the gas; (3) temperature; (4) composition (by weight for liquids or by volume for gases); (5) hazardous properties of the substance(s) or mixtures, including substances or mixtures classified as CMR 1A, CMR 1B or CMR 2; (c) the characteristics of the gas or liquid in contact with the emission source(s), including: (d) techniques used to prevent and/or reduce diffuse emissions to air; (e) monitoring (see BAT 20, BAT 21 and BAT 22). (iii) information, as comprehensive as is reasonably possible, about diffuse emissions to air, such as: Grp_for_diffuse. emissions. The information about diffuse emissions to air is particularly relevant for activities using large amounts of organic substances or mixtures (e.g. production of pharmaceuticals, production of large volumes of organic chemicals or of polymers). The information about fugitive emissions covers all emission sources in contact with organic substances with a vapour pressure greater than 0,3 kPa at 293,15 K. Sources of fugitive emissions connected to pipes whose diameter is small (e.g. smaller than 12,7 mm, i.e. 0,5 inch) may be excluded from the inventory. Equipment operated under subatmospheric pressure may be excluded from the inventory. Grp. applicability. The level of detail and the degree of formalisation of the inventory will generally be related to the nature, scale and complexity of the installation, and the range of environmental impacts it may have. Grp. 2. In order to facilitate the reduction of emissions to air, BAT is to establish, maintain and regularly review (including when a substantial change occurs) an inventory of channelled and diffuse emissions to air, as part of the environmental management system (see BAT 1), that incorporates all of the following features: Grp. 111. Environmental management systems (i) identification of potential OTNOC (e.g. failure of equipment critical to the control of channelled emissions to air, or equipment critical to the prevention of accidents or incidents that could lead to emissions to air (critical equipment)), of their root causes and of their potential consequences; (ii) appropriate design of critical equipment (e.g. equipment modularity and compartmentalisation, backup systems, techniques to obviate the need to bypass waste gas treatment during start-up and shutdown, high-integrity equipment, etc.); (iii) set-up and implementation of a preventive maintenance plan for critical equipment (see BAT 1 xii.); (iv) monitoring (i.e. estimating or, where this is possible, measuring) and recording of emissions and associated circumstances during OTNOC; (v) periodic assessment of the emissions occurring during OTNOC (e.g. frequency of events, duration, amount of pollutants emitted as recorded in point iv.) and implementation of corrective actions if necessary; (vi) regular review and update of the list of identified OTNOC under point i. following the periodic assessment of point v.; (vii) regular testing of backup systems. Grp. 3. In order to reduce the frequency of the occurrence of OTNOC and to reduce emissions to air during OTNOC, BAT is to set up and implement a risk-based OTNOC management plan as part of the environmental management system (see BAT 1) that includes all of the following features: Grp. 112. Other than normal operating conditions (OTNOC) Grp. description. The integrated waste gas management and treatment strategy is based on the inventory in BAT 2. It takes into account factors such as greenhouse gas emissions and the consumption or reuse of energy, water and materials associated with the use of the different techniques. Grp. 4. In order to reduce channelled emissions to air, BAT is to use an integrated waste gas management and treatment strategy that includes, in order of priority, process-integrated recovery and abatement techniques. Grp. description. The combined treatment of waste gases with similar characteristics ensures more effective and efficient treatment compared to the separate treatment of individual waste gas streams. The combination of waste gases is carried out considering plant safety (e.g. avoiding concentrations close to the lower/upper explosive limit), technical (e.g. compatibility of the individual waste gas streams, concentration of the substances concerned), environmental (e.g. maximising recovery of materials or pollutant abatement) and economic factors (e.g. distance between different production units). Care is taken that the combination of waste gases does not lead to the dilution of emissions. Grp. 5. In order to facilitate the recovery of materials and the reduction of channelled emissions to air, as well as to increase energy efficiency, BAT is to combine waste gas streams with similar characteristics, thus minimising the number of emission points. Grp. 6. In order to reduce channelled emissions to air, BAT is to ensure that the waste gas treatment systems are appropriately designed (e.g. considering the maximum flow rate and pollutant concentrations), operated within their design ranges, and maintained (through preventive, corrective, regular and unplanned maintenance) so as to ensure optimal availability, effectiveness and efficiency of the equipment. Grp. 1131. General techniques Grp. 7. BAT is to continuously monitor key process parameters (e.g. waste gas flow and temperature) of waste gas streams being sent to pretreatment and/or final treatment. Grp. 8. BAT is to monitor channelled emissions to air with at least the frequency given below and in accordance with EN standards. If EN standards are not available, BAT is to use ISO, national or other international standards that ensure the provision of data of an equivalent scientific quality. Substance/Parameter Process(es)/Source(s) Emission points Standard(s) Minimum monitoring frequency Monitoring associated with Ammonia (NH3) Use of SCR/SNCR Any stack EN 21877 Once every 6 months BAT 17 All other processes/sources BAT 18 Benzene All processes/sources Any stack No EN standard available Once every 6 months BAT 11 1,3-Butadiene All processes/sources Any stack No EN standard available Once every 6 months BAT 11 Carbon monoxide (CO) Thermal treatment Any stack with a CO mass flow of ≥ 2 kg/h Generic EN standards Continuous BAT 16 Any stack with a CO mass flow of < 2 kg/h EN 15058 Once every 6 months Process furnaces/heaters Any stack with a CO mass flow of ≥ 2 kg/h Generic EN standards Continuous BAT 36 Any stack with a CO mass flow of < 2 kg/h EN 15058 Once every 6 months All other processes/sources Any stack with a CO mass flow of ≥ 2 kg/h Generic EN standards Continuous BAT 18 Any stack with a CO mass flow of < 2 kg/h EN 15058 Once every year Chloromethane All processes/sources Any stack No EN standard available Once every 6 months BAT 11 CMR substances other than CMR substances covered elsewhere in this table All other processes/sources Any stack No EN standard available Once every 6 months BAT 11 Dichloromethane All processes/sources Any stack No EN standard available Once every 6 months BAT 11 Dust All processes/sources Any stack with dust mass flow ≥ 3 kg/h Generic EN standards, EN 13284-1 and EN 13284-2 Continuous BAT 14 Any stack with dust mass flow < 3 kg/h EN 13284-1 Once every year Elemental chlorine (Cl2) All processes/sources Any stack No EN standard available Once every year BAT 18 Ethylene dichloride (EDC) All processes/sources Any stack No EN standard available Once every 6 months BAT 11 Ethylene oxide All processes/sources Any stack No EN standard available Once every 6 months BAT 11 Formaldehyde All processes/sources Any stack EN standard under development Once every 6 months BAT 11 Gaseous chlorides All processes/sources Any stack EN 1911 Once every year BAT 18 Gaseous fluorides All processes/sources Any stack No EN standard available Once every year BAT 18 Hydrogen cyanide (HCN) All processes/sources Any stack No EN standard available Once every year BAT 18 Lead and its compounds All processes/sources Any stack EN 14385 Once every 6 months BAT 14 Nickel and its compounds All processes/sources Any stack EN 14385 Once every 6 months BAT 14 Nitrous oxide (N2O) All processes/sources Any stack EN ISO 21258 Once every year – Nitrogen oxides (NOX) Thermal treatment Any stack with a NOX mass flow of ≥ 2,5 kg/h Generic EN standards Continuous BAT 16 Any stack with a NOX mass flow of < 2,5 kg/h EN 14792 Once every 6 months Process furnaces/heaters Any stack with a NOX mass flow of ≥ 2,5 kg/h Generic EN standards Continuous BAT 36 Any stack with a NOX mass flow of < 2,5 kg/h EN 14792 Once every 6 months All other processes/sources Any stack with a NOX mass flow of ≥ 2,5 kg/h Generic EN standards Continuous BAT 18 Any stack with a NOX mass flow of < 2,5 kg/h EN 14792 Once every 6 months PCDD/F Thermal treatment Any stack EN 1948-1, EN 1948-2, EN 1948-3 Once every 6 months BAT 12 PM2,5 and PM10 All processes/sources Any stack EN ISO 23210 Once every year BAT 14 Propylene oxide All processes/sources Any stack No EN standard available Once every 6 months BAT 11 Sulphur dioxide (SO2) Thermal treatment Any stack with a SO2 mass flow of ≥ 2,5 kg/h Generic EN standards Continuous BAT 16 Any stack with a SO2 mass flow of < 2,5 kg/h EN 14791 Once every 6 months Process furnaces/heaters Any stack with a SO2 mass flow of ≥ 2,5 kg/h Generic EN standards Continuous BAT 18, BAT 36 Any stack with a SO2 mass flow of < 2,5 kg/h EN 14791 Once every 6 months All other processes/sources Any stack with a SO2 mass flow of ≥ 2,5 kg/h Generic EN standards Continuous BAT 18 Any stack with a SO2 mass flow of < 2,5 kg/h EN 14791 Once every 6 months Tetrachloromethane All processes/sources Any stack No EN standard available Once every 6 months BAT 11 Toluene All processes/sources Any stack No EN standard available Once every 6 months BAT 11 Trichloromethane All processes/sources Any stack No EN standard available Once every 6 months BAT 11 Total volatile organic carbon (TVOC) Production of polyolefins Any stack with a TVOC mass flow of ≥ 2 kg C/h Generic EN standards Continuous BAT 11, BAT 25 Any stack with a TVOC mass flow of < 2 kg C/h EN 12619 Once every 6 months Production of synthetic rubbers Any stack with a TVOC mass flow of ≥ 2 kg C/h Generic EN standards Continuous BAT 11, BAT 32 Any stack with a TVOC mass flow of < 2 kg C/h EN 12619 Once every 6 months All other processes/sources Any stack with a TVOC mass flow of ≥ 2 kg C/h Generic EN standards Continuous BAT 11 Any stack with a TVOC mass flow of < 2 kg C/h EN 12619 Once every 6 months Grp. 1132. Monitoring Grp. applicability. Recovery may be restricted where the energy demand is excessive due to the low concentration of the compound(s) concerned in the process off-gas(es). Reuse may be restricted due to product quality specifications. Grp. 9. In order to increase resource efficiency and to reduce the mass flow of organic compounds sent to the final waste gas treatment, BAT is to recover organic compounds from process off-gases by using one or a combination of the techniques given below and to reuse them. Technique Description a. Absorption (regenerative) See Section 1.4.1. b. Adsorption (regenerative) See Section 1.4.1. c. Condensation See Section 1.4.1. Grp. description. Process off-gases with a high calorific value are burnt as a fuel in a combustion unit (gas engine, boiler, process heater or furnace) and the heat is recovered as steam or for electricity generation, or to provide heat to the process. For process off-gases with low VOC concentrations (e.g. < 1 g/Nm3), pre-concentration steps may be applied using adsorption (rotor or fixed bed, with activated carbon or zeolites), in order to increase the calorific value of the process off-gases. Molecular sieves (smoothers), typically composed of zeolites, may be used to level down high variations (e.g. concentration peaks) of VOC concentrations in the process off-gases. Grp. applicability. Sending process off-gases to a combustion unit may be restricted due to the presence of contaminants or due to safety considerations. Grp. 10. In order to increase energy efficiency and to reduce the mass flow of organic compounds sent to the final waste gas treatment, BAT is to send process off-gases with a sufficient calorific value to a combustion unit that is, if technically possible, combined with heat recovery. BAT 9 has priority over sending process off-gases to a combustion unit. Grp_11_table. 11. In order to reduce channelled emissions to air of organic compounds, BAT is to use one or a combination of the techniques given below. Technique Description Applicability a. Adsorption See Section 1.4.1. Generally applicable. b. Absorption See Section 1.4.1. Generally applicable. c. Catalytic oxidation See Section 1.4.1. Applicability may be restricted by the presence of catalyst poisons in the waste gases. d. Condensation See Section 1.4.1. Generally applicable. e. Thermal oxidation See Section 1.4.1. Applicability of recuperative and regenerative thermal oxidation to existing plants may be restricted by design and/or operational constraints. Applicability may be restricted where the energy demand is excessive due to the low concentration of the compound(s) concerned in the process off-gases. f. Bioprocesses See Section 1.4.1. Only applicable to the treatment of biodegradable compounds. Substance/Parameter BAT-AEL (mg/Nm3) (Daily average or average over the sampling period) Total volatile organic carbon (TVOC) < 1-20 Sum of VOCs classified as CMR 1A or 1B < 1-5 Sum of VOCs classified as CMR 2 < 1-10 Benzene < 0,5-1 1,3-Butadiene < 0,5-1 Ethylene dichloride < 0,5-1 Ethylene oxide < 0,5-1 Propylene oxide < 0,5-1 Formaldehyde 1-5 Chloromethane < 0,5-1 Dichloromethane < 0,5-1 Tetrachloromethane < 0,5-1 Toluene < 0,5-1 Trichloromethane < 0,5-1 The associated monitoring is given in BAT 8. Grp_12_table. 12. In order to reduce channelled emissions to air of PCDD/F from thermal treatment of waste gases containing chlorine and/or chlorinated compounds, BAT is to use techniques a. and b., and one or a combination of techniques c. to e., given below. Technique Description Applicability Specific techniques to reduce PCDD/F emissions a. Optimised catalytic or thermal oxidation See Section 1.4.1. Generally applicable. b. Rapid waste-gas cooling Rapid cooling of waste gases from temperatures above 400 °C to below 250 °C to prevent the de novo synthesis of PCDD/F. Generally applicable. c. Adsorption using activated carbon See Section 1.4.1. Generally applicable. d. Absorption See Section 1.4.1. Generally applicable. Other techniques not primarily used to reduce PCDD/F emissions e. Selective catalytic reduction (SCR) See Section 1.4.1. When SCR is used for NOX abatement, an adequate catalyst surface of the SCR system also provides for the partial reduction of the emissions of PCDD/F. Applicability to existing plants may be restricted by space availability and/or by the presence of catalyst poisons in the waste gases. Substance/Parameter BAT-AEL (ng I-TEQ/Nm3) (Average over the sampling period) PCDD/F < 0,01-0,05 The associated monitoring is given in BAT 8. Grp. 1133. Organic compounds Grp. applicability. Recovery may be restricted where the energy demand for dust purification or decontamination is excessive. Reuse may be restricted due to product quality specifications. Grp. 13. In order to increase resource efficiency and to reduce the mass flow of dust and particulate-bound metals sent to the final waste gas treatment, BAT is to recover materials from process off-gases by using one or a combination of the techniques given below and to reuse them. Technique Description a. Cyclone See Section 1.4.1. b. Fabric filter See Section 1.4.1. c. Absorption See Section 1.4.1. Grp_14_table. 13. In order to reduce channelled emissions to air of dust and particulate-bound metals, BAT is to use one or a combination of the techniques given below. Technique Description Applicability a. Absolute filter See Section 1.4.1. Applicability may be limited in the case of sticky dust or when the temperature of the waste gases is below the dew point. b. Absorption See Section 1.4.1. Generally applicable. c. Fabric filter See Section 1.4.1. Applicability may be limited in the case of sticky dust or when the temperature of the waste gases is below the dew point. d. High-efficiency air filter See Section 1.4.1. Generally applicable. e. Cyclone See Section 1.4.1. Generally applicable. f. Electrostatic precipitator See Section 1.4.1. Generally applicable. Substance/Parameter BAT-AEL (mg/Nm3) (Daily average or average over the sampling period) Dust < 1-5 Lead and its compounds, expressed as Pb < 0,01-0,1 Nickel and its compounds, expressed as Ni < 0,02-0,1 The associated monitoring is given in BAT 8. Grp. 1134. Dust (including PM10 and PM2,5) and particulate-bound metals Grp. description. See Section 1.4.1. Grp. applicability. Recovery may be restricted where the energy demand is excessive due to the low concentration of the compound(s) concerned in the process off-gas(es). Reuse may be restricted due to product quality specifications. Grp. 15. In order to increase resource efficiency and to reduce the mass flow of inorganic compounds sent to the final waste gas treatment, BAT is to recover inorganic compounds from process off-gases by using absorption and to reuse them. Grp_16_table. 14. In order to reduce channelled emissions to air of CO, NOX and SOX from thermal treatment, BAT is to use technique c. and one or a combination of the other techniques given below. Technique Description Main inorganic compounds targeted Applicability a. Choice of fuel See Section 1.4.1. NOX, SOX Generally applicable. b. Low-NOX burner See Section 1.4.1. NOX Applicability to existing plants may be restricted by design and/or operational constraints. c. Optimisation of catalytic or thermal oxidation See Section 1.4.1. CO, NOX Generally applicable. d. Removal of high levels of NOX precursors Remove (if possible, for reuse) high levels of NOX precursors prior to thermal or catalytic oxidation, e.g. by absorption, adsorption or condensation. NOX Generally applicable. e. Absorption See Section 1.4.1. SOX Generally applicable. f. Selective catalytic reduction (SCR) See Section 1.4.1. NOX Applicability to existing plants may be restricted by space availability. g. Selective non-catalytic reduction (SNCR) See Section 1.4.1. NOX Applicability to existing plants may be restricted by the residence time needed for the reaction. Substance/Parameter BAT-AEL (mg/Nm3) (Daily average or average over the sampling period) Nitrogen oxides (NOX) from catalytic oxidation 5-30 Nitrogen oxides (NOX) from thermal oxidation 5-130 Carbon monoxide (CO) No BAT-AEL The associated monitoring is given in BAT 8. The BAT-AEL for channelled emissions to air of SO2 is given in Table 1.6. Grp_17_table. 15. In order to reduce channelled emissions to air of ammonia from the use of selective catalytic reduction (SCR) or selective non-catalytic reduction (SNCR) for the abatement of NOX emissions (ammonia slip), BAT is to optimise the design and/or operation of SCR or SNCR (e.g. optimised reagent to NOX ratio, homogeneous reagent distribution and optimum size of the reagent drops). Substance/Parameter BAT-AEL (mg/Nm3) (Average over the sampling period) Ammonia (NH3) from SCR/SNCR < 0,5-8 The associated monitoring is given in BAT 8. Grp_18_table. 16. In order to reduce channelled emissions to air of inorganic compounds other than channelled emissions to air of ammonia from the use of selective catalytic reduction (SCR) or selective non-catalytic reduction (SNCR) for the abatement of NOX emissions), channelled emissions to air of CO, NOX and SOX from the use of thermal treatment, and channelled emissions to air of NOX from process furnaces/heaters, BAT is to use one or a combination of the techniques given below. Technique Description Main inorganic compounds targeted Applicability Specific techniques to reduce emissions to air of inorganic compounds a. Absorption See Section 1.4.1. Cl2, HCl, HCN, HF, NH3, NOX, SOX Generally applicable. b. Adsorption See Section 1.4.1. For the removal of inorganic substances, the technique is often used in combination with a dust abatement technique (see BAT 14). HCl, HF, NH3, SOX Generally applicable. c. Selective catalytic reduction (SCR) See Section 1.4.1. NOX Applicability to existing plants may be restricted by space availability. d. Selective non-catalytic reduction (SNCR) See Section 1.4.1. NOX Applicability to existing plants may be restricted by the residence time needed for the reaction. Other techniques not primarily used to reduce emissions to air of inorganic compounds e. Catalytic oxidation See Section 1.4.1. NH3 Applicability may be restricted by the presence of catalyst poisons in the waste gases. f. Thermal oxidation See Section 1.4.1. NH3, HCN Applicability of recuperative and regenerative thermal oxidation to existing plants may be restricted by design and/or operational constraints. The applicability may be restricted where the energy demand is excessive due to the low concentration of the compound(s) concerned in the process off-gases. Substance/Parameter BAT-AEL (mg/Nm3) (Daily average or average over the sampling period) Ammonia (NH3) 2-10 Elemental chlorine (Cl2) < 0,5-2 Gaseous fluorides, expressed as HF ≤ 1 Hydrogen cyanide (HCN) < 0,1-1 Gaseous chlorides, expressed as HCl 1-10 Nitrogen oxides (NOX) 10-150 Sulphur oxides (SO2) < 3-150 The associated monitoring is given in BAT 8. Grp. 1135. Inorganic compounds Grp. 113. Channelled emissions to air (i) Estimating the annual quantity of diffuse VOC emissions (see BAT 20). (ii) Monitoring diffuse VOC emissions from the use of solvents by compiling a solvent mass balance, if applicable (see BAT 21). (a) Listing of equipment identified as relevant fugitive VOC emission sources in the inventory of diffuse VOC emissions (see BAT 2). (1) Leaky equipment. Typical criteria could be a leak threshold, above which equipment is considered leaky, and/or the visualisation of a leak with OGI cameras. This depends on the characteristics of the emission source (e.g. accessibility) and the hazardous properties of the emitted substance(s). (2) Maintenance and/or repair actions to be carried out. A typical criterion could be a VOC concentration threshold triggering the maintenance or repair action (maintenance/repair threshold). The maintenance/repair threshold is generally equal to or higher than the leak threshold. This depends on the characteristics of the emission source (e.g. accessibility) and the hazardous properties of the emitted substance(s). For the first LDAR programme, it is generally not higher than 5000 ppmv for VOCs other than VOCs classified as CMR 1A or 1B, and 1000 ppmv for VOCs classified as CMR 1A or 1B. For subsequent LDAR programmes, the maintenance/repair threshold is lowered (see point vi. a.) and not higher than 1000 ppmv for VOCs other than VOCs classified as CMR 1A or 1B, and 500 ppmv for VOCs classified as CMR 1A or 1B, targeting 100 ppmv. (b) Definition of criteria associated with the following: (c) Measuring fugitive VOC emissions from equipment listed under point iii. a. (see BAT 22). (d) Carrying out maintenance and/or repair actions (see BAT 23, techniques e. and f.), as soon as possible and where necessary according to the criteria defined in point iii. b. Maintenance and repair actions are prioritised according to the hazardous properties of the emitted substance(s), the significance of the emissions and/or operational constraints. The effectiveness of the maintenance and/or repair actions is verified according to point iii. c., leaving enough time after the intervention (e.g. 2 months). (e) Filling in the database mentioned in point v. (iii) Establishing and implementing a leak detection and repair (LDAR) programme for fugitive VOC emissions. The LDAR programme typically lasts from 1 to 5 years depending on the nature, scale and complexity of the plant (5 years may correspond to large plants with a high number of emission sources). The LDAR programme includes all of the following features: (a) Listing of equipment identified as relevant non-fugitive VOC emission sources in the inventory of diffuse VOC emissions (see BAT 2). (b) Monitoring non-fugitive VOC emissions from equipment listed under point iv. a. (see BAT 22). (c) Planning and implementing techniques to reduce non-fugitive VOC emissions (see BAT 23, techniques a., c. and g. to j.). The planning and implementation of the techniques are prioritised according to the hazardous properties of the emitted substance(s), the significance of the emissions and/or operational constraints. (d) Filling in the database mentioned in point v. (iv) Establishing and implementing a detection and reduction programme for non-fugitive VOC emissions that includes all of the following features: (a) equipment design specifications (including the date and description of any design changes); (b) the equipment maintenance, repair, upgrade, or replacement actions, performed or planned, and their date of implementation; (c) the equipment that could not be maintained, repaired, upgraded or replaced due to operational constraints; (d) the results of the measurements or monitoring, including the concentration(s) of the emitted substance(s), the calculated leak rate (as kg/year), the recording from OGI cameras (e.g. from the last LDAR programme) and the date of the measurements or monitoring; (e) the annual quantity of diffuse VOC emissions (as fugitive and non-fugitive emissions), including information on non-accessible sources and accessible sources not monitored during the year. (v) Establishing and maintaining a database, for diffuse VOC emissions sources that are identified in the inventory mentioned in BAT 2, for keeping record of: (a) lowering the leak and/or maintenance/repair thresholds (see point iii. b.); (b) reviewing the prioritisation of equipment to be monitored, giving higher priority to (the type of) equipment identified as leaky during the previous LDAR programme; (c) planning the maintenance, repair, upgrade or replacement of equipment that could not be performed during the previous LDAR programme due to operational constraints. (vi) Reviewing and updating the LDAR programme periodically. This may include the following: (a) monitoring non-fugitive VOC emissions from equipment where maintenance, repair, upgrade or replacement actions were implemented, in order to determine if those actions were successful; (b) planning the maintenance, repair, upgrade or replacement actions that could not be performed due to operational constraints. (vii) Reviewing and updating the detection and reduction programme for non-fugitive VOC emissions. This may include the following: Grp. applicability. The features points iii., iv., vi., and vii. are only applicable to sources of diffuse VOC emissions for which monitoring according to BAT 22 is applicable. The level of detail of the management system for diffuse VOC emissions will be proportionate to the nature, scale and complexity of the plant, and the range of environmental impacts it may have. Grp. 19. In order to prevent or, where that is not practicable, to reduce diffuse VOC emissions to air, BAT is to elaborate and implement a management system for diffuse VOC emissions, as part of the environmental management system (see BAT 1), that includes all of the following features: Grp. 1141. Management system for diffuse VOC emissions (1) chemical properties of the substance (e.g. vapour pressure, molecular mass); (2) process operating data (e.g. operating time, product quantity, ventilation); (3) characteristics of the emission source (e.g. tank diameter, colour, shape). Grp. note. The estimation of the diffuse VOC emissions to air takes into account the results of the monitoring carried out according to BAT 21 and/or to BAT 22. For the purpose of the estimation, channelled emissions may be counted as non-fugitive emissions when the inherent characteristics of the waste gas stream (e.g. low velocities, variability of the flow rate and concentration) do not allow an accurate measurement according to BAT 8. The main sources of uncertainty of the estimation are identified, and corrective actions are implemented to reduce the uncertainty. Technique Description Type of emissions a. Use of emission factors See Section 1.4.2. Fugitive and/or non-fugitive b. Use of a mass balance Estimation based on the difference in the mass of the substance inputs to and outputs from the plant/production unit, taking into account the generation and destruction of the substance in the plant/production unit. A mass balance may also consist of measuring the concentration of VOCs in the product (e.g. raw material or solvent). c. Use of thermodynamic models Estimation using the laws of thermodynamics applied to equipment (e.g. tanks) or particular steps of a production process. The following data are generally used as input for the model: Grp. 20. BAT is to estimate fugitive and non-fugitive VOC emissions to air separately at least once every year by using one or a combination of the techniques given below, as well as to determine the uncertainty of this estimation. The estimation distinguishes between VOCs classified as CMR 1A or 1B and VOCs that are not classified as CMR 1A or 1B. (1) identification and documentation of solvent inputs and outputs (e.g. channelled and diffuse emissions to air, emissions to water, solvent output in waste); (2) substantiated quantification of each relevant solvent input and output and recording of the methodology used (e.g. measurement, estimation by using emission factors, estimation based on operational parameters); (3) identification of the main sources of uncertainty of the aforementioned quantification, and implementation of corrective actions to reduce the uncertainty; (4) regular update of solvent input and output data. (5) malfunctions of the waste gas treatment system: the date and period of time are recorded; (6) changes that may influence air/gas flow rates (e.g. replacement of fans): the date and type of change are recorded. Grp. applicability. This BAT may not apply to the production of polyolefins, PVC or synthetic rubbers. This BAT may not be applicable to plants whose total annual consumption of solvents is lower than 50 tonnes. The level of detail of the solvent mass balance will be proportionate to the nature, scale and complexity of the plant, and the range of environmental impacts it may have, as well as to the type and quantity of solvents used. Grp. 21. BAT is to monitor diffuse VOC emissions from the use of solvents by compiling, at least once every year, a solvent mass balance of the solvent inputs and outputs of the plant, as defined in Part 7 of Annex VII to Directive 2010/75/EU and to minimise the uncertainty of the solvent mass balance data by using all of the techniques given below. Technique Description a. Full identification and quantification of the relevant solvent inputs and outputs, including the associated uncertainty This includes: b. Implementation of a solvent tracking system A solvent tracking system aims to keep control of both the used and unused quantities of solvents (e.g. by weighing unused quantities returned to storage from the application area). c. Monitoring of changes that may influence the uncertainty of the solvent mass balance data Any change that could influence the uncertainty of the solvent mass balance data is recorded, such as: Grp. note. Optical gas imaging (OGI) is a useful complementary technique to the method EN 15446 (sniffing) in order to identify sources of fugitive VOC emissions and is particularly relevant in the case of inaccessible sources (see Section 1.4.2.). This technique is described in EN 17628. In the case of non-fugitive emissions, measurements may be complemented by the use of thermodynamic models. Where large amounts (e.g. above 80 t/yr) of VOCs are used/consumed, the quantification of VOC emissions from the plant with tracer correlation (TC) or with optical absorption-based techniques, such as differential absorption light detection and ranging (DIAL) or solar occultation flux (SOF), is a useful complementary technique (see Section 1.4.2.). These techniques are described in EN 17628. (1) 1 tonne of VOCs per year in the case of VOCs classified as CMR 1A or 1B; or (2) 5 tonnes of VOCs per year in the case of other VOCs. (3) 1 tonne of VOCs per year in the case of VOCs classified as CMR 1A or 1B; or (4) 5 tonnes of VOCs per year in the case of other VOCs. Grp. applicability. BAT 22 only applies when the annual quantity of diffuse VOC emissions from the plant estimated according to BAT 20 is greater than the following: For fugitive emissions: For non-fugitive emissions: Grp. 22. BAT is to monitor diffuse VOC emissions to air with at least the frequency given below and in accordance with EN standards. If EN standards are not available, BAT is to use ISO, national or other international standards that ensure the provision of data of an equivalent scientific quality. Type of sources of diffuse VOC emissions Type of VOCs Standard(s) Minimum monitoring frequency Sources of fugitive emissions VOCs classified as CMR 1A or 1B EN 15446 Once every year VOCs not classified as CMR 1A or 1B Once during the period covered by each LDAR programme (see BAT 19 point iii.) Sources of non-fugitive emissions VOCs classified as CMR 1A or 1B EN 17628 Once every year VOCs not classified as CMR 1A or 1B Once every year Grp. 1142. Monitoring (1) minimising pipe lengths; (2) reducing the number of pipe connectors (e.g. flanges) and valves; (3) using welded fittings and connections; (4) using compressed air or gravity for material transfer. (5) bellow valves or double packing seals or equally effective equipment; (6) magnetically driven or canned pumps/compressors/agitators, or pumps/compressors/agitators using double seals and a liquid barrier; (7) certified high-quality gaskets (e.g. according to EN 13555) that are tightened according to technique e.; (8) closed sampling system. (9) emissions of CMR substances or substances with acute toxicity; and/or (10) emissions from equipment with high-leaking potential; and/or (11) leaks from processes operated at high pressures (e.g. between 300 bar and 2000 bar). (12) for existing plants; and/or (13) by safety concerns (e.g. avoiding concentrations close to the lower explosive limit). (14) tightening of gaskets by personnel that is qualified according to EN 1591-4 and using the designed gasket stress (e.g. calculated according to EN 1591-1); (15) installing tight caps on open ends; (16) using flanges selected and assembled according to EN 13555. (17) gaskets; (18) sealing elements (e.g. tank lid); (19) packing material (e.g. valve stem packing material). (20) reducing the use of solvents and/or using solvents with lower volatility; (21) reducing the formation of side products containing VOCs; (22) lowering the operating temperature; (23) lowering the VOC content in the final product. (24) reducing the frequency and duration of reactor and vessel openings; (25) preventing corrosion by lining or coating of equipment, by painting pipes (for external corrosion) and by using corrosion inhibitors for materials in contact with equipment. (26) vapour balancing (see Section 1.4.3); (27) closed systems for solid/liquid and liquid/liquid phase separations; (28) closed systems for cleaning operations; (29) closed sewers and/or waste water treatment plants; (30) closed sampling systems; (31) closed storage areas. (32) installing oil creaming systems on open surfaces; (33) periodically skimming open surfaces (e.g. removing floating matter); (34) installing anti-evaporation floating elements on open surfaces; (35) treating waste water streams to remove VOCs and send the VOCs to recovery (see BAT 9 and BAT 10) and/or abatement (see BAT 11); (36) installing floating roofs on tanks; (37) using fixed-roof tanks connected to a waste gas treatment. Grp. 1. The use of techniques to prevent or, where that is not practicable, to reduce diffuse VOC emissions to air is prioritised according to the hazardous properties of the emitted substance(s) and/or the significance of the emissions. Technique Description Type of emissions Applicability Prevention techniques a. Limiting the number of emission sources This includes: Fugitive and non-fugitive emissions Applicability may be restricted by operational constraints in the case of existing plants. b. Use of high-integrity equipment High-integrity equipment includes, but is not limited to: The use of high-integrity equipment is especially relevant to prevent or minimise: High-integrity equipment is selected, installed and maintained according to the type of process and the process operating conditions. Fugitive emissions Applicability may be restricted by operational constraints in the case of existing plants. Generally applicable to new plants and major plant upgrades. c. Collecting diffuse emissions and treating off-gases Collecting diffuse VOC emissions (e.g. from compressor seals, vents and purge lines) and sending them to recovery (see BAT 9 and BAT 10) and/or abatement (see BAT 11). Fugitive and non-fugitive emissions Applicability may be restricted: Other techniques d. Facilitating access and/or monitoring activities To ease maintenance and/or monitoring activities, the access to potentially leaky equipment is facilitated, e.g. by installing platforms, and/or drones are used for monitoring. Fugitive emissions Applicability may be restricted by operational constraints in the case of existing plants. e. Tightening This includes: Fugitive emissions Generally applicable. f. Replacement of leaky equipment and/or parts This includes the replacement of: Fugitive emissions Generally applicable. g. Reviewing and updating process design This includes: Non-fugitive emissions Applicability may be restricted in the case of existing plants due to operational constraints. h. Reviewing and updating operating conditions This includes: Non-fugitive emissions Generally applicable. i. Using closed systems This includes: Off-gases from closed systems are sent to recovery (see BAT 9 and BAT 10) and/or abatement (see BAT 11). Non-fugitive emissions Applicability may be restricted by operational constraints in the case of existing plants and/or by safety concerns. j. Using techniques to minimise emissions from surfaces This includes: Non-fugitive emissions Applicability may be restricted by operational constraints in the case of existing plants. Grp. 23. In order to prevent or, where that is not practicable, to reduce diffuse VOC emissions to air, BAT is to use a combination of the techniques given below with the following order of priority. Grp. 1143. Prevention or reduction of diffuse VOC emissions Grp_1144_table. 17. BAT conclusions for the use of solvents or the reuse of recovered solvents The emission levels for the use of solvents or the reuse of recovered solvents given below are associated with the general BAT conclusions given in Section 1.1 and Section 1.1.4.3. Parameter BAT-AEL (percentage of the solvent inputs) (yearly average) Diffuse VOC emissions ≤ 5 % The associated monitoring is given in BAT 20, BAT 21 and BAT 22. Grp. 114. Diffuse VOC emissions to air Grp. 11. General BAT conclusions Grp. note. The measurement samples are taken at the point of transition from the closed to the open system where the polyolefin comes into contact with the atmosphere. The closed system refers to the part of the production process where the materials (e.g. reactants, solvents, suspension agents) are not in contact with the atmosphere. It includes the polymerisation steps, the reuse and recovery of materials. The open system refers to the part of the production process where the polyolefins come into contact with the atmosphere. It includes the finishing steps (e.g. drying, blending) as well as the transfer, handling and storage of polyolefins. When the transition point between the open and the closed system cannot be clearly identified, the measurement samples are taken at an appropriate point. Grp. applicability. Measurements do not apply to production processes only made up of a closed system. Grp. 24. BAT is to monitor the TVOC concentration in polyolefin products, at least once every year for each representative polyolefin grade produced during the same year, in accordance with EN standards. If EN standards are not available, BAT is to use ISO, national or other international standards that ensure the provision of data of an equivalent scientific quality. Polyolefin product Standard(s) Monitoring associated with HDPE, LDPE, LLDPE No EN standard available BAT 20, BAT 25 PP EPS, GPPS, HIPS Grp_25_table. 18. In order to increase resource efficiency and to reduce emissions to air of organic compounds, BAT is to use all of the techniques given below, as far as applicable. Technique Description Applicability a. Chemical agents with low boiling points Solvents and suspension agents with low boiling points are used. Applicability may be restricted by operational constraints. b. Lowering the VOC content in the polymer The VOC content in the polymer is lowered, e.g. by using low-pressure separation, stripping or closed-loop nitrogen purge systems, devolatilisation extrusion (see Section 1.4.3). The techniques for lowering the VOC content depend on the type of polymer product and production process. Devolatilisation extrusion may be restricted by product specifications for the production of HDPE, LDPE and LLDPE. c. Collection and treatment of process off-gases Process off-gases arising from the use of technique b. as well as from the finishing step, e.g. extrusion and degassing silos, are collected and sent to recovery (see BAT 9 and BAT 10) and/or abatement (see BAT 11). Applicability may be restricted by operational constraints and/or due to safety concerns (e.g. avoiding concentrations close to the lower/upper explosive limit). Polyolefin product Unit BAT-AEL (Yearly average) HDPE g C per kg of polyolefins produced 0,3-1,0 LDPE 0,1-1,4 LLDPE 0,1-0,8 PP 0,1-0,9 GPPS and HIPS < 0,1 EPS < 0,6 The associated monitoring is given in BAT 8, BAT 20, BAT 22 and BAT 24. The monitoring of TVOC emissions to air includes all emissions from the following process steps, where the emissions are identified as relevant in the inventory given in BAT 2: storage and handling of raw materials, polymerisation, recovery of materials and pollutant abatement, finishing of the polymer (e.g. extrusion, drying, blending) as well as the transfer, handling and storage of polymers. Grp. 121. BAT conclusions for the production of polyolefins Grp. 26. BAT is to monitor channelled emissions to air with at least the frequency given below and in accordance with EN standards. If EN standards are not available, BAT is to use ISO, national or other international standards that ensure the provision of data of an equivalent scientific quality. Substance Emission points Standard(s) Minimum monitoring frequency Monitoring associated with VCM Any stack with a VCM mass flow of ≥ 25 g/h Generic EN standards Continuous BAT 29 Any stack with a VCM mass flow of < 25 g/h No EN standard available Once every 6 months Grp. note. The samples of the PVC slurry/latex are taken at the point of transition from the closed to the open system where the PVC slurry/latex comes into contact with the atmosphere. The closed system refers to the part of the production process where the PVC slurry/latex is not in contact with the atmosphere. It generally includes the polymerisation steps, the reuse and recovery of VCM. The open system is the part of the system where the PVC slurry/latex comes into contact with the atmosphere. It includes the finishing steps (e.g. drying and blending) as well as the transfer, handling and storage of PVC. Grp. 27. BAT is to monitor the residual vinyl chloride monomer concentration in PVC slurry/latex, at least once every year for each representative PVC grade produced during the same year, in accordance with EN standards. Substance Standard(s) Monitoring associated with VCM EN ISO 6401 BAT 30 Grp. applicability. Recovery may be restricted where the energy demand is excessive due to the low concentration of the compound(s) concerned in the process off-gas(es). Grp. 28. In order to increase resource efficiency and to reduce the mass flow of organic compounds sent to the final waste gas treatment, BAT is to recover the vinyl chloride monomer from process off-gases by using one or a combination of the techniques given below, and to reuse the recovered monomer. Technique Description a. Absorption (regenerative) See Section 1.4.1. b. Adsorption (regenerative) See Section 1.4.1. c. Condensation See Section 1.4.1. Grp_29_table. 19. In order to reduce channelled emissions to air of vinyl chloride monomer from the recovery of vinyl chloride monomer, BAT is to use one or a combination of the techniques given below. Technique Description Applicability a. Absorption See Section 1.4.1. Generally applicable b. Adsorption See Section 1.4.1. c. Condensation See Section 1.4.1. d. Thermal oxidation See Section 1.4.1. Applicability of recuperative and regenerative thermal oxidation to existing plants may be restricted by design and/or operational constraints. Applicability may be restricted where the energy demand is excessive due to the low concentration of the compound(s) concerned in the process off-gases. Substance BAT-AEL (mg/Nm3) (Daily average or average over the sampling period) VCM < 0,5-1 The associated monitoring is given in BAT 26. (1) storing VCM in refrigerated tanks at atmospheric pressure or in pressurised tanks at ambient temperature; (2) using refrigerated reflux condensers or connecting tanks for VCM recovery (see BAT 28) and/or abatement (see BAT 29). (3) reducing the frequency and duration of reactor openings; (4) venting off-gases from latex storage tanks and from connections to VCM recovery (see BAT 28) and/or abatement (see BAT 29) prior to opening the reactor; (5) flushing the reactor with inert gas prior to opening and venting off-gases to VCM recovery (see BAT 28) and/or abatement (see BAT 29); (6) draining the liquid content of the reactor to closed vessels prior to opening the reactor; (7) cleaning the reactor with water prior to opening and draining the water to the stripping system. Grp. 30. In order to reduce emissions to air of vinyl chloride monomer, BAT is to use all of the techniques given below. Technique Description a. Appropriate VCM storage facilities This includes: b. Vapour balancing See Section 1.4.3. c. Minimisation of emissions of residual VCM from equipment This includes: d. Lowering the VCM content in the polymer by stripping See Section 1.4.3. e. Collection and treatment of process off-gases Process off-gases from the use of technique d. are collected and sent to VCM recovery (see BAT 28) and/or abatement (see BAT 29). PVC type Unit BAT-AEL (Yearly average) S-PVC g VCM per kg of PVC produced 0,01-0,045 E-PVC 0,25-0,3 The associated monitoring is given in BAT 20, BAT 22, BAT 26 and BAT 27. The monitoring of VCM emissions to air includes all emissions from the following process steps or equipment, where the emissions are identified as relevant in the inventory given in BAT 2: finishing, e.g. drying and blending; transfer, handling and storage; reactor openings; gasholders; waste water treatment plants; recovery and/or abatement of VCM. PVC type Unit BAT-AEL (Yearly average) S-PVC g VCM per kg of PVC produced 0,01-0,03 E-PVC 0,2-0,4 The associated monitoring is given in BAT 27. Grp. 122. BAT conclusions for the production of polyvinyl chloride (PVC) Grp. note. The samples are taken after lowering the VOC content in the polymer (see BAT 32 a.) where the synthetic rubber comes into contact with the atmosphere. Grp. applicability. Measurements do not apply to production processes only made up of a closed system. Grp. 31. BAT is to monitor the TVOC concentration in synthetic rubbers, at least once every year for each representative synthetic rubber grade produced during the same year, in accordance with EN standards. If EN standards are not available, BAT is to use ISO, national or other international standards that ensure the provision of data of an equivalent scientific quality. Substance/Parameter Standard(s) Monitoring associated with VOCs No EN standard available BAT 32 Grp_32_table. 112. In order to reduce emissions to air of organic compounds, BAT is to use one or a combination of the techniques given below. Technique Description a. Lowering the VOC content in the polymer The VOC content in the polymer is lowered by using stripping or devolatilisation extrusion (see Section 1.4.3). b. Collection and treatment of process off-gases Process off-gases are collected and sent to recovery (see BAT 9 and BAT 10) and/or abatement (see BAT 11). Substance/Parameter Unit BAT-AEL (Yearly average) TVOC g C per kg of synthetic rubber produced 0,2-4,2 The associated monitoring is given in BAT 8, BAT 20, BAT 22 and BAT 31. The monitoring of TVOC emissions to air includes all emissions from the following process steps, where the emissions are identified as relevant in the inventory given in BAT 2: storage of raw materials, polymerisation, recovery of materials and abatement techniques, finishing of the polymer (e.g. extrusion, drying, blending) as well as the transfer, handling and storage of synthetic rubbers. Grp. 123. BAT conclusions for the production of synthetic rubbers Grp. 33. BAT is to monitor channelled emissions to air with at least the frequency given below and in accordance with EN standards. If EN standards are not available, BAT is to use ISO, national or other international standards that ensure the provision of data of an equivalent scientific quality. Substance Emission points Standard(s) Minimum monitoring frequency Monitoring associated with Carbon disulphide (CS2) Any stack with a mass flow of ≥ 1 kg/h Generic EN standards Continuous BAT 35 Any stack with a mass flow of < 1 kg/h No EN standard available Once every year Hydrogen sulphide (H2S) Any stack with a mass flow of ≥ 50 g/h Generic EN standards Continuous Any stack with a mass flow of < 50 g/h No EN standard available Once every year Grp. 34. In order to increase resource efficiency and to reduce the mass flow of CS2 and H2S sent to the final waste gas treatment, BAT is to recover CS2 by using technique a. and/or technique b. or a combination of technique c. with technique(s) a. and/or b., given below and to reuse the CS2, or, alternatively, to use technique d. Technique Main substance targeted Description Applicability a. Absorption (regenerative) H2S See Section 1.4.1. Generally applicable for the production of casing. For other products, applicability may be restricted where the energy demand is excessive due to high waste gas volume flows (above e.g. 120000 Nm3/h) or low H2S concentration in the waste gas (below e.g. 0,5 g/Nm3). b. Adsorption (regenerative) H2S, CS2 See Section 1.4.1. Applicability may be restricted where the energy demand for recovery is excessive if the concentration of CS2 in the waste gas is below e.g. 5 g/Nm3. c. Condensation H2S, CS2 See Section 1.4.1. d. Production of sulphuric acid H2S, CS2 Process off-gases containing CS2 and H2S are used to produce sulphuric acid. Applicability may be restricted if the concentration of CS2 and/or H2S in the waste gas is below 5 g/Nm3. Grp_35_table. 113. In order to reduce channelled emissions to air of CS2 and H2S, BAT is to use one or a combination of the techniques given below. Technique Main substance targeted Description Applicability a. Absorption H2S See Section 1.4.1. Generally applicable. b. Bioprocesses CS2, H2S See Section 1.4.1. Applicability may be restricted where the energy demand is excessive due to high waste gas volume flows (e.g. above 60000 Nm3/h) or high CS2 concentration in the waste gas (e.g. above 1 000 mg/Nm3) or too low H2S concentration. c. Thermal oxidation CS2, H2S See Section 1.4.1. Applicability of recuperative and regenerative thermal oxidation to existing plants may be restricted by design and/or operational constraints. Applicability may be restricted where the energy demand is excessive due to the low concentration of the compound(s) concerned in the process off-gases. Substance BAT-AEL (mg/Nm3) (Daily average or average over the sampling period) CS2 5-400 H2S 1-10 The associated monitoring is given in BAT 33. Parameter Process Unit BAT-AEL (Yearly average) Sum of H2S and CS2 (expressed as Total S) Production of staple fibres g Total S per kg of product 6-9 Casing 120-250 The associated monitoring is given in BAT 33. Grp. 124. BAT conclusions for the production of viscose using CS2 Grp. 12. Polymers and synthetic rubbers The BAT conclusions presented in this section apply to the production of certain polymers. They apply in addition to the general BAT conclusions given in Section 1.1. Grp_36_table. 115. In order to prevent or, where that is not practicable, to reduce channelled emissions to air of CO, dust, NOX and SOX, BAT is to use technique c. and one or a combination of the other techniques given below. Technique Description Main inorganic compounds targeted Applicability Primary techniques a. Choice of fuel See Section 1.4.1. This includes switching from liquid to gaseous fuels, taking into account the overall hydrocarbon balance. NOX, SOX, dust The switch from liquid to gaseous fuels may be restricted by the design of the burners in the case of existing process furnaces/heaters. b. Low-NOX burner See Section 1.4.1. NOX For existing process furnaces/heaters, the applicability may be restricted by their design. c. Optimised combustion See Section 1.4.1. CO, NOX Generally applicable. Secondary techniques d. Absorption See Section 1.4.1. SOX, dust Applicability may be restricted for existing process furnaces/heaters by space availability. e. Fabric filter or absolute filter See Section 1.4.1. Dust Not applicable when only combusting gaseous fuels. f. Selective catalytic reduction (SCR) See Section 1.4.1. NOX Applicability to existing process furnaces/heaters may be restricted by space availability. g. Selective non-catalytic reduction (SNCR) See Section 1.4.1. NOX Applicability to existing process furnaces/heaters may be restricted by the temperature window (800-1100 °C) and the residence time needed for the reaction. Parameter BAT-AEL (mg/Nm3) (Daily average or average over the sampling period) Nitrogen oxides (NOX) 30-150 Carbon monoxide (CO) No BAT-AEL The associated monitoring is given in BAT 8. Grp. 13. Process furnaces/heaters The BAT conclusions presented in this section apply when process furnaces/heaters with a total rated thermal input equal to or greater than 1 MW are used in the production processes included in the scope of these BAT conclusions. They apply in addition to the general BAT conclusions given in Section 1.1. Where the waste gases of two or more separate process furnaces/heaters are, or could, in the judgement of the competent authority, be discharged through a common stack, the capacities of all individual furnaces/heaters shall be added together for the purpose of calculating the total rated thermal input. (1) Biofiltration: the waste gas stream is passed through a bed of organic material (such as peat, heather, compost, root wood, tree bark, peat, compost, softwood and different kinds of combinations) or some inert material (such as clay, activated carbon, and polyurethane), where it is biologically oxidised by naturally occurring microorganisms into carbon dioxide, water, inorganic salts and biomass. (2) Bioscrubbing: the removal of the pollutant compounds from a waste gas stream using a combination of wet scrubbing (absorption) and biodegradation under aerobic conditions. The scrubbing water contains a population of microorganisms suitable to oxidise biodegradable gaseous compounds. The absorbed pollutants are degraded in aerated sludge tanks. (3) Biotrickling: the removal of the pollutant compounds from a waste gas stream in a biological trickle-bed reactor. The pollutants are absorbed by the water phase and transported to the biofilm, where the biological transformation takes place. (4) Straight thermal oxidation: thermal oxidation without energy recovery from the combustion. (5) Recuperative thermal oxidation: thermal oxidation using the heat of the waste gases by indirect heat transfer. (6) Regenerative thermal oxidation: thermal oxidation where the incoming waste gas stream is heated when passing through a ceramic-packed bed before entering the combustion chamber. The purified hot gases exit this chamber by passing through one (or more) ceramic-packed bed(s) (cooled by an incoming waste gas stream in an earlier combustion cycle). This reheated packed bed then begins a new combustion cycle by preheating a new incoming waste gas stream. Grp. 141. Techniques to reduce channelled emissions to air Technique Description Absorption The removal of gaseous or particulate pollutants from a process off-gas or waste gas stream via mass transfer to a suitable liquid, often water or an aqueous solution. It may involve a chemical reaction (e.g. in an acid or alkaline scrubber). In the case of regenerative absorption, the compounds may be recovered from the liquid. Adsorption The removal of pollutants from a process off-gas or waste gas stream by retention on a solid surface (activated carbon is typically used as the adsorbent). Adsorption may be regenerative or non-regenerative. In non-regenerative adsorption, the spent adsorbent is not regenerated but disposed of. In the case of regenerative adsorption, the adsorbate is subsequently desorbed, e.g. with steam (often on site), for reuse or disposal and the adsorbent is reused. For continuous operation, typically more than two adsorbers are operated in parallel, one of them in desorption mode. Bioprocesses Bioprocesses include the following: Choice of fuel The use of fuel (including support/auxiliary fuel) with a low content of potential pollution-generating compounds (e.g. low sulphur, ash, nitrogen, fluorine or chlorine content in the fuel). Condensation The removal of vapours of organic and inorganic compounds from a process off-gas or waste gas stream by reducing its temperature below its dew point so that the vapours liquefy. Depending on the operating temperature range required, different cooling media are used, e.g. water or brine. In cryogenic condensation, liquid nitrogen is used as a cooling medium. Cyclone Equipment for the removal of dust from a process off-gas or waste gas stream based on imparting centrifugal forces, usually within a conical chamber. Electrostatic precipitator An electrostatic precipitator (ESP) is a particulate control device that uses electrical forces to move particles entrained within a waste gas stream onto collector plates. The entrained particles are given an electrical charge when they pass through a corona where gaseous ions flow. Electrodes in the centre of the flow lane are maintained at a high voltage and generate the electrical field that forces the particles to the collector walls. The pulsating DC voltage required is in the range of 20-100 kV. Absolute filter Absolute filters, also referred to as high-efficiency particle air (HEPA) filters or ultra-low penetration air (ULPA) filters, are constructed from glass cloth or fabrics of synthetic fibres through which gases are passed to remove particles. Absolute filters show higher efficiencies than fabric filters. The classification of HEPA and ULPA filters according to their performance is given in EN 1822-1. High-efficiency air filter (HEAF) A flat-bed filter in which aerosols combine into droplets. Highly viscous droplets remain on the filter fabric which contains the residues to be disposed of and separated into droplets, aerosols and dust. HEAFs are particularly suitable for treating highly viscous droplets. Fabric filter Fabric filters, often referred to as bag filters, are constructed from porous woven or felted fabric through which gases are passed to remove particles. The use of a fabric filter requires the selection of a fabric suitable for the characteristics of the waste gas and the maximum operating temperature. Low-NOX burner The technique (including ultra-low-NOX burner) is based on the principles of reducing peak flame temperatures. The air/fuel mixing reduces the availability of oxygen and reduces the peak flame temperature, thus retarding the conversion of fuel-bound nitrogen to NOX and the formation of thermal NOX, while maintaining high combustion efficiency. The design of ultra-low-NOX burners includes (air/)fuel staging and exhaust/flue-gas recirculation. Optimised combustion Good design of the combustion chambers, burners and associated equipment/devices is combined with optimisation of combustion conditions (e.g. the temperature and residence time in the combustion zone, efficient mixing of the fuel and combustion air) and the regular planned maintenance of the combustion system according to suppliers’ recommendations. Combustion conditions control is based on the continuous monitoring and automated control of appropriate combustion parameters (e.g. O2, CO, fuel to air ratio, and unburnt substances). Optimisation of catalytic or thermal oxidation Optimisation of design and operation of catalytic or thermal oxidation to promote the oxidation of organic compounds including PCDD/F present in the waste gases, to prevent PCDD/F and the (re)formation of their precursors, as well as to reduce the generation of pollutants such as NOX and CO. Catalytic oxidation Abatement technique which oxidises combustible compounds in a waste gas stream with air or oxygen in a catalyst bed. The catalyst enables oxidation at lower temperatures and in smaller equipment compared to thermal oxidation. The typical oxidation temperature is between 200 °C and 600 °C. For process off-gases with low VOC concentrations (e.g. < 1 g/Nm3), pre-concentration steps may be applied using adsorption (rotor or fixed bed, with activated carbon or zeolites). VOCs adsorbed in the concentrator are desorbed by using heated ambient air or heated waste gas, and the resulting volume flow with higher VOC concentration is directed to the oxidiser. Molecular sieves (smoothers), typically composed of zeolites, may be used before the concentrators or the oxidiser to level down high variations of VOC concentrations in the process off-gases. Thermal oxidation Abatement technique which oxidises combustible compounds in a waste gas stream by heating it with air or oxygen to above its auto-ignition point in a combustion chamber and maintaining it at a high temperature long enough to complete its combustion to carbon dioxide and water. The typical combustion temperature is between 800 °C and 1000 °C. Several types of thermal oxidation are operated: For process off-gases with low VOC concentrations (e.g. < 1 g/Nm3), pre-concentration steps may be applied using adsorption (rotor or fixed bed, with activated carbon or zeolites). VOCs adsorbed in the concentrator are desorbed by using heated ambient air or heated waste gas, and the resulting volume flow with higher VOC concentration is directed to the oxidiser. Molecular sieves (smoothers), typically composed of zeolites, may be used before the concentrators or the oxidiser to level down high variations of VOC concentrations in the process off-gases. Selective catalytic reduction (SCR) Selective reduction of nitrogen oxides with ammonia or urea in the presence of a catalyst. The technique is based on the reduction of NOX to nitrogen in a catalytic bed by reaction with ammonia at an optimum operating temperature that is typically around 200– 450 °C. In general, ammonia is injected as an aqueous solution; the ammonia source can also be anhydrous ammonia or a urea solution. Several layers of catalyst may be applied. A higher NOX reduction is achieved with the use of a larger catalyst surface, installed as one or more layers. In-duct or slip SCR combines SNCR with downstream SCR which reduces the ammonia slip from SNCR. Selective non-catalytic reduction (SNCR) Selective reduction of nitrogen oxides to nitrogen with ammonia or urea at high temperatures and without catalyst. The operating temperature window is maintained between 800 °C and 1000 °C for optimal reaction. Grp. 142. Techniques to monitor diffuse emissions to air Technique Description Differential absorption LIDAR (DIAL) A laser-based technique using differential absorption LIDAR (light detection and ranging), which is the optical analogue of radio-wave-based RADAR. The technique relies on the back-scattering of laser beam pulses by atmospheric aerosols, and the analysis of the spectral properties of the returned light collected with a telescope. Emission factor Emission factors are numbers that can be multiplied by an activity rate (e.g. the production output), in order to estimate the emissions from the installation. Emission factors are generally derived through the testing of a population of similar process equipment or process steps. This information can be used to relate the quantity of material emitted to some general measure of the scale of activity. In the absence of other information, default emission factors (e.g. literature values) can be used to provide an estimate of the emissions. Emission factors are usually expressed as the mass of a substance emitted divided by the throughput of the process emitting the substance. Leak Detection and Repair (LDAR) programme A structured approach to reduce fugitive VOC emissions by detection and subsequent repair or replacement of leaking components. The LDAR programme consists of one or more campaigns. A campaign is usually conducted over 1 year, where a certain percentage of the pieces of equipment is monitored. Optical gas imaging (OGI) methods Optical gas imaging uses small lightweight hand-held or fixed cameras which enable the visualisation of gas leaks in real time, so that they appear as smoke on a video recorder together with the image of the equipment concerned, to easily and rapidly locate significant VOC leaks. Active systems produce an image with a back-scattered infrared laser light reflected on the equipment and its surroundings. Passive systems are based on the natural infrared radiation of the equipment and its surroundings. Solar occultation flux (SOF) The technique is based on the recording and spectrometric Fourier Transform analysis of a broadband infrared or ultraviolet/visible sunlight spectrum along a given geographical itinerary, crossing the wind direction and cutting through VOC plumes. Grp. 143. Techniques to reduce diffuse emissions Technique Description Devolatilisation extrusion When the concentrated rubber solution is further processed by extrusion, the solvent vapours (commonly cyclohexane, hexane, heptane, toluene, cyclopentane, isopentane or mixtures thereof) coming from the vent hole of the extruder are compressed and sent to recovery. Stripping VOCs contained in the polymer are transferred to the gaseous phase (e.g. by using steam). The removal efficiency may be optimised by a suitable combination of temperature, pressure and residence time and by maximising the ratio of free polymer surface to total polymer volume. Vapour balancing The vapour from a piece of receiving equipment (e.g. a tank) that is displaced during the transfer of a liquid and is returned to the delivery equipment from which the liquid is delivered. Grp. 14. Description of techniques
1. SCOPE
These BAT conclusions concern the following activity specified in Annex I to Directive 2010/75/EU: 4. Chemical industry (i.e. all production processes included in the categories of activities listed in points 4.1 to 4.6 of Annex I, unless specified otherwise). More specifically, these BAT conclusions focus on emissions to air from the aforementioned activity. These BAT conclusions do not address the following: Other BAT conclusions which are complementary for the activities covered by these BAT conclusions include Common Waste Water and Waste Gas Treatment/Management Systems in the Chemical Sector (CWW). Other BAT conclusions and reference documents which could be relevant for the activities covered by these BAT conclusions are the following: These BAT conclusions apply without prejudice to other relevant legislation, e.g. on the registration, evaluation, authorisation and restriction of chemicals (REACH) or on classification, labelling and packaging of substances and mixtures (CLP). (1) Emissions to air from the production of chlorine, hydrogen, and sodium/potassium hydroxide by the electrolysis of brine. This is covered by the BAT conclusions for the Production of Chlor-alkali (CAK). (1) lower olefins using the steam cracking process; (2) formaldehyde; (3) ethylene oxide and ethylene glycols; (4) phenol from cumene; (5) dinitrotoluene from toluene, toluene diamine from dinitrotoluene, toluene diisocyanate from toluene diamine, methylene diphenyl diamine from aniline, methylene diphenyl diisocyanate from methylene diphenyl diamine; (6) ethylene dichloride (EDC) and vinyl chloride monomer (VCM); (7) hydrogen peroxide. (2) Channelled emissions to air from the production of the following chemicals in continuous processes where the total production capacity of those chemicals exceeds 20 kt/yr: This is covered by the BAT conclusions for the Production of Large Volume Organic Chemicals (LVOC). However, channelled emissions to air of nitrogen oxides (NOX) and carbon monoxide (CO) from thermal treatment of waste gases originating from the aforementioned production processes are included in the scope of these BAT conclusions. (1) ammonia; (2) ammonium nitrate; (3) calcium ammonium nitrate; (4) calcium carbide; (5) calcium chloride; (6) calcium nitrate; (7) carbon black; (8) ferrous chloride; (9) ferrous sulphate (i.e. copperas and related products, such as chloro-sulphates); (10) hydrofluoric acid; (11) inorganic phosphates; (12) nitric acid; (13) nitrogen-, phosphorus- or potassium-based fertilisers (simple or compound fertilisers); (14) phosphoric acid; (15) precipitated calcium carbonate; (16) sodium carbonate (i.e. soda ash); (17) sodium chlorate; (18) sodium silicate; (19) sulphuric acid; (20) synthetic amorphous silica; (21) titanium dioxide and related products; (22) urea; (23) urea-ammonium nitrate. (3) Emissions to air from the production of the following inorganic chemicals: This may be covered by the BAT conclusions for the Production of Large Volume Inorganic Chemicals (LVIC). (4) Emissions to air from steam reforming as well as from the physical purification and reconcentration of spent sulphuric acid, provided that these processes are directly associated with a production process listed under the aforementioned points 2 or 3. (5) Emissions to air from the production of magnesium oxide using the dry process route. This may be covered by the BAT conclusions for the Production of Cement, Lime and Magnesium Oxide (CLM). (1) Combustion units other than process furnaces/heaters. This may be covered by the BAT conclusions for Large Combustion Plants (LCP), the BAT conclusions for the Refining of Mineral Oil and Gas (REF) and/or by Directive (EU) 2015/2193 of the European Parliament and of the Council. (2) Process furnaces/heaters with a total rated thermal input below 1 MW. (3) Process furnaces/heaters used in lower olefins, ethylene dichloride and/or vinyl chloride monomer production referred to in point 2 above. This is covered by the BAT conclusions for the production of Large Volume Organic Chemicals (LVOC). (6) Emissions to air from the following: (7) Emissions to air from waste incineration plants. This may be covered by the BAT conclusions for Waste Incineration (WI). (8) Emissions to air from the storage, transfer and handling of liquids, liquefied gases and solids, where these are not directly associated with the activity specified in Annex I to Directive 2010/75/EU: 4. Chemical industry. This may be covered by the BAT conclusions for Emissions from Storage (EFS). However, emissions to air from the storage, transfer and handling of liquids, liquefied gases and solids are included in the scope of these BAT conclusions provided that these processes are directly associated with the chemical production process specified in the scope of these BAT conclusions. (9) Emissions to air from indirect cooling systems. This may be covered by the BAT conclusions for Industrial Cooling Systems (ICS). (10) Production of Chlor-alkali (CAK); (11) Manufacture of Large Volume Inorganic Chemicals – Ammonia, Acids and Fertilisers (LVIC-AAF); (12) Manufacture of Large Volume Inorganic Chemicals – Solids and Others Industry (LVIC-S); (13) Production of Large Volume Organic Chemicals (LVOC); (14) Manufacture of Organic Fine Chemicals (OFC); (15) Production of Polymers (POL); (16) Production of Speciality Inorganic Chemicals (SIC); (17) Refining of Mineral Oil and Gas (REF); (18) Economics and Cross-media Effects (ECM); (19) Emissions from Storage (EFS); (20) Energy Efficiency (ENE); (21) Industrial Cooling Systems (ICS); (22) Large Combustion Plants (LCP); (23) Monitoring of Emissions to Air and Water from IED installations (ROM); (24) Waste Incineration (WI); (25) Waste Treatment (WT).
1. Emissions to air from the production of chlorine, hydrogen, and sodium/potassium hydroxide by the electrolysis of brine. This is covered by the BAT conclusions for the Production of Chlor-alkali (CAK).
2. Channelled emissions to air from the production of the following chemicals in continuous processes where the total production capacity of those chemicals exceeds 20 kt/yr: This is covered by the BAT conclusions for the Production of Large Volume Organic Chemicals (LVOC). However, channelled emissions to air of nitrogen oxides (NOX) and carbon monoxide (CO) from thermal treatment of waste gases originating from the aforementioned production processes are included in the scope of these BAT conclusions. (1) lower olefins using the steam cracking process; (2) formaldehyde; (3) ethylene oxide and ethylene glycols; (4) phenol from cumene; (5) dinitrotoluene from toluene, toluene diamine from dinitrotoluene, toluene diisocyanate from toluene diamine, methylene diphenyl diamine from aniline, methylene diphenyl diisocyanate from methylene diphenyl diamine; (6) ethylene dichloride (EDC) and vinyl chloride monomer (VCM); (7) hydrogen peroxide.
lower olefins using the steam cracking process;
formaldehyde;
ethylene oxide and ethylene glycols;
phenol from cumene;
dinitrotoluene from toluene, toluene diamine from dinitrotoluene, toluene diisocyanate from toluene diamine, methylene diphenyl diamine from aniline, methylene diphenyl diisocyanate from methylene diphenyl diamine;
ethylene dichloride (EDC) and vinyl chloride monomer (VCM);
hydrogen peroxide.
3. Emissions to air from the production of the following inorganic chemicals: This may be covered by the BAT conclusions for the Production of Large Volume Inorganic Chemicals (LVIC). (1) ammonia; (2) ammonium nitrate; (3) calcium ammonium nitrate; (4) calcium carbide; (5) calcium chloride; (6) calcium nitrate; (7) carbon black; (8) ferrous chloride; (9) ferrous sulphate (i.e. copperas and related products, such as chloro-sulphates); (10) hydrofluoric acid; (11) inorganic phosphates; (12) nitric acid; (13) nitrogen-, phosphorus- or potassium-based fertilisers (simple or compound fertilisers); (14) phosphoric acid; (15) precipitated calcium carbonate; (16) sodium carbonate (i.e. soda ash); (17) sodium chlorate; (18) sodium silicate; (19) sulphuric acid; (20) synthetic amorphous silica; (21) titanium dioxide and related products; (22) urea; (23) urea-ammonium nitrate.
ammonia;
ammonium nitrate;
calcium ammonium nitrate;
calcium carbide;
calcium chloride;
calcium nitrate;
carbon black;
ferrous chloride;
ferrous sulphate (i.e. copperas and related products, such as chloro-sulphates);
hydrofluoric acid;
inorganic phosphates;
nitric acid;
nitrogen-, phosphorus- or potassium-based fertilisers (simple or compound fertilisers);
phosphoric acid;
precipitated calcium carbonate;
sodium carbonate (i.e. soda ash);
sodium chlorate;
sodium silicate;
sulphuric acid;
synthetic amorphous silica;
titanium dioxide and related products;
urea;
urea-ammonium nitrate.
4. Emissions to air from steam reforming as well as from the physical purification and reconcentration of spent sulphuric acid, provided that these processes are directly associated with a production process listed under the aforementioned points 2 or 3.
5. Emissions to air from the production of magnesium oxide using the dry process route. This may be covered by the BAT conclusions for the Production of Cement, Lime and Magnesium Oxide (CLM).
6. Emissions to air from the following: (1) Combustion units other than process furnaces/heaters. This may be covered by the BAT conclusions for Large Combustion Plants (LCP), the BAT conclusions for the Refining of Mineral Oil and Gas (REF) and/or by Directive (EU) 2015/2193 of the European Parliament and of the Council. (2) Process furnaces/heaters with a total rated thermal input below 1 MW. (3) Process furnaces/heaters used in lower olefins, ethylene dichloride and/or vinyl chloride monomer production referred to in point 2 above. This is covered by the BAT conclusions for the production of Large Volume Organic Chemicals (LVOC).
Combustion units other than process furnaces/heaters. This may be covered by the BAT conclusions for Large Combustion Plants (LCP), the BAT conclusions for the Refining of Mineral Oil and Gas (REF) and/or by Directive (EU) 2015/2193 of the European Parliament and of the Council.
Process furnaces/heaters with a total rated thermal input below 1 MW.
Process furnaces/heaters used in lower olefins, ethylene dichloride and/or vinyl chloride monomer production referred to in point 2 above. This is covered by the BAT conclusions for the production of Large Volume Organic Chemicals (LVOC).
7. Emissions to air from waste incineration plants. This may be covered by the BAT conclusions for Waste Incineration (WI).
8. Emissions to air from the storage, transfer and handling of liquids, liquefied gases and solids, where these are not directly associated with the activity specified in Annex I to Directive 2010/75/EU: 4. Chemical industry. This may be covered by the BAT conclusions for Emissions from Storage (EFS). However, emissions to air from the storage, transfer and handling of liquids, liquefied gases and solids are included in the scope of these BAT conclusions provided that these processes are directly associated with the chemical production process specified in the scope of these BAT conclusions.
9. Emissions to air from indirect cooling systems. This may be covered by the BAT conclusions for Industrial Cooling Systems (ICS).
Production of Chlor-alkali (CAK);
Manufacture of Large Volume Inorganic Chemicals – Ammonia, Acids and Fertilisers (LVIC-AAF);
Manufacture of Large Volume Inorganic Chemicals – Solids and Others Industry (LVIC-S);
Production of Large Volume Organic Chemicals (LVOC);
Manufacture of Organic Fine Chemicals (OFC);
Production of Polymers (POL);
Production of Speciality Inorganic Chemicals (SIC);
Refining of Mineral Oil and Gas (REF);
Economics and Cross-media Effects (ECM);
Emissions from Storage (EFS);
Energy Efficiency (ENE);
Industrial Cooling Systems (ICS);
Large Combustion Plants (LCP);
Monitoring of Emissions to Air and Water from IED installations (ROM);
Waste Incineration (WI);
Waste Treatment (WT).
DEFINITIONS
For the purposes of these BAT conclusions, the following definitions apply: General terms Term used Definition Channelled emissions to air Emissions of pollutants to air through an emission point such as a stack. Combustion unit Any technical apparatus in which fuels are oxidised in order to use the heat thus generated. Combustion units include boilers, engines, turbines and process furnaces/heaters, but do not include thermal or catalytic oxidisers. Complex inorganic pigments A stable crystal lattice of different metal cations. The most important host-lattices are rutile, spinel, zircon, and haematite/corundum, but other stable structures exist. Continuous measurement Measurement using an automated measuring system permanently installed on site. Continuous process A process in which the raw materials are fed continuously into the reactor with the reaction products then fed into connected downstream separation and/or recovery units. Diffuse emissions Non-channelled emissions to air. Diffuse emissions include fugitive and non-fugitive emissions. Emissions to air Generic term for emissions of pollutants to air including both channelled and diffuse emissions. Ethanolamines Collective term for monoethanolamine, diethanolamine and triethanolamine, or mixtures thereof. Ethylene glycols Collective term for monoethylene glycol, diethylene glycol and triethylene glycol, or mixtures thereof. Existing plant A plant that is not a new plant. Existing process furnace/heater A process furnace/heater that is not a new process furnace/heater. Flue-gas The exhaust gas exiting a combustion unit. Fugitive emissions Non-channelled emissions to air caused by loss of tightness of equipment which is designed or assembled to be tight. Fugitive emissions can arise from: Lower olefins Collective term for ethylene, propylene, butylene and butadiene, or mixtures thereof. Major plant upgrade A major change in the design or technology of a plant with major adjustments or replacements of the process and/or abatement units and associated equipment. Mass flow The mass of a given substance or parameter which is emitted over a defined period of time. New plant A plant first permitted on the site of the installation following the publication of these BAT conclusions or a complete replacement of a plant following the publication of these BAT conclusions. New process furnace/heater A process furnace/heater in a plant first permitted following the publication of these BAT conclusions or a complete replacement of a process furnace/heater following the publication of these BAT conclusions. Non-fugitive emissions Diffuse emissions other than fugitive emissions. Non-fugitive emissions may arise from, for example, atmospheric vents, bulk storage, loading/unloading systems, vessels and tanks (on opening), open gutters, sampling systems, tank venting, waste, sewers and water treatment plants. NOX precursors Nitrogen-containing compounds (e.g. acrylonitrile, ammonia, nitrous gases, nitrogen-containing organic compounds) in the input to thermal or catalytic oxidation that lead to NOX emissions. Elemental nitrogen is not included. Operational constraint Limitation or restriction connected, for example, to: Periodic measurement Measurement at specified time intervals using manual or automated methods. Polymer grade For each type of polymer, there are different product qualities (i.e. grades) which vary in structure and molecular mass, and are optimised for specific applications. In the case of polyolefins, these may vary regarding the use of co-polymers such as EVA. In the case of PVC, they may vary in the average length of the polymer chain and in the porosity of the particles. Process furnace/heater Process furnaces or heaters are: As a consequence of the application of good energy recovery practices, some of the process furnaces/heaters may have an associated steam/electricity generation system. This is an integral design feature of the process furnace/heater that cannot be considered in isolation. Process off-gas The gas leaving a process which is further treated for recovery and/or abatement. Solvent Organic solvent as defined in Article 3(46) of Directive 2010/75/EU. Solvent consumption Consumption of solvent as defined in Article 57(9) of Directive 2010/75/EU. Solvent input The total quantity of organic solvents used as defined in Part 7 of Annex VII to Directive 2010/75/EU. Solvent mass balance A mass balance exercise conducted at least on an annual basis according to Part 7 of Annex VII to Directive 2010/75/EU. Thermal treatment Treatment of waste gases using thermal or catalytic oxidation. Total emissions The sum of channelled and diffuse emissions. Valid hourly (or half-hourly) average An hourly (or half-hourly) average is considered valid when there is no maintenance or malfunction of the automated measuring system. Substances/Parameters Term used Definition Cl2 Elemental chlorine. CO Carbon monoxide. CS2 Carbon disulphide. Dust Total particulate matter (in air). Unless specified otherwise, dust includes PM2,5 and PM10. EDC Ethylene dichloride (1,2-Dichloroethane). HCl Hydrogen chloride. HCN Hydrogen cyanide. HF Hydrogen fluoride. H2S Hydrogen sulphide. NH3 Ammonia. Ni Nickel. N2O Dinitrogen oxide (also referred to as nitrous oxide). NOX The sum of nitrogen monoxide (NO) and nitrogen dioxide (NO2), expressed as NO2. Pb Lead. PCDD/F Polychlorinated dibenzo-p-dioxins and -furans. PM2,5 Particulate matter which passes through a size-selective inlet with a 50 % efficiency cut-off at 2,5 μm aerodynamic diameter as defined in Directive 2008/50/EC of the European Parliament and of the Council. PM10 Particulate matter which passes through a size-selective inlet with a 50 % efficiency cut-off at 10 μm aerodynamic diameter as defined in Directive 2008/50/EC. SO2 Sulphur dioxide. SOX The sum of sulphur dioxide (SO2), sulphur trioxide (SO3), and sulphuric acid aerosols, expressed as SO2. TVOC Total volatile organic carbon, expressed as C. VCM Vinyl chloride monomer. VOC Volatile organic compound as defined in Article 3(45) of Directive 2010/75/EU. (1) moving equipment, such as agitators, compressors, pumps, valves (manual and automatic); (2) static equipment, such as flanges and other connections, open-ended lines, sampling points. (3) substances used (e.g. substances that cannot be substituted, very corrosive substances); (4) operating conditions (e.g. very high temperature or pressure); (5) the functioning of the plant; (6) resource availability (e.g. availability of spare parts when replacing a piece of equipment, availability of qualified manpower); (7) expected environmental benefits (e.g. giving priority to maintenance, repair or replacement actions with the highest environmental benefit). (8) combustion units used for the treatment of objects or feed material through direct contact, e.g. in drying processes or chemical reactors; or (9) combustion units whose radiant and/or conductive heat is transferred to objects or feed material through a solid wall without using an intermediary heat transfer fluid, e.g. furnaces or reactors heating a process stream used in the (petro-)chemical industry.
moving equipment, such as agitators, compressors, pumps, valves (manual and automatic);
static equipment, such as flanges and other connections, open-ended lines, sampling points.
substances used (e.g. substances that cannot be substituted, very corrosive substances);
operating conditions (e.g. very high temperature or pressure);
the functioning of the plant;
resource availability (e.g. availability of spare parts when replacing a piece of equipment, availability of qualified manpower);
expected environmental benefits (e.g. giving priority to maintenance, repair or replacement actions with the highest environmental benefit).
combustion units used for the treatment of objects or feed material through direct contact, e.g. in drying processes or chemical reactors; or
combustion units whose radiant and/or conductive heat is transferred to objects or feed material through a solid wall without using an intermediary heat transfer fluid, e.g. furnaces or reactors heating a process stream used in the (petro-)chemical industry.
ACRONYMS
For the purposes of these BAT conclusions, the following acronyms apply: Acronym Definition CLP Regulation (EC) No 1272/2008 of the European Parliament and of the Council on classification, labelling and packaging of substances and mixtures. CMR Carcinogenic, mutagenic or toxic for reproduction. CMR 1A CMR substance of category 1A as defined in Regulation (EC) No 1272/2008 as amended, i.e. carrying the hazard statements H340, H350, H360. CMR 1B CMR substance of category 1B as defined in Regulation (EC) No 1272/2008 as amended, i.e. carrying the hazard statements H340, H350, H360. CMR 2 CMR substance of category 2 as defined in Regulation (EC) No 1272/2008 as amended, i.e. carrying the hazard statements H341, H351, H361. DIAL Differential absorption LIDAR. EMS Environmental Management System. EPS Expandable polystyrene. E-PVC PVC produced by emulsion polymerisation. EVA Ethylene-vinyl acetate. GPPS General-purpose polystyrene. HDPE High-density polyethylene. HEAF High-efficiency air filter. HEPA High-efficiency particle air. HIPS High-impact polystyrene. IED Directive 2010/75/EU on industrial emissions. I-TEQ International toxic equivalent – derived by using the equivalence factors in Part 2 of Annex VI to Directive 2010/75/EU. LDAR Leak detection and repair. LDPE Low-density polyethylene. LIDAR Light detection and ranging. LLDPE Linear low-density polyethylene. OGI Optical gas imaging. OTNOC Other than normal operating conditions. PP Polypropylene. PVC Polyvinyl chloride. REACH Regulation (EC) No 1907/2006 of the European Parliament and of the Council concerning the registration, evaluation, authorisation and restriction of chemicals. SCR Selective catalytic reduction. SNCR Selective non-catalytic reduction. SOF Solar occultation flux. S-PVC PVC produced by suspension polymerisation. ULPA Ultra-low penetration air.
GENERAL CONSIDERATIONS
Best Available Techniques
The techniques listed and described in these BAT conclusions are neither prescriptive nor exhaustive. Other techniques may be used that ensure at least an equivalent level of environmental protection. Unless otherwise stated, the BAT conclusions are generally applicable.
Emission levels associated with the best available techniques (BAT-AELs) and indicative emission levels for channelled emissions to air
The BAT-AELs and the indicative emission levels for channelled emissions to air given in these BAT conclusions refer to values of concentration, expressed as mass of emitted substance per volume of waste gas under standard conditions (dry gas at a temperature of 273,15 K, and a pressure of 101,3 kPa) and expressed in the unit mg/Nm3, μg/Nm3 or ng I-TEQ/Nm3. The reference oxygen levels used to express BAT-AELs and indicative emission levels in these BAT conclusions are shown in the table below. Source of emissions Reference oxygen level (OR) Process furnace/heater using indirect heating 3 dry vol-% All other sources No correction for the oxygen level For the cases where a reference oxygen level is given, the equation for calculating the emission concentration at the reference oxygen level is: ER21OR21OMEM where: ER emission concentration at the reference oxygen level OR; OR reference oxygen level in vol-%; EM measured emission concentration; OM measured oxygen level in vol-%. The equation above does not apply if the process furnace(s)/heater(s) use(s) oxygen-enriched air or pure oxygen or when additional air intake for safety reasons brings the oxygen level in the waste gas very close to 21 vol-%. In this case, the emission concentration at the reference oxygen level of 3 dry vol-% is calculated differently. For averaging periods of BAT-AELs and indicative emission levels for channelled emissions to air, the following definitions apply. Type of measurement Averaging period Definition Continuous Daily average Average over a period of 1 day based on valid hourly or half-hourly averages. Periodic Average over the sampling period Average value of three consecutive samplings/measurements of at least 30 minutes each. For the purpose of calculating the mass flows in relation to BAT 11 (Table 1.1), BAT 14 (Table 1.3), BAT 18 (Table 1.6), BAT 29 (Table 1.9) and BAT 36 (Table 1.15), where waste gases with similar characteristics, e.g. containing the same (type of) substances/parameters, and discharged through two or more separate stacks could, in the judgement of the competent authority, be discharged through a common stack, these stacks shall be considered as a single stack.
BAT-AELs for diffuse VOC emissions to air
For diffuse VOC emissions from the use of solvents or the reuse of recovered solvents, the BAT-AELs in these BAT conclusions are given as a percentage of the solvent input, calculated on an annual basis according to Part 7 of Annex VII to Directive 2010/75/EU.
BAT-AELs for total emissions to air for the production of polymers or synthetic rubbers Production of polyolefins or synthetic rubbers
For total emissions to air of VOCs from the production of polyolefins or synthetic rubbers, the BAT-AELs in these BAT conclusions are given as specific emission loads calculated on an annual basis by dividing the total VOC emissions by a sector-dependent production rate, expressed in the unit g C/kg of product.
Production of PVC
For total emissions to air of VCM from the production of PVC, the BAT-AELs in these BAT conclusions are given as specific emission loads calculated on an annual basis by dividing the total VCM emissions by a sector-dependent production rate, expressed in the unit g/kg of product. For the purpose of calculating specific emission loads, total emissions include the VCM concentration in the PVC.
Production of viscose
For the production of viscose, the BAT-AEL in these BAT conclusions is given as a specific emission load calculated on an annual basis by dividing the total S emissions by the production rate of staple fibres or casing, expressed in the unit g S/kg of product.
1.1. General BAT conclusions (i) commitment, leadership, and accountability of the management, including senior management, for the implementation of an effective EMS; (ii) an analysis that includes the determination of the organisation’s context, the identification of the needs and expectations of interested parties, the identification of characteristics of the installation that are associated with possible risks for the environment (or human health) as well as of the applicable legal requirements relating to the environment; (iii) development of an environmental policy that includes the continuous improvement of the environmental performance of the installation; (iv) establishing objectives and performance indicators in relation to significant environmental aspects, including safeguarding compliance with applicable legal requirements; (v) planning and implementing the necessary procedures and actions (including corrective and preventive actions where needed), to achieve the environmental objectives and avoid environmental risks; (vi) determination of structures, roles and responsibilities in relation to environmental aspects and objectives and provision of the financial and human resources needed; (vii) ensuring the necessary competence and awareness of staff whose work may affect the environmental performance of the installation (e.g. by providing information and training); (viii) internal and external communication; (ix) fostering employee involvement in good environmental management practices; (x) establishing and maintaining a management manual and written procedures to control activities with significant environmental impact as well as relevant records; (xi) effective operational planning and process control; (xii) implementation of appropriate maintenance programmes; (xiii) emergency preparedness and response protocols, including the prevention and/or mitigation of the adverse (environmental) impacts of emergency situations; (xiv) when (re)designing a (new) installation or a part thereof, consideration of its environmental impacts throughout its life, which includes construction, maintenance, operation and decommissioning; (xv) implementation of a monitoring and measurement programme; if necessary, information can be found in the Reference Report on Monitoring of Emissions to Air and Water from IED Installations; (xvi) application of sectoral benchmarking on a regular basis; (xvii) periodic independent (as far as practicable) internal auditing and periodic independent external auditing in order to assess the environmental performance and to determine whether or not the EMS conforms to planned arrangements and has been properly implemented and maintained; (xviii) evaluation of causes of nonconformities, implementation of corrective actions in response to nonconformities, review of the effectiveness of corrective actions, and determination of whether similar nonconformities exist or could potentially occur; (xix) periodic review, by senior management, of the EMS and its continuing suitability, adequacy and effectiveness; (xx) following and taking into account the development of cleaner techniques. (xxi) an inventory of channelled and diffuse emissions to air (see BAT 2); (xxii) an OTNOC management plan for emissions to air (see BAT 3); (xxiii) an integrated waste gas management and treatment strategy for channelled emissions to air (see BAT 4); (xxiv) a management system for diffuse VOC emissions to air (see BAT 19); (xxv) a chemicals management system that includes an inventory of the hazardous substances and substances of very high concern used in the process(es); the potential for substitution of the substances that are listed in this inventory, focusing on those substances other than raw materials, is analysed periodically (e.g. annually) in order to identify possible new available and safer alternatives, with no or lower environmental impacts. Grp. note. Regulation (EC) No 1221/2009 of the European Parliament and of the Council establishes the European Union eco-management and audit scheme (EMAS), which is an example of an EMS consistent with this BAT. Grp. applicability. The level of detail and the degree of formalisation of the EMS will generally be related to the nature, scale and complexity of the installation, and the range of environmental impacts it may have. Grp. 1. In order to improve the overall environmental performance, BAT is to elaborate and implement an environmental management system (EMS) that incorporates all of the following features: Specifically for the chemical sector, BAT is also to incorporate the following features in the EMS: (a) chemical reaction equations, also showing side products; (b) simplified process flow sheets that show the origin of the emissions; (i) information, as comprehensive as is reasonably possible, about the chemical production process(es), including: (a) emission point(s); (b) average values and variability of flow and temperature; (c) average concentration and mass flow values of relevant substances/parameters and their variability (e.g. TVOC, CO, NOX, SOX, Cl2, HCl); (d) presence of other substances that may affect the waste gas treatment system(s) or plant safety (e.g. oxygen, nitrogen, water vapour, dust); (e) techniques used to prevent and/or reduce channelled emissions to air; (f) flammability, lower and higher explosive limits, reactivity; (g) monitoring methods (see BAT 8); (h) presence of substances classified as CMR 1A, CMR 1B or CMR 2; the presence of such substances may for example be assessed according to the criteria of Regulation (EC) No 1272/2008 on classification, labelling and packaging (CLP). (ii) information, as comprehensive as is reasonably possible, about channelled emissions to air, such as: (a) identification of the emission source(s); (b) characteristics of each emission source (e.g. fugitive or non-fugitive; static or moving; accessibility of the emission source; included in an LDAR programme or not); (1) physical state; (2) vapour pressure of the substance(s) in the liquid, pressure of the gas; (3) temperature; (4) composition (by weight for liquids or by volume for gases); (5) hazardous properties of the substance(s) or mixtures, including substances or mixtures classified as CMR 1A, CMR 1B or CMR 2; (c) the characteristics of the gas or liquid in contact with the emission source(s), including: (d) techniques used to prevent and/or reduce diffuse emissions to air; (e) monitoring (see BAT 20, BAT 21 and BAT 22). (iii) information, as comprehensive as is reasonably possible, about diffuse emissions to air, such as: Grp_for_diffuse. emissions. The information about diffuse emissions to air is particularly relevant for activities using large amounts of organic substances or mixtures (e.g. production of pharmaceuticals, production of large volumes of organic chemicals or of polymers). The information about fugitive emissions covers all emission sources in contact with organic substances with a vapour pressure greater than 0,3 kPa at 293,15 K. Sources of fugitive emissions connected to pipes whose diameter is small (e.g. smaller than 12,7 mm, i.e. 0,5 inch) may be excluded from the inventory. Equipment operated under subatmospheric pressure may be excluded from the inventory. Grp. applicability. The level of detail and the degree of formalisation of the inventory will generally be related to the nature, scale and complexity of the installation, and the range of environmental impacts it may have. Grp. 2. In order to facilitate the reduction of emissions to air, BAT is to establish, maintain and regularly review (including when a substantial change occurs) an inventory of channelled and diffuse emissions to air, as part of the environmental management system (see BAT 1), that incorporates all of the following features: Grp. 111. Environmental management systems (i) identification of potential OTNOC (e.g. failure of equipment critical to the control of channelled emissions to air, or equipment critical to the prevention of accidents or incidents that could lead to emissions to air (critical equipment)), of their root causes and of their potential consequences; (ii) appropriate design of critical equipment (e.g. equipment modularity and compartmentalisation, backup systems, techniques to obviate the need to bypass waste gas treatment during start-up and shutdown, high-integrity equipment, etc.); (iii) set-up and implementation of a preventive maintenance plan for critical equipment (see BAT 1 xii.); (iv) monitoring (i.e. estimating or, where this is possible, measuring) and recording of emissions and associated circumstances during OTNOC; (v) periodic assessment of the emissions occurring during OTNOC (e.g. frequency of events, duration, amount of pollutants emitted as recorded in point iv.) and implementation of corrective actions if necessary; (vi) regular review and update of the list of identified OTNOC under point i. following the periodic assessment of point v.; (vii) regular testing of backup systems. Grp. 3. In order to reduce the frequency of the occurrence of OTNOC and to reduce emissions to air during OTNOC, BAT is to set up and implement a risk-based OTNOC management plan as part of the environmental management system (see BAT 1) that includes all of the following features: Grp. 112. Other than normal operating conditions (OTNOC) Grp. description. The integrated waste gas management and treatment strategy is based on the inventory in BAT 2. It takes into account factors such as greenhouse gas emissions and the consumption or reuse of energy, water and materials associated with the use of the different techniques. Grp. 4. In order to reduce channelled emissions to air, BAT is to use an integrated waste gas management and treatment strategy that includes, in order of priority, process-integrated recovery and abatement techniques. Grp. description. The combined treatment of waste gases with similar characteristics ensures more effective and efficient treatment compared to the separate treatment of individual waste gas streams. The combination of waste gases is carried out considering plant safety (e.g. avoiding concentrations close to the lower/upper explosive limit), technical (e.g. compatibility of the individual waste gas streams, concentration of the substances concerned), environmental (e.g. maximising recovery of materials or pollutant abatement) and economic factors (e.g. distance between different production units). Care is taken that the combination of waste gases does not lead to the dilution of emissions. Grp. 5. In order to facilitate the recovery of materials and the reduction of channelled emissions to air, as well as to increase energy efficiency, BAT is to combine waste gas streams with similar characteristics, thus minimising the number of emission points. Grp. 6. In order to reduce channelled emissions to air, BAT is to ensure that the waste gas treatment systems are appropriately designed (e.g. considering the maximum flow rate and pollutant concentrations), operated within their design ranges, and maintained (through preventive, corrective, regular and unplanned maintenance) so as to ensure optimal availability, effectiveness and efficiency of the equipment. Grp. 1131. General techniques Grp. 7. BAT is to continuously monitor key process parameters (e.g. waste gas flow and temperature) of waste gas streams being sent to pretreatment and/or final treatment. Grp. 8. BAT is to monitor channelled emissions to air with at least the frequency given below and in accordance with EN standards. If EN standards are not available, BAT is to use ISO, national or other international standards that ensure the provision of data of an equivalent scientific quality. Substance/Parameter Process(es)/Source(s) Emission points Standard(s) Minimum monitoring frequency Monitoring associated with Ammonia (NH3) Use of SCR/SNCR Any stack EN 21877 Once every 6 months BAT 17 All other processes/sources BAT 18 Benzene All processes/sources Any stack No EN standard available Once every 6 months BAT 11 1,3-Butadiene All processes/sources Any stack No EN standard available Once every 6 months BAT 11 Carbon monoxide (CO) Thermal treatment Any stack with a CO mass flow of ≥ 2 kg/h Generic EN standards Continuous BAT 16 Any stack with a CO mass flow of < 2 kg/h EN 15058 Once every 6 months Process furnaces/heaters Any stack with a CO mass flow of ≥ 2 kg/h Generic EN standards Continuous BAT 36 Any stack with a CO mass flow of < 2 kg/h EN 15058 Once every 6 months All other processes/sources Any stack with a CO mass flow of ≥ 2 kg/h Generic EN standards Continuous BAT 18 Any stack with a CO mass flow of < 2 kg/h EN 15058 Once every year Chloromethane All processes/sources Any stack No EN standard available Once every 6 months BAT 11 CMR substances other than CMR substances covered elsewhere in this table All other processes/sources Any stack No EN standard available Once every 6 months BAT 11 Dichloromethane All processes/sources Any stack No EN standard available Once every 6 months BAT 11 Dust All processes/sources Any stack with dust mass flow ≥ 3 kg/h Generic EN standards, EN 13284-1 and EN 13284-2 Continuous BAT 14 Any stack with dust mass flow < 3 kg/h EN 13284-1 Once every year Elemental chlorine (Cl2) All processes/sources Any stack No EN standard available Once every year BAT 18 Ethylene dichloride (EDC) All processes/sources Any stack No EN standard available Once every 6 months BAT 11 Ethylene oxide All processes/sources Any stack No EN standard available Once every 6 months BAT 11 Formaldehyde All processes/sources Any stack EN standard under development Once every 6 months BAT 11 Gaseous chlorides All processes/sources Any stack EN 1911 Once every year BAT 18 Gaseous fluorides All processes/sources Any stack No EN standard available Once every year BAT 18 Hydrogen cyanide (HCN) All processes/sources Any stack No EN standard available Once every year BAT 18 Lead and its compounds All processes/sources Any stack EN 14385 Once every 6 months BAT 14 Nickel and its compounds All processes/sources Any stack EN 14385 Once every 6 months BAT 14 Nitrous oxide (N2O) All processes/sources Any stack EN ISO 21258 Once every year – Nitrogen oxides (NOX) Thermal treatment Any stack with a NOX mass flow of ≥ 2,5 kg/h Generic EN standards Continuous BAT 16 Any stack with a NOX mass flow of < 2,5 kg/h EN 14792 Once every 6 months Process furnaces/heaters Any stack with a NOX mass flow of ≥ 2,5 kg/h Generic EN standards Continuous BAT 36 Any stack with a NOX mass flow of < 2,5 kg/h EN 14792 Once every 6 months All other processes/sources Any stack with a NOX mass flow of ≥ 2,5 kg/h Generic EN standards Continuous BAT 18 Any stack with a NOX mass flow of < 2,5 kg/h EN 14792 Once every 6 months PCDD/F Thermal treatment Any stack EN 1948-1, EN 1948-2, EN 1948-3 Once every 6 months BAT 12 PM2,5 and PM10 All processes/sources Any stack EN ISO 23210 Once every year BAT 14 Propylene oxide All processes/sources Any stack No EN standard available Once every 6 months BAT 11 Sulphur dioxide (SO2) Thermal treatment Any stack with a SO2 mass flow of ≥ 2,5 kg/h Generic EN standards Continuous BAT 16 Any stack with a SO2 mass flow of < 2,5 kg/h EN 14791 Once every 6 months Process furnaces/heaters Any stack with a SO2 mass flow of ≥ 2,5 kg/h Generic EN standards Continuous BAT 18, BAT 36 Any stack with a SO2 mass flow of < 2,5 kg/h EN 14791 Once every 6 months All other processes/sources Any stack with a SO2 mass flow of ≥ 2,5 kg/h Generic EN standards Continuous BAT 18 Any stack with a SO2 mass flow of < 2,5 kg/h EN 14791 Once every 6 months Tetrachloromethane All processes/sources Any stack No EN standard available Once every 6 months BAT 11 Toluene All processes/sources Any stack No EN standard available Once every 6 months BAT 11 Trichloromethane All processes/sources Any stack No EN standard available Once every 6 months BAT 11 Total volatile organic carbon (TVOC) Production of polyolefins Any stack with a TVOC mass flow of ≥ 2 kg C/h Generic EN standards Continuous BAT 11, BAT 25 Any stack with a TVOC mass flow of < 2 kg C/h EN 12619 Once every 6 months Production of synthetic rubbers Any stack with a TVOC mass flow of ≥ 2 kg C/h Generic EN standards Continuous BAT 11, BAT 32 Any stack with a TVOC mass flow of < 2 kg C/h EN 12619 Once every 6 months All other processes/sources Any stack with a TVOC mass flow of ≥ 2 kg C/h Generic EN standards Continuous BAT 11 Any stack with a TVOC mass flow of < 2 kg C/h EN 12619 Once every 6 months Grp. 1132. Monitoring Grp. applicability. Recovery may be restricted where the energy demand is excessive due to the low concentration of the compound(s) concerned in the process off-gas(es). Reuse may be restricted due to product quality specifications. Grp. 9. In order to increase resource efficiency and to reduce the mass flow of organic compounds sent to the final waste gas treatment, BAT is to recover organic compounds from process off-gases by using one or a combination of the techniques given below and to reuse them. Technique Description a. Absorption (regenerative) See Section 1.4.1. b. Adsorption (regenerative) See Section 1.4.1. c. Condensation See Section 1.4.1. Grp. description. Process off-gases with a high calorific value are burnt as a fuel in a combustion unit (gas engine, boiler, process heater or furnace) and the heat is recovered as steam or for electricity generation, or to provide heat to the process. For process off-gases with low VOC concentrations (e.g. < 1 g/Nm3), pre-concentration steps may be applied using adsorption (rotor or fixed bed, with activated carbon or zeolites), in order to increase the calorific value of the process off-gases. Molecular sieves (smoothers), typically composed of zeolites, may be used to level down high variations (e.g. concentration peaks) of VOC concentrations in the process off-gases. Grp. applicability. Sending process off-gases to a combustion unit may be restricted due to the presence of contaminants or due to safety considerations. Grp. 10. In order to increase energy efficiency and to reduce the mass flow of organic compounds sent to the final waste gas treatment, BAT is to send process off-gases with a sufficient calorific value to a combustion unit that is, if technically possible, combined with heat recovery. BAT 9 has priority over sending process off-gases to a combustion unit. Grp_11_table. 11. In order to reduce channelled emissions to air of organic compounds, BAT is to use one or a combination of the techniques given below. Technique Description Applicability a. Adsorption See Section 1.4.1. Generally applicable. b. Absorption See Section 1.4.1. Generally applicable. c. Catalytic oxidation See Section 1.4.1. Applicability may be restricted by the presence of catalyst poisons in the waste gases. d. Condensation See Section 1.4.1. Generally applicable. e. Thermal oxidation See Section 1.4.1. Applicability of recuperative and regenerative thermal oxidation to existing plants may be restricted by design and/or operational constraints. Applicability may be restricted where the energy demand is excessive due to the low concentration of the compound(s) concerned in the process off-gases. f. Bioprocesses See Section 1.4.1. Only applicable to the treatment of biodegradable compounds. Substance/Parameter BAT-AEL (mg/Nm3) (Daily average or average over the sampling period) Total volatile organic carbon (TVOC) < 1-20 Sum of VOCs classified as CMR 1A or 1B < 1-5 Sum of VOCs classified as CMR 2 < 1-10 Benzene < 0,5-1 1,3-Butadiene < 0,5-1 Ethylene dichloride < 0,5-1 Ethylene oxide < 0,5-1 Propylene oxide < 0,5-1 Formaldehyde 1-5 Chloromethane < 0,5-1 Dichloromethane < 0,5-1 Tetrachloromethane < 0,5-1 Toluene < 0,5-1 Trichloromethane < 0,5-1 The associated monitoring is given in BAT 8. Grp_12_table. 12. In order to reduce channelled emissions to air of PCDD/F from thermal treatment of waste gases containing chlorine and/or chlorinated compounds, BAT is to use techniques a. and b., and one or a combination of techniques c. to e., given below. Technique Description Applicability Specific techniques to reduce PCDD/F emissions a. Optimised catalytic or thermal oxidation See Section 1.4.1. Generally applicable. b. Rapid waste-gas cooling Rapid cooling of waste gases from temperatures above 400 °C to below 250 °C to prevent the de novo synthesis of PCDD/F. Generally applicable. c. Adsorption using activated carbon See Section 1.4.1. Generally applicable. d. Absorption See Section 1.4.1. Generally applicable. Other techniques not primarily used to reduce PCDD/F emissions e. Selective catalytic reduction (SCR) See Section 1.4.1. When SCR is used for NOX abatement, an adequate catalyst surface of the SCR system also provides for the partial reduction of the emissions of PCDD/F. Applicability to existing plants may be restricted by space availability and/or by the presence of catalyst poisons in the waste gases. Substance/Parameter BAT-AEL (ng I-TEQ/Nm3) (Average over the sampling period) PCDD/F < 0,01-0,05 The associated monitoring is given in BAT 8. Grp. 1133. Organic compounds Grp. applicability. Recovery may be restricted where the energy demand for dust purification or decontamination is excessive. Reuse may be restricted due to product quality specifications. Grp. 13. In order to increase resource efficiency and to reduce the mass flow of dust and particulate-bound metals sent to the final waste gas treatment, BAT is to recover materials from process off-gases by using one or a combination of the techniques given below and to reuse them. Technique Description a. Cyclone See Section 1.4.1. b. Fabric filter See Section 1.4.1. c. Absorption See Section 1.4.1. Grp_14_table. 13. In order to reduce channelled emissions to air of dust and particulate-bound metals, BAT is to use one or a combination of the techniques given below. Technique Description Applicability a. Absolute filter See Section 1.4.1. Applicability may be limited in the case of sticky dust or when the temperature of the waste gases is below the dew point. b. Absorption See Section 1.4.1. Generally applicable. c. Fabric filter See Section 1.4.1. Applicability may be limited in the case of sticky dust or when the temperature of the waste gases is below the dew point. d. High-efficiency air filter See Section 1.4.1. Generally applicable. e. Cyclone See Section 1.4.1. Generally applicable. f. Electrostatic precipitator See Section 1.4.1. Generally applicable. Substance/Parameter BAT-AEL (mg/Nm3) (Daily average or average over the sampling period) Dust < 1-5 Lead and its compounds, expressed as Pb < 0,01-0,1 Nickel and its compounds, expressed as Ni < 0,02-0,1 The associated monitoring is given in BAT 8. Grp. 1134. Dust (including PM10 and PM2,5) and particulate-bound metals Grp. description. See Section 1.4.1. Grp. applicability. Recovery may be restricted where the energy demand is excessive due to the low concentration of the compound(s) concerned in the process off-gas(es). Reuse may be restricted due to product quality specifications. Grp. 15. In order to increase resource efficiency and to reduce the mass flow of inorganic compounds sent to the final waste gas treatment, BAT is to recover inorganic compounds from process off-gases by using absorption and to reuse them. Grp_16_table. 14. In order to reduce channelled emissions to air of CO, NOX and SOX from thermal treatment, BAT is to use technique c. and one or a combination of the other techniques given below. Technique Description Main inorganic compounds targeted Applicability a. Choice of fuel See Section 1.4.1. NOX, SOX Generally applicable. b. Low-NOX burner See Section 1.4.1. NOX Applicability to existing plants may be restricted by design and/or operational constraints. c. Optimisation of catalytic or thermal oxidation See Section 1.4.1. CO, NOX Generally applicable. d. Removal of high levels of NOX precursors Remove (if possible, for reuse) high levels of NOX precursors prior to thermal or catalytic oxidation, e.g. by absorption, adsorption or condensation. NOX Generally applicable. e. Absorption See Section 1.4.1. SOX Generally applicable. f. Selective catalytic reduction (SCR) See Section 1.4.1. NOX Applicability to existing plants may be restricted by space availability. g. Selective non-catalytic reduction (SNCR) See Section 1.4.1. NOX Applicability to existing plants may be restricted by the residence time needed for the reaction. Substance/Parameter BAT-AEL (mg/Nm3) (Daily average or average over the sampling period) Nitrogen oxides (NOX) from catalytic oxidation 5-30 Nitrogen oxides (NOX) from thermal oxidation 5-130 Carbon monoxide (CO) No BAT-AEL The associated monitoring is given in BAT 8. The BAT-AEL for channelled emissions to air of SO2 is given in Table 1.6. Grp_17_table. 15. In order to reduce channelled emissions to air of ammonia from the use of selective catalytic reduction (SCR) or selective non-catalytic reduction (SNCR) for the abatement of NOX emissions (ammonia slip), BAT is to optimise the design and/or operation of SCR or SNCR (e.g. optimised reagent to NOX ratio, homogeneous reagent distribution and optimum size of the reagent drops). Substance/Parameter BAT-AEL (mg/Nm3) (Average over the sampling period) Ammonia (NH3) from SCR/SNCR < 0,5-8 The associated monitoring is given in BAT 8. Grp_18_table. 16. In order to reduce channelled emissions to air of inorganic compounds other than channelled emissions to air of ammonia from the use of selective catalytic reduction (SCR) or selective non-catalytic reduction (SNCR) for the abatement of NOX emissions), channelled emissions to air of CO, NOX and SOX from the use of thermal treatment, and channelled emissions to air of NOX from process furnaces/heaters, BAT is to use one or a combination of the techniques given below. Technique Description Main inorganic compounds targeted Applicability Specific techniques to reduce emissions to air of inorganic compounds a. Absorption See Section 1.4.1. Cl2, HCl, HCN, HF, NH3, NOX, SOX Generally applicable. b. Adsorption See Section 1.4.1. For the removal of inorganic substances, the technique is often used in combination with a dust abatement technique (see BAT 14). HCl, HF, NH3, SOX Generally applicable. c. Selective catalytic reduction (SCR) See Section 1.4.1. NOX Applicability to existing plants may be restricted by space availability. d. Selective non-catalytic reduction (SNCR) See Section 1.4.1. NOX Applicability to existing plants may be restricted by the residence time needed for the reaction. Other techniques not primarily used to reduce emissions to air of inorganic compounds e. Catalytic oxidation See Section 1.4.1. NH3 Applicability may be restricted by the presence of catalyst poisons in the waste gases. f. Thermal oxidation See Section 1.4.1. NH3, HCN Applicability of recuperative and regenerative thermal oxidation to existing plants may be restricted by design and/or operational constraints. The applicability may be restricted where the energy demand is excessive due to the low concentration of the compound(s) concerned in the process off-gases. Substance/Parameter BAT-AEL (mg/Nm3) (Daily average or average over the sampling period) Ammonia (NH3) 2-10 Elemental chlorine (Cl2) < 0,5-2 Gaseous fluorides, expressed as HF ≤ 1 Hydrogen cyanide (HCN) < 0,1-1 Gaseous chlorides, expressed as HCl 1-10 Nitrogen oxides (NOX) 10-150 Sulphur oxides (SO2) < 3-150 The associated monitoring is given in BAT 8. Grp. 1135. Inorganic compounds Grp. 113. Channelled emissions to air (i) Estimating the annual quantity of diffuse VOC emissions (see BAT 20). (ii) Monitoring diffuse VOC emissions from the use of solvents by compiling a solvent mass balance, if applicable (see BAT 21). (a) Listing of equipment identified as relevant fugitive VOC emission sources in the inventory of diffuse VOC emissions (see BAT 2). (1) Leaky equipment. Typical criteria could be a leak threshold, above which equipment is considered leaky, and/or the visualisation of a leak with OGI cameras. This depends on the characteristics of the emission source (e.g. accessibility) and the hazardous properties of the emitted substance(s). (2) Maintenance and/or repair actions to be carried out. A typical criterion could be a VOC concentration threshold triggering the maintenance or repair action (maintenance/repair threshold). The maintenance/repair threshold is generally equal to or higher than the leak threshold. This depends on the characteristics of the emission source (e.g. accessibility) and the hazardous properties of the emitted substance(s). For the first LDAR programme, it is generally not higher than 5000 ppmv for VOCs other than VOCs classified as CMR 1A or 1B, and 1000 ppmv for VOCs classified as CMR 1A or 1B. For subsequent LDAR programmes, the maintenance/repair threshold is lowered (see point vi. a.) and not higher than 1000 ppmv for VOCs other than VOCs classified as CMR 1A or 1B, and 500 ppmv for VOCs classified as CMR 1A or 1B, targeting 100 ppmv. (b) Definition of criteria associated with the following: (c) Measuring fugitive VOC emissions from equipment listed under point iii. a. (see BAT 22). (d) Carrying out maintenance and/or repair actions (see BAT 23, techniques e. and f.), as soon as possible and where necessary according to the criteria defined in point iii. b. Maintenance and repair actions are prioritised according to the hazardous properties of the emitted substance(s), the significance of the emissions and/or operational constraints. The effectiveness of the maintenance and/or repair actions is verified according to point iii. c., leaving enough time after the intervention (e.g. 2 months). (e) Filling in the database mentioned in point v. (iii) Establishing and implementing a leak detection and repair (LDAR) programme for fugitive VOC emissions. The LDAR programme typically lasts from 1 to 5 years depending on the nature, scale and complexity of the plant (5 years may correspond to large plants with a high number of emission sources). The LDAR programme includes all of the following features: (a) Listing of equipment identified as relevant non-fugitive VOC emission sources in the inventory of diffuse VOC emissions (see BAT 2). (b) Monitoring non-fugitive VOC emissions from equipment listed under point iv. a. (see BAT 22). (c) Planning and implementing techniques to reduce non-fugitive VOC emissions (see BAT 23, techniques a., c. and g. to j.). The planning and implementation of the techniques are prioritised according to the hazardous properties of the emitted substance(s), the significance of the emissions and/or operational constraints. (d) Filling in the database mentioned in point v. (iv) Establishing and implementing a detection and reduction programme for non-fugitive VOC emissions that includes all of the following features: (a) equipment design specifications (including the date and description of any design changes); (b) the equipment maintenance, repair, upgrade, or replacement actions, performed or planned, and their date of implementation; (c) the equipment that could not be maintained, repaired, upgraded or replaced due to operational constraints; (d) the results of the measurements or monitoring, including the concentration(s) of the emitted substance(s), the calculated leak rate (as kg/year), the recording from OGI cameras (e.g. from the last LDAR programme) and the date of the measurements or monitoring; (e) the annual quantity of diffuse VOC emissions (as fugitive and non-fugitive emissions), including information on non-accessible sources and accessible sources not monitored during the year. (v) Establishing and maintaining a database, for diffuse VOC emissions sources that are identified in the inventory mentioned in BAT 2, for keeping record of: (a) lowering the leak and/or maintenance/repair thresholds (see point iii. b.); (b) reviewing the prioritisation of equipment to be monitored, giving higher priority to (the type of) equipment identified as leaky during the previous LDAR programme; (c) planning the maintenance, repair, upgrade or replacement of equipment that could not be performed during the previous LDAR programme due to operational constraints. (vi) Reviewing and updating the LDAR programme periodically. This may include the following: (a) monitoring non-fugitive VOC emissions from equipment where maintenance, repair, upgrade or replacement actions were implemented, in order to determine if those actions were successful; (b) planning the maintenance, repair, upgrade or replacement actions that could not be performed due to operational constraints. (vii) Reviewing and updating the detection and reduction programme for non-fugitive VOC emissions. This may include the following: Grp. applicability. The features points iii., iv., vi., and vii. are only applicable to sources of diffuse VOC emissions for which monitoring according to BAT 22 is applicable. The level of detail of the management system for diffuse VOC emissions will be proportionate to the nature, scale and complexity of the plant, and the range of environmental impacts it may have. Grp. 19. In order to prevent or, where that is not practicable, to reduce diffuse VOC emissions to air, BAT is to elaborate and implement a management system for diffuse VOC emissions, as part of the environmental management system (see BAT 1), that includes all of the following features: Grp. 1141. Management system for diffuse VOC emissions (1) chemical properties of the substance (e.g. vapour pressure, molecular mass); (2) process operating data (e.g. operating time, product quantity, ventilation); (3) characteristics of the emission source (e.g. tank diameter, colour, shape). Grp. note. The estimation of the diffuse VOC emissions to air takes into account the results of the monitoring carried out according to BAT 21 and/or to BAT 22. For the purpose of the estimation, channelled emissions may be counted as non-fugitive emissions when the inherent characteristics of the waste gas stream (e.g. low velocities, variability of the flow rate and concentration) do not allow an accurate measurement according to BAT 8. The main sources of uncertainty of the estimation are identified, and corrective actions are implemented to reduce the uncertainty. Technique Description Type of emissions a. Use of emission factors See Section 1.4.2. Fugitive and/or non-fugitive b. Use of a mass balance Estimation based on the difference in the mass of the substance inputs to and outputs from the plant/production unit, taking into account the generation and destruction of the substance in the plant/production unit. A mass balance may also consist of measuring the concentration of VOCs in the product (e.g. raw material or solvent). c. Use of thermodynamic models Estimation using the laws of thermodynamics applied to equipment (e.g. tanks) or particular steps of a production process. The following data are generally used as input for the model: Grp. 20. BAT is to estimate fugitive and non-fugitive VOC emissions to air separately at least once every year by using one or a combination of the techniques given below, as well as to determine the uncertainty of this estimation. The estimation distinguishes between VOCs classified as CMR 1A or 1B and VOCs that are not classified as CMR 1A or 1B. (1) identification and documentation of solvent inputs and outputs (e.g. channelled and diffuse emissions to air, emissions to water, solvent output in waste); (2) substantiated quantification of each relevant solvent input and output and recording of the methodology used (e.g. measurement, estimation by using emission factors, estimation based on operational parameters); (3) identification of the main sources of uncertainty of the aforementioned quantification, and implementation of corrective actions to reduce the uncertainty; (4) regular update of solvent input and output data. (5) malfunctions of the waste gas treatment system: the date and period of time are recorded; (6) changes that may influence air/gas flow rates (e.g. replacement of fans): the date and type of change are recorded. Grp. applicability. This BAT may not apply to the production of polyolefins, PVC or synthetic rubbers. This BAT may not be applicable to plants whose total annual consumption of solvents is lower than 50 tonnes. The level of detail of the solvent mass balance will be proportionate to the nature, scale and complexity of the plant, and the range of environmental impacts it may have, as well as to the type and quantity of solvents used. Grp. 21. BAT is to monitor diffuse VOC emissions from the use of solvents by compiling, at least once every year, a solvent mass balance of the solvent inputs and outputs of the plant, as defined in Part 7 of Annex VII to Directive 2010/75/EU and to minimise the uncertainty of the solvent mass balance data by using all of the techniques given below. Technique Description a. Full identification and quantification of the relevant solvent inputs and outputs, including the associated uncertainty This includes: b. Implementation of a solvent tracking system A solvent tracking system aims to keep control of both the used and unused quantities of solvents (e.g. by weighing unused quantities returned to storage from the application area). c. Monitoring of changes that may influence the uncertainty of the solvent mass balance data Any change that could influence the uncertainty of the solvent mass balance data is recorded, such as: Grp. note. Optical gas imaging (OGI) is a useful complementary technique to the method EN 15446 (sniffing) in order to identify sources of fugitive VOC emissions and is particularly relevant in the case of inaccessible sources (see Section 1.4.2.). This technique is described in EN 17628. In the case of non-fugitive emissions, measurements may be complemented by the use of thermodynamic models. Where large amounts (e.g. above 80 t/yr) of VOCs are used/consumed, the quantification of VOC emissions from the plant with tracer correlation (TC) or with optical absorption-based techniques, such as differential absorption light detection and ranging (DIAL) or solar occultation flux (SOF), is a useful complementary technique (see Section 1.4.2.). These techniques are described in EN 17628. (1) 1 tonne of VOCs per year in the case of VOCs classified as CMR 1A or 1B; or (2) 5 tonnes of VOCs per year in the case of other VOCs. (3) 1 tonne of VOCs per year in the case of VOCs classified as CMR 1A or 1B; or (4) 5 tonnes of VOCs per year in the case of other VOCs. Grp. applicability. BAT 22 only applies when the annual quantity of diffuse VOC emissions from the plant estimated according to BAT 20 is greater than the following: For fugitive emissions: For non-fugitive emissions: Grp. 22. BAT is to monitor diffuse VOC emissions to air with at least the frequency given below and in accordance with EN standards. If EN standards are not available, BAT is to use ISO, national or other international standards that ensure the provision of data of an equivalent scientific quality. Type of sources of diffuse VOC emissions Type of VOCs Standard(s) Minimum monitoring frequency Sources of fugitive emissions VOCs classified as CMR 1A or 1B EN 15446 Once every year VOCs not classified as CMR 1A or 1B Once during the period covered by each LDAR programme (see BAT 19 point iii.) Sources of non-fugitive emissions VOCs classified as CMR 1A or 1B EN 17628 Once every year VOCs not classified as CMR 1A or 1B Once every year Grp. 1142. Monitoring (1) minimising pipe lengths; (2) reducing the number of pipe connectors (e.g. flanges) and valves; (3) using welded fittings and connections; (4) using compressed air or gravity for material transfer. (5) bellow valves or double packing seals or equally effective equipment; (6) magnetically driven or canned pumps/compressors/agitators, or pumps/compressors/agitators using double seals and a liquid barrier; (7) certified high-quality gaskets (e.g. according to EN 13555) that are tightened according to technique e.; (8) closed sampling system. (9) emissions of CMR substances or substances with acute toxicity; and/or (10) emissions from equipment with high-leaking potential; and/or (11) leaks from processes operated at high pressures (e.g. between 300 bar and 2000 bar). (12) for existing plants; and/or (13) by safety concerns (e.g. avoiding concentrations close to the lower explosive limit). (14) tightening of gaskets by personnel that is qualified according to EN 1591-4 and using the designed gasket stress (e.g. calculated according to EN 1591-1); (15) installing tight caps on open ends; (16) using flanges selected and assembled according to EN 13555. (17) gaskets; (18) sealing elements (e.g. tank lid); (19) packing material (e.g. valve stem packing material). (20) reducing the use of solvents and/or using solvents with lower volatility; (21) reducing the formation of side products containing VOCs; (22) lowering the operating temperature; (23) lowering the VOC content in the final product. (24) reducing the frequency and duration of reactor and vessel openings; (25) preventing corrosion by lining or coating of equipment, by painting pipes (for external corrosion) and by using corrosion inhibitors for materials in contact with equipment. (26) vapour balancing (see Section 1.4.3); (27) closed systems for solid/liquid and liquid/liquid phase separations; (28) closed systems for cleaning operations; (29) closed sewers and/or waste water treatment plants; (30) closed sampling systems; (31) closed storage areas. (32) installing oil creaming systems on open surfaces; (33) periodically skimming open surfaces (e.g. removing floating matter); (34) installing anti-evaporation floating elements on open surfaces; (35) treating waste water streams to remove VOCs and send the VOCs to recovery (see BAT 9 and BAT 10) and/or abatement (see BAT 11); (36) installing floating roofs on tanks; (37) using fixed-roof tanks connected to a waste gas treatment. Grp. 1. The use of techniques to prevent or, where that is not practicable, to reduce diffuse VOC emissions to air is prioritised according to the hazardous properties of the emitted substance(s) and/or the significance of the emissions. Technique Description Type of emissions Applicability Prevention techniques a. Limiting the number of emission sources This includes: Fugitive and non-fugitive emissions Applicability may be restricted by operational constraints in the case of existing plants. b. Use of high-integrity equipment High-integrity equipment includes, but is not limited to: The use of high-integrity equipment is especially relevant to prevent or minimise: High-integrity equipment is selected, installed and maintained according to the type of process and the process operating conditions. Fugitive emissions Applicability may be restricted by operational constraints in the case of existing plants. Generally applicable to new plants and major plant upgrades. c. Collecting diffuse emissions and treating off-gases Collecting diffuse VOC emissions (e.g. from compressor seals, vents and purge lines) and sending them to recovery (see BAT 9 and BAT 10) and/or abatement (see BAT 11). Fugitive and non-fugitive emissions Applicability may be restricted: Other techniques d. Facilitating access and/or monitoring activities To ease maintenance and/or monitoring activities, the access to potentially leaky equipment is facilitated, e.g. by installing platforms, and/or drones are used for monitoring. Fugitive emissions Applicability may be restricted by operational constraints in the case of existing plants. e. Tightening This includes: Fugitive emissions Generally applicable. f. Replacement of leaky equipment and/or parts This includes the replacement of: Fugitive emissions Generally applicable. g. Reviewing and updating process design This includes: Non-fugitive emissions Applicability may be restricted in the case of existing plants due to operational constraints. h. Reviewing and updating operating conditions This includes: Non-fugitive emissions Generally applicable. i. Using closed systems This includes: Off-gases from closed systems are sent to recovery (see BAT 9 and BAT 10) and/or abatement (see BAT 11). Non-fugitive emissions Applicability may be restricted by operational constraints in the case of existing plants and/or by safety concerns. j. Using techniques to minimise emissions from surfaces This includes: Non-fugitive emissions Applicability may be restricted by operational constraints in the case of existing plants. Grp. 23. In order to prevent or, where that is not practicable, to reduce diffuse VOC emissions to air, BAT is to use a combination of the techniques given below with the following order of priority. Grp. 1143. Prevention or reduction of diffuse VOC emissions Grp_1144_table. 17. BAT conclusions for the use of solvents or the reuse of recovered solvents The emission levels for the use of solvents or the reuse of recovered solvents given below are associated with the general BAT conclusions given in Section 1.1 and Section 1.1.4.3. Parameter BAT-AEL (percentage of the solvent inputs) (yearly average) Diffuse VOC emissions ≤ 5 % The associated monitoring is given in BAT 20, BAT 21 and BAT 22. Grp. 114. Diffuse VOC emissions to air
1.1.
1.1.1. Environmental management systems (i) commitment, leadership, and accountability of the management, including senior management, for the implementation of an effective EMS; (ii) an analysis that includes the determination of the organisation’s context, the identification of the needs and expectations of interested parties, the identification of characteristics of the installation that are associated with possible risks for the environment (or human health) as well as of the applicable legal requirements relating to the environment; (iii) development of an environmental policy that includes the continuous improvement of the environmental performance of the installation; (iv) establishing objectives and performance indicators in relation to significant environmental aspects, including safeguarding compliance with applicable legal requirements; (v) planning and implementing the necessary procedures and actions (including corrective and preventive actions where needed), to achieve the environmental objectives and avoid environmental risks; (vi) determination of structures, roles and responsibilities in relation to environmental aspects and objectives and provision of the financial and human resources needed; (vii) ensuring the necessary competence and awareness of staff whose work may affect the environmental performance of the installation (e.g. by providing information and training); (viii) internal and external communication; (ix) fostering employee involvement in good environmental management practices; (x) establishing and maintaining a management manual and written procedures to control activities with significant environmental impact as well as relevant records; (xi) effective operational planning and process control; (xii) implementation of appropriate maintenance programmes; (xiii) emergency preparedness and response protocols, including the prevention and/or mitigation of the adverse (environmental) impacts of emergency situations; (xiv) when (re)designing a (new) installation or a part thereof, consideration of its environmental impacts throughout its life, which includes construction, maintenance, operation and decommissioning; (xv) implementation of a monitoring and measurement programme; if necessary, information can be found in the Reference Report on Monitoring of Emissions to Air and Water from IED Installations; (xvi) application of sectoral benchmarking on a regular basis; (xvii) periodic independent (as far as practicable) internal auditing and periodic independent external auditing in order to assess the environmental performance and to determine whether or not the EMS conforms to planned arrangements and has been properly implemented and maintained; (xviii) evaluation of causes of nonconformities, implementation of corrective actions in response to nonconformities, review of the effectiveness of corrective actions, and determination of whether similar nonconformities exist or could potentially occur; (xix) periodic review, by senior management, of the EMS and its continuing suitability, adequacy and effectiveness; (xx) following and taking into account the development of cleaner techniques. (xxi) an inventory of channelled and diffuse emissions to air (see BAT 2); (xxii) an OTNOC management plan for emissions to air (see BAT 3); (xxiii) an integrated waste gas management and treatment strategy for channelled emissions to air (see BAT 4); (xxiv) a management system for diffuse VOC emissions to air (see BAT 19); (xxv) a chemicals management system that includes an inventory of the hazardous substances and substances of very high concern used in the process(es); the potential for substitution of the substances that are listed in this inventory, focusing on those substances other than raw materials, is analysed periodically (e.g. annually) in order to identify possible new available and safer alternatives, with no or lower environmental impacts. Grp. note. Regulation (EC) No 1221/2009 of the European Parliament and of the Council establishes the European Union eco-management and audit scheme (EMAS), which is an example of an EMS consistent with this BAT. Grp. applicability. The level of detail and the degree of formalisation of the EMS will generally be related to the nature, scale and complexity of the installation, and the range of environmental impacts it may have. Grp. 1. In order to improve the overall environmental performance, BAT is to elaborate and implement an environmental management system (EMS) that incorporates all of the following features: Specifically for the chemical sector, BAT is also to incorporate the following features in the EMS: (a) chemical reaction equations, also showing side products; (b) simplified process flow sheets that show the origin of the emissions; (i) information, as comprehensive as is reasonably possible, about the chemical production process(es), including: (a) emission point(s); (b) average values and variability of flow and temperature; (c) average concentration and mass flow values of relevant substances/parameters and their variability (e.g. TVOC, CO, NOX, SOX, Cl2, HCl); (d) presence of other substances that may affect the waste gas treatment system(s) or plant safety (e.g. oxygen, nitrogen, water vapour, dust); (e) techniques used to prevent and/or reduce channelled emissions to air; (f) flammability, lower and higher explosive limits, reactivity; (g) monitoring methods (see BAT 8); (h) presence of substances classified as CMR 1A, CMR 1B or CMR 2; the presence of such substances may for example be assessed according to the criteria of Regulation (EC) No 1272/2008 on classification, labelling and packaging (CLP). (ii) information, as comprehensive as is reasonably possible, about channelled emissions to air, such as: (a) identification of the emission source(s); (b) characteristics of each emission source (e.g. fugitive or non-fugitive; static or moving; accessibility of the emission source; included in an LDAR programme or not); (1) physical state; (2) vapour pressure of the substance(s) in the liquid, pressure of the gas; (3) temperature; (4) composition (by weight for liquids or by volume for gases); (5) hazardous properties of the substance(s) or mixtures, including substances or mixtures classified as CMR 1A, CMR 1B or CMR 2; (c) the characteristics of the gas or liquid in contact with the emission source(s), including: (d) techniques used to prevent and/or reduce diffuse emissions to air; (e) monitoring (see BAT 20, BAT 21 and BAT 22). (iii) information, as comprehensive as is reasonably possible, about diffuse emissions to air, such as: Grp_for_diffuse. emissions. The information about diffuse emissions to air is particularly relevant for activities using large amounts of organic substances or mixtures (e.g. production of pharmaceuticals, production of large volumes of organic chemicals or of polymers). The information about fugitive emissions covers all emission sources in contact with organic substances with a vapour pressure greater than 0,3 kPa at 293,15 K. Sources of fugitive emissions connected to pipes whose diameter is small (e.g. smaller than 12,7 mm, i.e. 0,5 inch) may be excluded from the inventory. Equipment operated under subatmospheric pressure may be excluded from the inventory. Grp. applicability. The level of detail and the degree of formalisation of the inventory will generally be related to the nature, scale and complexity of the installation, and the range of environmental impacts it may have. Grp. 2. In order to facilitate the reduction of emissions to air, BAT is to establish, maintain and regularly review (including when a substantial change occurs) an inventory of channelled and diffuse emissions to air, as part of the environmental management system (see BAT 1), that incorporates all of the following features:
1.1.1.
BAT 1. In order to improve the overall environmental performance, BAT is to elaborate and implement an environmental management system (EMS) that incorporates all of the following features: Specifically for the chemical sector, BAT is also to incorporate the following features in the EMS: (i) commitment, leadership, and accountability of the management, including senior management, for the implementation of an effective EMS; (ii) an analysis that includes the determination of the organisation’s context, the identification of the needs and expectations of interested parties, the identification of characteristics of the installation that are associated with possible risks for the environment (or human health) as well as of the applicable legal requirements relating to the environment; (iii) development of an environmental policy that includes the continuous improvement of the environmental performance of the installation; (iv) establishing objectives and performance indicators in relation to significant environmental aspects, including safeguarding compliance with applicable legal requirements; (v) planning and implementing the necessary procedures and actions (including corrective and preventive actions where needed), to achieve the environmental objectives and avoid environmental risks; (vi) determination of structures, roles and responsibilities in relation to environmental aspects and objectives and provision of the financial and human resources needed; (vii) ensuring the necessary competence and awareness of staff whose work may affect the environmental performance of the installation (e.g. by providing information and training); (viii) internal and external communication; (ix) fostering employee involvement in good environmental management practices; (x) establishing and maintaining a management manual and written procedures to control activities with significant environmental impact as well as relevant records; (xi) effective operational planning and process control; (xii) implementation of appropriate maintenance programmes; (xiii) emergency preparedness and response protocols, including the prevention and/or mitigation of the adverse (environmental) impacts of emergency situations; (xiv) when (re)designing a (new) installation or a part thereof, consideration of its environmental impacts throughout its life, which includes construction, maintenance, operation and decommissioning; (xv) implementation of a monitoring and measurement programme; if necessary, information can be found in the Reference Report on Monitoring of Emissions to Air and Water from IED Installations; (xvi) application of sectoral benchmarking on a regular basis; (xvii) periodic independent (as far as practicable) internal auditing and periodic independent external auditing in order to assess the environmental performance and to determine whether or not the EMS conforms to planned arrangements and has been properly implemented and maintained; (xviii) evaluation of causes of nonconformities, implementation of corrective actions in response to nonconformities, review of the effectiveness of corrective actions, and determination of whether similar nonconformities exist or could potentially occur; (xix) periodic review, by senior management, of the EMS and its continuing suitability, adequacy and effectiveness; (xx) following and taking into account the development of cleaner techniques. (xxi) an inventory of channelled and diffuse emissions to air (see BAT 2); (xxii) an OTNOC management plan for emissions to air (see BAT 3); (xxiii) an integrated waste gas management and treatment strategy for channelled emissions to air (see BAT 4); (xxiv) a management system for diffuse VOC emissions to air (see BAT 19); (xxv) a chemicals management system that includes an inventory of the hazardous substances and substances of very high concern used in the process(es); the potential for substitution of the substances that are listed in this inventory, focusing on those substances other than raw materials, is analysed periodically (e.g. annually) in order to identify possible new available and safer alternatives, with no or lower environmental impacts. Grp. note. Regulation (EC) No 1221/2009 of the European Parliament and of the Council establishes the European Union eco-management and audit scheme (EMAS), which is an example of an EMS consistent with this BAT. Grp. applicability. The level of detail and the degree of formalisation of the EMS will generally be related to the nature, scale and complexity of the installation, and the range of environmental impacts it may have.
BAT 1. i.
commitment, leadership, and accountability of the management, including senior management, for the implementation of an effective EMS;
ii.
an analysis that includes the determination of the organisation’s context, the identification of the needs and expectations of interested parties, the identification of characteristics of the installation that are associated with possible risks for the environment (or human health) as well as of the applicable legal requirements relating to the environment;
iii.
development of an environmental policy that includes the continuous improvement of the environmental performance of the installation;
iv.
establishing objectives and performance indicators in relation to significant environmental aspects, including safeguarding compliance with applicable legal requirements;
v.
planning and implementing the necessary procedures and actions (including corrective and preventive actions where needed), to achieve the environmental objectives and avoid environmental risks;
vi.
determination of structures, roles and responsibilities in relation to environmental aspects and objectives and provision of the financial and human resources needed;
vii.
ensuring the necessary competence and awareness of staff whose work may affect the environmental performance of the installation (e.g. by providing information and training);
viii.
internal and external communication;
ix.
fostering employee involvement in good environmental management practices;
x.
establishing and maintaining a management manual and written procedures to control activities with significant environmental impact as well as relevant records;
xi.
effective operational planning and process control;
xii.
implementation of appropriate maintenance programmes;
xiii.
emergency preparedness and response protocols, including the prevention and/or mitigation of the adverse (environmental) impacts of emergency situations;
xiv.
when (re)designing a (new) installation or a part thereof, consideration of its environmental impacts throughout its life, which includes construction, maintenance, operation and decommissioning;
xv.
implementation of a monitoring and measurement programme; if necessary, information can be found in the Reference Report on Monitoring of Emissions to Air and Water from IED Installations;
xvi.
application of sectoral benchmarking on a regular basis;
xvii.
periodic independent (as far as practicable) internal auditing and periodic independent external auditing in order to assess the environmental performance and to determine whether or not the EMS conforms to planned arrangements and has been properly implemented and maintained;
xviii.
evaluation of causes of nonconformities, implementation of corrective actions in response to nonconformities, review of the effectiveness of corrective actions, and determination of whether similar nonconformities exist or could potentially occur;
xix.
periodic review, by senior management, of the EMS and its continuing suitability, adequacy and effectiveness;
xx.
following and taking into account the development of cleaner techniques.
xxi.
an inventory of channelled and diffuse emissions to air (see BAT 2);
xxii.
an OTNOC management plan for emissions to air (see BAT 3);
xxiii.
an integrated waste gas management and treatment strategy for channelled emissions to air (see BAT 4);
xxiv.
a management system for diffuse VOC emissions to air (see BAT 19);
xxv.
a chemicals management system that includes an inventory of the hazardous substances and substances of very high concern used in the process(es); the potential for substitution of the substances that are listed in this inventory, focusing on those substances other than raw materials, is analysed periodically (e.g. annually) in order to identify possible new available and safer alternatives, with no or lower environmental impacts.
Note
Regulation (EC) No 1221/2009 of the European Parliament and of the Council establishes the European Union eco-management and audit scheme (EMAS), which is an example of an EMS consistent with this BAT.
Applicability
The level of detail and the degree of formalisation of the EMS will generally be related to the nature, scale and complexity of the installation, and the range of environmental impacts it may have.
BAT 2. In order to facilitate the reduction of emissions to air, BAT is to establish, maintain and regularly review (including when a substantial change occurs) an inventory of channelled and diffuse emissions to air, as part of the environmental management system (see BAT 1), that incorporates all of the following features: (a) chemical reaction equations, also showing side products; (b) simplified process flow sheets that show the origin of the emissions; (i) information, as comprehensive as is reasonably possible, about the chemical production process(es), including: (a) emission point(s); (b) average values and variability of flow and temperature; (c) average concentration and mass flow values of relevant substances/parameters and their variability (e.g. TVOC, CO, NOX, SOX, Cl2, HCl); (d) presence of other substances that may affect the waste gas treatment system(s) or plant safety (e.g. oxygen, nitrogen, water vapour, dust); (e) techniques used to prevent and/or reduce channelled emissions to air; (f) flammability, lower and higher explosive limits, reactivity; (g) monitoring methods (see BAT 8); (h) presence of substances classified as CMR 1A, CMR 1B or CMR 2; the presence of such substances may for example be assessed according to the criteria of Regulation (EC) No 1272/2008 on classification, labelling and packaging (CLP). (ii) information, as comprehensive as is reasonably possible, about channelled emissions to air, such as: (a) identification of the emission source(s); (b) characteristics of each emission source (e.g. fugitive or non-fugitive; static or moving; accessibility of the emission source; included in an LDAR programme or not); (1) physical state; (2) vapour pressure of the substance(s) in the liquid, pressure of the gas; (3) temperature; (4) composition (by weight for liquids or by volume for gases); (5) hazardous properties of the substance(s) or mixtures, including substances or mixtures classified as CMR 1A, CMR 1B or CMR 2; (c) the characteristics of the gas or liquid in contact with the emission source(s), including: (d) techniques used to prevent and/or reduce diffuse emissions to air; (e) monitoring (see BAT 20, BAT 21 and BAT 22). (iii) information, as comprehensive as is reasonably possible, about diffuse emissions to air, such as: Grp_for_diffuse. emissions. The information about diffuse emissions to air is particularly relevant for activities using large amounts of organic substances or mixtures (e.g. production of pharmaceuticals, production of large volumes of organic chemicals or of polymers). The information about fugitive emissions covers all emission sources in contact with organic substances with a vapour pressure greater than 0,3 kPa at 293,15 K. Sources of fugitive emissions connected to pipes whose diameter is small (e.g. smaller than 12,7 mm, i.e. 0,5 inch) may be excluded from the inventory. Equipment operated under subatmospheric pressure may be excluded from the inventory. Grp. applicability. The level of detail and the degree of formalisation of the inventory will generally be related to the nature, scale and complexity of the installation, and the range of environmental impacts it may have.
BAT 2. i.
information, as comprehensive as is reasonably possible, about the chemical production process(es), including: (a) chemical reaction equations, also showing side products; (b) simplified process flow sheets that show the origin of the emissions;
a.
chemical reaction equations, also showing side products;
b.
simplified process flow sheets that show the origin of the emissions;
ii.
information, as comprehensive as is reasonably possible, about channelled emissions to air, such as: (a) emission point(s); (b) average values and variability of flow and temperature; (c) average concentration and mass flow values of relevant substances/parameters and their variability (e.g. TVOC, CO, NOX, SOX, Cl2, HCl); (d) presence of other substances that may affect the waste gas treatment system(s) or plant safety (e.g. oxygen, nitrogen, water vapour, dust); (e) techniques used to prevent and/or reduce channelled emissions to air; (f) flammability, lower and higher explosive limits, reactivity; (g) monitoring methods (see BAT 8); (h) presence of substances classified as CMR 1A, CMR 1B or CMR 2; the presence of such substances may for example be assessed according to the criteria of Regulation (EC) No 1272/2008 on classification, labelling and packaging (CLP).
a.
emission point(s);
b.
average values and variability of flow and temperature;
c.
average concentration and mass flow values of relevant substances/parameters and their variability (e.g. TVOC, CO, NOX, SOX, Cl2, HCl);
d.
presence of other substances that may affect the waste gas treatment system(s) or plant safety (e.g. oxygen, nitrogen, water vapour, dust);
e.
techniques used to prevent and/or reduce channelled emissions to air;
f.
flammability, lower and higher explosive limits, reactivity;
g.
monitoring methods (see BAT 8);
h.
presence of substances classified as CMR 1A, CMR 1B or CMR 2; the presence of such substances may for example be assessed according to the criteria of Regulation (EC) No 1272/2008 on classification, labelling and packaging (CLP).
iii.
information, as comprehensive as is reasonably possible, about diffuse emissions to air, such as: (a) identification of the emission source(s); (b) characteristics of each emission source (e.g. fugitive or non-fugitive; static or moving; accessibility of the emission source; included in an LDAR programme or not); (1) physical state; (2) vapour pressure of the substance(s) in the liquid, pressure of the gas; (3) temperature; (4) composition (by weight for liquids or by volume for gases); (5) hazardous properties of the substance(s) or mixtures, including substances or mixtures classified as CMR 1A, CMR 1B or CMR 2; (c) the characteristics of the gas or liquid in contact with the emission source(s), including: (d) techniques used to prevent and/or reduce diffuse emissions to air; (e) monitoring (see BAT 20, BAT 21 and BAT 22).
a.
identification of the emission source(s);
b.
characteristics of each emission source (e.g. fugitive or non-fugitive; static or moving; accessibility of the emission source; included in an LDAR programme or not);
c.
the characteristics of the gas or liquid in contact with the emission source(s), including: (1) physical state; (2) vapour pressure of the substance(s) in the liquid, pressure of the gas; (3) temperature; (4) composition (by weight for liquids or by volume for gases); (5) hazardous properties of the substance(s) or mixtures, including substances or mixtures classified as CMR 1A, CMR 1B or CMR 2;
1. physical state;
2. vapour pressure of the substance(s) in the liquid, pressure of the gas;
3. temperature;
4. composition (by weight for liquids or by volume for gases);
5. hazardous properties of the substance(s) or mixtures, including substances or mixtures classified as CMR 1A, CMR 1B or CMR 2;
d.
techniques used to prevent and/or reduce diffuse emissions to air;
e.
monitoring (see BAT 20, BAT 21 and BAT 22).
Note for diffuse emissions
The information about diffuse emissions to air is particularly relevant for activities using large amounts of organic substances or mixtures (e.g. production of pharmaceuticals, production of large volumes of organic chemicals or of polymers). The information about fugitive emissions covers all emission sources in contact with organic substances with a vapour pressure greater than 0,3 kPa at 293,15 K. Sources of fugitive emissions connected to pipes whose diameter is small (e.g. smaller than 12,7 mm, i.e. 0,5 inch) may be excluded from the inventory. Equipment operated under subatmospheric pressure may be excluded from the inventory.
Applicability
The level of detail and the degree of formalisation of the inventory will generally be related to the nature, scale and complexity of the installation, and the range of environmental impacts it may have.
1.1.2. Other than normal operating conditions (OTNOC) (i) identification of potential OTNOC (e.g. failure of equipment critical to the control of channelled emissions to air, or equipment critical to the prevention of accidents or incidents that could lead to emissions to air (critical equipment)), of their root causes and of their potential consequences; (ii) appropriate design of critical equipment (e.g. equipment modularity and compartmentalisation, backup systems, techniques to obviate the need to bypass waste gas treatment during start-up and shutdown, high-integrity equipment, etc.); (iii) set-up and implementation of a preventive maintenance plan for critical equipment (see BAT 1 xii.); (iv) monitoring (i.e. estimating or, where this is possible, measuring) and recording of emissions and associated circumstances during OTNOC; (v) periodic assessment of the emissions occurring during OTNOC (e.g. frequency of events, duration, amount of pollutants emitted as recorded in point iv.) and implementation of corrective actions if necessary; (vi) regular review and update of the list of identified OTNOC under point i. following the periodic assessment of point v.; (vii) regular testing of backup systems. Grp. 3. In order to reduce the frequency of the occurrence of OTNOC and to reduce emissions to air during OTNOC, BAT is to set up and implement a risk-based OTNOC management plan as part of the environmental management system (see BAT 1) that includes all of the following features:
1.1.2.
BAT 3. In order to reduce the frequency of the occurrence of OTNOC and to reduce emissions to air during OTNOC, BAT is to set up and implement a risk-based OTNOC management plan as part of the environmental management system (see BAT 1) that includes all of the following features: (i) identification of potential OTNOC (e.g. failure of equipment critical to the control of channelled emissions to air, or equipment critical to the prevention of accidents or incidents that could lead to emissions to air (critical equipment)), of their root causes and of their potential consequences; (ii) appropriate design of critical equipment (e.g. equipment modularity and compartmentalisation, backup systems, techniques to obviate the need to bypass waste gas treatment during start-up and shutdown, high-integrity equipment, etc.); (iii) set-up and implementation of a preventive maintenance plan for critical equipment (see BAT 1 xii.); (iv) monitoring (i.e. estimating or, where this is possible, measuring) and recording of emissions and associated circumstances during OTNOC; (v) periodic assessment of the emissions occurring during OTNOC (e.g. frequency of events, duration, amount of pollutants emitted as recorded in point iv.) and implementation of corrective actions if necessary; (vi) regular review and update of the list of identified OTNOC under point i. following the periodic assessment of point v.; (vii) regular testing of backup systems.
BAT 3. i.
identification of potential OTNOC (e.g. failure of equipment critical to the control of channelled emissions to air, or equipment critical to the prevention of accidents or incidents that could lead to emissions to air (critical equipment)), of their root causes and of their potential consequences;
ii.
appropriate design of critical equipment (e.g. equipment modularity and compartmentalisation, backup systems, techniques to obviate the need to bypass waste gas treatment during start-up and shutdown, high-integrity equipment, etc.);
iii.
set-up and implementation of a preventive maintenance plan for critical equipment (see BAT 1 xii.);
iv.
monitoring (i.e. estimating or, where this is possible, measuring) and recording of emissions and associated circumstances during OTNOC;
v.
periodic assessment of the emissions occurring during OTNOC (e.g. frequency of events, duration, amount of pollutants emitted as recorded in point iv.) and implementation of corrective actions if necessary;
vi.
regular review and update of the list of identified OTNOC under point i. following the periodic assessment of point v.;
vii.
regular testing of backup systems.
1.1.3. Channelled emissions to air Grp. description. The integrated waste gas management and treatment strategy is based on the inventory in BAT 2. It takes into account factors such as greenhouse gas emissions and the consumption or reuse of energy, water and materials associated with the use of the different techniques. Grp. 4. In order to reduce channelled emissions to air, BAT is to use an integrated waste gas management and treatment strategy that includes, in order of priority, process-integrated recovery and abatement techniques. Grp. description. The combined treatment of waste gases with similar characteristics ensures more effective and efficient treatment compared to the separate treatment of individual waste gas streams. The combination of waste gases is carried out considering plant safety (e.g. avoiding concentrations close to the lower/upper explosive limit), technical (e.g. compatibility of the individual waste gas streams, concentration of the substances concerned), environmental (e.g. maximising recovery of materials or pollutant abatement) and economic factors (e.g. distance between different production units). Care is taken that the combination of waste gases does not lead to the dilution of emissions. Grp. 5. In order to facilitate the recovery of materials and the reduction of channelled emissions to air, as well as to increase energy efficiency, BAT is to combine waste gas streams with similar characteristics, thus minimising the number of emission points. Grp. 6. In order to reduce channelled emissions to air, BAT is to ensure that the waste gas treatment systems are appropriately designed (e.g. considering the maximum flow rate and pollutant concentrations), operated within their design ranges, and maintained (through preventive, corrective, regular and unplanned maintenance) so as to ensure optimal availability, effectiveness and efficiency of the equipment. Grp. 1131. General techniques Grp. 7. BAT is to continuously monitor key process parameters (e.g. waste gas flow and temperature) of waste gas streams being sent to pretreatment and/or final treatment. Grp. 8. BAT is to monitor channelled emissions to air with at least the frequency given below and in accordance with EN standards. If EN standards are not available, BAT is to use ISO, national or other international standards that ensure the provision of data of an equivalent scientific quality. Substance/Parameter Process(es)/Source(s) Emission points Standard(s) Minimum monitoring frequency Monitoring associated with Ammonia (NH3) Use of SCR/SNCR Any stack EN 21877 Once every 6 months BAT 17 All other processes/sources BAT 18 Benzene All processes/sources Any stack No EN standard available Once every 6 months BAT 11 1,3-Butadiene All processes/sources Any stack No EN standard available Once every 6 months BAT 11 Carbon monoxide (CO) Thermal treatment Any stack with a CO mass flow of ≥ 2 kg/h Generic EN standards Continuous BAT 16 Any stack with a CO mass flow of < 2 kg/h EN 15058 Once every 6 months Process furnaces/heaters Any stack with a CO mass flow of ≥ 2 kg/h Generic EN standards Continuous BAT 36 Any stack with a CO mass flow of < 2 kg/h EN 15058 Once every 6 months All other processes/sources Any stack with a CO mass flow of ≥ 2 kg/h Generic EN standards Continuous BAT 18 Any stack with a CO mass flow of < 2 kg/h EN 15058 Once every year Chloromethane All processes/sources Any stack No EN standard available Once every 6 months BAT 11 CMR substances other than CMR substances covered elsewhere in this table All other processes/sources Any stack No EN standard available Once every 6 months BAT 11 Dichloromethane All processes/sources Any stack No EN standard available Once every 6 months BAT 11 Dust All processes/sources Any stack with dust mass flow ≥ 3 kg/h Generic EN standards, EN 13284-1 and EN 13284-2 Continuous BAT 14 Any stack with dust mass flow < 3 kg/h EN 13284-1 Once every year Elemental chlorine (Cl2) All processes/sources Any stack No EN standard available Once every year BAT 18 Ethylene dichloride (EDC) All processes/sources Any stack No EN standard available Once every 6 months BAT 11 Ethylene oxide All processes/sources Any stack No EN standard available Once every 6 months BAT 11 Formaldehyde All processes/sources Any stack EN standard under development Once every 6 months BAT 11 Gaseous chlorides All processes/sources Any stack EN 1911 Once every year BAT 18 Gaseous fluorides All processes/sources Any stack No EN standard available Once every year BAT 18 Hydrogen cyanide (HCN) All processes/sources Any stack No EN standard available Once every year BAT 18 Lead and its compounds All processes/sources Any stack EN 14385 Once every 6 months BAT 14 Nickel and its compounds All processes/sources Any stack EN 14385 Once every 6 months BAT 14 Nitrous oxide (N2O) All processes/sources Any stack EN ISO 21258 Once every year – Nitrogen oxides (NOX) Thermal treatment Any stack with a NOX mass flow of ≥ 2,5 kg/h Generic EN standards Continuous BAT 16 Any stack with a NOX mass flow of < 2,5 kg/h EN 14792 Once every 6 months Process furnaces/heaters Any stack with a NOX mass flow of ≥ 2,5 kg/h Generic EN standards Continuous BAT 36 Any stack with a NOX mass flow of < 2,5 kg/h EN 14792 Once every 6 months All other processes/sources Any stack with a NOX mass flow of ≥ 2,5 kg/h Generic EN standards Continuous BAT 18 Any stack with a NOX mass flow of < 2,5 kg/h EN 14792 Once every 6 months PCDD/F Thermal treatment Any stack EN 1948-1, EN 1948-2, EN 1948-3 Once every 6 months BAT 12 PM2,5 and PM10 All processes/sources Any stack EN ISO 23210 Once every year BAT 14 Propylene oxide All processes/sources Any stack No EN standard available Once every 6 months BAT 11 Sulphur dioxide (SO2) Thermal treatment Any stack with a SO2 mass flow of ≥ 2,5 kg/h Generic EN standards Continuous BAT 16 Any stack with a SO2 mass flow of < 2,5 kg/h EN 14791 Once every 6 months Process furnaces/heaters Any stack with a SO2 mass flow of ≥ 2,5 kg/h Generic EN standards Continuous BAT 18, BAT 36 Any stack with a SO2 mass flow of < 2,5 kg/h EN 14791 Once every 6 months All other processes/sources Any stack with a SO2 mass flow of ≥ 2,5 kg/h Generic EN standards Continuous BAT 18 Any stack with a SO2 mass flow of < 2,5 kg/h EN 14791 Once every 6 months Tetrachloromethane All processes/sources Any stack No EN standard available Once every 6 months BAT 11 Toluene All processes/sources Any stack No EN standard available Once every 6 months BAT 11 Trichloromethane All processes/sources Any stack No EN standard available Once every 6 months BAT 11 Total volatile organic carbon (TVOC) Production of polyolefins Any stack with a TVOC mass flow of ≥ 2 kg C/h Generic EN standards Continuous BAT 11, BAT 25 Any stack with a TVOC mass flow of < 2 kg C/h EN 12619 Once every 6 months Production of synthetic rubbers Any stack with a TVOC mass flow of ≥ 2 kg C/h Generic EN standards Continuous BAT 11, BAT 32 Any stack with a TVOC mass flow of < 2 kg C/h EN 12619 Once every 6 months All other processes/sources Any stack with a TVOC mass flow of ≥ 2 kg C/h Generic EN standards Continuous BAT 11 Any stack with a TVOC mass flow of < 2 kg C/h EN 12619 Once every 6 months Grp. 1132. Monitoring Grp. applicability. Recovery may be restricted where the energy demand is excessive due to the low concentration of the compound(s) concerned in the process off-gas(es). Reuse may be restricted due to product quality specifications. Grp. 9. In order to increase resource efficiency and to reduce the mass flow of organic compounds sent to the final waste gas treatment, BAT is to recover organic compounds from process off-gases by using one or a combination of the techniques given below and to reuse them. Technique Description a. Absorption (regenerative) See Section 1.4.1. b. Adsorption (regenerative) See Section 1.4.1. c. Condensation See Section 1.4.1. Grp. description. Process off-gases with a high calorific value are burnt as a fuel in a combustion unit (gas engine, boiler, process heater or furnace) and the heat is recovered as steam or for electricity generation, or to provide heat to the process. For process off-gases with low VOC concentrations (e.g. < 1 g/Nm3), pre-concentration steps may be applied using adsorption (rotor or fixed bed, with activated carbon or zeolites), in order to increase the calorific value of the process off-gases. Molecular sieves (smoothers), typically composed of zeolites, may be used to level down high variations (e.g. concentration peaks) of VOC concentrations in the process off-gases. Grp. applicability. Sending process off-gases to a combustion unit may be restricted due to the presence of contaminants or due to safety considerations. Grp. 10. In order to increase energy efficiency and to reduce the mass flow of organic compounds sent to the final waste gas treatment, BAT is to send process off-gases with a sufficient calorific value to a combustion unit that is, if technically possible, combined with heat recovery. BAT 9 has priority over sending process off-gases to a combustion unit. Grp_11_table. 11. In order to reduce channelled emissions to air of organic compounds, BAT is to use one or a combination of the techniques given below. Technique Description Applicability a. Adsorption See Section 1.4.1. Generally applicable. b. Absorption See Section 1.4.1. Generally applicable. c. Catalytic oxidation See Section 1.4.1. Applicability may be restricted by the presence of catalyst poisons in the waste gases. d. Condensation See Section 1.4.1. Generally applicable. e. Thermal oxidation See Section 1.4.1. Applicability of recuperative and regenerative thermal oxidation to existing plants may be restricted by design and/or operational constraints. Applicability may be restricted where the energy demand is excessive due to the low concentration of the compound(s) concerned in the process off-gases. f. Bioprocesses See Section 1.4.1. Only applicable to the treatment of biodegradable compounds. Substance/Parameter BAT-AEL (mg/Nm3) (Daily average or average over the sampling period) Total volatile organic carbon (TVOC) < 1-20 Sum of VOCs classified as CMR 1A or 1B < 1-5 Sum of VOCs classified as CMR 2 < 1-10 Benzene < 0,5-1 1,3-Butadiene < 0,5-1 Ethylene dichloride < 0,5-1 Ethylene oxide < 0,5-1 Propylene oxide < 0,5-1 Formaldehyde 1-5 Chloromethane < 0,5-1 Dichloromethane < 0,5-1 Tetrachloromethane < 0,5-1 Toluene < 0,5-1 Trichloromethane < 0,5-1 The associated monitoring is given in BAT 8. Grp_12_table. 12. In order to reduce channelled emissions to air of PCDD/F from thermal treatment of waste gases containing chlorine and/or chlorinated compounds, BAT is to use techniques a. and b., and one or a combination of techniques c. to e., given below. Technique Description Applicability Specific techniques to reduce PCDD/F emissions a. Optimised catalytic or thermal oxidation See Section 1.4.1. Generally applicable. b. Rapid waste-gas cooling Rapid cooling of waste gases from temperatures above 400 °C to below 250 °C to prevent the de novo synthesis of PCDD/F. Generally applicable. c. Adsorption using activated carbon See Section 1.4.1. Generally applicable. d. Absorption See Section 1.4.1. Generally applicable. Other techniques not primarily used to reduce PCDD/F emissions e. Selective catalytic reduction (SCR) See Section 1.4.1. When SCR is used for NOX abatement, an adequate catalyst surface of the SCR system also provides for the partial reduction of the emissions of PCDD/F. Applicability to existing plants may be restricted by space availability and/or by the presence of catalyst poisons in the waste gases. Substance/Parameter BAT-AEL (ng I-TEQ/Nm3) (Average over the sampling period) PCDD/F < 0,01-0,05 The associated monitoring is given in BAT 8. Grp. 1133. Organic compounds Grp. applicability. Recovery may be restricted where the energy demand for dust purification or decontamination is excessive. Reuse may be restricted due to product quality specifications. Grp. 13. In order to increase resource efficiency and to reduce the mass flow of dust and particulate-bound metals sent to the final waste gas treatment, BAT is to recover materials from process off-gases by using one or a combination of the techniques given below and to reuse them. Technique Description a. Cyclone See Section 1.4.1. b. Fabric filter See Section 1.4.1. c. Absorption See Section 1.4.1. Grp_14_table. 13. In order to reduce channelled emissions to air of dust and particulate-bound metals, BAT is to use one or a combination of the techniques given below. Technique Description Applicability a. Absolute filter See Section 1.4.1. Applicability may be limited in the case of sticky dust or when the temperature of the waste gases is below the dew point. b. Absorption See Section 1.4.1. Generally applicable. c. Fabric filter See Section 1.4.1. Applicability may be limited in the case of sticky dust or when the temperature of the waste gases is below the dew point. d. High-efficiency air filter See Section 1.4.1. Generally applicable. e. Cyclone See Section 1.4.1. Generally applicable. f. Electrostatic precipitator See Section 1.4.1. Generally applicable. Substance/Parameter BAT-AEL (mg/Nm3) (Daily average or average over the sampling period) Dust < 1-5 Lead and its compounds, expressed as Pb < 0,01-0,1 Nickel and its compounds, expressed as Ni < 0,02-0,1 The associated monitoring is given in BAT 8. Grp. 1134. Dust (including PM10 and PM2,5) and particulate-bound metals Grp. description. See Section 1.4.1. Grp. applicability. Recovery may be restricted where the energy demand is excessive due to the low concentration of the compound(s) concerned in the process off-gas(es). Reuse may be restricted due to product quality specifications. Grp. 15. In order to increase resource efficiency and to reduce the mass flow of inorganic compounds sent to the final waste gas treatment, BAT is to recover inorganic compounds from process off-gases by using absorption and to reuse them. Grp_16_table. 14. In order to reduce channelled emissions to air of CO, NOX and SOX from thermal treatment, BAT is to use technique c. and one or a combination of the other techniques given below. Technique Description Main inorganic compounds targeted Applicability a. Choice of fuel See Section 1.4.1. NOX, SOX Generally applicable. b. Low-NOX burner See Section 1.4.1. NOX Applicability to existing plants may be restricted by design and/or operational constraints. c. Optimisation of catalytic or thermal oxidation See Section 1.4.1. CO, NOX Generally applicable. d. Removal of high levels of NOX precursors Remove (if possible, for reuse) high levels of NOX precursors prior to thermal or catalytic oxidation, e.g. by absorption, adsorption or condensation. NOX Generally applicable. e. Absorption See Section 1.4.1. SOX Generally applicable. f. Selective catalytic reduction (SCR) See Section 1.4.1. NOX Applicability to existing plants may be restricted by space availability. g. Selective non-catalytic reduction (SNCR) See Section 1.4.1. NOX Applicability to existing plants may be restricted by the residence time needed for the reaction. Substance/Parameter BAT-AEL (mg/Nm3) (Daily average or average over the sampling period) Nitrogen oxides (NOX) from catalytic oxidation 5-30 Nitrogen oxides (NOX) from thermal oxidation 5-130 Carbon monoxide (CO) No BAT-AEL The associated monitoring is given in BAT 8. The BAT-AEL for channelled emissions to air of SO2 is given in Table 1.6. Grp_17_table. 15. In order to reduce channelled emissions to air of ammonia from the use of selective catalytic reduction (SCR) or selective non-catalytic reduction (SNCR) for the abatement of NOX emissions (ammonia slip), BAT is to optimise the design and/or operation of SCR or SNCR (e.g. optimised reagent to NOX ratio, homogeneous reagent distribution and optimum size of the reagent drops). Substance/Parameter BAT-AEL (mg/Nm3) (Average over the sampling period) Ammonia (NH3) from SCR/SNCR < 0,5-8 The associated monitoring is given in BAT 8. Grp_18_table. 16. In order to reduce channelled emissions to air of inorganic compounds other than channelled emissions to air of ammonia from the use of selective catalytic reduction (SCR) or selective non-catalytic reduction (SNCR) for the abatement of NOX emissions), channelled emissions to air of CO, NOX and SOX from the use of thermal treatment, and channelled emissions to air of NOX from process furnaces/heaters, BAT is to use one or a combination of the techniques given below. Technique Description Main inorganic compounds targeted Applicability Specific techniques to reduce emissions to air of inorganic compounds a. Absorption See Section 1.4.1. Cl2, HCl, HCN, HF, NH3, NOX, SOX Generally applicable. b. Adsorption See Section 1.4.1. For the removal of inorganic substances, the technique is often used in combination with a dust abatement technique (see BAT 14). HCl, HF, NH3, SOX Generally applicable. c. Selective catalytic reduction (SCR) See Section 1.4.1. NOX Applicability to existing plants may be restricted by space availability. d. Selective non-catalytic reduction (SNCR) See Section 1.4.1. NOX Applicability to existing plants may be restricted by the residence time needed for the reaction. Other techniques not primarily used to reduce emissions to air of inorganic compounds e. Catalytic oxidation See Section 1.4.1. NH3 Applicability may be restricted by the presence of catalyst poisons in the waste gases. f. Thermal oxidation See Section 1.4.1. NH3, HCN Applicability of recuperative and regenerative thermal oxidation to existing plants may be restricted by design and/or operational constraints. The applicability may be restricted where the energy demand is excessive due to the low concentration of the compound(s) concerned in the process off-gases. Substance/Parameter BAT-AEL (mg/Nm3) (Daily average or average over the sampling period) Ammonia (NH3) 2-10 Elemental chlorine (Cl2) < 0,5-2 Gaseous fluorides, expressed as HF ≤ 1 Hydrogen cyanide (HCN) < 0,1-1 Gaseous chlorides, expressed as HCl 1-10 Nitrogen oxides (NOX) 10-150 Sulphur oxides (SO2) < 3-150 The associated monitoring is given in BAT 8. Grp. 1135. Inorganic compounds
1.1.3.
1.1.3.1. General techniques Grp. description. The integrated waste gas management and treatment strategy is based on the inventory in BAT 2. It takes into account factors such as greenhouse gas emissions and the consumption or reuse of energy, water and materials associated with the use of the different techniques. Grp. 4. In order to reduce channelled emissions to air, BAT is to use an integrated waste gas management and treatment strategy that includes, in order of priority, process-integrated recovery and abatement techniques. Grp. description. The combined treatment of waste gases with similar characteristics ensures more effective and efficient treatment compared to the separate treatment of individual waste gas streams. The combination of waste gases is carried out considering plant safety (e.g. avoiding concentrations close to the lower/upper explosive limit), technical (e.g. compatibility of the individual waste gas streams, concentration of the substances concerned), environmental (e.g. maximising recovery of materials or pollutant abatement) and economic factors (e.g. distance between different production units). Care is taken that the combination of waste gases does not lead to the dilution of emissions. Grp. 5. In order to facilitate the recovery of materials and the reduction of channelled emissions to air, as well as to increase energy efficiency, BAT is to combine waste gas streams with similar characteristics, thus minimising the number of emission points. Grp. 6. In order to reduce channelled emissions to air, BAT is to ensure that the waste gas treatment systems are appropriately designed (e.g. considering the maximum flow rate and pollutant concentrations), operated within their design ranges, and maintained (through preventive, corrective, regular and unplanned maintenance) so as to ensure optimal availability, effectiveness and efficiency of the equipment.
1.1.3.1.
BAT 4. In order to reduce channelled emissions to air, BAT is to use an integrated waste gas management and treatment strategy that includes, in order of priority, process-integrated recovery and abatement techniques. Grp. description. The integrated waste gas management and treatment strategy is based on the inventory in BAT 2. It takes into account factors such as greenhouse gas emissions and the consumption or reuse of energy, water and materials associated with the use of the different techniques.
BAT 4. Description
The integrated waste gas management and treatment strategy is based on the inventory in BAT 2. It takes into account factors such as greenhouse gas emissions and the consumption or reuse of energy, water and materials associated with the use of the different techniques.
BAT 5. In order to facilitate the recovery of materials and the reduction of channelled emissions to air, as well as to increase energy efficiency, BAT is to combine waste gas streams with similar characteristics, thus minimising the number of emission points. Grp. description. The combined treatment of waste gases with similar characteristics ensures more effective and efficient treatment compared to the separate treatment of individual waste gas streams. The combination of waste gases is carried out considering plant safety (e.g. avoiding concentrations close to the lower/upper explosive limit), technical (e.g. compatibility of the individual waste gas streams, concentration of the substances concerned), environmental (e.g. maximising recovery of materials or pollutant abatement) and economic factors (e.g. distance between different production units). Care is taken that the combination of waste gases does not lead to the dilution of emissions.
BAT 5. Description
The combined treatment of waste gases with similar characteristics ensures more effective and efficient treatment compared to the separate treatment of individual waste gas streams. The combination of waste gases is carried out considering plant safety (e.g. avoiding concentrations close to the lower/upper explosive limit), technical (e.g. compatibility of the individual waste gas streams, concentration of the substances concerned), environmental (e.g. maximising recovery of materials or pollutant abatement) and economic factors (e.g. distance between different production units). Care is taken that the combination of waste gases does not lead to the dilution of emissions.
BAT 6. In order to reduce channelled emissions to air, BAT is to ensure that the waste gas treatment systems are appropriately designed (e.g. considering the maximum flow rate and pollutant concentrations), operated within their design ranges, and maintained (through preventive, corrective, regular and unplanned maintenance) so as to ensure optimal availability, effectiveness and efficiency of the equipment.
1.1.3.2. Monitoring Grp. 7. BAT is to continuously monitor key process parameters (e.g. waste gas flow and temperature) of waste gas streams being sent to pretreatment and/or final treatment. Grp. 8. BAT is to monitor channelled emissions to air with at least the frequency given below and in accordance with EN standards. If EN standards are not available, BAT is to use ISO, national or other international standards that ensure the provision of data of an equivalent scientific quality. Substance/Parameter Process(es)/Source(s) Emission points Standard(s) Minimum monitoring frequency Monitoring associated with Ammonia (NH3) Use of SCR/SNCR Any stack EN 21877 Once every 6 months BAT 17 All other processes/sources BAT 18 Benzene All processes/sources Any stack No EN standard available Once every 6 months BAT 11 1,3-Butadiene All processes/sources Any stack No EN standard available Once every 6 months BAT 11 Carbon monoxide (CO) Thermal treatment Any stack with a CO mass flow of ≥ 2 kg/h Generic EN standards Continuous BAT 16 Any stack with a CO mass flow of < 2 kg/h EN 15058 Once every 6 months Process furnaces/heaters Any stack with a CO mass flow of ≥ 2 kg/h Generic EN standards Continuous BAT 36 Any stack with a CO mass flow of < 2 kg/h EN 15058 Once every 6 months All other processes/sources Any stack with a CO mass flow of ≥ 2 kg/h Generic EN standards Continuous BAT 18 Any stack with a CO mass flow of < 2 kg/h EN 15058 Once every year Chloromethane All processes/sources Any stack No EN standard available Once every 6 months BAT 11 CMR substances other than CMR substances covered elsewhere in this table All other processes/sources Any stack No EN standard available Once every 6 months BAT 11 Dichloromethane All processes/sources Any stack No EN standard available Once every 6 months BAT 11 Dust All processes/sources Any stack with dust mass flow ≥ 3 kg/h Generic EN standards, EN 13284-1 and EN 13284-2 Continuous BAT 14 Any stack with dust mass flow < 3 kg/h EN 13284-1 Once every year Elemental chlorine (Cl2) All processes/sources Any stack No EN standard available Once every year BAT 18 Ethylene dichloride (EDC) All processes/sources Any stack No EN standard available Once every 6 months BAT 11 Ethylene oxide All processes/sources Any stack No EN standard available Once every 6 months BAT 11 Formaldehyde All processes/sources Any stack EN standard under development Once every 6 months BAT 11 Gaseous chlorides All processes/sources Any stack EN 1911 Once every year BAT 18 Gaseous fluorides All processes/sources Any stack No EN standard available Once every year BAT 18 Hydrogen cyanide (HCN) All processes/sources Any stack No EN standard available Once every year BAT 18 Lead and its compounds All processes/sources Any stack EN 14385 Once every 6 months BAT 14 Nickel and its compounds All processes/sources Any stack EN 14385 Once every 6 months BAT 14 Nitrous oxide (N2O) All processes/sources Any stack EN ISO 21258 Once every year – Nitrogen oxides (NOX) Thermal treatment Any stack with a NOX mass flow of ≥ 2,5 kg/h Generic EN standards Continuous BAT 16 Any stack with a NOX mass flow of < 2,5 kg/h EN 14792 Once every 6 months Process furnaces/heaters Any stack with a NOX mass flow of ≥ 2,5 kg/h Generic EN standards Continuous BAT 36 Any stack with a NOX mass flow of < 2,5 kg/h EN 14792 Once every 6 months All other processes/sources Any stack with a NOX mass flow of ≥ 2,5 kg/h Generic EN standards Continuous BAT 18 Any stack with a NOX mass flow of < 2,5 kg/h EN 14792 Once every 6 months PCDD/F Thermal treatment Any stack EN 1948-1, EN 1948-2, EN 1948-3 Once every 6 months BAT 12 PM2,5 and PM10 All processes/sources Any stack EN ISO 23210 Once every year BAT 14 Propylene oxide All processes/sources Any stack No EN standard available Once every 6 months BAT 11 Sulphur dioxide (SO2) Thermal treatment Any stack with a SO2 mass flow of ≥ 2,5 kg/h Generic EN standards Continuous BAT 16 Any stack with a SO2 mass flow of < 2,5 kg/h EN 14791 Once every 6 months Process furnaces/heaters Any stack with a SO2 mass flow of ≥ 2,5 kg/h Generic EN standards Continuous BAT 18, BAT 36 Any stack with a SO2 mass flow of < 2,5 kg/h EN 14791 Once every 6 months All other processes/sources Any stack with a SO2 mass flow of ≥ 2,5 kg/h Generic EN standards Continuous BAT 18 Any stack with a SO2 mass flow of < 2,5 kg/h EN 14791 Once every 6 months Tetrachloromethane All processes/sources Any stack No EN standard available Once every 6 months BAT 11 Toluene All processes/sources Any stack No EN standard available Once every 6 months BAT 11 Trichloromethane All processes/sources Any stack No EN standard available Once every 6 months BAT 11 Total volatile organic carbon (TVOC) Production of polyolefins Any stack with a TVOC mass flow of ≥ 2 kg C/h Generic EN standards Continuous BAT 11, BAT 25 Any stack with a TVOC mass flow of < 2 kg C/h EN 12619 Once every 6 months Production of synthetic rubbers Any stack with a TVOC mass flow of ≥ 2 kg C/h Generic EN standards Continuous BAT 11, BAT 32 Any stack with a TVOC mass flow of < 2 kg C/h EN 12619 Once every 6 months All other processes/sources Any stack with a TVOC mass flow of ≥ 2 kg C/h Generic EN standards Continuous BAT 11 Any stack with a TVOC mass flow of < 2 kg C/h EN 12619 Once every 6 months
1.1.3.2.
BAT 7. BAT is to continuously monitor key process parameters (e.g. waste gas flow and temperature) of waste gas streams being sent to pretreatment and/or final treatment.
BAT 8. BAT is to monitor channelled emissions to air with at least the frequency given below and in accordance with EN standards. If EN standards are not available, BAT is to use ISO, national or other international standards that ensure the provision of data of an equivalent scientific quality. Substance/Parameter Process(es)/Source(s) Emission points Standard(s) Minimum monitoring frequency Monitoring associated with Ammonia (NH3) Use of SCR/SNCR Any stack EN 21877 Once every 6 months BAT 17 All other processes/sources BAT 18 Benzene All processes/sources Any stack No EN standard available Once every 6 months BAT 11 1,3-Butadiene All processes/sources Any stack No EN standard available Once every 6 months BAT 11 Carbon monoxide (CO) Thermal treatment Any stack with a CO mass flow of ≥ 2 kg/h Generic EN standards Continuous BAT 16 Any stack with a CO mass flow of < 2 kg/h EN 15058 Once every 6 months Process furnaces/heaters Any stack with a CO mass flow of ≥ 2 kg/h Generic EN standards Continuous BAT 36 Any stack with a CO mass flow of < 2 kg/h EN 15058 Once every 6 months All other processes/sources Any stack with a CO mass flow of ≥ 2 kg/h Generic EN standards Continuous BAT 18 Any stack with a CO mass flow of < 2 kg/h EN 15058 Once every year Chloromethane All processes/sources Any stack No EN standard available Once every 6 months BAT 11 CMR substances other than CMR substances covered elsewhere in this table All other processes/sources Any stack No EN standard available Once every 6 months BAT 11 Dichloromethane All processes/sources Any stack No EN standard available Once every 6 months BAT 11 Dust All processes/sources Any stack with dust mass flow ≥ 3 kg/h Generic EN standards, EN 13284-1 and EN 13284-2 Continuous BAT 14 Any stack with dust mass flow < 3 kg/h EN 13284-1 Once every year Elemental chlorine (Cl2) All processes/sources Any stack No EN standard available Once every year BAT 18 Ethylene dichloride (EDC) All processes/sources Any stack No EN standard available Once every 6 months BAT 11 Ethylene oxide All processes/sources Any stack No EN standard available Once every 6 months BAT 11 Formaldehyde All processes/sources Any stack EN standard under development Once every 6 months BAT 11 Gaseous chlorides All processes/sources Any stack EN 1911 Once every year BAT 18 Gaseous fluorides All processes/sources Any stack No EN standard available Once every year BAT 18 Hydrogen cyanide (HCN) All processes/sources Any stack No EN standard available Once every year BAT 18 Lead and its compounds All processes/sources Any stack EN 14385 Once every 6 months BAT 14 Nickel and its compounds All processes/sources Any stack EN 14385 Once every 6 months BAT 14 Nitrous oxide (N2O) All processes/sources Any stack EN ISO 21258 Once every year – Nitrogen oxides (NOX) Thermal treatment Any stack with a NOX mass flow of ≥ 2,5 kg/h Generic EN standards Continuous BAT 16 Any stack with a NOX mass flow of < 2,5 kg/h EN 14792 Once every 6 months Process furnaces/heaters Any stack with a NOX mass flow of ≥ 2,5 kg/h Generic EN standards Continuous BAT 36 Any stack with a NOX mass flow of < 2,5 kg/h EN 14792 Once every 6 months All other processes/sources Any stack with a NOX mass flow of ≥ 2,5 kg/h Generic EN standards Continuous BAT 18 Any stack with a NOX mass flow of < 2,5 kg/h EN 14792 Once every 6 months PCDD/F Thermal treatment Any stack EN 1948-1, EN 1948-2, EN 1948-3 Once every 6 months BAT 12 PM2,5 and PM10 All processes/sources Any stack EN ISO 23210 Once every year BAT 14 Propylene oxide All processes/sources Any stack No EN standard available Once every 6 months BAT 11 Sulphur dioxide (SO2) Thermal treatment Any stack with a SO2 mass flow of ≥ 2,5 kg/h Generic EN standards Continuous BAT 16 Any stack with a SO2 mass flow of < 2,5 kg/h EN 14791 Once every 6 months Process furnaces/heaters Any stack with a SO2 mass flow of ≥ 2,5 kg/h Generic EN standards Continuous BAT 18, BAT 36 Any stack with a SO2 mass flow of < 2,5 kg/h EN 14791 Once every 6 months All other processes/sources Any stack with a SO2 mass flow of ≥ 2,5 kg/h Generic EN standards Continuous BAT 18 Any stack with a SO2 mass flow of < 2,5 kg/h EN 14791 Once every 6 months Tetrachloromethane All processes/sources Any stack No EN standard available Once every 6 months BAT 11 Toluene All processes/sources Any stack No EN standard available Once every 6 months BAT 11 Trichloromethane All processes/sources Any stack No EN standard available Once every 6 months BAT 11 Total volatile organic carbon (TVOC) Production of polyolefins Any stack with a TVOC mass flow of ≥ 2 kg C/h Generic EN standards Continuous BAT 11, BAT 25 Any stack with a TVOC mass flow of < 2 kg C/h EN 12619 Once every 6 months Production of synthetic rubbers Any stack with a TVOC mass flow of ≥ 2 kg C/h Generic EN standards Continuous BAT 11, BAT 32 Any stack with a TVOC mass flow of < 2 kg C/h EN 12619 Once every 6 months All other processes/sources Any stack with a TVOC mass flow of ≥ 2 kg C/h Generic EN standards Continuous BAT 11 Any stack with a TVOC mass flow of < 2 kg C/h EN 12619 Once every 6 months
1.1.3.3. Organic compounds Grp. applicability. Recovery may be restricted where the energy demand is excessive due to the low concentration of the compound(s) concerned in the process off-gas(es). Reuse may be restricted due to product quality specifications. Grp. 9. In order to increase resource efficiency and to reduce the mass flow of organic compounds sent to the final waste gas treatment, BAT is to recover organic compounds from process off-gases by using one or a combination of the techniques given below and to reuse them. Technique Description a. Absorption (regenerative) See Section 1.4.1. b. Adsorption (regenerative) See Section 1.4.1. c. Condensation See Section 1.4.1. Grp. description. Process off-gases with a high calorific value are burnt as a fuel in a combustion unit (gas engine, boiler, process heater or furnace) and the heat is recovered as steam or for electricity generation, or to provide heat to the process. For process off-gases with low VOC concentrations (e.g. < 1 g/Nm3), pre-concentration steps may be applied using adsorption (rotor or fixed bed, with activated carbon or zeolites), in order to increase the calorific value of the process off-gases. Molecular sieves (smoothers), typically composed of zeolites, may be used to level down high variations (e.g. concentration peaks) of VOC concentrations in the process off-gases. Grp. applicability. Sending process off-gases to a combustion unit may be restricted due to the presence of contaminants or due to safety considerations. Grp. 10. In order to increase energy efficiency and to reduce the mass flow of organic compounds sent to the final waste gas treatment, BAT is to send process off-gases with a sufficient calorific value to a combustion unit that is, if technically possible, combined with heat recovery. BAT 9 has priority over sending process off-gases to a combustion unit. Grp_11_table. 11. In order to reduce channelled emissions to air of organic compounds, BAT is to use one or a combination of the techniques given below. Technique Description Applicability a. Adsorption See Section 1.4.1. Generally applicable. b. Absorption See Section 1.4.1. Generally applicable. c. Catalytic oxidation See Section 1.4.1. Applicability may be restricted by the presence of catalyst poisons in the waste gases. d. Condensation See Section 1.4.1. Generally applicable. e. Thermal oxidation See Section 1.4.1. Applicability of recuperative and regenerative thermal oxidation to existing plants may be restricted by design and/or operational constraints. Applicability may be restricted where the energy demand is excessive due to the low concentration of the compound(s) concerned in the process off-gases. f. Bioprocesses See Section 1.4.1. Only applicable to the treatment of biodegradable compounds. Substance/Parameter BAT-AEL (mg/Nm3) (Daily average or average over the sampling period) Total volatile organic carbon (TVOC) < 1-20 Sum of VOCs classified as CMR 1A or 1B < 1-5 Sum of VOCs classified as CMR 2 < 1-10 Benzene < 0,5-1 1,3-Butadiene < 0,5-1 Ethylene dichloride < 0,5-1 Ethylene oxide < 0,5-1 Propylene oxide < 0,5-1 Formaldehyde 1-5 Chloromethane < 0,5-1 Dichloromethane < 0,5-1 Tetrachloromethane < 0,5-1 Toluene < 0,5-1 Trichloromethane < 0,5-1 The associated monitoring is given in BAT 8. Grp_12_table. 12. In order to reduce channelled emissions to air of PCDD/F from thermal treatment of waste gases containing chlorine and/or chlorinated compounds, BAT is to use techniques a. and b., and one or a combination of techniques c. to e., given below. Technique Description Applicability Specific techniques to reduce PCDD/F emissions a. Optimised catalytic or thermal oxidation See Section 1.4.1. Generally applicable. b. Rapid waste-gas cooling Rapid cooling of waste gases from temperatures above 400 °C to below 250 °C to prevent the de novo synthesis of PCDD/F. Generally applicable. c. Adsorption using activated carbon See Section 1.4.1. Generally applicable. d. Absorption See Section 1.4.1. Generally applicable. Other techniques not primarily used to reduce PCDD/F emissions e. Selective catalytic reduction (SCR) See Section 1.4.1. When SCR is used for NOX abatement, an adequate catalyst surface of the SCR system also provides for the partial reduction of the emissions of PCDD/F. Applicability to existing plants may be restricted by space availability and/or by the presence of catalyst poisons in the waste gases. Substance/Parameter BAT-AEL (ng I-TEQ/Nm3) (Average over the sampling period) PCDD/F < 0,01-0,05 The associated monitoring is given in BAT 8.
1.1.3.3.
BAT 9. In order to increase resource efficiency and to reduce the mass flow of organic compounds sent to the final waste gas treatment, BAT is to recover organic compounds from process off-gases by using one or a combination of the techniques given below and to reuse them. Technique Description a. Absorption (regenerative) See Section 1.4.1. b. Adsorption (regenerative) See Section 1.4.1. c. Condensation See Section 1.4.1. Grp. applicability. Recovery may be restricted where the energy demand is excessive due to the low concentration of the compound(s) concerned in the process off-gas(es). Reuse may be restricted due to product quality specifications.
BAT 9. Applicability
Recovery may be restricted where the energy demand is excessive due to the low concentration of the compound(s) concerned in the process off-gas(es). Reuse may be restricted due to product quality specifications.
BAT 10. In order to increase energy efficiency and to reduce the mass flow of organic compounds sent to the final waste gas treatment, BAT is to send process off-gases with a sufficient calorific value to a combustion unit that is, if technically possible, combined with heat recovery. BAT 9 has priority over sending process off-gases to a combustion unit. Grp. description. Process off-gases with a high calorific value are burnt as a fuel in a combustion unit (gas engine, boiler, process heater or furnace) and the heat is recovered as steam or for electricity generation, or to provide heat to the process. For process off-gases with low VOC concentrations (e.g. < 1 g/Nm3), pre-concentration steps may be applied using adsorption (rotor or fixed bed, with activated carbon or zeolites), in order to increase the calorific value of the process off-gases. Molecular sieves (smoothers), typically composed of zeolites, may be used to level down high variations (e.g. concentration peaks) of VOC concentrations in the process off-gases. Grp. applicability. Sending process off-gases to a combustion unit may be restricted due to the presence of contaminants or due to safety considerations.
BAT 10. Description
Process off-gases with a high calorific value are burnt as a fuel in a combustion unit (gas engine, boiler, process heater or furnace) and the heat is recovered as steam or for electricity generation, or to provide heat to the process. For process off-gases with low VOC concentrations (e.g. < 1 g/Nm3), pre-concentration steps may be applied using adsorption (rotor or fixed bed, with activated carbon or zeolites), in order to increase the calorific value of the process off-gases. Molecular sieves (smoothers), typically composed of zeolites, may be used to level down high variations (e.g. concentration peaks) of VOC concentrations in the process off-gases.
Applicability
Sending process off-gases to a combustion unit may be restricted due to the presence of contaminants or due to safety considerations.
BAT 11. Table 1.1 BAT-associated emission levels (BAT-AELs) for channelled emissions to air of organic compounds
In order to reduce channelled emissions to air of organic compounds, BAT is to use one or a combination of the techniques given below. Technique Description Applicability a. Adsorption See Section 1.4.1. Generally applicable. b. Absorption See Section 1.4.1. Generally applicable. c. Catalytic oxidation See Section 1.4.1. Applicability may be restricted by the presence of catalyst poisons in the waste gases. d. Condensation See Section 1.4.1. Generally applicable. e. Thermal oxidation See Section 1.4.1. Applicability of recuperative and regenerative thermal oxidation to existing plants may be restricted by design and/or operational constraints. Applicability may be restricted where the energy demand is excessive due to the low concentration of the compound(s) concerned in the process off-gases. f. Bioprocesses See Section 1.4.1. Only applicable to the treatment of biodegradable compounds. Substance/Parameter BAT-AEL (mg/Nm3) (Daily average or average over the sampling period) Total volatile organic carbon (TVOC) < 1-20 Sum of VOCs classified as CMR 1A or 1B < 1-5 Sum of VOCs classified as CMR 2 < 1-10 Benzene < 0,5-1 1,3-Butadiene < 0,5-1 Ethylene dichloride < 0,5-1 Ethylene oxide < 0,5-1 Propylene oxide < 0,5-1 Formaldehyde 1-5 Chloromethane < 0,5-1 Dichloromethane < 0,5-1 Tetrachloromethane < 0,5-1 Toluene < 0,5-1 Trichloromethane < 0,5-1 The associated monitoring is given in BAT 8.
BAT 12. Table 1.2 BAT-associated emission level (BAT-AEL) for channelled emissions to air of PCDD/F from thermal treatment of waste gases containing chlorine and/or chlorinated compounds
In order to reduce channelled emissions to air of PCDD/F from thermal treatment of waste gases containing chlorine and/or chlorinated compounds, BAT is to use techniques a. and b., and one or a combination of techniques c. to e., given below. Technique Description Applicability Specific techniques to reduce PCDD/F emissions a. Optimised catalytic or thermal oxidation See Section 1.4.1. Generally applicable. b. Rapid waste-gas cooling Rapid cooling of waste gases from temperatures above 400 °C to below 250 °C to prevent the de novo synthesis of PCDD/F. Generally applicable. c. Adsorption using activated carbon See Section 1.4.1. Generally applicable. d. Absorption See Section 1.4.1. Generally applicable. Other techniques not primarily used to reduce PCDD/F emissions e. Selective catalytic reduction (SCR) See Section 1.4.1. When SCR is used for NOX abatement, an adequate catalyst surface of the SCR system also provides for the partial reduction of the emissions of PCDD/F. Applicability to existing plants may be restricted by space availability and/or by the presence of catalyst poisons in the waste gases. Substance/Parameter BAT-AEL (ng I-TEQ/Nm3) (Average over the sampling period) PCDD/F < 0,01-0,05 The associated monitoring is given in BAT 8.
1.1.3.4. Dust (including PM10 and PM2,5) and particulate-bound metals Grp. applicability. Recovery may be restricted where the energy demand for dust purification or decontamination is excessive. Reuse may be restricted due to product quality specifications. Grp. 13. In order to increase resource efficiency and to reduce the mass flow of dust and particulate-bound metals sent to the final waste gas treatment, BAT is to recover materials from process off-gases by using one or a combination of the techniques given below and to reuse them. Technique Description a. Cyclone See Section 1.4.1. b. Fabric filter See Section 1.4.1. c. Absorption See Section 1.4.1. Grp_14_table. 13. In order to reduce channelled emissions to air of dust and particulate-bound metals, BAT is to use one or a combination of the techniques given below. Technique Description Applicability a. Absolute filter See Section 1.4.1. Applicability may be limited in the case of sticky dust or when the temperature of the waste gases is below the dew point. b. Absorption See Section 1.4.1. Generally applicable. c. Fabric filter See Section 1.4.1. Applicability may be limited in the case of sticky dust or when the temperature of the waste gases is below the dew point. d. High-efficiency air filter See Section 1.4.1. Generally applicable. e. Cyclone See Section 1.4.1. Generally applicable. f. Electrostatic precipitator See Section 1.4.1. Generally applicable. Substance/Parameter BAT-AEL (mg/Nm3) (Daily average or average over the sampling period) Dust < 1-5 Lead and its compounds, expressed as Pb < 0,01-0,1 Nickel and its compounds, expressed as Ni < 0,02-0,1 The associated monitoring is given in BAT 8.
1.1.3.4.
BAT 13. In order to increase resource efficiency and to reduce the mass flow of dust and particulate-bound metals sent to the final waste gas treatment, BAT is to recover materials from process off-gases by using one or a combination of the techniques given below and to reuse them. Technique Description a. Cyclone See Section 1.4.1. b. Fabric filter See Section 1.4.1. c. Absorption See Section 1.4.1. Grp. applicability. Recovery may be restricted where the energy demand for dust purification or decontamination is excessive. Reuse may be restricted due to product quality specifications.
BAT 13. Applicability
Recovery may be restricted where the energy demand for dust purification or decontamination is excessive. Reuse may be restricted due to product quality specifications.
BAT 14. Table 1.3 BAT-associated emission levels (BAT-AELs) for channelled emissions to air of dust, lead and nickel
In order to reduce channelled emissions to air of dust and particulate-bound metals, BAT is to use one or a combination of the techniques given below. Technique Description Applicability a. Absolute filter See Section 1.4.1. Applicability may be limited in the case of sticky dust or when the temperature of the waste gases is below the dew point. b. Absorption See Section 1.4.1. Generally applicable. c. Fabric filter See Section 1.4.1. Applicability may be limited in the case of sticky dust or when the temperature of the waste gases is below the dew point. d. High-efficiency air filter See Section 1.4.1. Generally applicable. e. Cyclone See Section 1.4.1. Generally applicable. f. Electrostatic precipitator See Section 1.4.1. Generally applicable. Substance/Parameter BAT-AEL (mg/Nm3) (Daily average or average over the sampling period) Dust < 1-5 Lead and its compounds, expressed as Pb < 0,01-0,1 Nickel and its compounds, expressed as Ni < 0,02-0,1 The associated monitoring is given in BAT 8.
1.1.3.5. Inorganic compounds Grp. description. See Section 1.4.1. Grp. applicability. Recovery may be restricted where the energy demand is excessive due to the low concentration of the compound(s) concerned in the process off-gas(es). Reuse may be restricted due to product quality specifications. Grp. 15. In order to increase resource efficiency and to reduce the mass flow of inorganic compounds sent to the final waste gas treatment, BAT is to recover inorganic compounds from process off-gases by using absorption and to reuse them. Grp_16_table. 14. In order to reduce channelled emissions to air of CO, NOX and SOX from thermal treatment, BAT is to use technique c. and one or a combination of the other techniques given below. Technique Description Main inorganic compounds targeted Applicability a. Choice of fuel See Section 1.4.1. NOX, SOX Generally applicable. b. Low-NOX burner See Section 1.4.1. NOX Applicability to existing plants may be restricted by design and/or operational constraints. c. Optimisation of catalytic or thermal oxidation See Section 1.4.1. CO, NOX Generally applicable. d. Removal of high levels of NOX precursors Remove (if possible, for reuse) high levels of NOX precursors prior to thermal or catalytic oxidation, e.g. by absorption, adsorption or condensation. NOX Generally applicable. e. Absorption See Section 1.4.1. SOX Generally applicable. f. Selective catalytic reduction (SCR) See Section 1.4.1. NOX Applicability to existing plants may be restricted by space availability. g. Selective non-catalytic reduction (SNCR) See Section 1.4.1. NOX Applicability to existing plants may be restricted by the residence time needed for the reaction. Substance/Parameter BAT-AEL (mg/Nm3) (Daily average or average over the sampling period) Nitrogen oxides (NOX) from catalytic oxidation 5-30 Nitrogen oxides (NOX) from thermal oxidation 5-130 Carbon monoxide (CO) No BAT-AEL The associated monitoring is given in BAT 8. The BAT-AEL for channelled emissions to air of SO2 is given in Table 1.6. Grp_17_table. 15. In order to reduce channelled emissions to air of ammonia from the use of selective catalytic reduction (SCR) or selective non-catalytic reduction (SNCR) for the abatement of NOX emissions (ammonia slip), BAT is to optimise the design and/or operation of SCR or SNCR (e.g. optimised reagent to NOX ratio, homogeneous reagent distribution and optimum size of the reagent drops). Substance/Parameter BAT-AEL (mg/Nm3) (Average over the sampling period) Ammonia (NH3) from SCR/SNCR < 0,5-8 The associated monitoring is given in BAT 8. Grp_18_table. 16. In order to reduce channelled emissions to air of inorganic compounds other than channelled emissions to air of ammonia from the use of selective catalytic reduction (SCR) or selective non-catalytic reduction (SNCR) for the abatement of NOX emissions), channelled emissions to air of CO, NOX and SOX from the use of thermal treatment, and channelled emissions to air of NOX from process furnaces/heaters, BAT is to use one or a combination of the techniques given below. Technique Description Main inorganic compounds targeted Applicability Specific techniques to reduce emissions to air of inorganic compounds a. Absorption See Section 1.4.1. Cl2, HCl, HCN, HF, NH3, NOX, SOX Generally applicable. b. Adsorption See Section 1.4.1. For the removal of inorganic substances, the technique is often used in combination with a dust abatement technique (see BAT 14). HCl, HF, NH3, SOX Generally applicable. c. Selective catalytic reduction (SCR) See Section 1.4.1. NOX Applicability to existing plants may be restricted by space availability. d. Selective non-catalytic reduction (SNCR) See Section 1.4.1. NOX Applicability to existing plants may be restricted by the residence time needed for the reaction. Other techniques not primarily used to reduce emissions to air of inorganic compounds e. Catalytic oxidation See Section 1.4.1. NH3 Applicability may be restricted by the presence of catalyst poisons in the waste gases. f. Thermal oxidation See Section 1.4.1. NH3, HCN Applicability of recuperative and regenerative thermal oxidation to existing plants may be restricted by design and/or operational constraints. The applicability may be restricted where the energy demand is excessive due to the low concentration of the compound(s) concerned in the process off-gases. Substance/Parameter BAT-AEL (mg/Nm3) (Daily average or average over the sampling period) Ammonia (NH3) 2-10 Elemental chlorine (Cl2) < 0,5-2 Gaseous fluorides, expressed as HF ≤ 1 Hydrogen cyanide (HCN) < 0,1-1 Gaseous chlorides, expressed as HCl 1-10 Nitrogen oxides (NOX) 10-150 Sulphur oxides (SO2) < 3-150 The associated monitoring is given in BAT 8.
1.1.3.5.
BAT 15. In order to increase resource efficiency and to reduce the mass flow of inorganic compounds sent to the final waste gas treatment, BAT is to recover inorganic compounds from process off-gases by using absorption and to reuse them. Grp. description. See Section 1.4.1. Grp. applicability. Recovery may be restricted where the energy demand is excessive due to the low concentration of the compound(s) concerned in the process off-gas(es). Reuse may be restricted due to product quality specifications.
BAT 15. Description
See Section 1.4.1.
Applicability
Recovery may be restricted where the energy demand is excessive due to the low concentration of the compound(s) concerned in the process off-gas(es). Reuse may be restricted due to product quality specifications.
BAT 16. Table 1.4 BAT-associated emission levels (BAT-AELs) for channelled emissions to air of NOX and indicative emission level for channelled emissions to air of CO from thermal treatment
In order to reduce channelled emissions to air of CO, NOX and SOX from thermal treatment, BAT is to use technique c. and one or a combination of the other techniques given below. Technique Description Main inorganic compounds targeted Applicability a. Choice of fuel See Section 1.4.1. NOX, SOX Generally applicable. b. Low-NOX burner See Section 1.4.1. NOX Applicability to existing plants may be restricted by design and/or operational constraints. c. Optimisation of catalytic or thermal oxidation See Section 1.4.1. CO, NOX Generally applicable. d. Removal of high levels of NOX precursors Remove (if possible, for reuse) high levels of NOX precursors prior to thermal or catalytic oxidation, e.g. by absorption, adsorption or condensation. NOX Generally applicable. e. Absorption See Section 1.4.1. SOX Generally applicable. f. Selective catalytic reduction (SCR) See Section 1.4.1. NOX Applicability to existing plants may be restricted by space availability. g. Selective non-catalytic reduction (SNCR) See Section 1.4.1. NOX Applicability to existing plants may be restricted by the residence time needed for the reaction. Substance/Parameter BAT-AEL (mg/Nm3) (Daily average or average over the sampling period) Nitrogen oxides (NOX) from catalytic oxidation 5-30 Nitrogen oxides (NOX) from thermal oxidation 5-130 Carbon monoxide (CO) No BAT-AEL The associated monitoring is given in BAT 8. The BAT-AEL for channelled emissions to air of SO2 is given in Table 1.6.
BAT 17. Table 1.5 BAT-associated emission level (BAT-AEL) for channelled emissions to air of ammonia from the use of SCR or SNCR (ammonia slip)
In order to reduce channelled emissions to air of ammonia from the use of selective catalytic reduction (SCR) or selective non-catalytic reduction (SNCR) for the abatement of NOX emissions (ammonia slip), BAT is to optimise the design and/or operation of SCR or SNCR (e.g. optimised reagent to NOX ratio, homogeneous reagent distribution and optimum size of the reagent drops). Substance/Parameter BAT-AEL (mg/Nm3) (Average over the sampling period) Ammonia (NH3) from SCR/SNCR < 0,5-8 The associated monitoring is given in BAT 8.
BAT 18. Table 1.6 BAT-associated emission levels (BAT-AELs) for channelled emissions to air of inorganic compounds
In order to reduce channelled emissions to air of inorganic compounds other than channelled emissions to air of ammonia from the use of selective catalytic reduction (SCR) or selective non-catalytic reduction (SNCR) for the abatement of NOX emissions), channelled emissions to air of CO, NOX and SOX from the use of thermal treatment, and channelled emissions to air of NOX from process furnaces/heaters, BAT is to use one or a combination of the techniques given below. Technique Description Main inorganic compounds targeted Applicability Specific techniques to reduce emissions to air of inorganic compounds a. Absorption See Section 1.4.1. Cl2, HCl, HCN, HF, NH3, NOX, SOX Generally applicable. b. Adsorption See Section 1.4.1. For the removal of inorganic substances, the technique is often used in combination with a dust abatement technique (see BAT 14). HCl, HF, NH3, SOX Generally applicable. c. Selective catalytic reduction (SCR) See Section 1.4.1. NOX Applicability to existing plants may be restricted by space availability. d. Selective non-catalytic reduction (SNCR) See Section 1.4.1. NOX Applicability to existing plants may be restricted by the residence time needed for the reaction. Other techniques not primarily used to reduce emissions to air of inorganic compounds e. Catalytic oxidation See Section 1.4.1. NH3 Applicability may be restricted by the presence of catalyst poisons in the waste gases. f. Thermal oxidation See Section 1.4.1. NH3, HCN Applicability of recuperative and regenerative thermal oxidation to existing plants may be restricted by design and/or operational constraints. The applicability may be restricted where the energy demand is excessive due to the low concentration of the compound(s) concerned in the process off-gases. Substance/Parameter BAT-AEL (mg/Nm3) (Daily average or average over the sampling period) Ammonia (NH3) 2-10 Elemental chlorine (Cl2) < 0,5-2 Gaseous fluorides, expressed as HF ≤ 1 Hydrogen cyanide (HCN) < 0,1-1 Gaseous chlorides, expressed as HCl 1-10 Nitrogen oxides (NOX) 10-150 Sulphur oxides (SO2) < 3-150 The associated monitoring is given in BAT 8.
1.1.4. Diffuse VOC emissions to air (i) Estimating the annual quantity of diffuse VOC emissions (see BAT 20). (ii) Monitoring diffuse VOC emissions from the use of solvents by compiling a solvent mass balance, if applicable (see BAT 21). (a) Listing of equipment identified as relevant fugitive VOC emission sources in the inventory of diffuse VOC emissions (see BAT 2). (1) Leaky equipment. Typical criteria could be a leak threshold, above which equipment is considered leaky, and/or the visualisation of a leak with OGI cameras. This depends on the characteristics of the emission source (e.g. accessibility) and the hazardous properties of the emitted substance(s). (2) Maintenance and/or repair actions to be carried out. A typical criterion could be a VOC concentration threshold triggering the maintenance or repair action (maintenance/repair threshold). The maintenance/repair threshold is generally equal to or higher than the leak threshold. This depends on the characteristics of the emission source (e.g. accessibility) and the hazardous properties of the emitted substance(s). For the first LDAR programme, it is generally not higher than 5000 ppmv for VOCs other than VOCs classified as CMR 1A or 1B, and 1000 ppmv for VOCs classified as CMR 1A or 1B. For subsequent LDAR programmes, the maintenance/repair threshold is lowered (see point vi. a.) and not higher than 1000 ppmv for VOCs other than VOCs classified as CMR 1A or 1B, and 500 ppmv for VOCs classified as CMR 1A or 1B, targeting 100 ppmv. (b) Definition of criteria associated with the following: (c) Measuring fugitive VOC emissions from equipment listed under point iii. a. (see BAT 22). (d) Carrying out maintenance and/or repair actions (see BAT 23, techniques e. and f.), as soon as possible and where necessary according to the criteria defined in point iii. b. Maintenance and repair actions are prioritised according to the hazardous properties of the emitted substance(s), the significance of the emissions and/or operational constraints. The effectiveness of the maintenance and/or repair actions is verified according to point iii. c., leaving enough time after the intervention (e.g. 2 months). (e) Filling in the database mentioned in point v. (iii) Establishing and implementing a leak detection and repair (LDAR) programme for fugitive VOC emissions. The LDAR programme typically lasts from 1 to 5 years depending on the nature, scale and complexity of the plant (5 years may correspond to large plants with a high number of emission sources). The LDAR programme includes all of the following features: (a) Listing of equipment identified as relevant non-fugitive VOC emission sources in the inventory of diffuse VOC emissions (see BAT 2). (b) Monitoring non-fugitive VOC emissions from equipment listed under point iv. a. (see BAT 22). (c) Planning and implementing techniques to reduce non-fugitive VOC emissions (see BAT 23, techniques a., c. and g. to j.). The planning and implementation of the techniques are prioritised according to the hazardous properties of the emitted substance(s), the significance of the emissions and/or operational constraints. (d) Filling in the database mentioned in point v. (iv) Establishing and implementing a detection and reduction programme for non-fugitive VOC emissions that includes all of the following features: (a) equipment design specifications (including the date and description of any design changes); (b) the equipment maintenance, repair, upgrade, or replacement actions, performed or planned, and their date of implementation; (c) the equipment that could not be maintained, repaired, upgraded or replaced due to operational constraints; (d) the results of the measurements or monitoring, including the concentration(s) of the emitted substance(s), the calculated leak rate (as kg/year), the recording from OGI cameras (e.g. from the last LDAR programme) and the date of the measurements or monitoring; (e) the annual quantity of diffuse VOC emissions (as fugitive and non-fugitive emissions), including information on non-accessible sources and accessible sources not monitored during the year. (v) Establishing and maintaining a database, for diffuse VOC emissions sources that are identified in the inventory mentioned in BAT 2, for keeping record of: (a) lowering the leak and/or maintenance/repair thresholds (see point iii. b.); (b) reviewing the prioritisation of equipment to be monitored, giving higher priority to (the type of) equipment identified as leaky during the previous LDAR programme; (c) planning the maintenance, repair, upgrade or replacement of equipment that could not be performed during the previous LDAR programme due to operational constraints. (vi) Reviewing and updating the LDAR programme periodically. This may include the following: (a) monitoring non-fugitive VOC emissions from equipment where maintenance, repair, upgrade or replacement actions were implemented, in order to determine if those actions were successful; (b) planning the maintenance, repair, upgrade or replacement actions that could not be performed due to operational constraints. (vii) Reviewing and updating the detection and reduction programme for non-fugitive VOC emissions. This may include the following: Grp. applicability. The features points iii., iv., vi., and vii. are only applicable to sources of diffuse VOC emissions for which monitoring according to BAT 22 is applicable. The level of detail of the management system for diffuse VOC emissions will be proportionate to the nature, scale and complexity of the plant, and the range of environmental impacts it may have. Grp. 19. In order to prevent or, where that is not practicable, to reduce diffuse VOC emissions to air, BAT is to elaborate and implement a management system for diffuse VOC emissions, as part of the environmental management system (see BAT 1), that includes all of the following features: Grp. 1141. Management system for diffuse VOC emissions (1) chemical properties of the substance (e.g. vapour pressure, molecular mass); (2) process operating data (e.g. operating time, product quantity, ventilation); (3) characteristics of the emission source (e.g. tank diameter, colour, shape). Grp. note. The estimation of the diffuse VOC emissions to air takes into account the results of the monitoring carried out according to BAT 21 and/or to BAT 22. For the purpose of the estimation, channelled emissions may be counted as non-fugitive emissions when the inherent characteristics of the waste gas stream (e.g. low velocities, variability of the flow rate and concentration) do not allow an accurate measurement according to BAT 8. The main sources of uncertainty of the estimation are identified, and corrective actions are implemented to reduce the uncertainty. Technique Description Type of emissions a. Use of emission factors See Section 1.4.2. Fugitive and/or non-fugitive b. Use of a mass balance Estimation based on the difference in the mass of the substance inputs to and outputs from the plant/production unit, taking into account the generation and destruction of the substance in the plant/production unit. A mass balance may also consist of measuring the concentration of VOCs in the product (e.g. raw material or solvent). c. Use of thermodynamic models Estimation using the laws of thermodynamics applied to equipment (e.g. tanks) or particular steps of a production process. The following data are generally used as input for the model: Grp. 20. BAT is to estimate fugitive and non-fugitive VOC emissions to air separately at least once every year by using one or a combination of the techniques given below, as well as to determine the uncertainty of this estimation. The estimation distinguishes between VOCs classified as CMR 1A or 1B and VOCs that are not classified as CMR 1A or 1B. (1) identification and documentation of solvent inputs and outputs (e.g. channelled and diffuse emissions to air, emissions to water, solvent output in waste); (2) substantiated quantification of each relevant solvent input and output and recording of the methodology used (e.g. measurement, estimation by using emission factors, estimation based on operational parameters); (3) identification of the main sources of uncertainty of the aforementioned quantification, and implementation of corrective actions to reduce the uncertainty; (4) regular update of solvent input and output data. (5) malfunctions of the waste gas treatment system: the date and period of time are recorded; (6) changes that may influence air/gas flow rates (e.g. replacement of fans): the date and type of change are recorded. Grp. applicability. This BAT may not apply to the production of polyolefins, PVC or synthetic rubbers. This BAT may not be applicable to plants whose total annual consumption of solvents is lower than 50 tonnes. The level of detail of the solvent mass balance will be proportionate to the nature, scale and complexity of the plant, and the range of environmental impacts it may have, as well as to the type and quantity of solvents used. Grp. 21. BAT is to monitor diffuse VOC emissions from the use of solvents by compiling, at least once every year, a solvent mass balance of the solvent inputs and outputs of the plant, as defined in Part 7 of Annex VII to Directive 2010/75/EU and to minimise the uncertainty of the solvent mass balance data by using all of the techniques given below. Technique Description a. Full identification and quantification of the relevant solvent inputs and outputs, including the associated uncertainty This includes: b. Implementation of a solvent tracking system A solvent tracking system aims to keep control of both the used and unused quantities of solvents (e.g. by weighing unused quantities returned to storage from the application area). c. Monitoring of changes that may influence the uncertainty of the solvent mass balance data Any change that could influence the uncertainty of the solvent mass balance data is recorded, such as: Grp. note. Optical gas imaging (OGI) is a useful complementary technique to the method EN 15446 (sniffing) in order to identify sources of fugitive VOC emissions and is particularly relevant in the case of inaccessible sources (see Section 1.4.2.). This technique is described in EN 17628. In the case of non-fugitive emissions, measurements may be complemented by the use of thermodynamic models. Where large amounts (e.g. above 80 t/yr) of VOCs are used/consumed, the quantification of VOC emissions from the plant with tracer correlation (TC) or with optical absorption-based techniques, such as differential absorption light detection and ranging (DIAL) or solar occultation flux (SOF), is a useful complementary technique (see Section 1.4.2.). These techniques are described in EN 17628. (1) 1 tonne of VOCs per year in the case of VOCs classified as CMR 1A or 1B; or (2) 5 tonnes of VOCs per year in the case of other VOCs. (3) 1 tonne of VOCs per year in the case of VOCs classified as CMR 1A or 1B; or (4) 5 tonnes of VOCs per year in the case of other VOCs. Grp. applicability. BAT 22 only applies when the annual quantity of diffuse VOC emissions from the plant estimated according to BAT 20 is greater than the following: For fugitive emissions: For non-fugitive emissions: Grp. 22. BAT is to monitor diffuse VOC emissions to air with at least the frequency given below and in accordance with EN standards. If EN standards are not available, BAT is to use ISO, national or other international standards that ensure the provision of data of an equivalent scientific quality. Type of sources of diffuse VOC emissions Type of VOCs Standard(s) Minimum monitoring frequency Sources of fugitive emissions VOCs classified as CMR 1A or 1B EN 15446 Once every year VOCs not classified as CMR 1A or 1B Once during the period covered by each LDAR programme (see BAT 19 point iii.) Sources of non-fugitive emissions VOCs classified as CMR 1A or 1B EN 17628 Once every year VOCs not classified as CMR 1A or 1B Once every year Grp. 1142. Monitoring (1) minimising pipe lengths; (2) reducing the number of pipe connectors (e.g. flanges) and valves; (3) using welded fittings and connections; (4) using compressed air or gravity for material transfer. (5) bellow valves or double packing seals or equally effective equipment; (6) magnetically driven or canned pumps/compressors/agitators, or pumps/compressors/agitators using double seals and a liquid barrier; (7) certified high-quality gaskets (e.g. according to EN 13555) that are tightened according to technique e.; (8) closed sampling system. (9) emissions of CMR substances or substances with acute toxicity; and/or (10) emissions from equipment with high-leaking potential; and/or (11) leaks from processes operated at high pressures (e.g. between 300 bar and 2000 bar). (12) for existing plants; and/or (13) by safety concerns (e.g. avoiding concentrations close to the lower explosive limit). (14) tightening of gaskets by personnel that is qualified according to EN 1591-4 and using the designed gasket stress (e.g. calculated according to EN 1591-1); (15) installing tight caps on open ends; (16) using flanges selected and assembled according to EN 13555. (17) gaskets; (18) sealing elements (e.g. tank lid); (19) packing material (e.g. valve stem packing material). (20) reducing the use of solvents and/or using solvents with lower volatility; (21) reducing the formation of side products containing VOCs; (22) lowering the operating temperature; (23) lowering the VOC content in the final product. (24) reducing the frequency and duration of reactor and vessel openings; (25) preventing corrosion by lining or coating of equipment, by painting pipes (for external corrosion) and by using corrosion inhibitors for materials in contact with equipment. (26) vapour balancing (see Section 1.4.3); (27) closed systems for solid/liquid and liquid/liquid phase separations; (28) closed systems for cleaning operations; (29) closed sewers and/or waste water treatment plants; (30) closed sampling systems; (31) closed storage areas. (32) installing oil creaming systems on open surfaces; (33) periodically skimming open surfaces (e.g. removing floating matter); (34) installing anti-evaporation floating elements on open surfaces; (35) treating waste water streams to remove VOCs and send the VOCs to recovery (see BAT 9 and BAT 10) and/or abatement (see BAT 11); (36) installing floating roofs on tanks; (37) using fixed-roof tanks connected to a waste gas treatment. Grp. 1. The use of techniques to prevent or, where that is not practicable, to reduce diffuse VOC emissions to air is prioritised according to the hazardous properties of the emitted substance(s) and/or the significance of the emissions. Technique Description Type of emissions Applicability Prevention techniques a. Limiting the number of emission sources This includes: Fugitive and non-fugitive emissions Applicability may be restricted by operational constraints in the case of existing plants. b. Use of high-integrity equipment High-integrity equipment includes, but is not limited to: The use of high-integrity equipment is especially relevant to prevent or minimise: High-integrity equipment is selected, installed and maintained according to the type of process and the process operating conditions. Fugitive emissions Applicability may be restricted by operational constraints in the case of existing plants. Generally applicable to new plants and major plant upgrades. c. Collecting diffuse emissions and treating off-gases Collecting diffuse VOC emissions (e.g. from compressor seals, vents and purge lines) and sending them to recovery (see BAT 9 and BAT 10) and/or abatement (see BAT 11). Fugitive and non-fugitive emissions Applicability may be restricted: Other techniques d. Facilitating access and/or monitoring activities To ease maintenance and/or monitoring activities, the access to potentially leaky equipment is facilitated, e.g. by installing platforms, and/or drones are used for monitoring. Fugitive emissions Applicability may be restricted by operational constraints in the case of existing plants. e. Tightening This includes: Fugitive emissions Generally applicable. f. Replacement of leaky equipment and/or parts This includes the replacement of: Fugitive emissions Generally applicable. g. Reviewing and updating process design This includes: Non-fugitive emissions Applicability may be restricted in the case of existing plants due to operational constraints. h. Reviewing and updating operating conditions This includes: Non-fugitive emissions Generally applicable. i. Using closed systems This includes: Off-gases from closed systems are sent to recovery (see BAT 9 and BAT 10) and/or abatement (see BAT 11). Non-fugitive emissions Applicability may be restricted by operational constraints in the case of existing plants and/or by safety concerns. j. Using techniques to minimise emissions from surfaces This includes: Non-fugitive emissions Applicability may be restricted by operational constraints in the case of existing plants. Grp. 23. In order to prevent or, where that is not practicable, to reduce diffuse VOC emissions to air, BAT is to use a combination of the techniques given below with the following order of priority. Grp. 1143. Prevention or reduction of diffuse VOC emissions Grp_1144_table. 17. BAT conclusions for the use of solvents or the reuse of recovered solvents The emission levels for the use of solvents or the reuse of recovered solvents given below are associated with the general BAT conclusions given in Section 1.1 and Section 1.1.4.3. Parameter BAT-AEL (percentage of the solvent inputs) (yearly average) Diffuse VOC emissions ≤ 5 % The associated monitoring is given in BAT 20, BAT 21 and BAT 22.
1.1.4.
1.1.4.1. Management system for diffuse VOC emissions (i) Estimating the annual quantity of diffuse VOC emissions (see BAT 20). (ii) Monitoring diffuse VOC emissions from the use of solvents by compiling a solvent mass balance, if applicable (see BAT 21). (a) Listing of equipment identified as relevant fugitive VOC emission sources in the inventory of diffuse VOC emissions (see BAT 2). (1) Leaky equipment. Typical criteria could be a leak threshold, above which equipment is considered leaky, and/or the visualisation of a leak with OGI cameras. This depends on the characteristics of the emission source (e.g. accessibility) and the hazardous properties of the emitted substance(s). (2) Maintenance and/or repair actions to be carried out. A typical criterion could be a VOC concentration threshold triggering the maintenance or repair action (maintenance/repair threshold). The maintenance/repair threshold is generally equal to or higher than the leak threshold. This depends on the characteristics of the emission source (e.g. accessibility) and the hazardous properties of the emitted substance(s). For the first LDAR programme, it is generally not higher than 5000 ppmv for VOCs other than VOCs classified as CMR 1A or 1B, and 1000 ppmv for VOCs classified as CMR 1A or 1B. For subsequent LDAR programmes, the maintenance/repair threshold is lowered (see point vi. a.) and not higher than 1000 ppmv for VOCs other than VOCs classified as CMR 1A or 1B, and 500 ppmv for VOCs classified as CMR 1A or 1B, targeting 100 ppmv. (b) Definition of criteria associated with the following: (c) Measuring fugitive VOC emissions from equipment listed under point iii. a. (see BAT 22). (d) Carrying out maintenance and/or repair actions (see BAT 23, techniques e. and f.), as soon as possible and where necessary according to the criteria defined in point iii. b. Maintenance and repair actions are prioritised according to the hazardous properties of the emitted substance(s), the significance of the emissions and/or operational constraints. The effectiveness of the maintenance and/or repair actions is verified according to point iii. c., leaving enough time after the intervention (e.g. 2 months). (e) Filling in the database mentioned in point v. (iii) Establishing and implementing a leak detection and repair (LDAR) programme for fugitive VOC emissions. The LDAR programme typically lasts from 1 to 5 years depending on the nature, scale and complexity of the plant (5 years may correspond to large plants with a high number of emission sources). The LDAR programme includes all of the following features: (a) Listing of equipment identified as relevant non-fugitive VOC emission sources in the inventory of diffuse VOC emissions (see BAT 2). (b) Monitoring non-fugitive VOC emissions from equipment listed under point iv. a. (see BAT 22). (c) Planning and implementing techniques to reduce non-fugitive VOC emissions (see BAT 23, techniques a., c. and g. to j.). The planning and implementation of the techniques are prioritised according to the hazardous properties of the emitted substance(s), the significance of the emissions and/or operational constraints. (d) Filling in the database mentioned in point v. (iv) Establishing and implementing a detection and reduction programme for non-fugitive VOC emissions that includes all of the following features: (a) equipment design specifications (including the date and description of any design changes); (b) the equipment maintenance, repair, upgrade, or replacement actions, performed or planned, and their date of implementation; (c) the equipment that could not be maintained, repaired, upgraded or replaced due to operational constraints; (d) the results of the measurements or monitoring, including the concentration(s) of the emitted substance(s), the calculated leak rate (as kg/year), the recording from OGI cameras (e.g. from the last LDAR programme) and the date of the measurements or monitoring; (e) the annual quantity of diffuse VOC emissions (as fugitive and non-fugitive emissions), including information on non-accessible sources and accessible sources not monitored during the year. (v) Establishing and maintaining a database, for diffuse VOC emissions sources that are identified in the inventory mentioned in BAT 2, for keeping record of: (a) lowering the leak and/or maintenance/repair thresholds (see point iii. b.); (b) reviewing the prioritisation of equipment to be monitored, giving higher priority to (the type of) equipment identified as leaky during the previous LDAR programme; (c) planning the maintenance, repair, upgrade or replacement of equipment that could not be performed during the previous LDAR programme due to operational constraints. (vi) Reviewing and updating the LDAR programme periodically. This may include the following: (a) monitoring non-fugitive VOC emissions from equipment where maintenance, repair, upgrade or replacement actions were implemented, in order to determine if those actions were successful; (b) planning the maintenance, repair, upgrade or replacement actions that could not be performed due to operational constraints. (vii) Reviewing and updating the detection and reduction programme for non-fugitive VOC emissions. This may include the following: Grp. applicability. The features points iii., iv., vi., and vii. are only applicable to sources of diffuse VOC emissions for which monitoring according to BAT 22 is applicable. The level of detail of the management system for diffuse VOC emissions will be proportionate to the nature, scale and complexity of the plant, and the range of environmental impacts it may have. Grp. 19. In order to prevent or, where that is not practicable, to reduce diffuse VOC emissions to air, BAT is to elaborate and implement a management system for diffuse VOC emissions, as part of the environmental management system (see BAT 1), that includes all of the following features:
1.1.4.1.
BAT 19. In order to prevent or, where that is not practicable, to reduce diffuse VOC emissions to air, BAT is to elaborate and implement a management system for diffuse VOC emissions, as part of the environmental management system (see BAT 1), that includes all of the following features: (i) Estimating the annual quantity of diffuse VOC emissions (see BAT 20). (ii) Monitoring diffuse VOC emissions from the use of solvents by compiling a solvent mass balance, if applicable (see BAT 21). (a) Listing of equipment identified as relevant fugitive VOC emission sources in the inventory of diffuse VOC emissions (see BAT 2). (1) Leaky equipment. Typical criteria could be a leak threshold, above which equipment is considered leaky, and/or the visualisation of a leak with OGI cameras. This depends on the characteristics of the emission source (e.g. accessibility) and the hazardous properties of the emitted substance(s). (2) Maintenance and/or repair actions to be carried out. A typical criterion could be a VOC concentration threshold triggering the maintenance or repair action (maintenance/repair threshold). The maintenance/repair threshold is generally equal to or higher than the leak threshold. This depends on the characteristics of the emission source (e.g. accessibility) and the hazardous properties of the emitted substance(s). For the first LDAR programme, it is generally not higher than 5000 ppmv for VOCs other than VOCs classified as CMR 1A or 1B, and 1000 ppmv for VOCs classified as CMR 1A or 1B. For subsequent LDAR programmes, the maintenance/repair threshold is lowered (see point vi. a.) and not higher than 1000 ppmv for VOCs other than VOCs classified as CMR 1A or 1B, and 500 ppmv for VOCs classified as CMR 1A or 1B, targeting 100 ppmv. (b) Definition of criteria associated with the following: (c) Measuring fugitive VOC emissions from equipment listed under point iii. a. (see BAT 22). (d) Carrying out maintenance and/or repair actions (see BAT 23, techniques e. and f.), as soon as possible and where necessary according to the criteria defined in point iii. b. Maintenance and repair actions are prioritised according to the hazardous properties of the emitted substance(s), the significance of the emissions and/or operational constraints. The effectiveness of the maintenance and/or repair actions is verified according to point iii. c., leaving enough time after the intervention (e.g. 2 months). (e) Filling in the database mentioned in point v. (iii) Establishing and implementing a leak detection and repair (LDAR) programme for fugitive VOC emissions. The LDAR programme typically lasts from 1 to 5 years depending on the nature, scale and complexity of the plant (5 years may correspond to large plants with a high number of emission sources). The LDAR programme includes all of the following features: (a) Listing of equipment identified as relevant non-fugitive VOC emission sources in the inventory of diffuse VOC emissions (see BAT 2). (b) Monitoring non-fugitive VOC emissions from equipment listed under point iv. a. (see BAT 22). (c) Planning and implementing techniques to reduce non-fugitive VOC emissions (see BAT 23, techniques a., c. and g. to j.). The planning and implementation of the techniques are prioritised according to the hazardous properties of the emitted substance(s), the significance of the emissions and/or operational constraints. (d) Filling in the database mentioned in point v. (iv) Establishing and implementing a detection and reduction programme for non-fugitive VOC emissions that includes all of the following features: (a) equipment design specifications (including the date and description of any design changes); (b) the equipment maintenance, repair, upgrade, or replacement actions, performed or planned, and their date of implementation; (c) the equipment that could not be maintained, repaired, upgraded or replaced due to operational constraints; (d) the results of the measurements or monitoring, including the concentration(s) of the emitted substance(s), the calculated leak rate (as kg/year), the recording from OGI cameras (e.g. from the last LDAR programme) and the date of the measurements or monitoring; (e) the annual quantity of diffuse VOC emissions (as fugitive and non-fugitive emissions), including information on non-accessible sources and accessible sources not monitored during the year. (v) Establishing and maintaining a database, for diffuse VOC emissions sources that are identified in the inventory mentioned in BAT 2, for keeping record of: (a) lowering the leak and/or maintenance/repair thresholds (see point iii. b.); (b) reviewing the prioritisation of equipment to be monitored, giving higher priority to (the type of) equipment identified as leaky during the previous LDAR programme; (c) planning the maintenance, repair, upgrade or replacement of equipment that could not be performed during the previous LDAR programme due to operational constraints. (vi) Reviewing and updating the LDAR programme periodically. This may include the following: (a) monitoring non-fugitive VOC emissions from equipment where maintenance, repair, upgrade or replacement actions were implemented, in order to determine if those actions were successful; (b) planning the maintenance, repair, upgrade or replacement actions that could not be performed due to operational constraints. (vii) Reviewing and updating the detection and reduction programme for non-fugitive VOC emissions. This may include the following: Grp. applicability. The features points iii., iv., vi., and vii. are only applicable to sources of diffuse VOC emissions for which monitoring according to BAT 22 is applicable. The level of detail of the management system for diffuse VOC emissions will be proportionate to the nature, scale and complexity of the plant, and the range of environmental impacts it may have.
BAT 19. i.
Estimating the annual quantity of diffuse VOC emissions (see BAT 20).
ii.
Monitoring diffuse VOC emissions from the use of solvents by compiling a solvent mass balance, if applicable (see BAT 21).
iii.
Establishing and implementing a leak detection and repair (LDAR) programme for fugitive VOC emissions. The LDAR programme typically lasts from 1 to 5 years depending on the nature, scale and complexity of the plant (5 years may correspond to large plants with a high number of emission sources). The LDAR programme includes all of the following features: (a) Listing of equipment identified as relevant fugitive VOC emission sources in the inventory of diffuse VOC emissions (see BAT 2). (1) Leaky equipment. Typical criteria could be a leak threshold, above which equipment is considered leaky, and/or the visualisation of a leak with OGI cameras. This depends on the characteristics of the emission source (e.g. accessibility) and the hazardous properties of the emitted substance(s). (2) Maintenance and/or repair actions to be carried out. A typical criterion could be a VOC concentration threshold triggering the maintenance or repair action (maintenance/repair threshold). The maintenance/repair threshold is generally equal to or higher than the leak threshold. This depends on the characteristics of the emission source (e.g. accessibility) and the hazardous properties of the emitted substance(s). For the first LDAR programme, it is generally not higher than 5000 ppmv for VOCs other than VOCs classified as CMR 1A or 1B, and 1000 ppmv for VOCs classified as CMR 1A or 1B. For subsequent LDAR programmes, the maintenance/repair threshold is lowered (see point vi. a.) and not higher than 1000 ppmv for VOCs other than VOCs classified as CMR 1A or 1B, and 500 ppmv for VOCs classified as CMR 1A or 1B, targeting 100 ppmv. (b) Definition of criteria associated with the following: (c) Measuring fugitive VOC emissions from equipment listed under point iii. a. (see BAT 22). (d) Carrying out maintenance and/or repair actions (see BAT 23, techniques e. and f.), as soon as possible and where necessary according to the criteria defined in point iii. b. Maintenance and repair actions are prioritised according to the hazardous properties of the emitted substance(s), the significance of the emissions and/or operational constraints. The effectiveness of the maintenance and/or repair actions is verified according to point iii. c., leaving enough time after the intervention (e.g. 2 months). (e) Filling in the database mentioned in point v.
a.
Listing of equipment identified as relevant fugitive VOC emission sources in the inventory of diffuse VOC emissions (see BAT 2).
b.
Definition of criteria associated with the following: (1) Leaky equipment. Typical criteria could be a leak threshold, above which equipment is considered leaky, and/or the visualisation of a leak with OGI cameras. This depends on the characteristics of the emission source (e.g. accessibility) and the hazardous properties of the emitted substance(s). (2) Maintenance and/or repair actions to be carried out. A typical criterion could be a VOC concentration threshold triggering the maintenance or repair action (maintenance/repair threshold). The maintenance/repair threshold is generally equal to or higher than the leak threshold. This depends on the characteristics of the emission source (e.g. accessibility) and the hazardous properties of the emitted substance(s). For the first LDAR programme, it is generally not higher than 5000 ppmv for VOCs other than VOCs classified as CMR 1A or 1B, and 1000 ppmv for VOCs classified as CMR 1A or 1B. For subsequent LDAR programmes, the maintenance/repair threshold is lowered (see point vi. a.) and not higher than 1000 ppmv for VOCs other than VOCs classified as CMR 1A or 1B, and 500 ppmv for VOCs classified as CMR 1A or 1B, targeting 100 ppmv.
Leaky equipment. Typical criteria could be a leak threshold, above which equipment is considered leaky, and/or the visualisation of a leak with OGI cameras. This depends on the characteristics of the emission source (e.g. accessibility) and the hazardous properties of the emitted substance(s).
Maintenance and/or repair actions to be carried out. A typical criterion could be a VOC concentration threshold triggering the maintenance or repair action (maintenance/repair threshold). The maintenance/repair threshold is generally equal to or higher than the leak threshold. This depends on the characteristics of the emission source (e.g. accessibility) and the hazardous properties of the emitted substance(s). For the first LDAR programme, it is generally not higher than 5000 ppmv for VOCs other than VOCs classified as CMR 1A or 1B, and 1000 ppmv for VOCs classified as CMR 1A or 1B. For subsequent LDAR programmes, the maintenance/repair threshold is lowered (see point vi. a.) and not higher than 1000 ppmv for VOCs other than VOCs classified as CMR 1A or 1B, and 500 ppmv for VOCs classified as CMR 1A or 1B, targeting 100 ppmv.
c.
Measuring fugitive VOC emissions from equipment listed under point iii. a. (see BAT 22).
d.
Carrying out maintenance and/or repair actions (see BAT 23, techniques e. and f.), as soon as possible and where necessary according to the criteria defined in point iii. b. Maintenance and repair actions are prioritised according to the hazardous properties of the emitted substance(s), the significance of the emissions and/or operational constraints. The effectiveness of the maintenance and/or repair actions is verified according to point iii. c., leaving enough time after the intervention (e.g. 2 months).
e.
Filling in the database mentioned in point v.
iv.
Establishing and implementing a detection and reduction programme for non-fugitive VOC emissions that includes all of the following features: (a) Listing of equipment identified as relevant non-fugitive VOC emission sources in the inventory of diffuse VOC emissions (see BAT 2). (b) Monitoring non-fugitive VOC emissions from equipment listed under point iv. a. (see BAT 22). (c) Planning and implementing techniques to reduce non-fugitive VOC emissions (see BAT 23, techniques a., c. and g. to j.). The planning and implementation of the techniques are prioritised according to the hazardous properties of the emitted substance(s), the significance of the emissions and/or operational constraints. (d) Filling in the database mentioned in point v.
a.
Listing of equipment identified as relevant non-fugitive VOC emission sources in the inventory of diffuse VOC emissions (see BAT 2).
b.
Monitoring non-fugitive VOC emissions from equipment listed under point iv. a. (see BAT 22).
c.
Planning and implementing techniques to reduce non-fugitive VOC emissions (see BAT 23, techniques a., c. and g. to j.). The planning and implementation of the techniques are prioritised according to the hazardous properties of the emitted substance(s), the significance of the emissions and/or operational constraints.
d.
Filling in the database mentioned in point v.
v.
Establishing and maintaining a database, for diffuse VOC emissions sources that are identified in the inventory mentioned in BAT 2, for keeping record of: (a) equipment design specifications (including the date and description of any design changes); (b) the equipment maintenance, repair, upgrade, or replacement actions, performed or planned, and their date of implementation; (c) the equipment that could not be maintained, repaired, upgraded or replaced due to operational constraints; (d) the results of the measurements or monitoring, including the concentration(s) of the emitted substance(s), the calculated leak rate (as kg/year), the recording from OGI cameras (e.g. from the last LDAR programme) and the date of the measurements or monitoring; (e) the annual quantity of diffuse VOC emissions (as fugitive and non-fugitive emissions), including information on non-accessible sources and accessible sources not monitored during the year.
a.
equipment design specifications (including the date and description of any design changes);
b.
the equipment maintenance, repair, upgrade, or replacement actions, performed or planned, and their date of implementation;
c.
the equipment that could not be maintained, repaired, upgraded or replaced due to operational constraints;
d.
the results of the measurements or monitoring, including the concentration(s) of the emitted substance(s), the calculated leak rate (as kg/year), the recording from OGI cameras (e.g. from the last LDAR programme) and the date of the measurements or monitoring;
e.
the annual quantity of diffuse VOC emissions (as fugitive and non-fugitive emissions), including information on non-accessible sources and accessible sources not monitored during the year.
vi.
Reviewing and updating the LDAR programme periodically. This may include the following: (a) lowering the leak and/or maintenance/repair thresholds (see point iii. b.); (b) reviewing the prioritisation of equipment to be monitored, giving higher priority to (the type of) equipment identified as leaky during the previous LDAR programme; (c) planning the maintenance, repair, upgrade or replacement of equipment that could not be performed during the previous LDAR programme due to operational constraints.
a.
lowering the leak and/or maintenance/repair thresholds (see point iii. b.);
b.
reviewing the prioritisation of equipment to be monitored, giving higher priority to (the type of) equipment identified as leaky during the previous LDAR programme;
c.
planning the maintenance, repair, upgrade or replacement of equipment that could not be performed during the previous LDAR programme due to operational constraints.
vii.
Reviewing and updating the detection and reduction programme for non-fugitive VOC emissions. This may include the following: (a) monitoring non-fugitive VOC emissions from equipment where maintenance, repair, upgrade or replacement actions were implemented, in order to determine if those actions were successful; (b) planning the maintenance, repair, upgrade or replacement actions that could not be performed due to operational constraints.
a.
monitoring non-fugitive VOC emissions from equipment where maintenance, repair, upgrade or replacement actions were implemented, in order to determine if those actions were successful;
b.
planning the maintenance, repair, upgrade or replacement actions that could not be performed due to operational constraints.
Applicability
The features points iii., iv., vi., and vii. are only applicable to sources of diffuse VOC emissions for which monitoring according to BAT 22 is applicable. The level of detail of the management system for diffuse VOC emissions will be proportionate to the nature, scale and complexity of the plant, and the range of environmental impacts it may have.
1.1.4.2. Monitoring (1) chemical properties of the substance (e.g. vapour pressure, molecular mass); (2) process operating data (e.g. operating time, product quantity, ventilation); (3) characteristics of the emission source (e.g. tank diameter, colour, shape). Grp. note. The estimation of the diffuse VOC emissions to air takes into account the results of the monitoring carried out according to BAT 21 and/or to BAT 22. For the purpose of the estimation, channelled emissions may be counted as non-fugitive emissions when the inherent characteristics of the waste gas stream (e.g. low velocities, variability of the flow rate and concentration) do not allow an accurate measurement according to BAT 8. The main sources of uncertainty of the estimation are identified, and corrective actions are implemented to reduce the uncertainty. Technique Description Type of emissions a. Use of emission factors See Section 1.4.2. Fugitive and/or non-fugitive b. Use of a mass balance Estimation based on the difference in the mass of the substance inputs to and outputs from the plant/production unit, taking into account the generation and destruction of the substance in the plant/production unit. A mass balance may also consist of measuring the concentration of VOCs in the product (e.g. raw material or solvent). c. Use of thermodynamic models Estimation using the laws of thermodynamics applied to equipment (e.g. tanks) or particular steps of a production process. The following data are generally used as input for the model: Grp. 20. BAT is to estimate fugitive and non-fugitive VOC emissions to air separately at least once every year by using one or a combination of the techniques given below, as well as to determine the uncertainty of this estimation. The estimation distinguishes between VOCs classified as CMR 1A or 1B and VOCs that are not classified as CMR 1A or 1B. (1) identification and documentation of solvent inputs and outputs (e.g. channelled and diffuse emissions to air, emissions to water, solvent output in waste); (2) substantiated quantification of each relevant solvent input and output and recording of the methodology used (e.g. measurement, estimation by using emission factors, estimation based on operational parameters); (3) identification of the main sources of uncertainty of the aforementioned quantification, and implementation of corrective actions to reduce the uncertainty; (4) regular update of solvent input and output data. (5) malfunctions of the waste gas treatment system: the date and period of time are recorded; (6) changes that may influence air/gas flow rates (e.g. replacement of fans): the date and type of change are recorded. Grp. applicability. This BAT may not apply to the production of polyolefins, PVC or synthetic rubbers. This BAT may not be applicable to plants whose total annual consumption of solvents is lower than 50 tonnes. The level of detail of the solvent mass balance will be proportionate to the nature, scale and complexity of the plant, and the range of environmental impacts it may have, as well as to the type and quantity of solvents used. Grp. 21. BAT is to monitor diffuse VOC emissions from the use of solvents by compiling, at least once every year, a solvent mass balance of the solvent inputs and outputs of the plant, as defined in Part 7 of Annex VII to Directive 2010/75/EU and to minimise the uncertainty of the solvent mass balance data by using all of the techniques given below. Technique Description a. Full identification and quantification of the relevant solvent inputs and outputs, including the associated uncertainty This includes: b. Implementation of a solvent tracking system A solvent tracking system aims to keep control of both the used and unused quantities of solvents (e.g. by weighing unused quantities returned to storage from the application area). c. Monitoring of changes that may influence the uncertainty of the solvent mass balance data Any change that could influence the uncertainty of the solvent mass balance data is recorded, such as: Grp. note. Optical gas imaging (OGI) is a useful complementary technique to the method EN 15446 (sniffing) in order to identify sources of fugitive VOC emissions and is particularly relevant in the case of inaccessible sources (see Section 1.4.2.). This technique is described in EN 17628. In the case of non-fugitive emissions, measurements may be complemented by the use of thermodynamic models. Where large amounts (e.g. above 80 t/yr) of VOCs are used/consumed, the quantification of VOC emissions from the plant with tracer correlation (TC) or with optical absorption-based techniques, such as differential absorption light detection and ranging (DIAL) or solar occultation flux (SOF), is a useful complementary technique (see Section 1.4.2.). These techniques are described in EN 17628. (1) 1 tonne of VOCs per year in the case of VOCs classified as CMR 1A or 1B; or (2) 5 tonnes of VOCs per year in the case of other VOCs. (3) 1 tonne of VOCs per year in the case of VOCs classified as CMR 1A or 1B; or (4) 5 tonnes of VOCs per year in the case of other VOCs. Grp. applicability. BAT 22 only applies when the annual quantity of diffuse VOC emissions from the plant estimated according to BAT 20 is greater than the following: For fugitive emissions: For non-fugitive emissions: Grp. 22. BAT is to monitor diffuse VOC emissions to air with at least the frequency given below and in accordance with EN standards. If EN standards are not available, BAT is to use ISO, national or other international standards that ensure the provision of data of an equivalent scientific quality. Type of sources of diffuse VOC emissions Type of VOCs Standard(s) Minimum monitoring frequency Sources of fugitive emissions VOCs classified as CMR 1A or 1B EN 15446 Once every year VOCs not classified as CMR 1A or 1B Once during the period covered by each LDAR programme (see BAT 19 point iii.) Sources of non-fugitive emissions VOCs classified as CMR 1A or 1B EN 17628 Once every year VOCs not classified as CMR 1A or 1B Once every year
1.1.4.2.
BAT 20. BAT is to estimate fugitive and non-fugitive VOC emissions to air separately at least once every year by using one or a combination of the techniques given below, as well as to determine the uncertainty of this estimation. The estimation distinguishes between VOCs classified as CMR 1A or 1B and VOCs that are not classified as CMR 1A or 1B. (1) chemical properties of the substance (e.g. vapour pressure, molecular mass); (2) process operating data (e.g. operating time, product quantity, ventilation); (3) characteristics of the emission source (e.g. tank diameter, colour, shape). Grp. note. The estimation of the diffuse VOC emissions to air takes into account the results of the monitoring carried out according to BAT 21 and/or to BAT 22. For the purpose of the estimation, channelled emissions may be counted as non-fugitive emissions when the inherent characteristics of the waste gas stream (e.g. low velocities, variability of the flow rate and concentration) do not allow an accurate measurement according to BAT 8. The main sources of uncertainty of the estimation are identified, and corrective actions are implemented to reduce the uncertainty. Technique Description Type of emissions a. Use of emission factors See Section 1.4.2. Fugitive and/or non-fugitive b. Use of a mass balance Estimation based on the difference in the mass of the substance inputs to and outputs from the plant/production unit, taking into account the generation and destruction of the substance in the plant/production unit. A mass balance may also consist of measuring the concentration of VOCs in the product (e.g. raw material or solvent). c. Use of thermodynamic models Estimation using the laws of thermodynamics applied to equipment (e.g. tanks) or particular steps of a production process. The following data are generally used as input for the model:
BAT 20. Note
The estimation of the diffuse VOC emissions to air takes into account the results of the monitoring carried out according to BAT 21 and/or to BAT 22. For the purpose of the estimation, channelled emissions may be counted as non-fugitive emissions when the inherent characteristics of the waste gas stream (e.g. low velocities, variability of the flow rate and concentration) do not allow an accurate measurement according to BAT 8. The main sources of uncertainty of the estimation are identified, and corrective actions are implemented to reduce the uncertainty. Technique Description Type of emissions a. Use of emission factors See Section 1.4.2. Fugitive and/or non-fugitive b. Use of a mass balance Estimation based on the difference in the mass of the substance inputs to and outputs from the plant/production unit, taking into account the generation and destruction of the substance in the plant/production unit. A mass balance may also consist of measuring the concentration of VOCs in the product (e.g. raw material or solvent). c. Use of thermodynamic models Estimation using the laws of thermodynamics applied to equipment (e.g. tanks) or particular steps of a production process. The following data are generally used as input for the model: (1) chemical properties of the substance (e.g. vapour pressure, molecular mass); (2) process operating data (e.g. operating time, product quantity, ventilation); (3) characteristics of the emission source (e.g. tank diameter, colour, shape).
chemical properties of the substance (e.g. vapour pressure, molecular mass);
process operating data (e.g. operating time, product quantity, ventilation);
characteristics of the emission source (e.g. tank diameter, colour, shape).
BAT 21. BAT is to monitor diffuse VOC emissions from the use of solvents by compiling, at least once every year, a solvent mass balance of the solvent inputs and outputs of the plant, as defined in Part 7 of Annex VII to Directive 2010/75/EU and to minimise the uncertainty of the solvent mass balance data by using all of the techniques given below. Technique Description a. Full identification and quantification of the relevant solvent inputs and outputs, including the associated uncertainty This includes: b. Implementation of a solvent tracking system A solvent tracking system aims to keep control of both the used and unused quantities of solvents (e.g. by weighing unused quantities returned to storage from the application area). c. Monitoring of changes that may influence the uncertainty of the solvent mass balance data Any change that could influence the uncertainty of the solvent mass balance data is recorded, such as: (1) identification and documentation of solvent inputs and outputs (e.g. channelled and diffuse emissions to air, emissions to water, solvent output in waste); (2) substantiated quantification of each relevant solvent input and output and recording of the methodology used (e.g. measurement, estimation by using emission factors, estimation based on operational parameters); (3) identification of the main sources of uncertainty of the aforementioned quantification, and implementation of corrective actions to reduce the uncertainty; (4) regular update of solvent input and output data. (5) malfunctions of the waste gas treatment system: the date and period of time are recorded; (6) changes that may influence air/gas flow rates (e.g. replacement of fans): the date and type of change are recorded. Grp. applicability. This BAT may not apply to the production of polyolefins, PVC or synthetic rubbers. This BAT may not be applicable to plants whose total annual consumption of solvents is lower than 50 tonnes. The level of detail of the solvent mass balance will be proportionate to the nature, scale and complexity of the plant, and the range of environmental impacts it may have, as well as to the type and quantity of solvents used.
identification and documentation of solvent inputs and outputs (e.g. channelled and diffuse emissions to air, emissions to water, solvent output in waste);
substantiated quantification of each relevant solvent input and output and recording of the methodology used (e.g. measurement, estimation by using emission factors, estimation based on operational parameters);
identification of the main sources of uncertainty of the aforementioned quantification, and implementation of corrective actions to reduce the uncertainty;
regular update of solvent input and output data.
malfunctions of the waste gas treatment system: the date and period of time are recorded;
changes that may influence air/gas flow rates (e.g. replacement of fans): the date and type of change are recorded.
BAT 21. Applicability
This BAT may not apply to the production of polyolefins, PVC or synthetic rubbers. This BAT may not be applicable to plants whose total annual consumption of solvents is lower than 50 tonnes. The level of detail of the solvent mass balance will be proportionate to the nature, scale and complexity of the plant, and the range of environmental impacts it may have, as well as to the type and quantity of solvents used.
BAT 22. BAT is to monitor diffuse VOC emissions to air with at least the frequency given below and in accordance with EN standards. If EN standards are not available, BAT is to use ISO, national or other international standards that ensure the provision of data of an equivalent scientific quality. Type of sources of diffuse VOC emissions Type of VOCs Standard(s) Minimum monitoring frequency Sources of fugitive emissions VOCs classified as CMR 1A or 1B EN 15446 Once every year VOCs not classified as CMR 1A or 1B Once during the period covered by each LDAR programme (see BAT 19 point iii.) Sources of non-fugitive emissions VOCs classified as CMR 1A or 1B EN 17628 Once every year VOCs not classified as CMR 1A or 1B Once every year Grp. note. Optical gas imaging (OGI) is a useful complementary technique to the method EN 15446 (sniffing) in order to identify sources of fugitive VOC emissions and is particularly relevant in the case of inaccessible sources (see Section 1.4.2.). This technique is described in EN 17628. In the case of non-fugitive emissions, measurements may be complemented by the use of thermodynamic models. Where large amounts (e.g. above 80 t/yr) of VOCs are used/consumed, the quantification of VOC emissions from the plant with tracer correlation (TC) or with optical absorption-based techniques, such as differential absorption light detection and ranging (DIAL) or solar occultation flux (SOF), is a useful complementary technique (see Section 1.4.2.). These techniques are described in EN 17628. (1) 1 tonne of VOCs per year in the case of VOCs classified as CMR 1A or 1B; or (2) 5 tonnes of VOCs per year in the case of other VOCs. (3) 1 tonne of VOCs per year in the case of VOCs classified as CMR 1A or 1B; or (4) 5 tonnes of VOCs per year in the case of other VOCs. Grp. applicability. BAT 22 only applies when the annual quantity of diffuse VOC emissions from the plant estimated according to BAT 20 is greater than the following: For fugitive emissions: For non-fugitive emissions:
BAT 22. Note
Optical gas imaging (OGI) is a useful complementary technique to the method EN 15446 (sniffing) in order to identify sources of fugitive VOC emissions and is particularly relevant in the case of inaccessible sources (see Section 1.4.2.). This technique is described in EN 17628. In the case of non-fugitive emissions, measurements may be complemented by the use of thermodynamic models. Where large amounts (e.g. above 80 t/yr) of VOCs are used/consumed, the quantification of VOC emissions from the plant with tracer correlation (TC) or with optical absorption-based techniques, such as differential absorption light detection and ranging (DIAL) or solar occultation flux (SOF), is a useful complementary technique (see Section 1.4.2.). These techniques are described in EN 17628.
Applicability
BAT 22 only applies when the annual quantity of diffuse VOC emissions from the plant estimated according to BAT 20 is greater than the following: For fugitive emissions: For non-fugitive emissions: (1) 1 tonne of VOCs per year in the case of VOCs classified as CMR 1A or 1B; or (2) 5 tonnes of VOCs per year in the case of other VOCs. (3) 1 tonne of VOCs per year in the case of VOCs classified as CMR 1A or 1B; or (4) 5 tonnes of VOCs per year in the case of other VOCs.
1 tonne of VOCs per year in the case of VOCs classified as CMR 1A or 1B; or
5 tonnes of VOCs per year in the case of other VOCs.
1 tonne of VOCs per year in the case of VOCs classified as CMR 1A or 1B; or
5 tonnes of VOCs per year in the case of other VOCs.
1.1.4.3. Prevention or reduction of diffuse VOC emissions (1) minimising pipe lengths; (2) reducing the number of pipe connectors (e.g. flanges) and valves; (3) using welded fittings and connections; (4) using compressed air or gravity for material transfer. (5) bellow valves or double packing seals or equally effective equipment; (6) magnetically driven or canned pumps/compressors/agitators, or pumps/compressors/agitators using double seals and a liquid barrier; (7) certified high-quality gaskets (e.g. according to EN 13555) that are tightened according to technique e.; (8) closed sampling system. (9) emissions of CMR substances or substances with acute toxicity; and/or (10) emissions from equipment with high-leaking potential; and/or (11) leaks from processes operated at high pressures (e.g. between 300 bar and 2000 bar). (12) for existing plants; and/or (13) by safety concerns (e.g. avoiding concentrations close to the lower explosive limit). (14) tightening of gaskets by personnel that is qualified according to EN 1591-4 and using the designed gasket stress (e.g. calculated according to EN 1591-1); (15) installing tight caps on open ends; (16) using flanges selected and assembled according to EN 13555. (17) gaskets; (18) sealing elements (e.g. tank lid); (19) packing material (e.g. valve stem packing material). (20) reducing the use of solvents and/or using solvents with lower volatility; (21) reducing the formation of side products containing VOCs; (22) lowering the operating temperature; (23) lowering the VOC content in the final product. (24) reducing the frequency and duration of reactor and vessel openings; (25) preventing corrosion by lining or coating of equipment, by painting pipes (for external corrosion) and by using corrosion inhibitors for materials in contact with equipment. (26) vapour balancing (see Section 1.4.3); (27) closed systems for solid/liquid and liquid/liquid phase separations; (28) closed systems for cleaning operations; (29) closed sewers and/or waste water treatment plants; (30) closed sampling systems; (31) closed storage areas. (32) installing oil creaming systems on open surfaces; (33) periodically skimming open surfaces (e.g. removing floating matter); (34) installing anti-evaporation floating elements on open surfaces; (35) treating waste water streams to remove VOCs and send the VOCs to recovery (see BAT 9 and BAT 10) and/or abatement (see BAT 11); (36) installing floating roofs on tanks; (37) using fixed-roof tanks connected to a waste gas treatment. Grp. 1. The use of techniques to prevent or, where that is not practicable, to reduce diffuse VOC emissions to air is prioritised according to the hazardous properties of the emitted substance(s) and/or the significance of the emissions. Technique Description Type of emissions Applicability Prevention techniques a. Limiting the number of emission sources This includes: Fugitive and non-fugitive emissions Applicability may be restricted by operational constraints in the case of existing plants. b. Use of high-integrity equipment High-integrity equipment includes, but is not limited to: The use of high-integrity equipment is especially relevant to prevent or minimise: High-integrity equipment is selected, installed and maintained according to the type of process and the process operating conditions. Fugitive emissions Applicability may be restricted by operational constraints in the case of existing plants. Generally applicable to new plants and major plant upgrades. c. Collecting diffuse emissions and treating off-gases Collecting diffuse VOC emissions (e.g. from compressor seals, vents and purge lines) and sending them to recovery (see BAT 9 and BAT 10) and/or abatement (see BAT 11). Fugitive and non-fugitive emissions Applicability may be restricted: Other techniques d. Facilitating access and/or monitoring activities To ease maintenance and/or monitoring activities, the access to potentially leaky equipment is facilitated, e.g. by installing platforms, and/or drones are used for monitoring. Fugitive emissions Applicability may be restricted by operational constraints in the case of existing plants. e. Tightening This includes: Fugitive emissions Generally applicable. f. Replacement of leaky equipment and/or parts This includes the replacement of: Fugitive emissions Generally applicable. g. Reviewing and updating process design This includes: Non-fugitive emissions Applicability may be restricted in the case of existing plants due to operational constraints. h. Reviewing and updating operating conditions This includes: Non-fugitive emissions Generally applicable. i. Using closed systems This includes: Off-gases from closed systems are sent to recovery (see BAT 9 and BAT 10) and/or abatement (see BAT 11). Non-fugitive emissions Applicability may be restricted by operational constraints in the case of existing plants and/or by safety concerns. j. Using techniques to minimise emissions from surfaces This includes: Non-fugitive emissions Applicability may be restricted by operational constraints in the case of existing plants. Grp. 23. In order to prevent or, where that is not practicable, to reduce diffuse VOC emissions to air, BAT is to use a combination of the techniques given below with the following order of priority.
1.1.4.3.
BAT 23. In order to prevent or, where that is not practicable, to reduce diffuse VOC emissions to air, BAT is to use a combination of the techniques given below with the following order of priority. (1) minimising pipe lengths; (2) reducing the number of pipe connectors (e.g. flanges) and valves; (3) using welded fittings and connections; (4) using compressed air or gravity for material transfer. (5) bellow valves or double packing seals or equally effective equipment; (6) magnetically driven or canned pumps/compressors/agitators, or pumps/compressors/agitators using double seals and a liquid barrier; (7) certified high-quality gaskets (e.g. according to EN 13555) that are tightened according to technique e.; (8) closed sampling system. (9) emissions of CMR substances or substances with acute toxicity; and/or (10) emissions from equipment with high-leaking potential; and/or (11) leaks from processes operated at high pressures (e.g. between 300 bar and 2000 bar). (12) for existing plants; and/or (13) by safety concerns (e.g. avoiding concentrations close to the lower explosive limit). (14) tightening of gaskets by personnel that is qualified according to EN 1591-4 and using the designed gasket stress (e.g. calculated according to EN 1591-1); (15) installing tight caps on open ends; (16) using flanges selected and assembled according to EN 13555. (17) gaskets; (18) sealing elements (e.g. tank lid); (19) packing material (e.g. valve stem packing material). (20) reducing the use of solvents and/or using solvents with lower volatility; (21) reducing the formation of side products containing VOCs; (22) lowering the operating temperature; (23) lowering the VOC content in the final product. (24) reducing the frequency and duration of reactor and vessel openings; (25) preventing corrosion by lining or coating of equipment, by painting pipes (for external corrosion) and by using corrosion inhibitors for materials in contact with equipment. (26) vapour balancing (see Section 1.4.3); (27) closed systems for solid/liquid and liquid/liquid phase separations; (28) closed systems for cleaning operations; (29) closed sewers and/or waste water treatment plants; (30) closed sampling systems; (31) closed storage areas. (32) installing oil creaming systems on open surfaces; (33) periodically skimming open surfaces (e.g. removing floating matter); (34) installing anti-evaporation floating elements on open surfaces; (35) treating waste water streams to remove VOCs and send the VOCs to recovery (see BAT 9 and BAT 10) and/or abatement (see BAT 11); (36) installing floating roofs on tanks; (37) using fixed-roof tanks connected to a waste gas treatment. Grp. 1. The use of techniques to prevent or, where that is not practicable, to reduce diffuse VOC emissions to air is prioritised according to the hazardous properties of the emitted substance(s) and/or the significance of the emissions. Technique Description Type of emissions Applicability Prevention techniques a. Limiting the number of emission sources This includes: Fugitive and non-fugitive emissions Applicability may be restricted by operational constraints in the case of existing plants. b. Use of high-integrity equipment High-integrity equipment includes, but is not limited to: The use of high-integrity equipment is especially relevant to prevent or minimise: High-integrity equipment is selected, installed and maintained according to the type of process and the process operating conditions. Fugitive emissions Applicability may be restricted by operational constraints in the case of existing plants. Generally applicable to new plants and major plant upgrades. c. Collecting diffuse emissions and treating off-gases Collecting diffuse VOC emissions (e.g. from compressor seals, vents and purge lines) and sending them to recovery (see BAT 9 and BAT 10) and/or abatement (see BAT 11). Fugitive and non-fugitive emissions Applicability may be restricted: Other techniques d. Facilitating access and/or monitoring activities To ease maintenance and/or monitoring activities, the access to potentially leaky equipment is facilitated, e.g. by installing platforms, and/or drones are used for monitoring. Fugitive emissions Applicability may be restricted by operational constraints in the case of existing plants. e. Tightening This includes: Fugitive emissions Generally applicable. f. Replacement of leaky equipment and/or parts This includes the replacement of: Fugitive emissions Generally applicable. g. Reviewing and updating process design This includes: Non-fugitive emissions Applicability may be restricted in the case of existing plants due to operational constraints. h. Reviewing and updating operating conditions This includes: Non-fugitive emissions Generally applicable. i. Using closed systems This includes: Off-gases from closed systems are sent to recovery (see BAT 9 and BAT 10) and/or abatement (see BAT 11). Non-fugitive emissions Applicability may be restricted by operational constraints in the case of existing plants and/or by safety concerns. j. Using techniques to minimise emissions from surfaces This includes: Non-fugitive emissions Applicability may be restricted by operational constraints in the case of existing plants.
BAT 23.
Note 1.2. The use of techniques to prevent or, where that is not practicable, to reduce diffuse VOC emissions to air is prioritised according to the hazardous properties of the emitted substance(s) and/or the significance of the emissions. Technique Description Type of emissions Applicability Prevention techniques a. Limiting the number of emission sources This includes: Fugitive and non-fugitive emissions Applicability may be restricted by operational constraints in the case of existing plants. b. Use of high-integrity equipment High-integrity equipment includes, but is not limited to: The use of high-integrity equipment is especially relevant to prevent or minimise: High-integrity equipment is selected, installed and maintained according to the type of process and the process operating conditions. Fugitive emissions Applicability may be restricted by operational constraints in the case of existing plants. Generally applicable to new plants and major plant upgrades. c. Collecting diffuse emissions and treating off-gases Collecting diffuse VOC emissions (e.g. from compressor seals, vents and purge lines) and sending them to recovery (see BAT 9 and BAT 10) and/or abatement (see BAT 11). Fugitive and non-fugitive emissions Applicability may be restricted: Other techniques d. Facilitating access and/or monitoring activities To ease maintenance and/or monitoring activities, the access to potentially leaky equipment is facilitated, e.g. by installing platforms, and/or drones are used for monitoring. Fugitive emissions Applicability may be restricted by operational constraints in the case of existing plants. e. Tightening This includes: Fugitive emissions Generally applicable. f. Replacement of leaky equipment and/or parts This includes the replacement of: Fugitive emissions Generally applicable. g. Reviewing and updating process design This includes: Non-fugitive emissions Applicability may be restricted in the case of existing plants due to operational constraints. h. Reviewing and updating operating conditions This includes: Non-fugitive emissions Generally applicable. i. Using closed systems This includes: Off-gases from closed systems are sent to recovery (see BAT 9 and BAT 10) and/or abatement (see BAT 11). Non-fugitive emissions Applicability may be restricted by operational constraints in the case of existing plants and/or by safety concerns. j. Using techniques to minimise emissions from surfaces This includes: Non-fugitive emissions Applicability may be restricted by operational constraints in the case of existing plants. (1) minimising pipe lengths; (2) reducing the number of pipe connectors (e.g. flanges) and valves; (3) using welded fittings and connections; (4) using compressed air or gravity for material transfer. (5) bellow valves or double packing seals or equally effective equipment; (6) magnetically driven or canned pumps/compressors/agitators, or pumps/compressors/agitators using double seals and a liquid barrier; (7) certified high-quality gaskets (e.g. according to EN 13555) that are tightened according to technique e.; (8) closed sampling system. (9) emissions of CMR substances or substances with acute toxicity; and/or (10) emissions from equipment with high-leaking potential; and/or (11) leaks from processes operated at high pressures (e.g. between 300 bar and 2000 bar). (12) for existing plants; and/or (13) by safety concerns (e.g. avoiding concentrations close to the lower explosive limit). (14) tightening of gaskets by personnel that is qualified according to EN 1591-4 and using the designed gasket stress (e.g. calculated according to EN 1591-1); (15) installing tight caps on open ends; (16) using flanges selected and assembled according to EN 13555. (17) gaskets; (18) sealing elements (e.g. tank lid); (19) packing material (e.g. valve stem packing material). (20) reducing the use of solvents and/or using solvents with lower volatility; (21) reducing the formation of side products containing VOCs; (22) lowering the operating temperature; (23) lowering the VOC content in the final product. (24) reducing the frequency and duration of reactor and vessel openings; (25) preventing corrosion by lining or coating of equipment, by painting pipes (for external corrosion) and by using corrosion inhibitors for materials in contact with equipment. (26) vapour balancing (see Section 1.4.3); (27) closed systems for solid/liquid and liquid/liquid phase separations; (28) closed systems for cleaning operations; (29) closed sewers and/or waste water treatment plants; (30) closed sampling systems; (31) closed storage areas. (32) installing oil creaming systems on open surfaces; (33) periodically skimming open surfaces (e.g. removing floating matter); (34) installing anti-evaporation floating elements on open surfaces; (35) treating waste water streams to remove VOCs and send the VOCs to recovery (see BAT 9 and BAT 10) and/or abatement (see BAT 11); (36) installing floating roofs on tanks; (37) using fixed-roof tanks connected to a waste gas treatment.
minimising pipe lengths;
reducing the number of pipe connectors (e.g. flanges) and valves;
using welded fittings and connections;
using compressed air or gravity for material transfer.
bellow valves or double packing seals or equally effective equipment;
magnetically driven or canned pumps/compressors/agitators, or pumps/compressors/agitators using double seals and a liquid barrier;
certified high-quality gaskets (e.g. according to EN 13555) that are tightened according to technique e.;
closed sampling system.
emissions of CMR substances or substances with acute toxicity; and/or
emissions from equipment with high-leaking potential; and/or
leaks from processes operated at high pressures (e.g. between 300 bar and 2000 bar).
for existing plants; and/or
by safety concerns (e.g. avoiding concentrations close to the lower explosive limit).
tightening of gaskets by personnel that is qualified according to EN 1591-4 and using the designed gasket stress (e.g. calculated according to EN 1591-1);
installing tight caps on open ends;
using flanges selected and assembled according to EN 13555.
gaskets;
sealing elements (e.g. tank lid);
packing material (e.g. valve stem packing material).
reducing the use of solvents and/or using solvents with lower volatility;
reducing the formation of side products containing VOCs;
lowering the operating temperature;
lowering the VOC content in the final product.
reducing the frequency and duration of reactor and vessel openings;
preventing corrosion by lining or coating of equipment, by painting pipes (for external corrosion) and by using corrosion inhibitors for materials in contact with equipment.
vapour balancing (see Section 1.4.3);
closed systems for solid/liquid and liquid/liquid phase separations;
closed systems for cleaning operations;
closed sewers and/or waste water treatment plants;
closed sampling systems;
closed storage areas.
installing oil creaming systems on open surfaces;
periodically skimming open surfaces (e.g. removing floating matter);
installing anti-evaporation floating elements on open surfaces;
treating waste water streams to remove VOCs and send the VOCs to recovery (see BAT 9 and BAT 10) and/or abatement (see BAT 11);
installing floating roofs on tanks;
using fixed-roof tanks connected to a waste gas treatment.
1.1.4.4. Table 1.7 BAT-associated emission level (BAT-AEL) for diffuse VOC emissions to air from the use of solvents or the reuse of recovered solvents
BAT conclusions for the use of solvents or the reuse of recovered solvents The emission levels for the use of solvents or the reuse of recovered solvents given below are associated with the general BAT conclusions given in Section 1.1 and Section 1.1.4.3. Parameter BAT-AEL (percentage of the solvent inputs) (yearly average) Diffuse VOC emissions ≤ 5 % The associated monitoring is given in BAT 20, BAT 21 and BAT 22.
1.2. Polymers and synthetic rubbers The BAT conclusions presented in this section apply to the production of certain polymers. They apply in addition to the general BAT conclusions given in Section 1.1. Grp. note. The measurement samples are taken at the point of transition from the closed to the open system where the polyolefin comes into contact with the atmosphere. The closed system refers to the part of the production process where the materials (e.g. reactants, solvents, suspension agents) are not in contact with the atmosphere. It includes the polymerisation steps, the reuse and recovery of materials. The open system refers to the part of the production process where the polyolefins come into contact with the atmosphere. It includes the finishing steps (e.g. drying, blending) as well as the transfer, handling and storage of polyolefins. When the transition point between the open and the closed system cannot be clearly identified, the measurement samples are taken at an appropriate point. Grp. applicability. Measurements do not apply to production processes only made up of a closed system. Grp. 24. BAT is to monitor the TVOC concentration in polyolefin products, at least once every year for each representative polyolefin grade produced during the same year, in accordance with EN standards. If EN standards are not available, BAT is to use ISO, national or other international standards that ensure the provision of data of an equivalent scientific quality. Polyolefin product Standard(s) Monitoring associated with HDPE, LDPE, LLDPE No EN standard available BAT 20, BAT 25 PP EPS, GPPS, HIPS Grp_25_table. 18. In order to increase resource efficiency and to reduce emissions to air of organic compounds, BAT is to use all of the techniques given below, as far as applicable. Technique Description Applicability a. Chemical agents with low boiling points Solvents and suspension agents with low boiling points are used. Applicability may be restricted by operational constraints. b. Lowering the VOC content in the polymer The VOC content in the polymer is lowered, e.g. by using low-pressure separation, stripping or closed-loop nitrogen purge systems, devolatilisation extrusion (see Section 1.4.3). The techniques for lowering the VOC content depend on the type of polymer product and production process. Devolatilisation extrusion may be restricted by product specifications for the production of HDPE, LDPE and LLDPE. c. Collection and treatment of process off-gases Process off-gases arising from the use of technique b. as well as from the finishing step, e.g. extrusion and degassing silos, are collected and sent to recovery (see BAT 9 and BAT 10) and/or abatement (see BAT 11). Applicability may be restricted by operational constraints and/or due to safety concerns (e.g. avoiding concentrations close to the lower/upper explosive limit). Polyolefin product Unit BAT-AEL (Yearly average) HDPE g C per kg of polyolefins produced 0,3-1,0 LDPE 0,1-1,4 LLDPE 0,1-0,8 PP 0,1-0,9 GPPS and HIPS < 0,1 EPS < 0,6 The associated monitoring is given in BAT 8, BAT 20, BAT 22 and BAT 24. The monitoring of TVOC emissions to air includes all emissions from the following process steps, where the emissions are identified as relevant in the inventory given in BAT 2: storage and handling of raw materials, polymerisation, recovery of materials and pollutant abatement, finishing of the polymer (e.g. extrusion, drying, blending) as well as the transfer, handling and storage of polymers. Grp. 121. BAT conclusions for the production of polyolefins Grp. 26. BAT is to monitor channelled emissions to air with at least the frequency given below and in accordance with EN standards. If EN standards are not available, BAT is to use ISO, national or other international standards that ensure the provision of data of an equivalent scientific quality. Substance Emission points Standard(s) Minimum monitoring frequency Monitoring associated with VCM Any stack with a VCM mass flow of ≥ 25 g/h Generic EN standards Continuous BAT 29 Any stack with a VCM mass flow of < 25 g/h No EN standard available Once every 6 months Grp. note. The samples of the PVC slurry/latex are taken at the point of transition from the closed to the open system where the PVC slurry/latex comes into contact with the atmosphere. The closed system refers to the part of the production process where the PVC slurry/latex is not in contact with the atmosphere. It generally includes the polymerisation steps, the reuse and recovery of VCM. The open system is the part of the system where the PVC slurry/latex comes into contact with the atmosphere. It includes the finishing steps (e.g. drying and blending) as well as the transfer, handling and storage of PVC. Grp. 27. BAT is to monitor the residual vinyl chloride monomer concentration in PVC slurry/latex, at least once every year for each representative PVC grade produced during the same year, in accordance with EN standards. Substance Standard(s) Monitoring associated with VCM EN ISO 6401 BAT 30 Grp. applicability. Recovery may be restricted where the energy demand is excessive due to the low concentration of the compound(s) concerned in the process off-gas(es). Grp. 28. In order to increase resource efficiency and to reduce the mass flow of organic compounds sent to the final waste gas treatment, BAT is to recover the vinyl chloride monomer from process off-gases by using one or a combination of the techniques given below, and to reuse the recovered monomer. Technique Description a. Absorption (regenerative) See Section 1.4.1. b. Adsorption (regenerative) See Section 1.4.1. c. Condensation See Section 1.4.1. Grp_29_table. 19. In order to reduce channelled emissions to air of vinyl chloride monomer from the recovery of vinyl chloride monomer, BAT is to use one or a combination of the techniques given below. Technique Description Applicability a. Absorption See Section 1.4.1. Generally applicable b. Adsorption See Section 1.4.1. c. Condensation See Section 1.4.1. d. Thermal oxidation See Section 1.4.1. Applicability of recuperative and regenerative thermal oxidation to existing plants may be restricted by design and/or operational constraints. Applicability may be restricted where the energy demand is excessive due to the low concentration of the compound(s) concerned in the process off-gases. Substance BAT-AEL (mg/Nm3) (Daily average or average over the sampling period) VCM < 0,5-1 The associated monitoring is given in BAT 26. (1) storing VCM in refrigerated tanks at atmospheric pressure or in pressurised tanks at ambient temperature; (2) using refrigerated reflux condensers or connecting tanks for VCM recovery (see BAT 28) and/or abatement (see BAT 29). (3) reducing the frequency and duration of reactor openings; (4) venting off-gases from latex storage tanks and from connections to VCM recovery (see BAT 28) and/or abatement (see BAT 29) prior to opening the reactor; (5) flushing the reactor with inert gas prior to opening and venting off-gases to VCM recovery (see BAT 28) and/or abatement (see BAT 29); (6) draining the liquid content of the reactor to closed vessels prior to opening the reactor; (7) cleaning the reactor with water prior to opening and draining the water to the stripping system. Grp. 30. In order to reduce emissions to air of vinyl chloride monomer, BAT is to use all of the techniques given below. Technique Description a. Appropriate VCM storage facilities This includes: b. Vapour balancing See Section 1.4.3. c. Minimisation of emissions of residual VCM from equipment This includes: d. Lowering the VCM content in the polymer by stripping See Section 1.4.3. e. Collection and treatment of process off-gases Process off-gases from the use of technique d. are collected and sent to VCM recovery (see BAT 28) and/or abatement (see BAT 29). PVC type Unit BAT-AEL (Yearly average) S-PVC g VCM per kg of PVC produced 0,01-0,045 E-PVC 0,25-0,3 The associated monitoring is given in BAT 20, BAT 22, BAT 26 and BAT 27. The monitoring of VCM emissions to air includes all emissions from the following process steps or equipment, where the emissions are identified as relevant in the inventory given in BAT 2: finishing, e.g. drying and blending; transfer, handling and storage; reactor openings; gasholders; waste water treatment plants; recovery and/or abatement of VCM. PVC type Unit BAT-AEL (Yearly average) S-PVC g VCM per kg of PVC produced 0,01-0,03 E-PVC 0,2-0,4 The associated monitoring is given in BAT 27. Grp. 122. BAT conclusions for the production of polyvinyl chloride (PVC) Grp. note. The samples are taken after lowering the VOC content in the polymer (see BAT 32 a.) where the synthetic rubber comes into contact with the atmosphere. Grp. applicability. Measurements do not apply to production processes only made up of a closed system. Grp. 31. BAT is to monitor the TVOC concentration in synthetic rubbers, at least once every year for each representative synthetic rubber grade produced during the same year, in accordance with EN standards. If EN standards are not available, BAT is to use ISO, national or other international standards that ensure the provision of data of an equivalent scientific quality. Substance/Parameter Standard(s) Monitoring associated with VOCs No EN standard available BAT 32 Grp_32_table. 112. In order to reduce emissions to air of organic compounds, BAT is to use one or a combination of the techniques given below. Technique Description a. Lowering the VOC content in the polymer The VOC content in the polymer is lowered by using stripping or devolatilisation extrusion (see Section 1.4.3). b. Collection and treatment of process off-gases Process off-gases are collected and sent to recovery (see BAT 9 and BAT 10) and/or abatement (see BAT 11). Substance/Parameter Unit BAT-AEL (Yearly average) TVOC g C per kg of synthetic rubber produced 0,2-4,2 The associated monitoring is given in BAT 8, BAT 20, BAT 22 and BAT 31. The monitoring of TVOC emissions to air includes all emissions from the following process steps, where the emissions are identified as relevant in the inventory given in BAT 2: storage of raw materials, polymerisation, recovery of materials and abatement techniques, finishing of the polymer (e.g. extrusion, drying, blending) as well as the transfer, handling and storage of synthetic rubbers. Grp. 123. BAT conclusions for the production of synthetic rubbers Grp. 33. BAT is to monitor channelled emissions to air with at least the frequency given below and in accordance with EN standards. If EN standards are not available, BAT is to use ISO, national or other international standards that ensure the provision of data of an equivalent scientific quality. Substance Emission points Standard(s) Minimum monitoring frequency Monitoring associated with Carbon disulphide (CS2) Any stack with a mass flow of ≥ 1 kg/h Generic EN standards Continuous BAT 35 Any stack with a mass flow of < 1 kg/h No EN standard available Once every year Hydrogen sulphide (H2S) Any stack with a mass flow of ≥ 50 g/h Generic EN standards Continuous Any stack with a mass flow of < 50 g/h No EN standard available Once every year Grp. 34. In order to increase resource efficiency and to reduce the mass flow of CS2 and H2S sent to the final waste gas treatment, BAT is to recover CS2 by using technique a. and/or technique b. or a combination of technique c. with technique(s) a. and/or b., given below and to reuse the CS2, or, alternatively, to use technique d. Technique Main substance targeted Description Applicability a. Absorption (regenerative) H2S See Section 1.4.1. Generally applicable for the production of casing. For other products, applicability may be restricted where the energy demand is excessive due to high waste gas volume flows (above e.g. 120000 Nm3/h) or low H2S concentration in the waste gas (below e.g. 0,5 g/Nm3). b. Adsorption (regenerative) H2S, CS2 See Section 1.4.1. Applicability may be restricted where the energy demand for recovery is excessive if the concentration of CS2 in the waste gas is below e.g. 5 g/Nm3. c. Condensation H2S, CS2 See Section 1.4.1. d. Production of sulphuric acid H2S, CS2 Process off-gases containing CS2 and H2S are used to produce sulphuric acid. Applicability may be restricted if the concentration of CS2 and/or H2S in the waste gas is below 5 g/Nm3. Grp_35_table. 113. In order to reduce channelled emissions to air of CS2 and H2S, BAT is to use one or a combination of the techniques given below. Technique Main substance targeted Description Applicability a. Absorption H2S See Section 1.4.1. Generally applicable. b. Bioprocesses CS2, H2S See Section 1.4.1. Applicability may be restricted where the energy demand is excessive due to high waste gas volume flows (e.g. above 60000 Nm3/h) or high CS2 concentration in the waste gas (e.g. above 1 000 mg/Nm3) or too low H2S concentration. c. Thermal oxidation CS2, H2S See Section 1.4.1. Applicability of recuperative and regenerative thermal oxidation to existing plants may be restricted by design and/or operational constraints. Applicability may be restricted where the energy demand is excessive due to the low concentration of the compound(s) concerned in the process off-gases. Substance BAT-AEL (mg/Nm3) (Daily average or average over the sampling period) CS2 5-400 H2S 1-10 The associated monitoring is given in BAT 33. Parameter Process Unit BAT-AEL (Yearly average) Sum of H2S and CS2 (expressed as Total S) Production of staple fibres g Total S per kg of product 6-9 Casing 120-250 The associated monitoring is given in BAT 33. Grp. 124. BAT conclusions for the production of viscose using CS2
1.2.
1.2.1. BAT conclusions for the production of polyolefins Grp. note. The measurement samples are taken at the point of transition from the closed to the open system where the polyolefin comes into contact with the atmosphere. The closed system refers to the part of the production process where the materials (e.g. reactants, solvents, suspension agents) are not in contact with the atmosphere. It includes the polymerisation steps, the reuse and recovery of materials. The open system refers to the part of the production process where the polyolefins come into contact with the atmosphere. It includes the finishing steps (e.g. drying, blending) as well as the transfer, handling and storage of polyolefins. When the transition point between the open and the closed system cannot be clearly identified, the measurement samples are taken at an appropriate point. Grp. applicability. Measurements do not apply to production processes only made up of a closed system. Grp. 24. BAT is to monitor the TVOC concentration in polyolefin products, at least once every year for each representative polyolefin grade produced during the same year, in accordance with EN standards. If EN standards are not available, BAT is to use ISO, national or other international standards that ensure the provision of data of an equivalent scientific quality. Polyolefin product Standard(s) Monitoring associated with HDPE, LDPE, LLDPE No EN standard available BAT 20, BAT 25 PP EPS, GPPS, HIPS Grp_25_table. 18. In order to increase resource efficiency and to reduce emissions to air of organic compounds, BAT is to use all of the techniques given below, as far as applicable. Technique Description Applicability a. Chemical agents with low boiling points Solvents and suspension agents with low boiling points are used. Applicability may be restricted by operational constraints. b. Lowering the VOC content in the polymer The VOC content in the polymer is lowered, e.g. by using low-pressure separation, stripping or closed-loop nitrogen purge systems, devolatilisation extrusion (see Section 1.4.3). The techniques for lowering the VOC content depend on the type of polymer product and production process. Devolatilisation extrusion may be restricted by product specifications for the production of HDPE, LDPE and LLDPE. c. Collection and treatment of process off-gases Process off-gases arising from the use of technique b. as well as from the finishing step, e.g. extrusion and degassing silos, are collected and sent to recovery (see BAT 9 and BAT 10) and/or abatement (see BAT 11). Applicability may be restricted by operational constraints and/or due to safety concerns (e.g. avoiding concentrations close to the lower/upper explosive limit). Polyolefin product Unit BAT-AEL (Yearly average) HDPE g C per kg of polyolefins produced 0,3-1,0 LDPE 0,1-1,4 LLDPE 0,1-0,8 PP 0,1-0,9 GPPS and HIPS < 0,1 EPS < 0,6 The associated monitoring is given in BAT 8, BAT 20, BAT 22 and BAT 24. The monitoring of TVOC emissions to air includes all emissions from the following process steps, where the emissions are identified as relevant in the inventory given in BAT 2: storage and handling of raw materials, polymerisation, recovery of materials and pollutant abatement, finishing of the polymer (e.g. extrusion, drying, blending) as well as the transfer, handling and storage of polymers.
1.2.1.
BAT 24. BAT is to monitor the TVOC concentration in polyolefin products, at least once every year for each representative polyolefin grade produced during the same year, in accordance with EN standards. If EN standards are not available, BAT is to use ISO, national or other international standards that ensure the provision of data of an equivalent scientific quality. Polyolefin product Standard(s) Monitoring associated with HDPE, LDPE, LLDPE No EN standard available BAT 20, BAT 25 PP EPS, GPPS, HIPS Grp. note. The measurement samples are taken at the point of transition from the closed to the open system where the polyolefin comes into contact with the atmosphere. The closed system refers to the part of the production process where the materials (e.g. reactants, solvents, suspension agents) are not in contact with the atmosphere. It includes the polymerisation steps, the reuse and recovery of materials. The open system refers to the part of the production process where the polyolefins come into contact with the atmosphere. It includes the finishing steps (e.g. drying, blending) as well as the transfer, handling and storage of polyolefins. When the transition point between the open and the closed system cannot be clearly identified, the measurement samples are taken at an appropriate point. Grp. applicability. Measurements do not apply to production processes only made up of a closed system.
BAT 24. Note
The measurement samples are taken at the point of transition from the closed to the open system where the polyolefin comes into contact with the atmosphere. The closed system refers to the part of the production process where the materials (e.g. reactants, solvents, suspension agents) are not in contact with the atmosphere. It includes the polymerisation steps, the reuse and recovery of materials. The open system refers to the part of the production process where the polyolefins come into contact with the atmosphere. It includes the finishing steps (e.g. drying, blending) as well as the transfer, handling and storage of polyolefins. When the transition point between the open and the closed system cannot be clearly identified, the measurement samples are taken at an appropriate point.
Applicability
Measurements do not apply to production processes only made up of a closed system.
BAT 25. Table 1.8 BAT-associated emission levels (BAT-AELs) for total emissions to air of VOCs from the production of polyolefins expressed as specific emission loads
In order to increase resource efficiency and to reduce emissions to air of organic compounds, BAT is to use all of the techniques given below, as far as applicable. Technique Description Applicability a. Chemical agents with low boiling points Solvents and suspension agents with low boiling points are used. Applicability may be restricted by operational constraints. b. Lowering the VOC content in the polymer The VOC content in the polymer is lowered, e.g. by using low-pressure separation, stripping or closed-loop nitrogen purge systems, devolatilisation extrusion (see Section 1.4.3). The techniques for lowering the VOC content depend on the type of polymer product and production process. Devolatilisation extrusion may be restricted by product specifications for the production of HDPE, LDPE and LLDPE. c. Collection and treatment of process off-gases Process off-gases arising from the use of technique b. as well as from the finishing step, e.g. extrusion and degassing silos, are collected and sent to recovery (see BAT 9 and BAT 10) and/or abatement (see BAT 11). Applicability may be restricted by operational constraints and/or due to safety concerns (e.g. avoiding concentrations close to the lower/upper explosive limit). Polyolefin product Unit BAT-AEL (Yearly average) HDPE g C per kg of polyolefins produced 0,3-1,0 LDPE 0,1-1,4 LLDPE 0,1-0,8 PP 0,1-0,9 GPPS and HIPS < 0,1 EPS < 0,6 The associated monitoring is given in BAT 8, BAT 20, BAT 22 and BAT 24. The monitoring of TVOC emissions to air includes all emissions from the following process steps, where the emissions are identified as relevant in the inventory given in BAT 2: storage and handling of raw materials, polymerisation, recovery of materials and pollutant abatement, finishing of the polymer (e.g. extrusion, drying, blending) as well as the transfer, handling and storage of polymers.
1.2.2. BAT conclusions for the production of polyvinyl chloride (PVC) Grp. 26. BAT is to monitor channelled emissions to air with at least the frequency given below and in accordance with EN standards. If EN standards are not available, BAT is to use ISO, national or other international standards that ensure the provision of data of an equivalent scientific quality. Substance Emission points Standard(s) Minimum monitoring frequency Monitoring associated with VCM Any stack with a VCM mass flow of ≥ 25 g/h Generic EN standards Continuous BAT 29 Any stack with a VCM mass flow of < 25 g/h No EN standard available Once every 6 months Grp. note. The samples of the PVC slurry/latex are taken at the point of transition from the closed to the open system where the PVC slurry/latex comes into contact with the atmosphere. The closed system refers to the part of the production process where the PVC slurry/latex is not in contact with the atmosphere. It generally includes the polymerisation steps, the reuse and recovery of VCM. The open system is the part of the system where the PVC slurry/latex comes into contact with the atmosphere. It includes the finishing steps (e.g. drying and blending) as well as the transfer, handling and storage of PVC. Grp. 27. BAT is to monitor the residual vinyl chloride monomer concentration in PVC slurry/latex, at least once every year for each representative PVC grade produced during the same year, in accordance with EN standards. Substance Standard(s) Monitoring associated with VCM EN ISO 6401 BAT 30 Grp. applicability. Recovery may be restricted where the energy demand is excessive due to the low concentration of the compound(s) concerned in the process off-gas(es). Grp. 28. In order to increase resource efficiency and to reduce the mass flow of organic compounds sent to the final waste gas treatment, BAT is to recover the vinyl chloride monomer from process off-gases by using one or a combination of the techniques given below, and to reuse the recovered monomer. Technique Description a. Absorption (regenerative) See Section 1.4.1. b. Adsorption (regenerative) See Section 1.4.1. c. Condensation See Section 1.4.1. Grp_29_table. 19. In order to reduce channelled emissions to air of vinyl chloride monomer from the recovery of vinyl chloride monomer, BAT is to use one or a combination of the techniques given below. Technique Description Applicability a. Absorption See Section 1.4.1. Generally applicable b. Adsorption See Section 1.4.1. c. Condensation See Section 1.4.1. d. Thermal oxidation See Section 1.4.1. Applicability of recuperative and regenerative thermal oxidation to existing plants may be restricted by design and/or operational constraints. Applicability may be restricted where the energy demand is excessive due to the low concentration of the compound(s) concerned in the process off-gases. Substance BAT-AEL (mg/Nm3) (Daily average or average over the sampling period) VCM < 0,5-1 The associated monitoring is given in BAT 26. (1) storing VCM in refrigerated tanks at atmospheric pressure or in pressurised tanks at ambient temperature; (2) using refrigerated reflux condensers or connecting tanks for VCM recovery (see BAT 28) and/or abatement (see BAT 29). (3) reducing the frequency and duration of reactor openings; (4) venting off-gases from latex storage tanks and from connections to VCM recovery (see BAT 28) and/or abatement (see BAT 29) prior to opening the reactor; (5) flushing the reactor with inert gas prior to opening and venting off-gases to VCM recovery (see BAT 28) and/or abatement (see BAT 29); (6) draining the liquid content of the reactor to closed vessels prior to opening the reactor; (7) cleaning the reactor with water prior to opening and draining the water to the stripping system. Grp. 30. In order to reduce emissions to air of vinyl chloride monomer, BAT is to use all of the techniques given below. Technique Description a. Appropriate VCM storage facilities This includes: b. Vapour balancing See Section 1.4.3. c. Minimisation of emissions of residual VCM from equipment This includes: d. Lowering the VCM content in the polymer by stripping See Section 1.4.3. e. Collection and treatment of process off-gases Process off-gases from the use of technique d. are collected and sent to VCM recovery (see BAT 28) and/or abatement (see BAT 29). PVC type Unit BAT-AEL (Yearly average) S-PVC g VCM per kg of PVC produced 0,01-0,045 E-PVC 0,25-0,3 The associated monitoring is given in BAT 20, BAT 22, BAT 26 and BAT 27. The monitoring of VCM emissions to air includes all emissions from the following process steps or equipment, where the emissions are identified as relevant in the inventory given in BAT 2: finishing, e.g. drying and blending; transfer, handling and storage; reactor openings; gasholders; waste water treatment plants; recovery and/or abatement of VCM. PVC type Unit BAT-AEL (Yearly average) S-PVC g VCM per kg of PVC produced 0,01-0,03 E-PVC 0,2-0,4 The associated monitoring is given in BAT 27.
1.2.2.
BAT 26. BAT is to monitor channelled emissions to air with at least the frequency given below and in accordance with EN standards. If EN standards are not available, BAT is to use ISO, national or other international standards that ensure the provision of data of an equivalent scientific quality. Substance Emission points Standard(s) Minimum monitoring frequency Monitoring associated with VCM Any stack with a VCM mass flow of ≥ 25 g/h Generic EN standards Continuous BAT 29 Any stack with a VCM mass flow of < 25 g/h No EN standard available Once every 6 months
BAT 27. BAT is to monitor the residual vinyl chloride monomer concentration in PVC slurry/latex, at least once every year for each representative PVC grade produced during the same year, in accordance with EN standards. Substance Standard(s) Monitoring associated with VCM EN ISO 6401 BAT 30 Grp. note. The samples of the PVC slurry/latex are taken at the point of transition from the closed to the open system where the PVC slurry/latex comes into contact with the atmosphere. The closed system refers to the part of the production process where the PVC slurry/latex is not in contact with the atmosphere. It generally includes the polymerisation steps, the reuse and recovery of VCM. The open system is the part of the system where the PVC slurry/latex comes into contact with the atmosphere. It includes the finishing steps (e.g. drying and blending) as well as the transfer, handling and storage of PVC.
BAT 27. Note
The samples of the PVC slurry/latex are taken at the point of transition from the closed to the open system where the PVC slurry/latex comes into contact with the atmosphere. The closed system refers to the part of the production process where the PVC slurry/latex is not in contact with the atmosphere. It generally includes the polymerisation steps, the reuse and recovery of VCM. The open system is the part of the system where the PVC slurry/latex comes into contact with the atmosphere. It includes the finishing steps (e.g. drying and blending) as well as the transfer, handling and storage of PVC.
BAT 28. In order to increase resource efficiency and to reduce the mass flow of organic compounds sent to the final waste gas treatment, BAT is to recover the vinyl chloride monomer from process off-gases by using one or a combination of the techniques given below, and to reuse the recovered monomer. Technique Description a. Absorption (regenerative) See Section 1.4.1. b. Adsorption (regenerative) See Section 1.4.1. c. Condensation See Section 1.4.1. Grp. applicability. Recovery may be restricted where the energy demand is excessive due to the low concentration of the compound(s) concerned in the process off-gas(es).
BAT 28. Applicability
Recovery may be restricted where the energy demand is excessive due to the low concentration of the compound(s) concerned in the process off-gas(es).
BAT 29. Table 1.9 BAT-associated emission level (BAT-AEL) for channelled emissions to air of VCM from the recovery of VCM
In order to reduce channelled emissions to air of vinyl chloride monomer from the recovery of vinyl chloride monomer, BAT is to use one or a combination of the techniques given below. Technique Description Applicability a. Absorption See Section 1.4.1. Generally applicable b. Adsorption See Section 1.4.1. c. Condensation See Section 1.4.1. d. Thermal oxidation See Section 1.4.1. Applicability of recuperative and regenerative thermal oxidation to existing plants may be restricted by design and/or operational constraints. Applicability may be restricted where the energy demand is excessive due to the low concentration of the compound(s) concerned in the process off-gases. Substance BAT-AEL (mg/Nm3) (Daily average or average over the sampling period) VCM < 0,5-1 The associated monitoring is given in BAT 26.
BAT 30. Table 1.10 Table 1.11 BAT-associated emission levels (BAT-AELs) for total emissions to air of VCM from the production of PVC expressed as specific emission loads BAT-associated emission levels (BAT-AELs) for the VCM concentration in the PVC slurry/latex
In order to reduce emissions to air of vinyl chloride monomer, BAT is to use all of the techniques given below. Technique Description a. Appropriate VCM storage facilities This includes: b. Vapour balancing See Section 1.4.3. c. Minimisation of emissions of residual VCM from equipment This includes: d. Lowering the VCM content in the polymer by stripping See Section 1.4.3. e. Collection and treatment of process off-gases Process off-gases from the use of technique d. are collected and sent to VCM recovery (see BAT 28) and/or abatement (see BAT 29). PVC type Unit BAT-AEL (Yearly average) S-PVC g VCM per kg of PVC produced 0,01-0,045 E-PVC 0,25-0,3 The associated monitoring is given in BAT 20, BAT 22, BAT 26 and BAT 27. The monitoring of VCM emissions to air includes all emissions from the following process steps or equipment, where the emissions are identified as relevant in the inventory given in BAT 2: finishing, e.g. drying and blending; transfer, handling and storage; reactor openings; gasholders; waste water treatment plants; recovery and/or abatement of VCM. PVC type Unit BAT-AEL (Yearly average) S-PVC g VCM per kg of PVC produced 0,01-0,03 E-PVC 0,2-0,4 The associated monitoring is given in BAT 27. (1) storing VCM in refrigerated tanks at atmospheric pressure or in pressurised tanks at ambient temperature; (2) using refrigerated reflux condensers or connecting tanks for VCM recovery (see BAT 28) and/or abatement (see BAT 29). (3) reducing the frequency and duration of reactor openings; (4) venting off-gases from latex storage tanks and from connections to VCM recovery (see BAT 28) and/or abatement (see BAT 29) prior to opening the reactor; (5) flushing the reactor with inert gas prior to opening and venting off-gases to VCM recovery (see BAT 28) and/or abatement (see BAT 29); (6) draining the liquid content of the reactor to closed vessels prior to opening the reactor; (7) cleaning the reactor with water prior to opening and draining the water to the stripping system.
storing VCM in refrigerated tanks at atmospheric pressure or in pressurised tanks at ambient temperature;
using refrigerated reflux condensers or connecting tanks for VCM recovery (see BAT 28) and/or abatement (see BAT 29).
reducing the frequency and duration of reactor openings;
venting off-gases from latex storage tanks and from connections to VCM recovery (see BAT 28) and/or abatement (see BAT 29) prior to opening the reactor;
flushing the reactor with inert gas prior to opening and venting off-gases to VCM recovery (see BAT 28) and/or abatement (see BAT 29);
draining the liquid content of the reactor to closed vessels prior to opening the reactor;
cleaning the reactor with water prior to opening and draining the water to the stripping system.
1.2.3. BAT conclusions for the production of synthetic rubbers Grp. note. The samples are taken after lowering the VOC content in the polymer (see BAT 32 a.) where the synthetic rubber comes into contact with the atmosphere. Grp. applicability. Measurements do not apply to production processes only made up of a closed system. Grp. 31. BAT is to monitor the TVOC concentration in synthetic rubbers, at least once every year for each representative synthetic rubber grade produced during the same year, in accordance with EN standards. If EN standards are not available, BAT is to use ISO, national or other international standards that ensure the provision of data of an equivalent scientific quality. Substance/Parameter Standard(s) Monitoring associated with VOCs No EN standard available BAT 32 Grp_32_table. 112. In order to reduce emissions to air of organic compounds, BAT is to use one or a combination of the techniques given below. Technique Description a. Lowering the VOC content in the polymer The VOC content in the polymer is lowered by using stripping or devolatilisation extrusion (see Section 1.4.3). b. Collection and treatment of process off-gases Process off-gases are collected and sent to recovery (see BAT 9 and BAT 10) and/or abatement (see BAT 11). Substance/Parameter Unit BAT-AEL (Yearly average) TVOC g C per kg of synthetic rubber produced 0,2-4,2 The associated monitoring is given in BAT 8, BAT 20, BAT 22 and BAT 31. The monitoring of TVOC emissions to air includes all emissions from the following process steps, where the emissions are identified as relevant in the inventory given in BAT 2: storage of raw materials, polymerisation, recovery of materials and abatement techniques, finishing of the polymer (e.g. extrusion, drying, blending) as well as the transfer, handling and storage of synthetic rubbers.
1.2.3.
BAT 31. BAT is to monitor the TVOC concentration in synthetic rubbers, at least once every year for each representative synthetic rubber grade produced during the same year, in accordance with EN standards. If EN standards are not available, BAT is to use ISO, national or other international standards that ensure the provision of data of an equivalent scientific quality. Substance/Parameter Standard(s) Monitoring associated with VOCs No EN standard available BAT 32 Grp. note. The samples are taken after lowering the VOC content in the polymer (see BAT 32 a.) where the synthetic rubber comes into contact with the atmosphere. Grp. applicability. Measurements do not apply to production processes only made up of a closed system.
BAT 31. Note
The samples are taken after lowering the VOC content in the polymer (see BAT 32 a.) where the synthetic rubber comes into contact with the atmosphere.
Applicability
Measurements do not apply to production processes only made up of a closed system.
BAT 32. Table 1.12 BAT-associated emission level (BAT-AEL) for total emissions to air of VOC from the production of synthetic rubbers expressed as specific emission load
In order to reduce emissions to air of organic compounds, BAT is to use one or a combination of the techniques given below. Technique Description a. Lowering the VOC content in the polymer The VOC content in the polymer is lowered by using stripping or devolatilisation extrusion (see Section 1.4.3). b. Collection and treatment of process off-gases Process off-gases are collected and sent to recovery (see BAT 9 and BAT 10) and/or abatement (see BAT 11). Substance/Parameter Unit BAT-AEL (Yearly average) TVOC g C per kg of synthetic rubber produced 0,2-4,2 The associated monitoring is given in BAT 8, BAT 20, BAT 22 and BAT 31. The monitoring of TVOC emissions to air includes all emissions from the following process steps, where the emissions are identified as relevant in the inventory given in BAT 2: storage of raw materials, polymerisation, recovery of materials and abatement techniques, finishing of the polymer (e.g. extrusion, drying, blending) as well as the transfer, handling and storage of synthetic rubbers.
1.2.4. BAT conclusions for the production of viscose using CS2 Grp. 33. BAT is to monitor channelled emissions to air with at least the frequency given below and in accordance with EN standards. If EN standards are not available, BAT is to use ISO, national or other international standards that ensure the provision of data of an equivalent scientific quality. Substance Emission points Standard(s) Minimum monitoring frequency Monitoring associated with Carbon disulphide (CS2) Any stack with a mass flow of ≥ 1 kg/h Generic EN standards Continuous BAT 35 Any stack with a mass flow of < 1 kg/h No EN standard available Once every year Hydrogen sulphide (H2S) Any stack with a mass flow of ≥ 50 g/h Generic EN standards Continuous Any stack with a mass flow of < 50 g/h No EN standard available Once every year Grp. 34. In order to increase resource efficiency and to reduce the mass flow of CS2 and H2S sent to the final waste gas treatment, BAT is to recover CS2 by using technique a. and/or technique b. or a combination of technique c. with technique(s) a. and/or b., given below and to reuse the CS2, or, alternatively, to use technique d. Technique Main substance targeted Description Applicability a. Absorption (regenerative) H2S See Section 1.4.1. Generally applicable for the production of casing. For other products, applicability may be restricted where the energy demand is excessive due to high waste gas volume flows (above e.g. 120000 Nm3/h) or low H2S concentration in the waste gas (below e.g. 0,5 g/Nm3). b. Adsorption (regenerative) H2S, CS2 See Section 1.4.1. Applicability may be restricted where the energy demand for recovery is excessive if the concentration of CS2 in the waste gas is below e.g. 5 g/Nm3. c. Condensation H2S, CS2 See Section 1.4.1. d. Production of sulphuric acid H2S, CS2 Process off-gases containing CS2 and H2S are used to produce sulphuric acid. Applicability may be restricted if the concentration of CS2 and/or H2S in the waste gas is below 5 g/Nm3. Grp_35_table. 113. In order to reduce channelled emissions to air of CS2 and H2S, BAT is to use one or a combination of the techniques given below. Technique Main substance targeted Description Applicability a. Absorption H2S See Section 1.4.1. Generally applicable. b. Bioprocesses CS2, H2S See Section 1.4.1. Applicability may be restricted where the energy demand is excessive due to high waste gas volume flows (e.g. above 60000 Nm3/h) or high CS2 concentration in the waste gas (e.g. above 1 000 mg/Nm3) or too low H2S concentration. c. Thermal oxidation CS2, H2S See Section 1.4.1. Applicability of recuperative and regenerative thermal oxidation to existing plants may be restricted by design and/or operational constraints. Applicability may be restricted where the energy demand is excessive due to the low concentration of the compound(s) concerned in the process off-gases. Substance BAT-AEL (mg/Nm3) (Daily average or average over the sampling period) CS2 5-400 H2S 1-10 The associated monitoring is given in BAT 33. Parameter Process Unit BAT-AEL (Yearly average) Sum of H2S and CS2 (expressed as Total S) Production of staple fibres g Total S per kg of product 6-9 Casing 120-250 The associated monitoring is given in BAT 33.
1.2.4.
BAT 33. BAT is to monitor channelled emissions to air with at least the frequency given below and in accordance with EN standards. If EN standards are not available, BAT is to use ISO, national or other international standards that ensure the provision of data of an equivalent scientific quality. Substance Emission points Standard(s) Minimum monitoring frequency Monitoring associated with Carbon disulphide (CS2) Any stack with a mass flow of ≥ 1 kg/h Generic EN standards Continuous BAT 35 Any stack with a mass flow of < 1 kg/h No EN standard available Once every year Hydrogen sulphide (H2S) Any stack with a mass flow of ≥ 50 g/h Generic EN standards Continuous Any stack with a mass flow of < 50 g/h No EN standard available Once every year
BAT 34. In order to increase resource efficiency and to reduce the mass flow of CS2 and H2S sent to the final waste gas treatment, BAT is to recover CS2 by using technique a. and/or technique b. or a combination of technique c. with technique(s) a. and/or b., given below and to reuse the CS2, or, alternatively, to use technique d. Technique Main substance targeted Description Applicability a. Absorption (regenerative) H2S See Section 1.4.1. Generally applicable for the production of casing. For other products, applicability may be restricted where the energy demand is excessive due to high waste gas volume flows (above e.g. 120000 Nm3/h) or low H2S concentration in the waste gas (below e.g. 0,5 g/Nm3). b. Adsorption (regenerative) H2S, CS2 See Section 1.4.1. Applicability may be restricted where the energy demand for recovery is excessive if the concentration of CS2 in the waste gas is below e.g. 5 g/Nm3. c. Condensation H2S, CS2 See Section 1.4.1. d. Production of sulphuric acid H2S, CS2 Process off-gases containing CS2 and H2S are used to produce sulphuric acid. Applicability may be restricted if the concentration of CS2 and/or H2S in the waste gas is below 5 g/Nm3.
BAT 35. Table 1.13 Table 1.14 BAT-associated emission levels (BAT-AELs) for channelled emissions to air of CS2 and H2S from the production of viscose using CS2 BAT-associated emission levels (BAT-AELs) for emissions to air of H2S and CS2 from the production of staple fibres and casing expressed as specific emission loads
In order to reduce channelled emissions to air of CS2 and H2S, BAT is to use one or a combination of the techniques given below. Technique Main substance targeted Description Applicability a. Absorption H2S See Section 1.4.1. Generally applicable. b. Bioprocesses CS2, H2S See Section 1.4.1. Applicability may be restricted where the energy demand is excessive due to high waste gas volume flows (e.g. above 60000 Nm3/h) or high CS2 concentration in the waste gas (e.g. above 1 000 mg/Nm3) or too low H2S concentration. c. Thermal oxidation CS2, H2S See Section 1.4.1. Applicability of recuperative and regenerative thermal oxidation to existing plants may be restricted by design and/or operational constraints. Applicability may be restricted where the energy demand is excessive due to the low concentration of the compound(s) concerned in the process off-gases. Substance BAT-AEL (mg/Nm3) (Daily average or average over the sampling period) CS2 5-400 H2S 1-10 The associated monitoring is given in BAT 33. Parameter Process Unit BAT-AEL (Yearly average) Sum of H2S and CS2 (expressed as Total S) Production of staple fibres g Total S per kg of product 6-9 Casing 120-250 The associated monitoring is given in BAT 33.
1.3. Process furnaces/heaters The BAT conclusions presented in this section apply when process furnaces/heaters with a total rated thermal input equal to or greater than 1 MW are used in the production processes included in the scope of these BAT conclusions. They apply in addition to the general BAT conclusions given in Section 1.1. Where the waste gases of two or more separate process furnaces/heaters are, or could, in the judgement of the competent authority, be discharged through a common stack, the capacities of all individual furnaces/heaters shall be added together for the purpose of calculating the total rated thermal input. Grp_36_table. 115. In order to prevent or, where that is not practicable, to reduce channelled emissions to air of CO, dust, NOX and SOX, BAT is to use technique c. and one or a combination of the other techniques given below. Technique Description Main inorganic compounds targeted Applicability Primary techniques a. Choice of fuel See Section 1.4.1. This includes switching from liquid to gaseous fuels, taking into account the overall hydrocarbon balance. NOX, SOX, dust The switch from liquid to gaseous fuels may be restricted by the design of the burners in the case of existing process furnaces/heaters. b. Low-NOX burner See Section 1.4.1. NOX For existing process furnaces/heaters, the applicability may be restricted by their design. c. Optimised combustion See Section 1.4.1. CO, NOX Generally applicable. Secondary techniques d. Absorption See Section 1.4.1. SOX, dust Applicability may be restricted for existing process furnaces/heaters by space availability. e. Fabric filter or absolute filter See Section 1.4.1. Dust Not applicable when only combusting gaseous fuels. f. Selective catalytic reduction (SCR) See Section 1.4.1. NOX Applicability to existing process furnaces/heaters may be restricted by space availability. g. Selective non-catalytic reduction (SNCR) See Section 1.4.1. NOX Applicability to existing process furnaces/heaters may be restricted by the temperature window (800-1100 °C) and the residence time needed for the reaction. Parameter BAT-AEL (mg/Nm3) (Daily average or average over the sampling period) Nitrogen oxides (NOX) 30-150 Carbon monoxide (CO) No BAT-AEL The associated monitoring is given in BAT 8.
1.3.
BAT 36. Table 1.15 BAT-associated emission level (BAT-AEL) for channelled NOX emissions to air and indicative emission level for channelled CO emissions to air from process furnaces/heaters
In order to prevent or, where that is not practicable, to reduce channelled emissions to air of CO, dust, NOX and SOX, BAT is to use technique c. and one or a combination of the other techniques given below. Technique Description Main inorganic compounds targeted Applicability Primary techniques a. Choice of fuel See Section 1.4.1. This includes switching from liquid to gaseous fuels, taking into account the overall hydrocarbon balance. NOX, SOX, dust The switch from liquid to gaseous fuels may be restricted by the design of the burners in the case of existing process furnaces/heaters. b. Low-NOX burner See Section 1.4.1. NOX For existing process furnaces/heaters, the applicability may be restricted by their design. c. Optimised combustion See Section 1.4.1. CO, NOX Generally applicable. Secondary techniques d. Absorption See Section 1.4.1. SOX, dust Applicability may be restricted for existing process furnaces/heaters by space availability. e. Fabric filter or absolute filter See Section 1.4.1. Dust Not applicable when only combusting gaseous fuels. f. Selective catalytic reduction (SCR) See Section 1.4.1. NOX Applicability to existing process furnaces/heaters may be restricted by space availability. g. Selective non-catalytic reduction (SNCR) See Section 1.4.1. NOX Applicability to existing process furnaces/heaters may be restricted by the temperature window (800-1100 °C) and the residence time needed for the reaction. Parameter BAT-AEL (mg/Nm3) (Daily average or average over the sampling period) Nitrogen oxides (NOX) 30-150 Carbon monoxide (CO) No BAT-AEL The associated monitoring is given in BAT 8.
1.4. Description of techniques (1) Biofiltration: the waste gas stream is passed through a bed of organic material (such as peat, heather, compost, root wood, tree bark, peat, compost, softwood and different kinds of combinations) or some inert material (such as clay, activated carbon, and polyurethane), where it is biologically oxidised by naturally occurring microorganisms into carbon dioxide, water, inorganic salts and biomass. (2) Bioscrubbing: the removal of the pollutant compounds from a waste gas stream using a combination of wet scrubbing (absorption) and biodegradation under aerobic conditions. The scrubbing water contains a population of microorganisms suitable to oxidise biodegradable gaseous compounds. The absorbed pollutants are degraded in aerated sludge tanks. (3) Biotrickling: the removal of the pollutant compounds from a waste gas stream in a biological trickle-bed reactor. The pollutants are absorbed by the water phase and transported to the biofilm, where the biological transformation takes place. (4) Straight thermal oxidation: thermal oxidation without energy recovery from the combustion. (5) Recuperative thermal oxidation: thermal oxidation using the heat of the waste gases by indirect heat transfer. (6) Regenerative thermal oxidation: thermal oxidation where the incoming waste gas stream is heated when passing through a ceramic-packed bed before entering the combustion chamber. The purified hot gases exit this chamber by passing through one (or more) ceramic-packed bed(s) (cooled by an incoming waste gas stream in an earlier combustion cycle). This reheated packed bed then begins a new combustion cycle by preheating a new incoming waste gas stream. Grp. 141. Techniques to reduce channelled emissions to air Technique Description Absorption The removal of gaseous or particulate pollutants from a process off-gas or waste gas stream via mass transfer to a suitable liquid, often water or an aqueous solution. It may involve a chemical reaction (e.g. in an acid or alkaline scrubber). In the case of regenerative absorption, the compounds may be recovered from the liquid. Adsorption The removal of pollutants from a process off-gas or waste gas stream by retention on a solid surface (activated carbon is typically used as the adsorbent). Adsorption may be regenerative or non-regenerative. In non-regenerative adsorption, the spent adsorbent is not regenerated but disposed of. In the case of regenerative adsorption, the adsorbate is subsequently desorbed, e.g. with steam (often on site), for reuse or disposal and the adsorbent is reused. For continuous operation, typically more than two adsorbers are operated in parallel, one of them in desorption mode. Bioprocesses Bioprocesses include the following: Choice of fuel The use of fuel (including support/auxiliary fuel) with a low content of potential pollution-generating compounds (e.g. low sulphur, ash, nitrogen, fluorine or chlorine content in the fuel). Condensation The removal of vapours of organic and inorganic compounds from a process off-gas or waste gas stream by reducing its temperature below its dew point so that the vapours liquefy. Depending on the operating temperature range required, different cooling media are used, e.g. water or brine. In cryogenic condensation, liquid nitrogen is used as a cooling medium. Cyclone Equipment for the removal of dust from a process off-gas or waste gas stream based on imparting centrifugal forces, usually within a conical chamber. Electrostatic precipitator An electrostatic precipitator (ESP) is a particulate control device that uses electrical forces to move particles entrained within a waste gas stream onto collector plates. The entrained particles are given an electrical charge when they pass through a corona where gaseous ions flow. Electrodes in the centre of the flow lane are maintained at a high voltage and generate the electrical field that forces the particles to the collector walls. The pulsating DC voltage required is in the range of 20-100 kV. Absolute filter Absolute filters, also referred to as high-efficiency particle air (HEPA) filters or ultra-low penetration air (ULPA) filters, are constructed from glass cloth or fabrics of synthetic fibres through which gases are passed to remove particles. Absolute filters show higher efficiencies than fabric filters. The classification of HEPA and ULPA filters according to their performance is given in EN 1822-1. High-efficiency air filter (HEAF) A flat-bed filter in which aerosols combine into droplets. Highly viscous droplets remain on the filter fabric which contains the residues to be disposed of and separated into droplets, aerosols and dust. HEAFs are particularly suitable for treating highly viscous droplets. Fabric filter Fabric filters, often referred to as bag filters, are constructed from porous woven or felted fabric through which gases are passed to remove particles. The use of a fabric filter requires the selection of a fabric suitable for the characteristics of the waste gas and the maximum operating temperature. Low-NOX burner The technique (including ultra-low-NOX burner) is based on the principles of reducing peak flame temperatures. The air/fuel mixing reduces the availability of oxygen and reduces the peak flame temperature, thus retarding the conversion of fuel-bound nitrogen to NOX and the formation of thermal NOX, while maintaining high combustion efficiency. The design of ultra-low-NOX burners includes (air/)fuel staging and exhaust/flue-gas recirculation. Optimised combustion Good design of the combustion chambers, burners and associated equipment/devices is combined with optimisation of combustion conditions (e.g. the temperature and residence time in the combustion zone, efficient mixing of the fuel and combustion air) and the regular planned maintenance of the combustion system according to suppliers’ recommendations. Combustion conditions control is based on the continuous monitoring and automated control of appropriate combustion parameters (e.g. O2, CO, fuel to air ratio, and unburnt substances). Optimisation of catalytic or thermal oxidation Optimisation of design and operation of catalytic or thermal oxidation to promote the oxidation of organic compounds including PCDD/F present in the waste gases, to prevent PCDD/F and the (re)formation of their precursors, as well as to reduce the generation of pollutants such as NOX and CO. Catalytic oxidation Abatement technique which oxidises combustible compounds in a waste gas stream with air or oxygen in a catalyst bed. The catalyst enables oxidation at lower temperatures and in smaller equipment compared to thermal oxidation. The typical oxidation temperature is between 200 °C and 600 °C. For process off-gases with low VOC concentrations (e.g. < 1 g/Nm3), pre-concentration steps may be applied using adsorption (rotor or fixed bed, with activated carbon or zeolites). VOCs adsorbed in the concentrator are desorbed by using heated ambient air or heated waste gas, and the resulting volume flow with higher VOC concentration is directed to the oxidiser. Molecular sieves (smoothers), typically composed of zeolites, may be used before the concentrators or the oxidiser to level down high variations of VOC concentrations in the process off-gases. Thermal oxidation Abatement technique which oxidises combustible compounds in a waste gas stream by heating it with air or oxygen to above its auto-ignition point in a combustion chamber and maintaining it at a high temperature long enough to complete its combustion to carbon dioxide and water. The typical combustion temperature is between 800 °C and 1000 °C. Several types of thermal oxidation are operated: For process off-gases with low VOC concentrations (e.g. < 1 g/Nm3), pre-concentration steps may be applied using adsorption (rotor or fixed bed, with activated carbon or zeolites). VOCs adsorbed in the concentrator are desorbed by using heated ambient air or heated waste gas, and the resulting volume flow with higher VOC concentration is directed to the oxidiser. Molecular sieves (smoothers), typically composed of zeolites, may be used before the concentrators or the oxidiser to level down high variations of VOC concentrations in the process off-gases. Selective catalytic reduction (SCR) Selective reduction of nitrogen oxides with ammonia or urea in the presence of a catalyst. The technique is based on the reduction of NOX to nitrogen in a catalytic bed by reaction with ammonia at an optimum operating temperature that is typically around 200– 450 °C. In general, ammonia is injected as an aqueous solution; the ammonia source can also be anhydrous ammonia or a urea solution. Several layers of catalyst may be applied. A higher NOX reduction is achieved with the use of a larger catalyst surface, installed as one or more layers. In-duct or slip SCR combines SNCR with downstream SCR which reduces the ammonia slip from SNCR. Selective non-catalytic reduction (SNCR) Selective reduction of nitrogen oxides to nitrogen with ammonia or urea at high temperatures and without catalyst. The operating temperature window is maintained between 800 °C and 1000 °C for optimal reaction. Grp. 142. Techniques to monitor diffuse emissions to air Technique Description Differential absorption LIDAR (DIAL) A laser-based technique using differential absorption LIDAR (light detection and ranging), which is the optical analogue of radio-wave-based RADAR. The technique relies on the back-scattering of laser beam pulses by atmospheric aerosols, and the analysis of the spectral properties of the returned light collected with a telescope. Emission factor Emission factors are numbers that can be multiplied by an activity rate (e.g. the production output), in order to estimate the emissions from the installation. Emission factors are generally derived through the testing of a population of similar process equipment or process steps. This information can be used to relate the quantity of material emitted to some general measure of the scale of activity. In the absence of other information, default emission factors (e.g. literature values) can be used to provide an estimate of the emissions. Emission factors are usually expressed as the mass of a substance emitted divided by the throughput of the process emitting the substance. Leak Detection and Repair (LDAR) programme A structured approach to reduce fugitive VOC emissions by detection and subsequent repair or replacement of leaking components. The LDAR programme consists of one or more campaigns. A campaign is usually conducted over 1 year, where a certain percentage of the pieces of equipment is monitored. Optical gas imaging (OGI) methods Optical gas imaging uses small lightweight hand-held or fixed cameras which enable the visualisation of gas leaks in real time, so that they appear as smoke on a video recorder together with the image of the equipment concerned, to easily and rapidly locate significant VOC leaks. Active systems produce an image with a back-scattered infrared laser light reflected on the equipment and its surroundings. Passive systems are based on the natural infrared radiation of the equipment and its surroundings. Solar occultation flux (SOF) The technique is based on the recording and spectrometric Fourier Transform analysis of a broadband infrared or ultraviolet/visible sunlight spectrum along a given geographical itinerary, crossing the wind direction and cutting through VOC plumes. Grp. 143. Techniques to reduce diffuse emissions Technique Description Devolatilisation extrusion When the concentrated rubber solution is further processed by extrusion, the solvent vapours (commonly cyclohexane, hexane, heptane, toluene, cyclopentane, isopentane or mixtures thereof) coming from the vent hole of the extruder are compressed and sent to recovery. Stripping VOCs contained in the polymer are transferred to the gaseous phase (e.g. by using steam). The removal efficiency may be optimised by a suitable combination of temperature, pressure and residence time and by maximising the ratio of free polymer surface to total polymer volume. Vapour balancing The vapour from a piece of receiving equipment (e.g. a tank) that is displaced during the transfer of a liquid and is returned to the delivery equipment from which the liquid is delivered.
1.4.
1.4.1. Techniques to reduce channelled emissions to air Technique Description Absorption The removal of gaseous or particulate pollutants from a process off-gas or waste gas stream via mass transfer to a suitable liquid, often water or an aqueous solution. It may involve a chemical reaction (e.g. in an acid or alkaline scrubber). In the case of regenerative absorption, the compounds may be recovered from the liquid. Adsorption The removal of pollutants from a process off-gas or waste gas stream by retention on a solid surface (activated carbon is typically used as the adsorbent). Adsorption may be regenerative or non-regenerative. In non-regenerative adsorption, the spent adsorbent is not regenerated but disposed of. In the case of regenerative adsorption, the adsorbate is subsequently desorbed, e.g. with steam (often on site), for reuse or disposal and the adsorbent is reused. For continuous operation, typically more than two adsorbers are operated in parallel, one of them in desorption mode. Bioprocesses Bioprocesses include the following: Choice of fuel The use of fuel (including support/auxiliary fuel) with a low content of potential pollution-generating compounds (e.g. low sulphur, ash, nitrogen, fluorine or chlorine content in the fuel). Condensation The removal of vapours of organic and inorganic compounds from a process off-gas or waste gas stream by reducing its temperature below its dew point so that the vapours liquefy. Depending on the operating temperature range required, different cooling media are used, e.g. water or brine. In cryogenic condensation, liquid nitrogen is used as a cooling medium. Cyclone Equipment for the removal of dust from a process off-gas or waste gas stream based on imparting centrifugal forces, usually within a conical chamber. Electrostatic precipitator An electrostatic precipitator (ESP) is a particulate control device that uses electrical forces to move particles entrained within a waste gas stream onto collector plates. The entrained particles are given an electrical charge when they pass through a corona where gaseous ions flow. Electrodes in the centre of the flow lane are maintained at a high voltage and generate the electrical field that forces the particles to the collector walls. The pulsating DC voltage required is in the range of 20-100 kV. Absolute filter Absolute filters, also referred to as high-efficiency particle air (HEPA) filters or ultra-low penetration air (ULPA) filters, are constructed from glass cloth or fabrics of synthetic fibres through which gases are passed to remove particles. Absolute filters show higher efficiencies than fabric filters. The classification of HEPA and ULPA filters according to their performance is given in EN 1822-1. High-efficiency air filter (HEAF) A flat-bed filter in which aerosols combine into droplets. Highly viscous droplets remain on the filter fabric which contains the residues to be disposed of and separated into droplets, aerosols and dust. HEAFs are particularly suitable for treating highly viscous droplets. Fabric filter Fabric filters, often referred to as bag filters, are constructed from porous woven or felted fabric through which gases are passed to remove particles. The use of a fabric filter requires the selection of a fabric suitable for the characteristics of the waste gas and the maximum operating temperature. Low-NOX burner The technique (including ultra-low-NOX burner) is based on the principles of reducing peak flame temperatures. The air/fuel mixing reduces the availability of oxygen and reduces the peak flame temperature, thus retarding the conversion of fuel-bound nitrogen to NOX and the formation of thermal NOX, while maintaining high combustion efficiency. The design of ultra-low-NOX burners includes (air/)fuel staging and exhaust/flue-gas recirculation. Optimised combustion Good design of the combustion chambers, burners and associated equipment/devices is combined with optimisation of combustion conditions (e.g. the temperature and residence time in the combustion zone, efficient mixing of the fuel and combustion air) and the regular planned maintenance of the combustion system according to suppliers’ recommendations. Combustion conditions control is based on the continuous monitoring and automated control of appropriate combustion parameters (e.g. O2, CO, fuel to air ratio, and unburnt substances). Optimisation of catalytic or thermal oxidation Optimisation of design and operation of catalytic or thermal oxidation to promote the oxidation of organic compounds including PCDD/F present in the waste gases, to prevent PCDD/F and the (re)formation of their precursors, as well as to reduce the generation of pollutants such as NOX and CO. Catalytic oxidation Abatement technique which oxidises combustible compounds in a waste gas stream with air or oxygen in a catalyst bed. The catalyst enables oxidation at lower temperatures and in smaller equipment compared to thermal oxidation. The typical oxidation temperature is between 200 °C and 600 °C. For process off-gases with low VOC concentrations (e.g. < 1 g/Nm3), pre-concentration steps may be applied using adsorption (rotor or fixed bed, with activated carbon or zeolites). VOCs adsorbed in the concentrator are desorbed by using heated ambient air or heated waste gas, and the resulting volume flow with higher VOC concentration is directed to the oxidiser. Molecular sieves (smoothers), typically composed of zeolites, may be used before the concentrators or the oxidiser to level down high variations of VOC concentrations in the process off-gases. Thermal oxidation Abatement technique which oxidises combustible compounds in a waste gas stream by heating it with air or oxygen to above its auto-ignition point in a combustion chamber and maintaining it at a high temperature long enough to complete its combustion to carbon dioxide and water. The typical combustion temperature is between 800 °C and 1000 °C. Several types of thermal oxidation are operated: For process off-gases with low VOC concentrations (e.g. < 1 g/Nm3), pre-concentration steps may be applied using adsorption (rotor or fixed bed, with activated carbon or zeolites). VOCs adsorbed in the concentrator are desorbed by using heated ambient air or heated waste gas, and the resulting volume flow with higher VOC concentration is directed to the oxidiser. Molecular sieves (smoothers), typically composed of zeolites, may be used before the concentrators or the oxidiser to level down high variations of VOC concentrations in the process off-gases. Selective catalytic reduction (SCR) Selective reduction of nitrogen oxides with ammonia or urea in the presence of a catalyst. The technique is based on the reduction of NOX to nitrogen in a catalytic bed by reaction with ammonia at an optimum operating temperature that is typically around 200– 450 °C. In general, ammonia is injected as an aqueous solution; the ammonia source can also be anhydrous ammonia or a urea solution. Several layers of catalyst may be applied. A higher NOX reduction is achieved with the use of a larger catalyst surface, installed as one or more layers. In-duct or slip SCR combines SNCR with downstream SCR which reduces the ammonia slip from SNCR. Selective non-catalytic reduction (SNCR) Selective reduction of nitrogen oxides to nitrogen with ammonia or urea at high temperatures and without catalyst. The operating temperature window is maintained between 800 °C and 1000 °C for optimal reaction. (1) Biofiltration: the waste gas stream is passed through a bed of organic material (such as peat, heather, compost, root wood, tree bark, peat, compost, softwood and different kinds of combinations) or some inert material (such as clay, activated carbon, and polyurethane), where it is biologically oxidised by naturally occurring microorganisms into carbon dioxide, water, inorganic salts and biomass. (2) Bioscrubbing: the removal of the pollutant compounds from a waste gas stream using a combination of wet scrubbing (absorption) and biodegradation under aerobic conditions. The scrubbing water contains a population of microorganisms suitable to oxidise biodegradable gaseous compounds. The absorbed pollutants are degraded in aerated sludge tanks. (3) Biotrickling: the removal of the pollutant compounds from a waste gas stream in a biological trickle-bed reactor. The pollutants are absorbed by the water phase and transported to the biofilm, where the biological transformation takes place. (4) Straight thermal oxidation: thermal oxidation without energy recovery from the combustion. (5) Recuperative thermal oxidation: thermal oxidation using the heat of the waste gases by indirect heat transfer. (6) Regenerative thermal oxidation: thermal oxidation where the incoming waste gas stream is heated when passing through a ceramic-packed bed before entering the combustion chamber. The purified hot gases exit this chamber by passing through one (or more) ceramic-packed bed(s) (cooled by an incoming waste gas stream in an earlier combustion cycle). This reheated packed bed then begins a new combustion cycle by preheating a new incoming waste gas stream.
Biofiltration: the waste gas stream is passed through a bed of organic material (such as peat, heather, compost, root wood, tree bark, peat, compost, softwood and different kinds of combinations) or some inert material (such as clay, activated carbon, and polyurethane), where it is biologically oxidised by naturally occurring microorganisms into carbon dioxide, water, inorganic salts and biomass.
Bioscrubbing: the removal of the pollutant compounds from a waste gas stream using a combination of wet scrubbing (absorption) and biodegradation under aerobic conditions. The scrubbing water contains a population of microorganisms suitable to oxidise biodegradable gaseous compounds. The absorbed pollutants are degraded in aerated sludge tanks.
Biotrickling: the removal of the pollutant compounds from a waste gas stream in a biological trickle-bed reactor. The pollutants are absorbed by the water phase and transported to the biofilm, where the biological transformation takes place.
Straight thermal oxidation: thermal oxidation without energy recovery from the combustion.
Recuperative thermal oxidation: thermal oxidation using the heat of the waste gases by indirect heat transfer.
Regenerative thermal oxidation: thermal oxidation where the incoming waste gas stream is heated when passing through a ceramic-packed bed before entering the combustion chamber. The purified hot gases exit this chamber by passing through one (or more) ceramic-packed bed(s) (cooled by an incoming waste gas stream in an earlier combustion cycle). This reheated packed bed then begins a new combustion cycle by preheating a new incoming waste gas stream.
1.4.2. Techniques to monitor diffuse emissions to air Technique Description Differential absorption LIDAR (DIAL) A laser-based technique using differential absorption LIDAR (light detection and ranging), which is the optical analogue of radio-wave-based RADAR. The technique relies on the back-scattering of laser beam pulses by atmospheric aerosols, and the analysis of the spectral properties of the returned light collected with a telescope. Emission factor Emission factors are numbers that can be multiplied by an activity rate (e.g. the production output), in order to estimate the emissions from the installation. Emission factors are generally derived through the testing of a population of similar process equipment or process steps. This information can be used to relate the quantity of material emitted to some general measure of the scale of activity. In the absence of other information, default emission factors (e.g. literature values) can be used to provide an estimate of the emissions. Emission factors are usually expressed as the mass of a substance emitted divided by the throughput of the process emitting the substance. Leak Detection and Repair (LDAR) programme A structured approach to reduce fugitive VOC emissions by detection and subsequent repair or replacement of leaking components. The LDAR programme consists of one or more campaigns. A campaign is usually conducted over 1 year, where a certain percentage of the pieces of equipment is monitored. Optical gas imaging (OGI) methods Optical gas imaging uses small lightweight hand-held or fixed cameras which enable the visualisation of gas leaks in real time, so that they appear as smoke on a video recorder together with the image of the equipment concerned, to easily and rapidly locate significant VOC leaks. Active systems produce an image with a back-scattered infrared laser light reflected on the equipment and its surroundings. Passive systems are based on the natural infrared radiation of the equipment and its surroundings. Solar occultation flux (SOF) The technique is based on the recording and spectrometric Fourier Transform analysis of a broadband infrared or ultraviolet/visible sunlight spectrum along a given geographical itinerary, crossing the wind direction and cutting through VOC plumes.
1.4.3. Techniques to reduce diffuse emissions Technique Description Devolatilisation extrusion When the concentrated rubber solution is further processed by extrusion, the solvent vapours (commonly cyclohexane, hexane, heptane, toluene, cyclopentane, isopentane or mixtures thereof) coming from the vent hole of the extruder are compressed and sent to recovery. Stripping VOCs contained in the polymer are transferred to the gaseous phase (e.g. by using steam). The removal efficiency may be optimised by a suitable combination of temperature, pressure and residence time and by maximising the ratio of free polymer surface to total polymer volume. Vapour balancing The vapour from a piece of receiving equipment (e.g. a tank) that is displaced during the transfer of a liquid and is returned to the delivery equipment from which the liquid is delivered.