Commission Decision of 21 December 2006 establishing harmonised efficiency reference values for separate production of electricity and heat in application of Directive 2004/8/EC of the European Parliament and of the Council (notified under document number C(2006) 6817) (Text with EEA relevance) (2007/74/EC)
Grade B
mapped from publisher markup. A grade says how a document's structure was obtained, not how reliable the law is.
Address https://gelex.eu/eli/EU/decision/2007/74@2006-12-21/en
Contents
- Preamble
- Article 1 Establishment of the harmonised efficiency reference values
- Article 2 Correction factors for the harmonised efficiency reference values for separate production of electricity
- Article 3 Application of the harmonised efficiency reference values
- Article 4 Retrofitting of a cogeneration unit
- Article 5 Fuel mix
- Article 6 Addressees
- ANNEX
- ANNEX I Harmonised efficiency reference values for separate production of electricity (referred to in Article 1)
- ANNEX II Harmonised efficiency reference values for separate production of heat (referred to in Article 1)
- ANNEX III Correction factors relating to the average climatic situation and method for establishing climate zones for the application of the harmonised efficiency reference values for separate production of electricity (referred to in Article 2(1))
- ANNEX IV Correction factors for avoided grid losses for the application of the harmonised efficiency reference values for separate production of electricity (referred to in Article 2(2))
THE COMMISSION OF THE EUROPEAN COMMUNITIES,
Having regard to the Treaty establishing the European Community,
Having regard to Directive 2004/8/EC of the European Parliament and of the Council on the promotion of cogeneration based on a useful heat demand in the internal energy market and amending Directive 92/42/EC, and in particular Article 4(1) thereof,
Whereas:
(1) Pursuant to Article 4 of Directive 2004/8/EC the Commission is to establish harmonised efficiency reference values for separate production of electricity and heat consisting of a matrix of values differentiated by relevant factors, including year of construction and types of fuel.
(2) The Commission has completed a well-documented analysis in accordance with Article 4(1) of Directive 2004/8/EC. Developments in the best available and economically justifiable technology which were observed during the period covered by this analysis indicate that for the harmonised efficiency reference values for separate production of electricity, a distinction should be drawn relating to the year of construction of a cogeneration unit. Furthermore, correction factors relating to the climatic situation should be applied to these reference values because the thermodynamics of generating electricity from fuel depend on the ambient temperature. In addition correction factors for avoided grid losses should be applied to these reference values to take account of the energy savings obtained when grid use is limited due to decentralised production.
(3) By contrast, the analysis showed that concerning the harmonised efficiency reference values for separate production of heat a distinction relating to the year of construction was not necessary as the net energy efficiency of boilers has hardly improved in the period covered by the analysis. No correction factors relating to the climatic situation were required because the thermodynamics of generating heat from fuel do not depend on the ambient temperature. In addition correction factors for heat grid losses are not required as heat is always used near the site of production.
(4) The harmonised efficiency reference values have been based on the principles mentioned in Annex III (f) of Directive 2004/8/EC.
(5) Stable conditions for investment in cogeneration and continued investor confidence are needed. In this perspective it is appropriate to maintain the same reference values for a cogeneration unit for a reasonably long period of ten years. However, taking into consideration the main aim of Directive 2004/8/EC to promote cogeneration in order to save primary energy, an incentive for retrofitting older cogeneration units should be given in order to improve their energy efficiency. For these reasons the efficiency reference values for electricity applicable to a cogeneration unit should become stricter from the eleventh year after the year of its construction.
(6) The measures provided for in this Decision are in accordance with the opinion of the Cogeneration Committee,
HAS ADOPTED THIS DECISION:
Article 1 Establishment of the harmonised efficiency reference values
The harmonised efficiency reference values for separate production of electricity and heat shall be as set out in Annex I and Annex II respectively.
Article 2 Correction factors for the harmonised efficiency reference values for separate production of electricity
1. Member States shall apply the correction factors set out in Annex III(a) in order to adapt the harmonised efficiency reference values set out in Annex I to the average climatic situation in each Member State. The correction factors for the average climatic situation shall not apply to fuel cell-based cogeneration technology. If on the territory of a Member State official meteorological data show differences in the annual ambient temperature of 5 oC or more, that Member State may, subject to notification to the Commission, use several climate zones for the purpose of the first subparagraph using the method set out in Annex III(b).
2. Member States shall apply the correction factors set out in Annex IV in order to adapt the harmonised efficiency reference values set out in Annex I to avoided grid losses. The correction factors for avoided grid losses shall not apply to wood fuels and biogas.
3. Where Member States apply both the correction factors set out in Annex III(a) and those set out in Annex IV, they shall apply Annex III(a) before applying Annex IV.
Article 3 Application of the harmonised efficiency reference values
1. Member States shall apply the harmonised efficiency reference values set out in Annex I relating to the year of construction of a cogeneration unit. These harmonised efficiency reference values shall apply for 10 years from the year of construction of a cogeneration unit.
2. From the eleventh year following the year of construction of a cogeneration unit, Member States shall apply the harmonised efficiency reference values which by virtue of paragraph 1 apply to a cogeneration unit of 10 years of age. These harmonised efficiency reference values shall apply for one year.
3. For the purpose of this Article the year of construction of a cogeneration unit shall mean the calendar year of the first electricity production.
Article 4 Retrofitting of a cogeneration unit
If an existing cogeneration unit is retrofitted and the investment cost for the retrofitting exceeds 50 % of the investment cost for a new comparable cogeneration unit, the calendar year of first electricity production of the retrofitted cogeneration unit shall be considered as its year of construction for the purpose of Article 3.
Article 5 Fuel mix
If the cogeneration unit is operated with a fuel mix the harmonised efficiency reference values for separate production shall be applied proportionally to the weighted mean of the energy input of the various fuels.
Article 6 Addressees
This Decision is addressed to the Member States.
Done at Brussels, 21 December 2006. For the Commission Andris Piebalgs Member of the Commission
ANNEX
ANNEX I Harmonised efficiency reference values for separate production of electricity (referred to in Article 1)
In the table below the harmonised efficiency reference values for separate production of electricity are based on net calorific value and standard ISO conditions (15 oC ambient temperature, 1,013 bar, 60 % relative humidity). % Year of construction: Type of fuel: 1996 and before 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006-2011 Solid Hard coal/coke 39,7 40,5 41,2 41,8 42,3 42,7 43,1 43,5 43,8 44,0 44,2 Lignite/lignite briquettes 37,3 38,1 38,8 39,4 39,9 40,3 40,7 41,1 41,4 41,6 41,8 Peat/peat briquettes 36,5 36,9 37,2 37,5 37,8 38,1 38,4 38,6 38,8 38,9 39,0 Wood fuels 25,0 26,3 27,5 28,5 29,6 30,4 31,1 31,7 32,2 32,6 33,0 Agricultural biomass 20,0 21,0 21,6 22,1 22,6 23,1 23,5 24,0 24,4 24,7 25,0 Biodegradable (municipal) waste 20,0 21,0 21,6 22,1 22,6 23,1 23,5 24,0 24,4 24,7 25,0 Non-renewable (municipal and industrial) waste 20,0 21,0 21,6 22,1 22,6 23,1 23,5 24,0 24,4 24,7 25,0 Oil shale 38,9 38,9 38,9 38,9 38,9 38,9 38,9 38,9 38,9 38,9 39,0 Liquid Oil (gas oil + residual fuel oil), LPG 39,7 40,5 41,2 41,8 42,3 42,7 43,1 43,5 43,8 44,0 44,2 Biofuels 39,7 40,5 41,2 41,8 42,3 42,7 43,1 43,5 43,8 44,0 44,2 Biodegradable waste 20,0 21,0 21,6 22,1 22,6 23,1 23,5 24,0 24,4 24,7 25,0 Non-renewable waste 20,0 21,0 21,6 22,1 22,6 23,1 23,5 24,0 24,4 24,7 25,0 Gaseous Natural gas 50,0 50,4 50,8 51,1 51,4 51,7 51,9 52,1 52,3 52,4 52,5 Refinery gas/hydrogen 39,7 40,5 41,2 41,8 42,3 42,7 43,1 43,5 43,8 44,0 44,2 Biogas 36,7 37,5 38,3 39,0 39,6 40,1 40,6 41,0 41,4 41,7 42,0 Coke oven gas, blast furnace gas, other waste gases, recovered waste heat 35 35 35 35 35 35 35 35 35 35 35
ANNEX II Harmonised efficiency reference values for separate production of heat (referred to in Article 1)
In the table below the harmonised efficiency reference values for separate production of heat are based on net calorific value and standard ISO conditions (15 oC ambient temperature, 1,013 bar, 60 % relative humidity). % Type of fuel: Steam /hot water Direct use of exhaust gases Solid Hard coal/coke 88 80 Lignite/lignite briquettes 86 78 Peat/peat briquettes 86 78 Wood fuels 86 78 Agricultural biomass 80 72 Biodegradable (municipal) waste 80 72 Non-renewable (municipal and industrial) waste 80 72 Oil shale 86 78 Liquid Oil (gas oil + residual fuel oil), LPG 89 81 Biofuels 89 81 Biodegradable waste 80 72 Non-renewable waste 80 72 Gaseous Natural gas 90 82 Refinery gas/hydrogen 89 81 Biogas 70 62 Coke oven gas, blast furnace gas + other waste gases 80 72
ANNEX III Correction factors relating to the average climatic situation and method for establishing climate zones for the application of the harmonised efficiency reference values for separate production of electricity (referred to in Article 2(1))
(a) Correction factors relating to the average climatic situation Ambient temperature correction is based on the difference between the annual average temperature in a Member State and standard ISO conditions (15 oC). The correction will be as follows: 0,1 %-point efficiency loss for every degree above 15 oC; 0,1 %-point efficiency gain for every degree under 15 oC. Example: When the average annual temperature in a Member State is 10 oC, the reference value of a cogeneration unit in that Member State has to be increased with 0,5 %-points.
(b) Method for establishing climate zones The borders of each climate zone will be constituted by isotherms (in full degrees Celsius) of the annual average ambient temperature which differ at least 4 oC.The temperature difference between the average annual ambient temperatures applied in adjacent climate zones will be at least 4 oC. Example: In a Member State the average annual ambient temperature in place A is 12 oC and in place B it is 6 oC. The difference is more than 5 oC. The Member State has now the option to introduce two climate zones separated by the isotherm of 9 oC, thus constituting one climate zone between the isotherms of 9 oC and 13 oC with an average annual ambient temperature of 11 oC and another climate zone between the isotherms of 5 oC and 9 oC with an average annual ambient temperature of 7 oC.
ANNEX IV Correction factors for avoided grid losses for the application of the harmonised efficiency reference values for separate production of electricity (referred to in Article 2(2))
Voltage: For electricity exported to the grid For electricity consumed on-site > 200 kV 1 0,985 100-200 kV 0,985 0,965 50-100 kV 0,965 0,945 0,4-50 kV 0,945 0,925 < 0,4 kV 0,925 0,860 Example: A 100 kWel cogeneration unit with a reciprocating engine driven with natural gas generates electricity of 380 V. Of this electricity 85 % is used for own consumption and 15 % is fed into the grid. The plant was constructed in 1999. The annual ambient temperature is 15 oC (so no climatic correction is necessary). According to Annex I of this Decision the harmonised efficiency reference value of 1999 for natural gas is 51,1 %. After the grid loss correction the resulting efficiency reference value for the separate production of electricity in this cogeneration unit would be (based on the weighted mean of the factors in this Annex): Ref Eη = 51,1 % * (0,860 * 85 % + 0,925 * 15 %) = 44,4 %
Versions
Cited by
- Commission Decision of 9 July 2009 establishing the ecological criteria for the award of the Community eco-label for tourist accommodation service (notified under document number C(2009) 5619) (Text with EEA relevance) (2009/578/EC) Decision · Grade B
District heating (1,5 points) The heating of the tourist accommodation shall be provided by efficient district heating, for the purposes of the eco-label defined as follows. Generation of heat is done either in high efficiency cogeneration units as defined by Directive 2004/8/EC and any other Commission instruments adopted in application of that Directive, or in heat only boilers with an efficiency that matches or surpasses the applicable reference value established by Commission Decision 2007/74/EC; And in addition: The pipes in the district heating distribution network shall meet the require
- Commission Regulation (EC) No 800/2008 of 6 August 2008 declaring certain categories of aid compatible with the common market in application of Articles 87 and 88 of the Treaty (General block exemption Regulation) (Text with EEA relevance) Regulation · Grade B
high efficiency cogeneration means cogeneration meeting the criteria of Annex III to Directive 2004/8/EC of the European Parliament and of the Council and satisfying the harmonised efficiency reference values established by Commission Decision 2007/74/EC;
- Commission Regulation (EC) No 800/2008 of 6 August 2008 declaring certain categories of aid compatible with the common market in application of Articles 87 and 88 of the Treaty (General block exemption Regulation) (Text with EEA relevance) Regulation · Grade B
A new cogeneration unit shall overall make primary energy savings compared to separate production as provided for by Directive 2004/8/EC and Decision 2007/74/EC. The improvement of an existing cogeneration unit or conversion of an existing power generation unit into a cogeneration unit shall result in primary energy savings compared to the original situation.
- Commission Implementing Decision of 19 December 2011 establishing harmonised efficiency reference values for separate production of electricity and heat in application of Directive 2004/8/EC of the European Parliament and of the Council and repealing Commission Decision 2007/74/EC (notified under document C(2011) 9523) (2011/877/EU) Decision · Grade B
Pursuant to Directive 2004/8/EC the Commission established in Decision 2007/74/EC harmonised efficiency reference values for separate production of electricity and heat, consisting of a matrix of values differentiated by relevant factors, including year of construction and types of fuel.
- Commission Implementing Decision of 19 December 2011 establishing harmonised efficiency reference values for separate production of electricity and heat in application of Directive 2004/8/EC of the European Parliament and of the Council and repealing Commission Decision 2007/74/EC (notified under document C(2011) 9523) (2011/877/EU) Decision · Grade B
The Commission has reviewed the harmonised efficiency reference values for separate production of electricity and heat, taking into account data from operational use under realistic conditions, provided by the Member States. Developments in the best available and economically justifiable technology which took place during the period 2006-2011 which was covered by the review, indicate that for the harmonised efficiency reference values for separate production of electricity, the distinction drawn in Decision 2007/74/EC relating to the year of construction of a cogeneration unit should not be ma
- Commission Implementing Decision of 19 December 2011 establishing harmonised efficiency reference values for separate production of electricity and heat in application of Directive 2004/8/EC of the European Parliament and of the Council and repealing Commission Decision 2007/74/EC (notified under document C(2011) 9523) (2011/877/EU) Decision · Grade B
Data from operational use under realistic conditions do not demonstrate a statistically significant improvement of the actual performance of state-of-the-art plants in the period under review. Therefore the reference values established for the period 2006-2011 in Decision 2007/74/EC should be maintained for the period 2012-2015.
- Commission Implementing Decision of 19 December 2011 establishing harmonised efficiency reference values for separate production of electricity and heat in application of Directive 2004/8/EC of the European Parliament and of the Council and repealing Commission Decision 2007/74/EC (notified under document C(2011) 9523) (2011/877/EU) Decision · Grade B
Revised harmonised efficiency reference values for separate production of electricity and heat should be established. Decision 2007/74/EC should, therefore, be repealed.
- Commission Implementing Decision of 19 December 2011 establishing harmonised efficiency reference values for separate production of electricity and heat in application of Directive 2004/8/EC of the European Parliament and of the Council and repealing Commission Decision 2007/74/EC (notified under document C(2011) 9523) (2011/877/EU) Decision · Grade B
Decision 2007/74/EC shall be repealed.
- Commission Regulation (EC) No 1147/2008 of 31 October 2008 amending Regulation (EC) No 794/2004 of 21 April 2004 implementing Council Regulation (EC) No 659/1999 laying down detailed rules for the application of Article 93 of the EC Treaty, as regards Part III.10 of its Annex 1 Regulation · Grade B
the new cogeneration unit will overall make primary energy savings compared to separate production as defined by Directive 2004/8/EC and Commission Decision 2007/74/EC.
- Commission Regulation (EC) No 1147/2008 of 31 October 2008 amending Regulation (EC) No 794/2004 of 21 April 2004 implementing Council Regulation (EC) No 659/1999 laying down detailed rules for the application of Article 93 of the EC Treaty, as regards Part III.10 of its Annex 1 Regulation · Grade B
Operating aid Please confirm that the existing cogeneration unit satisfies both the definition of high-efficiency cogeneration set out in point 70(11) of the Environmental aid guidelines and the requirement that there are overall primary savings compared to separate production as defined by Directive 2004/8/EC and Decision 2007/74/EC: Please confirm further that the operating aid for high efficiency cogeneration is granted exclusively to: Please provide details and evidence that the relevant condition(s) is/are complied with: … …
- Commission Decision of 9 July 2009 establishing the ecological criteria for the award of the Community eco-label for campsite service (notified under document number C(2009) 5618) (Text with EEA relevance) (2009/564/EC) Decision · Grade B
District heating (1,5 points) The heating of the campsite shall be provided by efficient district heating, for the purposes of the eco-label defined as follows. Generation of heat is done either in high efficiency cogeneration units as defined by Directive 2004/8/EC and any other Commission instruments adopted in application of that Directive, or in heat only boilers with an efficiency that matches or surpasses the applicable reference value established by Commission Decision 2007/74/EC. And in addition: Assessment and verification: The applicant shall provide a declaration of compliance with
- Opinion of Advocate General Bot delivered on 8 May 2013 Case C‑195/12 Industrie du bois de Vielsalm & Cie (IBV) SA v Région wallonne (Request for a preliminary ruling from the Cour constitutionnelle (Belgium)) Opinion · Grade B
Point 70(11) of the Guidelines defines high-efficiency cogeneration in the following terms: cogeneration meeting the criteria of Annex III to Directive 2004/8... and satisfying the harmonised efficiency reference values established by Commission Decision 2007/74/EC of 21 December 2006 establishing harmonised efficiency reference values for separate production of electricity and heat in application of Directive 2004/8 [].
- Community guidelines on State aid for environmental protection (Text with EEA relevance) (2008/C 82/01) Notice · Grade B
high-efficiency cogeneration means cogeneration meeting the criteria of Annex III to Directive 2004/8/EC and satisfying the harmonised efficiency reference values established by Commission Decision 2007/74/EC of 21 December 2006 establishing harmonised efficiency reference values for separate production of electricity and heat in application of Directive 2004/8/EC of the European Parliament and of the Council;
- Community guidelines on State aid for environmental protection (Text with EEA relevance) (2008/C 82/01) Notice · Grade B
energy-efficient district heating means district heating which, with regard to generation, either complies with the criteria for high-efficiency cogeneration or, in the case of heat-only boilers, meets the reference values for separate heat production laid down in Decision 2007/74/EC;
- Community guidelines on State aid for environmental protection (Text with EEA relevance) (2008/C 82/01) Notice · Grade B
a new cogeneration unit will overall make primary energy savings compared to separate production as defined by Directive 2004/8/EC and Decision 2007/74/EC;
- Community guidelines on State aid for environmental protection (Text with EEA relevance) (2008/C 82/01) Notice · Grade B
For operating aid, an existing cogeneration must satisfy both the definition of high-efficiency cogeneration set out in point 70(11) and the requirement that there are overall primary energy savings compared to separate production as defined by Directive 2004/8/EC and Decision 2007/74/EC.